The xCELLigence System for Real-Time and Label-Free Monitoring of Cell Viability
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
We describe here the use of the xCELLigence system for label-free and real-time monitoring of cell -viability. The xCELLigence system uses specially designed microtiter plates containing interdigitated gold microelectrodes to noninvasively monitor the viability of cultured cells using electrical impedance as the readout. The continuous monitoring of cell viability by the xCELLigence system makes it possible to distinguish between different perturbations of cell viability, such as senescence, cell toxicity (cell death), and reduced proliferation (cell cycle arrest). In addition, the time resolution of the xCELLigence system allows for the determination of optimal time points to perform standard cell viability assays as well as other end-point assays to understand the mode of action. We have used the WST-1 assay (end-point viability readout), the cell index determination (continuous monitoring of viability by xCELLigence), and the DNA fragmentation assay (end-point apoptosis assay) to systematically examine cytotoxic effects triggered by two cytotoxic compounds with different cell-killing kinetics. Good correlation was observed for viability readouts between WST-1 and cell index. The significance of time resolution by xCELLigence readout is exemplified by its ability to pinpoint the optimal time points for conducting end point viability and apoptosis assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Classification of cell death: recommendations of the Nomenclature Committee on Cell Death 2009
Kroemer, G., Galluzzi, L., Vandenabeele, P., Abrams, J., Alnemri, E. S., Baehrecke, E. H., Blagosklonny, M. V., El-Deiry, W. S., Golstein, P., Green, D. R., et al. (2009) · Cell Death & Differentiation · doi:10.1038/cdd.2008.150 · Cited by 3,399
Scudiero, D. A., Shoemaker, R. H., Paull, K. D., Monks, A. P., Tierney, S., Nofziger, T. H., Currens, M. J., Seniff, D. A., & Boyd, M. R. (1988) · PubMed · Cited by 2,737
Tetrazolium dyes as tools in cell biology: new insights into their cellular reduction
Berridge, M. V., Herst, P. M., & Tan, A. S. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11004-7 · Cited by 2,222
The use of ATP bioluminescence as a measure of cell proliferation and cytotoxicity
Crouch, S. P. M., Kozlowski, R., Slater, K. J., & Fletcher, J. (1993) · Journal of Immunological Methods · doi:10.1016/0022-1759(93)90011-u · Cited by 926
Classification of cell death: recommendations of the Nomenclature Committee on Cell Death
Kroemer, G., El-Deiry, W. S., Golstein, P., Peter, M. E., Vaux, D., Vandenabeele, P., Zhivotovsky, B., Blagosklonny, M. V., Malorni, W., Knight, R. A., et al. (2005) · Cell Death & Differentiation · doi:10.1038/sj.cdd.4401724 · Cited by 843
Weinstein, I. B., & Joe, A. (2008) · Cancer Research · doi:10.1158/0008-5472.can-07-3293 · Cited by 805
Riss, T. L., & Moravec, R. A. (2004) · ASSAY and Drug Development Technologies · doi:10.1089/154065804322966315 · Cited by 370
A novel one-step, highly sensitive fluorometric assay to evaluate cell-mediated cytotoxicity
Nociari, M. M., Shalev, A., Benias, P., & Russo, C. (1998) · Journal of Immunological Methods · doi:10.1016/s0022-1759(98)00028-3 · Cited by 351
Abassi, Y. A., Xi, B., Zhang, W., Ye, P., Kirstein, S. L., Gaylord, M. R., Feinstein, S. C., Wang, X., & Xu, X. (2009) · Chemistry & Biology · doi:10.1016/j.chembiol.2009.05.011 · Cited by 254
Self-citation
Cited by
Xuan, L., Ju, Z., Skonieczna, M., Zhou, P., & Huang, R. (2023) · MedComm · doi:10.1002/mco2.327 · Cited by 807
Study of the in vitro cytotoxicity testing of medical devices
LI, W., ZHOU, J., & XU, Y. (2015) · Biomedical Reports · doi:10.3892/br.2015.481 · Cited by 461
Hu, G.-W., Li, Q., Niu, X., Hu, B., Liu, J., Zhou, S.-M., Guo, S.-C., Lang, H.-L., Zhang, C.-Q., Wang, Y., et al. (2015) · Stem Cell Research & Therapy · doi:10.1186/scrt546 · Cited by 391
Recurrent somatic mutation of FAT1 in multiple human cancers leads to aberrant Wnt activation
Morris, L. G. T., Kaufman, A. M., Gong, Y., Ramaswami, D., Walsh, L. A., Turcan, Ş., Eng, S., Kannan, K., Zou, Y., Peng, L., et al. (2013) · Nature Genetics · doi:10.1038/ng.2538 · Cited by 366
Limame, R., Wouters, A., Pauwels, B., Fransen, E., Peeters, M., Lardon, F., De Wever, O., & Pauwels, P. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046536 · Cited by 300
lnc RNA H19/miR‐675 axis represses prostate cancer metastasis by targeting TGFBI
Zhu, M., Chen, Q., Liu, X., Sun, Q., Zhao, X., Deng, R., Wang, Y., Huang, J., Xu, M., Yan, J., et al. (2014) · The FEBS Journal · doi:10.1111/febs.12902 · Cited by 299
High throughput toxicity screening and intracellular detection of nanomaterials
Collins, A. R., Annangi, B., Rubio, L., Marcos, R., Dorn, M., Merker, C., Estrela‐Lopis, I., Cimpan, M. R., Ibrahim, M., Cimpan, E., et al. (2017) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1413 · Cited by 207
“A microfluidic chip-based IFC developed by Amphasys AG (Switzerland) can analyze single cells without any specific sample preparation prior to measurement.(97,101,102) Compared to other impedance-based cytometers, e.”
MethodLi, D., Liu, X., Zhou, J., Hu, J., Zhang, D., Liu, J., Qiao, Y., & Zhan, Q. (2017) · Hepatology · doi:10.1002/hep.29010 · Cited by 200
“We also examined the function of HULC in cell proliferation by using the xCELLigence System(27) and found that exogenous expression of HULC promoted cell proliferation, while knocking down HULC LI ET AL.”
MethodAswad, H., Forterre, A., Wiklander, O. P. B., Vial, G., Danty-Berger, E., Jalabert, A., Lamazière, A., Meugnier, E., Pesenti, S., Ott, C., et al. (2014) · Diabetologia · doi:10.1007/s00125-014-3337-2 · Cited by 185
“Impedance measurement with the xCELLigence RTCA DP Instrument The effect of exosomes on C2C12 myoblast proliferative capacities wasmonitored with the xCELLigence live cell analysis System (Life Science Roche, Meylan, France), which offers dynamic live cell monitoring [22].”
MethodKho, D., MacDonald, C., Johnson, R., Unsworth, C., O'Carroll, S., Mez, E., Angel, C., & Graham, E. (2015) · Biosensors · doi:10.3390/bios5020199 · Cited by 178
“, cardiotoxicity [32,33]), cell mediated killing [7], toxicology [34] and immunology [8,35]).”
BackgroundForterre, A., Jalabert, A., Berger, E., Baudet, M., Chikh, K., Errazuriz, E., De Larichaudy, J., Chanon, S., Weiss-Gayet, M., Hesse, A.-M., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0084153 · Cited by 177
“Impedance Measurement with the xCELLigence RTCA DP Instrument (Roche) To monitor the effect of C2C12 ELVs on the C2C12 proliferative capacities, we used the xCELLigence live cell analysis System (Roche Applied Science) which offers dynamic live cell monitoring [30].”
Essential steps in bioprinting: From pre- to post-bioprinting
Datta, P., Barui, A., Wu, Y., Ozbolat, V., Moncal, K. K., & Ozbolat, I. T. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.06.003 · Cited by 165
“One of the example is to use microscope for label-free cell viability determination, which should be more widely applied (CadenaHerrera et al., 2015; Ke et al., 2011; Louis and Siegel, 2011).”
MethodIn vitro immunotherapy potency assays using real-time cell analysis
Cerignoli, F., Abassi, Y. A., Lamarche, B. J., Guenther, G., Santa Ana, D., Guimet, D., Zhang, W., Zhang, J., & Xi, B. (2018) · PLOS ONE · doi:10.1371/journal.pone.0193498 · Cited by 105
Self-citationLiberio, M. S., Sadowski, M. C., Soekmadji, C., Davis, R. A., & Nelson, C. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112122 · Cited by 85
E, B., N, E., S, B., S, S., D, S., M, T., S, M., A, B., D, B., D, T., et al. (2020) · Food and Chemical Toxicology · doi:10.1016/j.fct.2020.111713 · Cited by 47
Wlodkowic, D., & Karpiński, T. M. (2021) · Sensors · doi:10.3390/s21217028 · Cited by 28
“Commercial examples of existing ECIS systems that are widely used for laboratory toxicity tests include the xCELLigence (Agilent, Santa Clara, CA, USA), Maestro platform utilising CytoView-Z impedance plates (Axion BioSystems, Atlanta, GA, USA) and Bionas 2500 (Bionas, Rostock, Germany) [142].”
BackgroundMethodPipiya, V. V., Gilazieva, Z. E., Issa, S. S., Rizvanov, A. A., & Solovyeva, V. V. (2024) · Exploration of Targeted Anti-tumor Therapy · doi:10.37349/etat.2024.00237 · Cited by 23
Metadata
- Authors
- Ke, N., Wang, X., Xu, X., & Abassi, Y. A.
- Venue
- Methods in Molecular Biology
- Publisher
- Humana Press
- Published
- 2011
- Volume
- 740
- Pages
- 33-43
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W96287323
- Cited by
- 411
- References
- 17
- FWCI
- 88.84
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.