The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Abstract
Magnetic resonance elastography (MRE) is a non‐invasive imaging technique used to visualise and quantify mechanical properties of tissue, providing information beyond what can be currently achieved with standard MR sequences and could, for instance, provide new insight into pathological processes in the brain. This study uses the MRE technique at 3 T to extract the complex shear modulus for in vivo brain tissue utilizing a full three‐dimensional approach to reconstruction, removing contributions of the dilatational wave by application of the curl operator. A calibrated phantom is used to benchmark the MRE measurements, and in vivo results are presented for healthy volunteers. The results provide data for in vivo brain storage modulus (G′), finding grey matter (3.1 kPa) to be significantly stiffer than white matter (2.7 kPa). The first in vivo loss modulus (G″) measurements show no significant difference between grey matter (2.5 kPa) and white matter (2.5 kPa). Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Kinsler, L. E., Frey, A. R., & Adams, C. E. (1963) · American Journal of Physics · doi:10.1119/1.1969118 · Cited by 1,403
Viscoelastic shear properties of in vivo breast lesions measured by MR elastography
Sinkus, R., Tanter, M., Xydeas, T., Catheline, S., Bercoff, J., & Fink, M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.11.060 · Cited by 503
Self-citation“Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues
Lerner, R. M., Huang, S. R., & Parker, K. J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90002-t · Cited by 493
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
Self-citationUltrasonic imaging of internal vibration of soft tissue under forced vibration
Yamakoshi, Y., Sato, J., & Sato, T. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.46969 · Cited by 474
Brain tissue deforms similarly to filled elastomers and follows consolidation theory
Franceschini, G., Bigoni, D., Regitnig, P., & Holzapfel, G. A. (2006) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2006.05.004 · Cited by 385
MR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Self-citationPlewes, D. B., Bishop, J., Samani, A., & Sciarretta, J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/314 · Cited by 318
Magnetic resonance elastography of skeletal muscle
Dresner, M. A., Rose, G. H., Rossman, P. J., Muthupillai, R., Manduca, A., & Ehman, R. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200102)13:2<269::aid-jmri1039>3.0.co;2-1 · Cited by 307
A solution to diffraction biases in sonoelasticity: The acoustic impulse technique
Catheline, S., Wu, F., & Fink, M. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426907 · Cited by 282
Effects of Proteins, Blood Cells and Glucose on the Viscosity of Cerebrospinal Fluid
Bloomfield, I. G., Johnston, I. H., & Bilston, L. E. (1998) · Pediatric Neurosurgery · doi:10.1159/000028659 · Cited by 232
Self-citationInitial in vivo experience with steady‐state subzone‐based MR elastography of the human breast
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10232 · Cited by 224
Nonlinear viscoelastic effects in oscillatory shear deformation of brain tissue
Darvish, K. K., & Crandall, J. R. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00101-1 · Cited by 198
Bilston, L. E., Liu, Z., & Phan‐Thien, N. (2001) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2001038004004 · Cited by 188
Self-citationShear linear behavior of brain tissue over a large frequency range
Nicolle, S., Lounis, M., Willinger, R., & Palierne, J. ‐. (2005) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2005042003003 · Cited by 176
Mechanical transient‐based magnetic resonance elastography
McCracken, P. J., Manduca, A., Felmlee, J., & Ehman, R. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20388 · Cited by 175
Viscoelastic characterization of in vitro canine tissue
Kiss, M. Z., Varghese, T., & Hall, T. J. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/002 · Cited by 172
Magnetic resonance elastography of brain tumors: preliminary results
Xu, L., Lin, Y., Han, J. C., Xi, Z. N., Shen, H.-J., & Gao, P. (2007) · Acta Radiologica · doi:10.1080/02841850701199967 · Cited by 133
Sonoelasticity of organs: shear waves ring a bell
Parker, K. J., & Lerner, R. M. (1992) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1992.11.8.387 · Cited by 128
MR Elastography of the Prostate: Initial In-vivo Application
Kemper, J., Sinkus, R., Lorenzen, J., Nolte-Ernsting, C. C. A., Stork, A., & Adam, G. (2004) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2004-813279 · Cited by 119
Self-citationHamhaber, U., Sack, I., Papazoglou, S., Rump, J., Klatt, D., & Braun, J. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.08.007 · Cited by 98
Sack, I., Bernarding, J., & Braun, J. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00474-5 · Cited by 69
Magnetic resonance elastography of the human brain: a preliminary study
Xu, L., Lin, Y., Xi, Z. N., Shen, H.-J., & Gao, P. (2007) · Acta Radiologica · doi:10.1080/02841850601026401 · Cited by 50
“Palpation of the Brain” Using Magnetic Resonance Elastography
G-use, S. A., Dresner, M. A., Rossman, P. J., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (1999) · Cited by 35
Cited by
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Mechanical properties of gray and white matter brain tissue by indentation
Budday, S., Nay, R., de Rooij, R., Steinmann, P., Wyrobek, T., Ovaert, T. C., & Kuhl, E. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.02.024 · Cited by 692
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Metadata
- Authors
- Green, M. A., Bilston, L. E., & Sinkus, R.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2008-05-06
- Volume
- 21
- Issue
- 7
- Pages
- 755-764
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2152072871
- Cited by
- 418
- References
- 26
- FWCI
- 15.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.