The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
A constrained least‐squares approach to the automated quantitation of in vivo 1H magnetic resonance spectroscopy data
Open accessAbstract
Totally Automatic Robust Quantitation in NMR (TARQUIN), a new method for the fully automatic analysis of short echo time in vivo 1 H Magnetic resonance spectroscopy is presented. Analysis is performed in the time domain using non‐negative least squares, and a new method for applying soft constraints to signal amplitudes is used to improve fitting stability. Initial point truncation and Hankel singular value decomposition water removal are used to reduce baseline interference. Three methods were used to test performance. First, metabolite concentrations from six healthy volunteers at 3 T were compared with LCModel™. Second, a Monte‐Carlo simulation was performed and results were compared with LCModel™ to test the accuracy of the new method. Finally, the new algorithm was applied to 1956 spectra, acquired clinically at 1.5 T, to test robustness to noisy, abnormal, artifactual, and poorly shimmed spectra. Discrepancies of less than approximately 20% were found between the main metabolite concentrations determined by TARQUIN and LCModel™ from healthy volunteer data. The Monte‐Carlo simulation revealed that errors in metabolite concentration estimates were comparable with LCModel™. TARQUIN analyses were also found to be robust to clinical data of variable quality. In conclusion, TARQUIN has been shown to be an accurate and robust algorithm for the analysis of magnetic resonance spectroscopy data making it suitable for use in a clinical setting. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Spin Dynamics: Basics of Nuclear Magnetic Resonance
Levitt, M. H. (2001) · Cited by 1,883
Proton NMR chemical shifts and coupling constants for brain metabolites
Govindaraju, V., Young, K., & Maudsley, A. A. (2000) · NMR in Biomedicine · doi:10.1002/1099-1492(200005)13:3<129::aid-nbm619>3.0.co;2-v · Cited by 1,689
Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge
Vanhamme, L., van den Boogaart, A., & Van Huffel, S. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1244 · Cited by 1,627
Java-based graphical user interface for the MRUI quantitation package
Naressi, A., Couturier, C., Devos, J. M., Janssen, M., Mangeat, C., Beer, R. D., & Graveron-Demilly, D. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668096 · Cited by 1,003
Computer Simulations in Magnetic Resonance. An Object-Oriented Programming Approach
Smith, S. A., Levante, T. O., Meier, B. H., & Ernst, R. R. (1994) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1994.1008 · Cited by 710
Preul, M. C., Caramanos, Z., Collins, D. L., Villemure, J.-G., Leblanc, R., Olivier, A., Pokrupa, R., & Arnold, D. L. (1996) · Nature Medicine · doi:10.1038/nm0396-323 · Cited by 523
Absolute Quantitation of Water and Metabolites in the Human Brain. I. Compartments and Water
Ernst, T., Kreis, R., & Ross, B. D. (1993) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1993.1055 · Cited by 504
Barkhuijsen, H., de Beer, R., Bovée, W. M. M. J., et al. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90187-8 · Cited by 480
Johnston, M. V. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200009)48:3<403::aid-ana24>3.0.co;2-c · Cited by 474
Analysis of macromolecule resonances in 1H NMR spectra of human brain
Behar, K. L., Rothman, D. L., Spencer, D. D., & Petroff, O. A. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320304 · Cited by 467
Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts
Kreis, R. (2004) · NMR in Biomedicine · doi:10.1002/nbm.891 · Cited by 430
In Vivo NMR Spectroscopy: Principles and Techniques
de Graaf, R. A. (2007) · Wiley eBooks · doi:10.1002/9780470512968 · Cited by 409
van der Veen, J. W. C., de Beer, R., Luyten, P. R., & van Ormondt, D. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060111 · Cited by 363
Mekle, R., Mlynárik, V., Gambarota, G., Hergt, M., Krueger, G., & Gruetter, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21961 · Cited by 324
Time‐domain semi‐parametric estimation based on a metabolite basis set
Ratiney, H., Sdika, M., Coenradie, Y., Cavassila, S., Ormondt, D. V., & Graveron‐Demilly, D. (2005) · NMR in Biomedicine · doi:10.1002/nbm.895 · Cited by 295
1H NMR visible lipids in the life and death of cells
Hakumäki, J. M., & Kauppinen, R. A. (2000) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(00)01614-5 · Cited by 228
Self-citationParameterized evaluation of macromolecules and lipids in proton MR spectroscopy of brain diseases
Seeger, U., Klose, U., Mader, I., Grodd, W., & Nägele, T. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10332 · Cited by 194
ProFit: two‐dimensional prior‐knowledge fitting of J‐resolved spectra
Schulte, R. F., & Boesiger, P. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1026 · Cited by 175
Gemperline, P. J., & Cash, E. (2003) · Analytical Chemistry · doi:10.1021/ac034301d · Cited by 154
Quality: quantification improvement by converting lineshapes to the lorentzian type
de Graaf, A. A., van Dijk, J. E., & BoéE, W. M. M. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130302 · Cited by 124
Quantitation of simulated short echo time 1H human brain spectra by LCModel and AMARES
Kanowski, M., Kaufmann, J., Braun, J., Bernarding, J., & Tempelmann, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20063 · Cited by 122
Astrakas, L. G., Zurakowski, D., Tzika, A. A., Zarifi, M. K., Anthony, D. C., Girolami, U. D., Tarbell, N. J., & Black, P. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0603 · Cited by 119
Baker, E. H., Basso, G., Barker, P. B., Smith, M. A., Bonekamp, D., & Horská, A. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21285 · Cited by 90
Fast Removal of Residual Water in Proton Spectra
Vanhamme, L., Fierro, R. D., Huffel, S. V., et al. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1425 · Cited by 74
Gottschalk, M. E., Lamalle, L., & Segebarth, C. M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1219 · Cited by 50
Automated quality control protocol for MR spectra of brain tumors
Wright, A. J., Arús, C., Wijnen, J. P., et al. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21533 · Cited by 41
Slotboom, J., Nirkko, A. C., Brekenfeld, C., & ORMONDT, D. V. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/10/104030 · Cited by 30
Cited by
Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA
Mullins, P. G., McGonigle, D. J., O'Gorman, R. L., Puts, N. A. J., Vidyasagar, R., Evans, C. J., & Edden, R. A. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.004 · Cited by 553
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Self-citationSimpson, R., Devenyi, G. A., Jezzard, P., Hennessy, T. J., & Near, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26091 · Cited by 368
Lin, A., Andronesi, O., Bogner, W., Choi, I., Coello, E., Cudalbu, C., Juchem, C., Kemp, G. J., Kreis, R., Krššák, M., et al. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4484 · Cited by 334
Reduced GABAergic Action in the Autistic Brain
Robertson, C. E., Ratai, E.-M., & Kanwisher, N. (2016) · Current Biology · doi:10.1016/j.cub.2015.11.019 · Cited by 327
Metadata
- Authors
- Wilson, M., Reynolds, G., Kauppinen, R. A., Arvanitis, T. N., & Peet, A. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-09-27
- Volume
- 65
- Issue
- 1
- Pages
- 1-12
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2149746172
- Cited by
- 332
- References
- 31
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.