Purpose: To introduce a new toolkit for simulation and processing of magnetic resonance spectroscopy (MRS) data, and to demonstrate some of its novel features. Methods: The FID appliance (FID‐A) is an open‐source, MATLAB‐based software toolkit for simulation and processing of MRS data. The software is designed specifically for processing data with multiple dimensions (eg, multiple radiofrequency channels, averages, spectral editing dimensions). It is equipped with functions for importing data in the formats of most major MRI vendors (eg, Siemens, Philips, GE, Agilent) and for exporting data into the formats of several common processing software packages (eg, LCModel, jMRUI, Tarquin). This paper introduces the FID‐A software toolkit and uses examples to demonstrate its novel features, namely 1) the use of a spectral registration algorithm to carry out useful processing routines automatically, 2) automatic detection and removal of motion‐corrupted scans, and 3) the ability to perform several major aspects of the MRS computational workflow from a single piece of software. This latter feature is illustrated through both high‐level processing of in vivo GABA‐edited MEGA‐PRESS MRS data, as well as detailed quantum mechanical simulations to generate an accurate LCModel basis set for analysis of the same data. Results: All of the described processing steps resulted in a marked improvement in spectral quality compared with unprocessed data. Fitting of MEGA‐PRESS data using a customized basis set resulted in improved fitting accuracy compared with a generic MEGA‐PRESS basis set. Conclusions: The FID‐A software toolkit enables high‐level processing of MRS data and accurate simulation of in vivo MRS experiments. Magn Reson Med 77:23–33, 2017. © 2015 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Proton NMR chemical shifts and coupling constants for brain metabolites
Govindaraju, V., Young, K., & Maudsley, A. A. (2000) · NMR in Biomedicine · doi:10.1002/1099-1492(200005)13:3<129::aid-nbm619>3.0.co;2-v · Cited by 1,689
Spatial Localization in NMR Spectroscopy in Vivo
BOTTOMLEY, P. A. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb32915.x · Cited by 1,378
Partial least squares analysis of neuroimaging data: applications and advances
McIntosh, A. R., & Lobaugh, N. J. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.020 · Cited by 1,099
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015
Java-based graphical user interface for the MRUI quantitation package
Naressi, A., Couturier, C., Devos, J. M., Janssen, M., Mangeat, C., Beer, R. D., & Graveron-Demilly, D. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668096 · Cited by 1,003
Image-selected in Vivo spectroscopy (ISIS). A new technique for spatially selective nmr spectroscopy
Ordidge, R. J., Connelly, A., & Lohman, J. A. B. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90031-4 · Cited by 811
Computer Simulations in Magnetic Resonance. An Object-Oriented Programming Approach
Smith, S. A., Levante, T. O., Meier, B. H., & Ernst, R. R. (1994) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1994.1008 · Cited by 710
Edden, R. A. E., Puts, N. A. J., Harris, A. D., Barker, P. B., & Evans, C. J. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24478 · Cited by 625
Field mapping without reference scan using asymmetric echo-planar techniques
Gruetter, R., & Tk�?, I. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<319::aid-mrm22>3.0.co;2-1 · Cited by 569
Muthukumaraswamy, S. D., Edden, R. A. E., Jones, D. K., Swettenham, J. B., & Singh, K. D. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900728106 · Cited by 567
Quantitation of magnetic resonance spectroscopy signals: the jMRUI software package
Stefan, D., Cesare, F. D., Andrasescu, A., Popa, E., Lazariev, A., Vescovo, E., Strbak, O., Williams, S., Starcuk, Z., Cabanas, M., et al. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/10/104035 · Cited by 514
Rapid Modulation of GABA Concentration in Human Sensorimotor Cortex During Motor Learning
Floyer-Lea, A., Wylezinska, M., Kincses, T., & Matthews, P. M. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00346.2005 · Cited by 350
Wilson, M., Reynolds, G., Kauppinen, R. A., Arvanitis, T. N., & Peet, A. C. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22579 · Cited by 332
Mekle, R., Mlynárik, V., Gambarota, G., Hergt, M., Krueger, G., & Gruetter, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21961 · Cited by 324
Magnetic resonance spectroscopy in temporal lobe epilepsy
Connelly, A., Jackson, G. D., Duncan, J. S., King, M. D., & Gadian, D. G. (1994) · Neurology · doi:10.1212/wnl.44.8.1411 · Cited by 317
Near, J., Edden, R., Evans, C. J., Paquin, R., Harris, A., & Jezzard, P. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25094 · Cited by 285
Self-citationvan Beek, J. D. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.03.017 · Cited by 231
Kurhanewicz, J., Vigneron, D. B., Nelson, S. J., Hricak, H., MacDonald, J. M., Konety, B., & Narayan, P. (1995) · Urology · doi:10.1016/s0090-4295(99)80016-8 · Cited by 215
Bednařík, P., Tkáč, I., Giove, F., DiNuzzo, M., Deelchand, D. K., Emir, U. E., Eberly, L. E., & Mangia, S. (2015) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.233 · Cited by 191
A mechanism for value-guided choice based on the excitation-inhibition balance in prefrontal cortex
Jocham, G., Hunt, L. T., Near, J., & Behrens, T. E. J. (2012) · Nature Neuroscience · doi:10.1038/nn.3140 · Cited by 183
Self-citationBaseline GABA concentration and fMRI response
Donahue, M. J., Near, J., Blicher, J. U., & Jezzard, P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.017 · Cited by 176
Self-citationProFit: two‐dimensional prior‐knowledge fitting of J‐resolved spectra
Schulte, R. F., & Boesiger, P. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1026 · Cited by 175
Individual Differences in Subconscious Motor Control Predicted by GABA Concentration in SMA
Boy, F., Evans, C. J., Edden, R. A. E., Singh, K. D., Husain, M., & Sumner, P. (2010) · Current Biology · doi:10.1016/j.cub.2010.09.003 · Cited by 172
Boy, F., Evans, J., Edden, R. A. E., Lawrence, A. D., Singh, K. D., Husain, M., & Sumner, P. (2011) · Biological Psychiatry · doi:10.1016/j.biopsych.2011.05.030 · Cited by 141
Matson, G. B. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)90086-7 · Cited by 131
Schaller, B., Xin, L., O’Brien, K., Magill, A. W., & Rolf Gruetter, A. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.016 · Cited by 127
Waddell, K. W., Avison, M. J., Joers, J. M., & Gore, J. C. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.11.026 · Cited by 122
Bottomley, P. A., Edelstein, W. A., Foster, T. H., & Adams, W. A. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.7.2148 · Cited by 115
Resting GABA and glutamate concentrations do not predict visual gamma frequency or amplitude
Cousijn, H., Haegens, S., Wallis, G., Near, J., Stokes, M. G., Harrison, P. J., & Nobre, A. C. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1321072111 · Cited by 110
Self-citationImpact of frequency drift on gamma-aminobutyric acid-edited MR spectroscopy
Harris, A. D., Glaubitz, B., Near, J., Evans, J., Puts, N. A. J., Schmidt‐Wilcke, T., Tegenthoff, M., Barker, P. B., & Edden, R. A. E. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25009 · Cited by 108
Self-citationGAVA: Spectral simulation for in vivo MRS applications
Soher, B. J., Young, K., Bernstein, A., Aygula, Z. K., & Maudsley, A. A. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.01.005 · Cited by 103
Hall, E. L., Stephenson, M. C., Price, D., & Morris, P. G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.077 · Cited by 66
Cited by
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Doss, M. K., Považan, M., Rosenberg, M. D., Sepeda, N. D., Davis, A. K., Finan, P. H., Smith, G. S., Pekar, J. J., Barker, P. B., Griffiths, R. R., et al. (2021) · Translational Psychiatry · doi:10.1038/s41398-021-01706-y · Cited by 356
Lin, A., Andronesi, O., Bogner, W., Choi, I., Coello, E., Cudalbu, C., Juchem, C., Kemp, G. J., Kreis, R., Krššák, M., et al. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4484 · Cited by 334
Self-citationRegional GABA Concentrations Modulate Inter-network Resting-state Functional Connectivity
Chen, X., Fan, X., Hu, Y., Zuo, C., Whitfield-Gabrieli, S., Holt, D., Gong, Q., Yang, Y., Pizzagalli, D. A., Du, F., et al. (2019) · Cerebral Cortex · doi:10.1093/cercor/bhy059 · Cited by 62
Roberts, T. P. L., Bloy, L., Ku, M., Blaskey, L., Jackel, C. R., Edgar, J. C., & Berman, J. I. (2020) · Autism Research · doi:10.1002/aur.2369 · Cited by 34
Metadata
- Authors
- Simpson, R., Devenyi, G. A., Jezzard, P., Hennessy, T. J., & Near, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2015-12-30
- Volume
- 77
- Issue
- 1
- Pages
- 23-33
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2279193171
- Cited by
- 368
- References
- 33
- FWCI
- 9.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.