CoChat

Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes

Williamson, R., Andrews, B. J. · 2001 · Medical & Biological Engineering & Computing

The DOI matches its Crossref record; 14 of the 15 references it cites were found in a registry or an index.

Abstract

Knee joint angle and angular velocity were calculated in real time during standing up and sitting down. Two small modules comprising rate gyroscopes and accelerometers were attached to the thigh and shank of two able-bodied volunteers and one T5 ASIA(A) paraplegic assisted by functional electrical stimulation (FES). The offset and drift of the rate gyroscopes was compensated for by auto-resetting and auto-nulling algorithms. The tilt of the limb segments was calculated by combining the signals of the accelerometer and the rate gyroscope. The joint angle was calculated as the difference in tilt of the segments. The modules were also tested on a two-dimensional model. The mean differences between the rate gyroscope-accelerometer system and the reference goniometer for the model, able-bodied and paraplegic standing trials were 2.1 degrees, 2.4 degrees and 2.3 degrees respectively for knee angle and 2.3 degrees s(-1), 5.0 degrees s(-1) and 11.8 degrees s(-1) respectively for knee velocity. The rate gyroscope-accelerometer system was more accurate than using the accelerometer as a tilt meter, possibly due to the greater bandwidth of the rate gyroscope-accelerometer system.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf02345283

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 14 references

Research works printed but not linked: 2

  1. Andrews, B. J., andWilliamson, R. P. (1997): ‘The gyrogoniometer’, Proc. RESNA '97, pp. 262–264
  2. Kataria, P., andAbbas, J. J. (1998): ‘Estimating body segment orientation using a lightweight, inexpensive gyroscope’. Proc. Biomed. Eng. Soc. Conf. P, S-133

Cited by

Items 101–191 of 191

Metadata

Authors
Williamson, R., & Andrews, B. J.
Affiliations
  • Second Sight Medical Products (US)
  • Stoke Mandeville Hospital (GB)
Corresponding author
Andrews, B. J.
Venue
Medical & Biological Engineering & Computing
Published
2001-05
Volume
39
Issue
3
Pages
294-302
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2018586505
Cited by
185
References
15
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 7 · 2017: 7 · 2016: 13 · 2015: 7 · 2014: 8 · 2013: 12 · 2012: 14
FWCI
3.77
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
Funders
Eunice Kennedy Shriver National Institute of Child Health and Human Development (8R3HD38494A)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
knee joint angle, knee angular velocity, rate gyroscope, accelerometer, inertial measurement unit, paraplegia, functional electrical stimulation, gait analysis, sensor drift correction, goniometer comparison
MeSH terms
Acceleration, Adult, Electric Stimulation Therapy, Female, Gait, Humans, Knee Joint, Male, Paraplegia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.