Diffusion Tensor Imaging
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Diffusion tensor MRI (DT-MRI) is the only non-invasive method for characterising the microstructural organization of tissue in vivo. Generating parametric maps that help to visualise different aspects of the tissue microstructure (mean diffusivity, tissue anisotropy and dominant fibre orientation) involves a number of steps from deciding on the optimal acquisition parameters on the scanner, collecting the data, pre-processing the data and fitting the model to generating final parametric maps for entry into statistical data analysis. Here, we describe an entire protocol that we have used on over 400 subjects with great success in our laboratory. In the 'Notes' section, we justify our choice of the various parameters/choices along the way so that the reader may adapt/modify the protocol to their own time/hardware constraints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 21×
“The amount of diffusion encoding for a particular combination of gradients is characterised by the b-matrix (1).”
BackgroundMethodInfluentialGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“Given that the image contrast is so different between the b = 0 image and those acquired at b = 1,000 s/mm2, cost functions for the registration such as cross-correlation tend to fail and much better results are obtained with entropy-based metrics, such as the mutual information index (and its normalised version) (36,…”
BackgroundBasser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Self-citationThe B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Self-citationReduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
Jones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
Self-citationPajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Pajevic, S., & Pierpaoli, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<526::aid-mrm15>3.0.co;2-j · Cited by 640
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Self-citationEcho-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Data Reduction and Error Analysis for the Physical Sciences, 2nd ed.
Bevington, P. R., Robinson, D. K., & Bunce, G. (1993) · American Journal of Physics · doi:10.1119/1.17439 · Cited by 559
Comprehensive approach for correction of motion and distortion in diffusion‐weighted MRI
Rohde, G. K., Barnett, A. S., Basser, P. J., Marenco, S., & Pierpaoli, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10677 · Cited by 533
Parker, G. J. M., Haroon, H. A., & Wheeler‐Kingshott, C. A. M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10350 · Cited by 527
Camino: Open-Source Diffusion-MRI Reconstruction and Processing
Cook, P. A., Bai, Y., Nedjati-Gilani, S., Seunarine, K. K., Hall, M. G., Parker, G. J. M., & Alexander, D. C. (2006) · Cited by 453
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 300
Brain parenchyma motion: measurement with cine echo-planar MR imaging.
Poncelet, B. P., Wedeen, V. J., Weisskoff, R. M., & Cohen, M. S. (1992) · Radiology · doi:10.1148/radiology.185.3.1438740 · Cited by 285
Diffusion tensor imaging using single‐shot SENSE‐EPI
Bammer, R., Auer, M., Keeling, S. L., Augustin, M., Stables, L. A., Prokesch, R. W., Stollberger, R., Moseley, M. E., & Fazekas, F. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10184 · Cited by 279
A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPI
Andersson, J. L. R., & Skare, S. (2002) · NeuroImage · doi:10.1006/nimg.2001.1039 · Cited by 274
Brain motion: measurement with phase-contrast MR imaging.
Enzmann, D. R., & Pelc, N. J. (1992) · Radiology · doi:10.1148/radiology.185.3.1438741 · Cited by 273
Koay, C. G., Chang, L.-C., Carew, J. D., Pierpaoli, C., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.06.020 · Cited by 243
Edelstein, W. A., Bottomley, P. A., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595484 · Cited by 230
Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
Studholme, C., Constable, R. T., & Duncan, J. S. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896788 · Cited by 167
On the effects of gating in diffusion imaging of the brain using single shot EPI
Skare, S. T., & Andersson, J. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00415-5 · Cited by 157
Noise correction for the exact determination of apparent diffusion coefficients at low SNR
Dietrich, O., Heiland, S., & Sartor, K. J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<448::aid-mrm1059>3.0.co;2-w · Cited by 148
Hasan, K. M., Alexander, A. L., & Narayana, P. A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10682 · Cited by 139
Optimal acquisition orders of diffusion‐weighted MRI measurements
Cook, P. A., Symms, M., Boulby, P. A., & Alexander, D. C. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20905 · Cited by 131
Optimized diffusion gradient orientation schemes for corrupted clinical DTI data sets
Dubois, J., Poupon, C., Lethimonnier, F., & Bihan, D. L. (2006) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-006-0036-0 · Cited by 81
Quantification of mechanical vibration during diffusion tensor imaging at 3 T
Hiltunen, J., Hari, R., Jousmäki, V., Müller, K., SEPPONEN, R. E., & Joensuu, R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.004 · Cited by 53
Jones (1999) · doi:10.1002/(sici)1522-2594(199907)42:1<37::aid-mrm7>3.0.co;2-o
Basser (2000) · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o
(1999) · doi:10.1002/1531-8249(199902)45:2<265::aid-ana21>3.0.co;2-3
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Self-citationTamnes, C. K., Østby, Y., Fjell, A. M., Westlye, L. T., Due-Tønnessen, P., & Walhovd, K. B. (2010) · Cerebral Cortex · doi:10.1093/cercor/bhp118 · Cited by 779
Longitudinal Analysis of Neural Network Development in Preterm Infants
Smyser, C. D., Inder, T. E., Shimony, J. S., Hill, J. E., Degnan, A. J., Snyder, A. Z., & Neil, J. J. (2010) · Cerebral Cortex · doi:10.1093/cercor/bhq035 · Cited by 791
Cognitive Sequelae of Traumatic Brain Injury
Rabinowitz, A. R., & Levin, H. S. (2014) · Psychiatric Clinics of North America · doi:10.1016/j.psc.2013.11.004 · Cited by 709
Metadata
- Authors
- Jones, D. K., & Leemans, A.
- Venue
- Methods in Molecular Biology
- Publisher
- Humana Press
- Published
- 2010-12-15
- Volume
- 711
- Pages
- 127-144
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W1873802445
- Cited by
- 379
- References
- 42
- FWCI
- 152.21
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.