The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Eccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Open accessAbstract
Purpose: Sweat is a relatively unexplored biofluid for diagnosis and monitoring of disease states. In this study, the proteomic profiling of immune‐related biomarkers from healthy individuals are presented. Experimental Design: Eccrine sweat samples are collected from 50 healthy individuals. LC‐MS/MS is performed on two pools of sweat samples from five male and female participants. Individual sweat samples are analyzed by antibody isotyping microarrays ( n = 49), human cytokine arrays ( n = 30), and quantitative ELISAs for interleukin‐1α ( n = 16), epidermal growth factor ( n = 6), and angiogenin ( n = 7). Results: In sweat, 220 unique proteins are identified by shotgun analysis. Detectable antibody isotypes include IgA (100% positive; median 1230 ± 28 700 pg mL −1 ), IgD (18%; 22.0 ± 119 pg mL −1 ), IgG1 (96%; 1640 ± 6750 pg mL −1 ), IgG2 (37%; 292 ± 6810 pg mL −1 ), IgG3 (71%; 74.0 ± 119 pg mL −1 ), IgG4 (69%; 43.0 ± 42.0 pg mL −1 ), and IgM (41%; 69.0 ± 1630 pg mL −1 ). Of 42 cytokines, three are readily detected in all sweat samples ( p < 0.01). The median concentration for interleukin‐1α is 352 ± 521 pg mL −1 , epidermal growth factor is 86.5 ± 147 pg mL −1 , and angiogenin is 38.3 ± 96.3 pg mL −1 . Multiple other cytokines are detected at lower levels. Conclusions and Clinical Relevance: Sweat can be used for profiling antibodies and innate immune biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“its concentration is ~ 100 × lower than that of blood glucose”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Katchman et al. 2018
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Some recent papers have suggested a potential route of glucose transport that is paracellular in nature”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Katchman et al. 2018
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale gene function analysis with the PANTHER classification system
Mi, H., Muruganujan, A., Casagrande, J. T., & Thomas, P. D. (2013) · Nature Protocols · doi:10.1038/nprot.2013.092 · Cited by 2,466
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Dursun, E., Gezen-Ak, D., Hanağası, H., Bilgiç, B., Lohmann, E., Ertan, S., Atasoy, İ. L., Alaylıoğlu, M., Araz, Ö. S., Önal, B., et al. (2015) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2015.04.014 · Cited by 237
Sweat: A sample with limited present applications and promising future in metabolomics
Mena-Bravo, A., & Luque de Castro, M. D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.10.048 · Cited by 235
Recent Developments in Sweat Analysis and Its Applications
Jadoon, S., Karim, S., Akram, M. R., Kalsoom Khan, A., Zia, M. A., Siddiqi, A. R., & Murtaza, G. (2015) · International Journal of Analytical Chemistry · doi:10.1155/2015/164974 · Cited by 216
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Circulating Cytokines as Biomarkers of Alcohol Abuse and Alcoholism
Achur, R. N., Freeman, W. M., & Vrana, K. E. (2010) · Journal of Neuroimmune Pharmacology · doi:10.1007/s11481-009-9185-z · Cited by 200
Raiszadeh, M. M., Ross, M. M., Russo, P. S., Schaepper, M. A., Zhou, W., Deng, J., Ng, D., Dickson, A., Dickson, C., Strom, M., et al. (2012) · Journal of Proteome Research · doi:10.1021/pr2007957 · Cited by 142
Research works printed but not linked: 1
- Brodersen M., 1976, Acta Hepatogastroenterol., 23, 194
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Self-citationSkin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
“Early reports showed that sweat contains cortisol levels comparable with those reported in saliva;(42) we postulate that circulating cortisol molecules are transported to and stored in eccrine and apocrine glands, secreted into the sweat, and ultimately excreted through a sweat pore to the epidermal surface.(43) It is…”
BackgroundBroza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
The challenges and promise of sweat sensing
Davis, N., Heikenfeld, J., Milla, C., & Javey, A. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-02059-1 · Cited by 211
Recent progress, challenges, and opportunities for wearable biochemical sensors for sweat analysis
Ghaffari, R., Rogers, J. A., & Ray, T. R. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129447 · Cited by 212
“As detailed elsewhere [1,3,4,11,12,18,33,49,50], the rich matrix of electrolytes, metabolites, hormones, and small molecules found in eccrine sweat offer valuable insights into human metabolic and physiological status with many constituents present only in extremely low concentrations.”
BackgroundSkin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics
Ghaffari, R., Yang, D. S., Kim, J., Mansour, A., Wright, J. A., Model, J. B., Wright, D. E., Rogers, J. A., & Ray, T. R. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01133 · Cited by 178
“Intense physical activity, exposure to heat stress, and localized chemical inducement are the core methods for generating sufficient microliter volumes of sweat for biochemical analysis with suitability defined by target application 16,100-104 .”
Field effect transistor based wearable biosensors for healthcare monitoring
Nguyen, T. T.-H., Nguyen, C., Huynh, M., Vu, H. H., Nguyen, T.-K., & Nguyen, N.-T. (2023) · Journal of Nanobiotechnology · doi:10.1186/s12951-023-02153-1 · Cited by 134
“Similarly, ELISA [5, 6], which is extensively used in laboratory environments for clinical diagnosis of biochemical species, suffers from lengthy analysis time, limited usability outside traditional diagnostic laboratories, reliance on bulky analytical instruments [7], and the requirement for…”
BackgroundLegner, C. M., Kalwa, U., Patel, V., Chesmore, A., & Pandey, S. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.07.020 · Cited by 151
“range of concentrations reported for different sweat analytes [16,38,41,42,50].”
BackgroundStress Monitoring and Recent Advancements in Wearable Biosensors
Samson, C., & Koh, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01037 · Cited by 129
Sweat as a Source of Next-Generation Digital Biomarkers
Brasier, N., & Eckstein, J. (2019) · Digital Biomarkers · doi:10.1159/000504387 · Cited by 122
Hybrid Integration of Wearable Devices for Physiological Monitoring
Zhang, Y., Zheng, X. T., Zhang, X., Pan, J., & Thean, A. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00471 · Cited by 135
Jagannath, B., Lin, K., Pali, M., Sankhala, D., Muthukumar, S., & Prasad, S. (2021) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10220 · Cited by 98
Finger sweat analysis enables short interval metabolic biomonitoring in humans
Brunmair, J., Gotsmy, M., Niederstaetter, L., Neuditschko, B., Bileck, A., Slany, A., Feuerstein, M. L., Langbauer, C., Janker, L., Zanghellini, J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26245-4 · Cited by 96
Clark, K. M., & Ray, T. R. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01512 · Cited by 92
Technological Advances of Wearable Device for Continuous Monitoring of In Vivo Glucose
Huang, X., Yao, C., Huang, S., Zheng, S., Liu, Z., Liu, J., Wang, J., Chen, H., & Xie, X. (2024) · ACS Sensors · doi:10.1021/acssensors.3c01947 · Cited by 88
Assalve, G., Lunetti, P., di Cagno, A., Luca, E. W. D., Aldegheri, S., Zara, V., & Ferramosca, A. (2024) · Biosensors · doi:10.3390/bios14120574 · Cited by 99
Liu, D., Liu, Z., Feng, S., Gao, Z., Chen, R., Cai, G., & Bian, S. (2023) · Biosensors · doi:10.3390/bios13020157 · Cited by 74
“In the sweat of the secretion, many substances related to the physiological state of the human body, including inorganic, metabolites, acids, hormones, and small proteins/peptides, passively or actively penetrate sweat from nearby blood or interstitial fluids [12,13].”
BackgroundSingh, A., Ahmed, A., Sharma, A., & Arya, S. K. (2022) · Biosensors · doi:10.3390/bios12100910 · Cited by 68
Non-invasive wearable electrochemical sensors for continuous glucose monitoring
Ameen, S. S. M., Omer, K. M., Mansour, F. R., Bedair, A., & Hamed, M. (2025) · Electrochemistry Communications · doi:10.1016/j.elecom.2025.107894 · Cited by 69
Epidermal Wearable Biosensors for Monitoring Biomarkers of Chronic Disease in Sweat
Yuan, X., Li, C., Yin, X., Yang, Y., Ji, B., Niu, Y., & Ren, L. M. (2023) · Biosensors · doi:10.3390/bios13030313 · Cited by 64
“detected immunoglobulins in sweat [49] and other researchers demonstrated the correlation between different cytokine concentrations in sweat and serum, indicating that sweat analysis has the potential to be a non-invasive inflammation monitoring tool [53].”
BackgroundAdvancing electrochemical biosensors for interleukin-6 detection
McCrae, L. E., Ting, W., & Howlader, M. M. R. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100288 · Cited by 61
Chu, S. S., Nguyen, H. A., Zhang, J., Tabassum, S., & Cao, H. (2022) · Sensors · doi:10.3390/s22145200 · Cited by 62
“In addition, sweat sample preparation takes minimal time and effort due to the absence of most of the impurities that are otherwise present in blood samples [65].”
BackgroundResultInkjet-printed Ti3C2Tx MXene electrodes for multimodal cutaneous biosensing
Saleh, A., Wustoni, S., Bihar, E., El‐Demellawi, J. K., Zhang, Y., Hama, A., Druet, V., Yudhanto, A., Gilles Lubineau, A., Alshareef, H. N., et al. (2020) · Journal of Physics Materials · doi:10.1088/2515-7639/abb361 · Cited by 64
Tu, W., Sun, M. J., Lu, T., Chen, Y., Zhou, Y., Zhang, C., Ni, Z., Li, X., & Hu, T. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117736 · Cited by 53
Hossain, N. I., Noushin, T., & Tabassum, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-81042-5 · Cited by 44
Cinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 38
Carr, A. R., Patel, Y., Neff, C. R., Charkhabi, S., Kallmyer, N. E., Angus, H. F., & Reuel, N. F. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0270-2 · Cited by 40
Serag, A., Shakkour, Z., Halboup, A. M., Kobeissy, F. H., & Farag, M. A. (2021) · Journal of Proteomics · doi:10.1016/j.jprot.2021.104310 · Cited by 34
Cloud Server and Internet of Things Assisted System for Stress Monitoring
Singh, R., Gehlot, A., Rashid, M. U., Saxena, R., Akram, S. V., Alshamrani, S. S., & AlGhamdi, A. S. (2021) · Electronics · doi:10.3390/electronics10243133 · Cited by 32
Specific sweat metabolite profile in ocular Behcet’s disease
Cui, X., Zhang, L., Su, G., Kijlstra, A., & Yang, P. (2021) · International Immunopharmacology · doi:10.1016/j.intimp.2021.107812 · Cited by 30
Brunmair, J., Bileck, A., Stimpfl, T., Raible, F., Favero, G. D., Meier, S. M., & Gerner, C. (2021) · The EPMA Journal · doi:10.1007/s13167-021-00241-6 · Cited by 27
“Antibodies and cytokines detected in sweat may serve as potential biomarkers for diseases [38] and, as already demonstrated, for disease states in cystic fibrosis [40] and active tuberculosis [41].”
BackgroundRao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 42
Rind, S., Zhang, N., Khan, W. U., & Zhang, Q. M. (2025) · Wearable electronics. · doi:10.1016/j.wees.2025.08.002 · Cited by 31
Alginate Bead Biosystem for the Determination of Lactate in Sweat Using Image Analysis
García-Rey, S., Ojeda, E., Gunatilake, U. B., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2021) · Biosensors · doi:10.3390/bios11100379 · Cited by 29
Aranyosi, A. J., Model, J. B., Zhang, M. Z., Lee, S. P., Leech, A., Li, W., Seib, M. S., Chen, S., Reny, N., Wallace, J. C., et al. (2020) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2020.05.107 · Cited by 29
“Of these, the sweat collection and extraction steps are most prone to introducing errors arising from sample contamination, evaporation, and spillage, which affects measurement accuracy, especially for the analysis of small proteins and cytokines in sweat (Dai et al., 2013; Katchman et al., 2018).”
BackgroundMethodApplication of Microfluidics in Biosensors
Wang, J., Ren, Y., & Zhang, B. (2020) · IntechOpen eBooks · doi:10.5772/intechopen.91929 · Cited by 24
“sweat, saliva, tears, urine, and can be used in the prediction and diagnosis of various diseases [75-77].”
BackgroundNon-invasive glucose monitoring devices: A review
Mohamad Yunos, M. F. A., & Nordin, A. N. (2020) · Bulletin of Electrical Engineering and Informatics · doi:10.11591/eei.v9i6.2628 · Cited by 20
“5) and is composed mainly of water, electrolytes, urea with smaller amounts of glucose, antigens, antibodies and cytokines [9].”
BackgroundSteijlen, A. S. M., Bastemeijer, J., Groen, P., Jansen, K. M. B., French, P. J., & Bossche, A. (2020) · Analytical Methods · doi:10.1039/d0ay02014a · Cited by 21
Burat, B., Reynaerts, A., Baiwir, D., Fléron, M., Eppe, G., Leal, T., & Mazzucchelli, G. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910871 · Cited by 20
“The sweat proteome was significantly enriched in: (i) proteins related to proteolytic activity, proteases and peptidases [11] as well as their respective inhibitors, and (ii) protein effectors and regulators of the innate and adaptive immune systems [10,13].”
BackgroundMethodZhyvolozhnyi, A., Samoylenko, A., Bart, G., Kaisanlahti, A., Hekkala, J., Makieieva, O., Pratiwi, F. W., Miinalainen, I., Kaakinen, M., Bergman, U., et al. (2023) · Nanotheranostics · doi:10.7150/ntno.87822 · Cited by 17
“However, at present it is only routinely used in diagnosis of cystic fibrosis in newborn babies [8] due to limited number of known analytes [2,9–11].”
Weaving Off‐The‐Shelf Yarns into Textile Micro Total Analysis Systems (μTAS)
Månsson, I. Ö., Piper, A., & Hamedi, M. M. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000150 · Cited by 18
On-demand lactate monitoring towards assessing physiological responses in sedentary populations
Bhide, A., Lin, K., Muthukumar, S., & Prasad, S. (2021) · The Analyst · doi:10.1039/d1an00455g · Cited by 19
Burat, B., Reynaerts, A., Baiwir, D., Fléron, M., Gohy, S. T., Eppe, G., Leal, T., & Mazzucchelli, G. (2022) · Cells · doi:10.3390/cells11152358 · Cited by 15
King, M. A., Brown, S. D., Barnes, K. A., Chavez, P. J. D. D., & Baker, L. B. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05187-3 · Cited by 16
Advancements and Obstacles in Sweat-Based Biosensors for Health Monitoring
Lihong, Z., & Li, Q. (2025) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2568615 · Cited by 14
Wearable Chemosensors in Physiological Monitoring
Tang, Z.-Y., Cui, T., Liu, H., Jian, J., Li, D., Yang, Y., & Ren, T. (2023) · Chemosensors · doi:10.3390/chemosensors11080459 · Cited by 12
Biomedical sensing applications of soft, wearable microfluidic systems
Ibrahim, M. E., Naman, A., Lee, M.-S., Park, S., Lee, D., Kwak, Y., & Kim, M. (2025) · Soft Science · doi:10.20517/ss.2025.45 · Cited by 9
Advances in Electrochemical Nanobiosensors for Noninvasive Stress Biomarker Detection
Messina, L., Amadoro, P., & Giardi, M. T. (2025) · Sensors · doi:10.3390/s25237255 · Cited by 9
“The authors postulate that circulating cortisol molecules are transported to and stored in eccrine and apocrine glands, secreted into the sweat, and ultimately excreted through a sweat pore to the epidermal surface [79].”
Sweat as a diagnostic biofluid: analytical advances and future directions
Bordin, D. M., McCauley, J. I., de Campos, E. G., Bishop, D., & Martinis, B. S. D. (2025) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2025.101473 · Cited by 10
“Further, to aid protein separation and identification for downstream mass spectrometric analysis, two techniques are commonly used: two-dimensional gel electrophoresis (2-DE) and liquid chromatography, especially reversed-phase liquid chromatography (RP-LC) [63,64].”
Gubin, D. G. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839167553-00536 · Cited by 7
Cortisol Biosensors: From Sensing Principles to Applications
Tanaka, Y., Salleh, N. A. B. M., Aung, K. M. M., Su, X., & Sutarlie, L. (2023) · World Scientific Annual Review of Functional Materials · doi:10.1142/s2810922823300015 · Cited by 5
Micro scale chromatography of human plasma proteins for nano LC-ESI-MS/MS
Chen, Z. Z., Dufresne, J., Bowden, P., Celej, D., Miao, M., & Marshall, J. G. (2024) · Analytical Biochemistry · doi:10.1016/j.ab.2024.115694 · Cited by 5
Ishimaru, H., Nakamoto, K., Yamane, M., Yamamoto, T., Kitakaze, K., Takenouchi, Y., Tsuboi, K., Okamoto, Y., & Aoyama, Y. (2024) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2024.02.025 · Cited by 4
Cornet, M., Nguyen‐Khoa, T., Kelly, M., Jung, V. A., Chedevergne, F., Bourgeois, M. L., Aoust, L., Roger, K., Guerrera, I. C., & Sermet‐Gaudelus, I. (2022) · Skin Health and Disease · doi:10.1002/ski2.161 · Cited by 3
Smartphone-enabled biomedical sensors for healthcare applications: progress and perspective
Paine, S., Ghosh, A., Choudhury, A., Akbar, S. A., Ray, A., & Mukherjee, K. (2025) · Measurement · doi:10.1016/j.measurement.2025.118466 · Cited by 4
Merritt, J. R., Ozga, M., Chavez, P. J. D. D., Boolani, A., & Baker, L. B. (2024) · Scientific Reports · doi:10.1038/s41598-024-63057-0 · Cited by 3
Future Developments in Invasive and Non-invasive Diabetes Monitoring
Harb, F., Azar, W. S., Ghadieh, H. E., Njeim, R., Tawk, Y., Costantine, J., Kanj, R. N., & Eid, A. A. (2022) · Springer series on bio- and neurosystems · doi:10.1007/978-3-030-99728-1_15 · Cited by 3
Noninvasive Biomarkers for Disease Diagnosis and Health Monitoring
Pandey, R., Ngaju, P., Janghorban, M., Abuelazm, H., Malaeb, K., & Aryal, K. P. (2024) · Springer eBooks · doi:10.1007/978-981-97-5473-1_2 · Cited by 10
Touchpad-based immunochromatographic strip for detecting the skin surface proteins
Tsukada, H., Wako, M., Ueda, S., & Nagamine, K. (2024) · Analytical Biochemistry · doi:10.1016/j.ab.2024.115575 · Cited by 2
Silverio, A. A., Ho, E. T. W., Ang, J., & Esguerra, K. (2024) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ad2305 · Cited by 2
“There is growing interest in sweat analysis for health monitoring as it provides non-invasive access to physiological information through the biomarkers present in sweat [1, 2].”
Microparticles in Human Perspiration as an Inflammatory Response Index
Imtiyaz, Z., Bhopale, V. M., Arya, A. K., Bhat, A. R., & Thom, S. R. (2024) · Diagnostics · doi:10.3390/diagnostics14121293 · Cited by 2
“Antibodies, cytokines, nucleic acids, antimicrobial/defense proteins, and protein metabolites are present in human perspiration [1–3].”
BackgroundClinical Diagnostics Ex-Vivo Based on Fluorescence
Demchenko, A. P. (2023) · Springer eBooks · doi:10.1007/978-3-031-19089-6_14 · Cited by 2
Microbiosensors: Advancing diagnosis and prognosis through MEMS
Agarwalla, S., Singh, S. K., & Duraiswamy, S. (2025) · Biomicrofluidics · doi:10.1063/5.0245253 · Cited by 2
Kumar, A., Karmakar, S., Giddaluru, S. G., Singh, P., Lin, K., Muthukumar, S., & Prasad, S. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100715 · Cited by 1
Continuous molecular monitoring to advance biosensing: Strategies and challenges
Lai, Q., Dong, Y., & Liu, G. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.179383 · Cited by 2
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 1
Wearable Health Monitoring System for Sweat Analysis
Pagar, V., Bhadane, P. K., & Shaligram, A. D. (2024) · Communications in computer and information science · doi:10.1007/978-3-031-54547-4_31 · Cited by 1
Exercise-induced Sweat Promotes Wound Healing in Diabetic Foot UlcersPreprint
Zhao, M., Tong, Y., Yao, H., Cao, J., Liang, T., Fei, Q., Liang, M., Yang, B., Sun, M., Wang, C., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.04.11.717882 · Cited by 1
“These components exert antimicrobial and anti-inflammatory activities and may be closely associated with cutaneous immune defense and tissue repair 24,25 .”
Status and Future Prospect of Sweat Lactate Monitoring System (Review)
Kudo, H. (2021) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.141.83
Legner, C. M. (2020) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-20210114-80
Preparation of the artificial “skin” uniform sweating simulation device
Zheng, H., Liu, M., Yang, X., Cao, Y. F., Nie, W., Wang, S., & Zhang, T. (2022) · Scientia Sinica Technologica · doi:10.1360/sst-2022-0114
Wet Interface Technologies for Wearable Sweat Sensors
Nagamine, K., & Tokito, S. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_10
Validation of a Novel Method for Measuring Sweat-Derived Immunoglobulin A
Goryoda, S., Yamasawa, M., Ogasawara, Y., Tsukada, H., Ueda, S., Wako, M., & Nagamine, K. (2026) · Cureus · doi:10.7759/cureus.100811
“Attempts to detect IgA from the skin surface are still limited [16,17], and there are only a few reports on the efficacy of this method.”
Cornet, M. (2022) · theses.fr (ABES) · doi:10.70675/2ba36ddbz63efz4003zac14za87318c44691 · Cited by 1
Megha, A., Gandhi, M., Nakai, A., & Varghese, A. (2026) · ChemistrySelect · doi:10.1002/slct.73729
Evaluation of pilocarpine effects on sweat proteome
Wislet, S., Goff, C. L., Massonnet, P., Hody, S., Croisier, J. L., D'Orio, V., Kaux, J., Mazzucchelli, G., & Cloots, R. (2026) · Journal of Proteomics · doi:10.1016/j.jprot.2026.105709
Applications of Wearable Sweat Biosensors in Sports Activities with Real-World Cases
Yan, J., Shi, J., Zhang, Z., Yang, M., Zhang, M., & Wang, M. (2026) · Bioengineering · doi:10.3390/bioengineering13080906
“Muscle tissue contains approximately 76% water, with electrolytes acting as primary regulators of osmotic water flux and hydration status [48].”
Painless Biosensing for Non‐Invasive Health Monitoring: Advances, Platforms and Future Directions
Alam, A., Gull, F., Hameed, M., Iqbal, I., Naz, S., Noor, H., Aslam, A., Younis, S., Vit, V., Mehmood, M. A., et al. (2026) · Electrochemical Science Advances · doi:10.1002/elsa.70041
Syutkin, V. S., Gryazev, I. P., Chetverikova, D. A., Kalinichev, A. V., & Peshkova, M. A. (2026) · Sensors · doi:10.3390/s26185774
Metadata
- Authors
- Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S.
- Affiliations
- Arizona State University (US)
- School of Electrical Engineering, Arizona State University Tempe AZ 85281 USA
- Corresponding author
- Katchman, Benjamin A.
- Anderson, Karen S.
- Venue
- PROTEOMICS – Clinical Applications
- Publisher
- Wiley
- Published
- 2018-06-28
- Volume
- 12
- Issue
- 6
- Pages
- e1800010-e1800010
- ISSN
- 1862-8346 (ISSN-L)
- 1862-8354
- PMC
- PMC6282813
- OpenAlex
- W2806578062
- Cited by
- 86
- References
- 26
- Citations by year
- 2026: 8 · 2025: 11 · 2024: 16 · 2023: 11 · 2022: 10 · 2021: 13 · 2020: 11 · 2019: 6
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- PROTEOMICS - CLINICAL APPLICATIONS (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health (IIS‐1521904)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Health Sciences › Medicine › Physiology (medical) › Salivary Gland Disorders and Functions
- Keywords
- eccrine sweat, immunological markers, antibody isotypes, IgA, IgG, IgM, IgD, cytokines, interleukin-1 alpha, epidermal growth factor, angiogenin, innate immunity, non-invasive diagnosis
- MeSH terms
- Adolescent, Adult, Aged, Chromatography, Liquid, Eccrine Glands, Female, Gene Expression Regulation, Humans, Male, Middle Aged, Proteins, Sweat, Biomarkers, Proteomics, Tandem Mass Spectrometry, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.