Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
The DOI matches its Crossref record; 14 of the 15 references it cites were found in a registry or an index.
Abstract
Knee joint angle and angular velocity were calculated in real time during standing up and sitting down. Two small modules comprising rate gyroscopes and accelerometers were attached to the thigh and shank of two able-bodied volunteers and one T5 ASIA(A) paraplegic assisted by functional electrical stimulation (FES). The offset and drift of the rate gyroscopes was compensated for by auto-resetting and auto-nulling algorithms. The tilt of the limb segments was calculated by combining the signals of the accelerometer and the rate gyroscope. The joint angle was calculated as the difference in tilt of the segments. The modules were also tested on a two-dimensional model. The mean differences between the rate gyroscope-accelerometer system and the reference goniometer for the model, able-bodied and paraplegic standing trials were 2.1 degrees, 2.4 degrees and 2.3 degrees respectively for knee angle and 2.3 degrees s(-1), 5.0 degrees s(-1) and 11.8 degrees s(-1) respectively for knee velocity. The rate gyroscope-accelerometer system was more accurate than using the accelerometer as a tilt meter, possibly due to the greater bandwidth of the rate gyroscope-accelerometer system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“| Standing and sitting posture, gait | Knee angle, angular velocity and acceleration | IMU | 193 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [193]
Citations
Cites
Functional Electrical Stimulation: Standing and Walking after Spinal Cord Injury
Kralj, A. R., & Bajd, T. (2021) · Routledge eBooks · doi:10.1201/9780203755402 · Cited by 412
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325
Functional Electrical Stimulation: Standing and Walking After Spinal Cord Injury
Condie, E., & Condie, D. (1990) · Physiotherapy · doi:10.1016/s0031-9406(10)62194-3 · Cited by 317
Miyazaki, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605434 · Cited by 194
Sensors for Use with Functional Neuromuscular Stimulation
Crago, P. E., Chizeck, H. J., Neuman, M. R., & Hambrecht, F. T. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325808 · Cited by 142 · cited 9×
“,c, IFMBE: 2001 goniometer signal could amplify the high frequency noise components. Rate gyroscopes offer an alternative method for monitoring human joint rotations. Previously, real-time detection of angles based on rate gyroscopes was limited due to the zero frequency offset when stationary ( MURATA trade literatur…”
MethodInfluentialAccelerographic analysis of several types of walking.
Smidt, G. L., Arora, J. S., & Johnston, R. C. (1971) · PubMed · Cited by 121
New control strategies for neuroprosthetic systems.
Crago, P. E., Lan, N., Veltink, P. H., Abbas, J. J., & Kantor, C. (1996) · PubMed · Cited by 113
Estimating orientation with gyroscopes and accelerometers
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7612 · Cited by 103
Lower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92 · cited 1×
“(1999) continued the tradition of using accelerometery to detect motion (SMIDT et at., 1971; MORRIS, 1973; SMIDT et at., 1977; WILLEMSEN et at., 1991; HEYN et at., 1996).”
BackgroundRuled-based control of a hybrid FES orthosis for assisting paraplegic locomotion
Andrews, B. J. (1989) · Medical Entomology and Zoology · Cited by 72
Self-citationAn automated accelerometry system for gait analysis
Smidt, G. L., Deusinger, R. H., Arora, J. S., & Albright, J. P. (1977) · Journal of Biomechanics · doi:10.1016/0021-9290(77)90009-4 · Cited by 50
Feedback control system for walking in man
PETROFSKY, J. S., Phillips, C. A., & Heaton, H. H. (1984) · Computers in Biology and Medicine · doi:10.1016/0010-4825(84)90002-7 · Cited by 42 · cited 1×
“MANY CLOSED loop control systems in functional electrical stimulation (FES) systems proposed to improve standing and walking have been based on sensing knee joint angle and angular velocity (PETROFSKY et al., 1984; ANDREWS et al., 1989; MULDER et al., 1992; CRACJO et al., 1996).”
BackgroundLow-level finite state control of knee joint in paraplegic standing
Mulder, A. J., Veltink, P. H., Boom, H. B. K., & Zilvold, G. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90028-j · Cited by 33
The kinematics of the swing phase obtained from accelerometer and gyroscope measurements
Heyn, A., Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.651817 · Cited by 24
Research works printed but not linked: 2
- Andrews, B. J., andWilliamson, R. P. (1997): ‘The gyrogoniometer’, Proc. RESNA '97, pp. 262–264
- Kataria, P., andAbbas, J. J. (1998): ‘Estimating body segment orientation using a lightweight, inexpensive gyroscope’. Proc. Biomed. Eng. Soc. Conf. P, S-133
Cited by
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
“Henceforth, we assume that scale factor and bias errors of gyros in (7a) are constant; in practice, bias errors can be calibrated and compensated effectively by bias capture procedures based on so-called “zero attitude updates,” which require keeping the gyros from rotating [23], [24].”
BackgroundSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
“Inertial sensing has several advantages: the attachment of gyroscopes to the body segments is easier compared with accelerometers, gyroscopes are insensitive to the influence of gravity, the joint angle information is obtained by using only one gyroscope [17], [ 18 ]; additionally, spatial gait parameters can be estim…”
MethodAccelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
“However, concurrent data collection with rate gyroscopes can provide added detail on the orientation of the accelerometer [14–19], and thus enhances the possibility of correcting for the effects of gravity.”
BackgroundMeasuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Metadata
- Authors
- Williamson, R., & Andrews, B. J.
- Affiliations
- Second Sight Medical Products (US)
- Stoke Mandeville Hospital (GB)
- Corresponding author
- Andrews, B. J.
- ORCID
- Andrews, B. J.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2001-05
- Volume
- 39
- Issue
- 3
- Pages
- 294-302
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2018586505
- Cited by
- 185
- References
- 15
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 7 · 2017: 7 · 2016: 13 · 2015: 7 · 2014: 8 · 2013: 12 · 2012: 14
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (8R3HD38494A)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- knee joint angle, knee angular velocity, rate gyroscope, accelerometer, inertial measurement unit, paraplegia, functional electrical stimulation, gait analysis, sensor drift correction, goniometer comparison
- MeSH terms
- Acceleration, Adult, Electric Stimulation Therapy, Female, Gait, Humans, Knee Joint, Male, Paraplegia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.