Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 282

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

DREAM—a novel approach for robust, ultrafast, multislice B1 mapping

Nehrke, Kay, Börnert, Peter·2012·Magnetic Resonance in Medicine

Abstract

A novel multislice B1‐mapping method dubbed dual refocusing echo acquisition mode is proposed, able to cover the whole transmit coil volume in only one second, which is more than an order of magnitude faster than established approaches. The dual refocusing echo acquisition mode technique employs a stimulated echo acquisition mode (STEAM) preparation sequence followed by a tailored single‐shot gradient echo sequence, measuring simultaneously the stimulated echo and the free induction decay as gradient‐recalled echoes, and determining the actual flip angle of the STEAM preparation radiofrequency pulses from the ratio of the two measured signals. Due to an elaborated timing scheme, the method is insensitive against susceptibility/chemical shift effects and can deliver a B0 phase map and a transceive phase map for free. The approach has only a weak T1 and T2 dependence and moreover, causes only a low specific absorption rate (SAR) burden. The accuracy of the method with respect to systematic and statistical errors is investigated both, theoretically and in experiments on phantoms. In addition, the performance of the approach is demonstrated in vivo in B1‐mapping and radiofrequency shimming experiments on the abdomen, the legs, and the head on an eight‐channel parallel transmit 3 T MRI system. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24158

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 282

Metadata

Authors
Nehrke, K., & Börnert, P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2012-01-17
Volume
68
Issue
5
Pages
1517-1526
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2107855009
Cited by
282
References
24
FWCI
13.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.