Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
The DOI matches its Crossref record; 14 of the 15 references it cites were found in a registry or an index.
Abstract
Knee joint angle and angular velocity were calculated in real time during standing up and sitting down. Two small modules comprising rate gyroscopes and accelerometers were attached to the thigh and shank of two able-bodied volunteers and one T5 ASIA(A) paraplegic assisted by functional electrical stimulation (FES). The offset and drift of the rate gyroscopes was compensated for by auto-resetting and auto-nulling algorithms. The tilt of the limb segments was calculated by combining the signals of the accelerometer and the rate gyroscope. The joint angle was calculated as the difference in tilt of the segments. The modules were also tested on a two-dimensional model. The mean differences between the rate gyroscope-accelerometer system and the reference goniometer for the model, able-bodied and paraplegic standing trials were 2.1 degrees, 2.4 degrees and 2.3 degrees respectively for knee angle and 2.3 degrees s(-1), 5.0 degrees s(-1) and 11.8 degrees s(-1) respectively for knee velocity. The rate gyroscope-accelerometer system was more accurate than using the accelerometer as a tilt meter, possibly due to the greater bandwidth of the rate gyroscope-accelerometer system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“| Standing and sitting posture, gait | Knee angle, angular velocity and acceleration | IMU | 193 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [193]
Citations
Cites
Functional Electrical Stimulation: Standing and Walking after Spinal Cord Injury
Kralj, A. R., & Bajd, T. (2021) · Routledge eBooks · doi:10.1201/9780203755402 · Cited by 412
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325
Functional Electrical Stimulation: Standing and Walking After Spinal Cord Injury
Condie, E., & Condie, D. (1990) · Physiotherapy · doi:10.1016/s0031-9406(10)62194-3 · Cited by 317
Miyazaki, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605434 · Cited by 194
Sensors for Use with Functional Neuromuscular Stimulation
Crago, P. E., Chizeck, H. J., Neuman, M. R., & Hambrecht, F. T. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325808 · Cited by 142 · cited 9×
“,c, IFMBE: 2001 goniometer signal could amplify the high frequency noise components. Rate gyroscopes offer an alternative method for monitoring human joint rotations. Previously, real-time detection of angles based on rate gyroscopes was limited due to the zero frequency offset when stationary ( MURATA trade literatur…”
MethodInfluentialAccelerographic analysis of several types of walking.
Smidt, G. L., Arora, J. S., & Johnston, R. C. (1971) · PubMed · Cited by 121
New control strategies for neuroprosthetic systems.
Crago, P. E., Lan, N., Veltink, P. H., Abbas, J. J., & Kantor, C. (1996) · PubMed · Cited by 113
Estimating orientation with gyroscopes and accelerometers
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7612 · Cited by 103
Lower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92 · cited 1×
“(1999) continued the tradition of using accelerometery to detect motion (SMIDT et at., 1971; MORRIS, 1973; SMIDT et at., 1977; WILLEMSEN et at., 1991; HEYN et at., 1996).”
BackgroundRuled-based control of a hybrid FES orthosis for assisting paraplegic locomotion
Andrews, B. J. (1989) · Medical Entomology and Zoology · Cited by 72
Self-citation
Research works printed but not linked: 2
- Andrews, B. J., andWilliamson, R. P. (1997): ‘The gyrogoniometer’, Proc. RESNA '97, pp. 262–264
- Kataria, P., andAbbas, J. J. (1998): ‘Estimating body segment orientation using a lightweight, inexpensive gyroscope’. Proc. Biomed. Eng. Soc. Conf. P, S-133
Cited by
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
“Henceforth, we assume that scale factor and bias errors of gyros in (7a) are constant; in practice, bias errors can be calibrated and compensated effectively by bias capture procedures based on so-called “zero attitude updates,” which require keeping the gyros from rotating [23], [24].”
BackgroundSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
“Inertial sensing has several advantages: the attachment of gyroscopes to the body segments is easier compared with accelerometers, gyroscopes are insensitive to the influence of gravity, the joint angle information is obtained by using only one gyroscope [17], [ 18 ]; additionally, spatial gait parameters can be estim…”
MethodAccelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
“However, concurrent data collection with rate gyroscopes can provide added detail on the orientation of the accelerometer [14–19], and thus enhances the possibility of correcting for the effects of gravity.”
BackgroundMeasuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
“847353 disorders [8]–[11], and mixed and augmented reality [12]–[14].”
BackgroundJasiewicz, J. M., Allum, J. H. J., Middleton, J. W., Barriskill, A., Condie, P., Purcell, B., & Li, R. C. T. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.017 · Cited by 371
“As a result, a variety of prototype sensor systems have been developed for gait analysis [1–8] with the goal of having a completely portable system.”
BackgroundAdvances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349
“In any case, the method was shown to outperform the method based on low-pass filtering the accelerometer signals [4,15], especially as the speed of motion increased.”
BackgroundMethodInertial sensor-based knee flexion/extension angle estimation
Cooper, G., Sheret, I., McMillian, L., Siliverdis, K., Sha, N., Hodgins, D., Kenney, L., & Howard, D. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.004 · Cited by 281
“Furthermore, some researchers have compared their IMU results with less accurate validation instrumentation than the methods used here (e.g. Dejnabadi et al., 2006; Williamson and Andrews, 2001).”
An inertial and magnetic sensor based technique for joint angle measurement
O’Donovan, K. J., Kamnik, R., O’Keeffe, D. T., & Lyons, G. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.010 · Cited by 281
“Various kinematic sensor techniques have been developed for the study of gait analysis (Mayagoitia et al., 2002; Veltink et al., 2003; Williamson and Andrews, 2001), monitoring upper extremity kinematics (Luinge and Veltink, 2005) and mobility monitoring (Lyons et al.”
BackgroundMethodInfluentialCapturing human motion using body‐fixed sensors: outdoor measurement and clinical applications
Aminian, K., & Najafi, B. (2004) · Computer Animation and Virtual Worlds · doi:10.1002/cav.2 · Cited by 280
“Williamson et al.(33) have used Figure 2.”
Development of a wearable sensor system for quantitative gait analysis
Liu, T., Inoue, Y., & Shibata, K. (2009) · Measurement · doi:10.1016/j.measurement.2009.02.002 · Cited by 262
Resistive flex sensors: a survey
Saggio, G., Riillo, F., Sbernini, L., & Quitadamo, L. R. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/1/013001 · Cited by 175
Inertial and magnetic sensing of human motion
Roetenberg, D. (2006) · University of Twente Research Information · Cited by 232
The accuracy of measuring the kinematics of rising from a chair with accelerometers and gyroscopes
Boonstra, M. C., van der Slikke, R. M. A., Keijsers, N., van Lummel, R. C., Malefijt, M. C. D. W., & Verdonschot, N. J. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.11.021 · Cited by 157
Giansanti, D., Maccioni, G., & Macellari, V. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847404 · Cited by 139
Joint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey
Cheng, P., & Oelmann, B. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2024367 · Cited by 140
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundPerformance Evaluation of Smartphone Inertial Sensors Measurement for Range of Motion
Mourcou, Q., Fleury, A., Franco, C., Klopcic, F., & Vuillerme, N. (2015) · Sensors · doi:10.3390/s150923168 · Cited by 138
“To get accurate angle measurement in dynamic, Williamson and Andrews combined accelerometers with gyroscopes, which are insensitive to the influence of gravity [9].”
BackgroundQuaternion-based strap-down integration method for applications of inertial sensing to gait analysis
Sabatini, A. M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345128 · Cited by 123
The Wiimote and Beyond: Spatially Convenient Devices for 3D User Interfaces
Wingrave, C. A., Williamson, B. M., Varcholik, P. D., Rose, J. B., Miller, A. E., Charbonneau, E., Bott, J. N., & LaViola, J. J. (2009) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2009.109 · Cited by 121
“6 Other research has shown that you can combine accelerometers and gyroscopes for accurate position and orientation tracking.(10) In addition, researchers have successfully used Kalman filters to merge accelerometer and gyroscopic data.”
Human pose recovery using wireless inertial measurement units
Lin, J. F. S., & Kulić, D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/12/2099 · Cited by 112
van Lummel, R. C., Walgaard, S., Maier, A. B., Ainsworth, E., Beek, P. J., & van Dieën, J. H. (2016) · PLoS ONE · doi:10.1371/journal.pone.0157968 · Cited by 125
“The acceleration and the angular velocity were used to calculate the trunk angle [30] in the sagittal plane (flexion/extension).”
Methodvan Lummel, R. C., Walgaard, S., Hobert, M. A., Maetzler, W., van Dieën, J. H., Galindo‐Garre, F., & Terwee, C. B. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151881 · Cited by 113
“Maximal flexion angles of the sit to walk and walk to sit were determined using the trunk angle signal [18].”
BackgroundMethodDetermining anatomical frames via inertial motion capture: A survey of methods
Vitali, R. V., & Perkins, N. C. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109832 · Cited by 112
Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system
Liu, K., Liu, T., SHIBATA, K., INOUE, Y., & Zheng, R. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.008 · Cited by 109
“And various kinematic sensor techniques and sensor-based wearable systems have been developed for gait analysis (Mayagoitiaa et al., 2002; Turcot et al., 2008; Kavanagh and Menz, 2008; Nyan et al., 2006; Liu et al., 2008; Williamson and Andrews, 2001).”
MethodGouwanda, D., & Gopalai, A. A. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.12.004 · Cited by 109
A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion
Lee, R. Y. W., Laprade, J., & Fung, E. H. K. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00115-2 · Cited by 99
Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion
Plamondon, A., Delisle, A., Larue, C., Brouillette, D., McFadden, D., Desjardins, P., & Larivière, C. (2007) · Applied Ergonomics · doi:10.1016/j.apergo.2006.12.006 · Cited by 102
Development of a real-time three-dimensional spinal motion measurement system for clinical practice
Goodvin, C., Park, E. J., Huang, K. I., & Sakaki, K. D. R. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0132-3 · Cited by 102
“The feasibility of estimating orientation with gyroscopes and accelerometers, specifically of the lower limb joints has been examined in previous research [16, 13, 18].”
Backgroundvan Lummel, R. C., Ainsworth, E., Lindemann, U., Zijlstra, W., Chiari, L., van Campen, P., & Hausdorff, J. M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.10.008 · Cited by 99
“The acceleration and the angular velocity in the sagittal plane determined the trunk angle (f) [10].”
BackgroundZijlstra, A., Mancini, M., Lindemann, U., Chiari, L., & Zijlstra, W. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-75 · Cited by 92
“In the software, trunk angles in the sagittal plane were calculated using the acceleration and angular velocity data [22].”
MethodKinematics of Gait: New Method for Angle Estimation Based on Accelerometers
Djuric-Jovicic, M. D., Jovičić, N. S., & Popović, D. B. (2011) · Sensors · doi:10.3390/s111110571 · Cited by 86
“) [22-25].”
Inertial Sensors for Human Motion Analysis: A Comprehensive Review
García-de-Villa, S., Casillas-Pérez, D., Jiménez-Martín, A., & García-Domínguez, J. J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3276528 · Cited by 105
“OCs found in the literature that are not related with biomechanical properties include the following: modeling the bias of sensors or including them in the state vector [13], [19], [30], [33], [36], [44], [46], [52], [57], [60], [61], [62], [63], [70], [75], [82], [83], [95], [117], [118], [119], [123], [125], [139],…”
BackgroundMethodKinematics based sensory fusion for wearable motion assessment in human walking
Šlajpah, S., Kamnik, R., & Munih, M. (2013) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.11.012 · Cited by 79
“The presented concept use accelerometer data for continuous fusion, and not just for inclination estimation during quasi-static conditions as presented in many other papers [17–19,24–29,32].”
BackgroundMethodInfluentialBraz, G. P., Russold, M., & Davis, G. M. (2009) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.2009.00213.x · Cited by 88
“Williamson and Andrews tested the accuracy of a rate gyroscope-accelerometer sensor against a reference goniometer (64).”
BackgroundEvoked Electromyography-Based Closed-Loop Torque Control in Functional Electrical Stimulation
Zhang, Q., Hayashibe, M., & Coste, C. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2253777 · Cited by 78
“In some previous studies, the stimulation onset was modulated adapting to the walking speed, ground surface or the user’s intentions through physical sensors such as footswitches [2], accelerometers and gyroscopes [3], through a built-in algorithm [4] or electromyography (EMG) [5].”
MethodEmerging Trends of Body-Mounted Sensors in Sports and Human Gait Analysis
Gouwanda, D., & Senanayake, S. M. N. A. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69139-6_178 · Cited by 76
“In other literatures, error reduction is performed by integrating gyroscope and magnetic sensor into accelerometer unit and introducing sensor fusion algorithm into the system to provide necessary kinematics parameters [ 7 ], [8], [21], [26]”
MethodCavallo, F., Sabatini, A. M., & Genovese, V. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1544967 · Cited by 72
van Lummel, R. C., Evers, J., Niessen, M., Beek, P. J., & van Dieën, J. H. (2018) · Sensors · doi:10.3390/s18041235 · Cited by 76
“The acceleration and the angular velocity in the sagittal plane were used to calculate the trunk pitch angle [32].”
MethodTannous, H., Istrate, D., Benlarbi‐Delaï, A., Sarrazin, J., Gamet, D., Tho, M. H. B., & Dao, T. T. (2016) · Sensors · doi:10.3390/s16111914 · Cited by 67
“used two biaxial accelerometers and two uniaxial gyroscopes, attached to the subject’s thigh and shank, to determine the knee angle using several algorithms [16].”
MethodGiansanti, D., Maccioni, G., Benvenuti, F., & Macellari, V. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0224-8 · Cited by 60
“absolute angle and angular velocity of the human knee during the standing up or the sitting down [ 37 ].”
BackgroundMeasurements of vertical displacement in running, a methodological comparison
Gullstrand, L., Halvorsen, K., Tinmark, F., Eriksson, M., & Nilsson, J. E. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.03.001 · Cited by 60
“As such, they have become a widespread tool in ambulatory measurement systems [10,11].”
BackgroundLiu, K., INOUE, Y., SHIBATA, K., & Enguo, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089454 · Cited by 60
A Fast Quaternion-Based Orientation Optimizer via Virtual Rotation for Human Motion Tracking
Lee, J. K., & Park, E. J. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2001285 · Cited by 60
“Fortunately, the bias errors from the gyro and accelerometer can be captured and compensated effectively for using in-use calibration procedures based on so-called “zero attitude updates” [ 27 ] and “zero velocity updates” [28], respectively.”
Methodvan Uem, J. M. T., Walgaard, S., Ainsworth, E., Hasmann, S. E., Heger, T., Nussbaum, S., Hobert, M. A., Micó-Amigo, M. E., van Lummel, R. C., Berg, D., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151997 · Cited by 64
“The algorithm used in this study has been validated in separate studies [35,36].”
MethodThe Application of Inertial Sensors in Elite Sports Monitoring
James, D. A. (2006) · Springer eBooks · doi:10.1007/978-0-387-45951-6_52 · Cited by 47
“sports environment, complex physical parameters are measured and observed in relation to running and stride characteristics (Herren, Sparti, Aminian and Shultz 1999), and in the determination of gait (Williamson and Andrews 2001).”
BackgroundMoreno, J. C., Brunetti, F., Rocón, E., & Pons, J. L. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0267-x · Cited by 47
“Detection of human knee angle [21] and estimation of human segments’ orientation, [15], combining rate gyroscopes and accelerometers signals, have been proposed.”
Background3D spatial interaction: applications for art, design, and science
LaViola, J. J., & Keefe, D. F. (2011) · ACM SIGGRAPH Courses · doi:10.1145/2037636.2037637 · Cited by 47
“Other research has shown that you can combine accelerometers and gyroscopes for accurate position and orientation tracking [Williamson and Andrews 2001].”
BackgroundJakob, C., Kugler, P., Hebenstreit, F., Reinfelder, S., Jensen, U. J., Schuldhaus, D., Lochmann, M., & Eskofier, B. M. (2013) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets.2013.253613 · Cited by 46
“Three-dimensional gyroscopes can be incorporated to improve the accuracy [15], [6], [23].”
BackgroundClassification of Daily Activities for the Elderly Using Wearable Sensors
Liu, J., Sohn, J.-H., & Kim, S. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/8934816 · Cited by 45
Performance of orientation sensors for use with a functional electrical stimulation mobility system
Simcox, S., Parker, S. P. A., Davis, G. M., Smith, R. W., & Middleton, J. W. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.026 · Cited by 44
Redkar, S. (2017) · International Robotics & Automation Journal · doi:10.15406/iratj.2017.03.00080 · Cited by 46
“angles, knee joint angle was calculated [46].”
BackgroundMethodWiFi/PDR-integrated indoor localization using unconstrained smartphones
Yu, J., Na, Z., Liu, X., & Deng, Z. (2019) · EURASIP Journal on Wireless Communications and Networking · doi:10.1186/s13638-019-1365-9 · Cited by 43
iPhone sensor platforms: Applications to sports monitoring
McNab, T., James, D. A., & Rowlands, D. D. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.05.122 · Cited by 39
“In a dynamic sports environment, complex physical parameters are measured and observed in relation to running and stride characteristics [7], and in the determination of gait [8].”
Lower Limb Exoskeleton Sensors: State-of-the-Art
Neťuková, S., Bejtic, M., Malá, C., Horáková, L., Kutílek, P., Kauler, J., & Krupička, R. (2022) · Sensors · doi:10.3390/s22239091 · Cited by 44
Lim, S. I., & D’Souza, C. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.11.007 · Cited by 42
“Gyroscope data (angular velocity in radians/s) was integrated to obtain angular displacement, and subsequently filtered using a second-order high-pass filter with a cut-off frequency of 0.75 Hz to reduce the effect of drift (Williamson & Andrews, 2001).”
MethodInfluentialGiuberti, M., Ferrari, G., Contin, L., Cimolin, V., Azzaro, C., Albani, G., & Mauro, A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2425296 · Cited by 41
Ambulatory measurement and analysis of the lower limb 3D posture using wearable sensor system
Liu, K., Liu, T., SHIBATA, K., & INOUE, Y. (2009) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2009.5245982 · Cited by 37
“…many wearable sensor system consisting of accelerometers and/or gyroscopes and many novel approaches based on inertial sensors for gait analysis were developed [5] [6] [7], kinematics data for gait analysis such as knee joint angles, thigh and shank orientations were obtained [9] [10] [11].”
BackgroundBody Sensor Networks for Monitoring Rowing Technique
King, R. C., McIlwraith, D. G., Lo, B. P. L., Pansiot, J., McGregor, A. H., & Yang, G. (2009) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.60 · Cited by 35
“A system for measuring knee angle in two dimensions by Williamson and Andrews [12] used auto-resetting and auto-nulling algorithms to compensate for the drift of the gyroscope.”
MethodComparison of three different kinematic sensor assemblies for locomotion study
Giansanti, D., & Maccioni, G. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/010 · Cited by 32
Nonlinear optimization for drift removal in estimation of gait kinematics based on accelerometers
Djuric-Jovicic, M. D., Jovičić, N. S., Popović, D. B., & Djordjevic, A. R. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.08.028 · Cited by 30
“The simplest technique to obtain the angles and to avoid the drift is to use accelerometers as inclinometers (Dejnabadi et al., 2006; Luczak et al., 2006; Williamson and Andrews 2001).”
MethodJoint angle tracking with inertial sensors
El‐Gohary, M., Pearson, S., & McNames, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649344 · Cited by 31
Sensing Power Transfer Between the Human Body and the Environment
Veltink, P. H., Kortier, H. G., & Schepers, H. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2014963 · Cited by 31
“from such sensors [26]–[42].”
McGinnis, R. S., Cain, S. M., Tao, S., Whiteside, D., Goulet, G. C., Gardner, E. C., Bedi, A., & Perkins, N. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2392758 · Cited by 28
van Lummel, R. C., Ainsworth, E., Hausdorff, J. M., Lindemann, U., Beek, P. J., & van Dieën, J. H. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1855 · Cited by 27
Evaluation of a smartphone-based assessment system in subjects with chronic ankle instability
Chiu, Y.-L., Tsai, Y., Lin, C., Hou, Y.-R., & Sung, W.-H. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.11.005 · Cited by 27
Inertial sensor-based humanoid joint state estimation
Rotella, N., Mason, S., Schaal, S., & Righetti, L. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487328 · Cited by 26
Tilt Determination in MEMS Inertial Vestibular Prosthesis
Weinberg, M. S., Wall, C., Robertsson, J., O’Neil, E., Sienko, K. H., & Fields, R. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2378922 · Cited by 26
An unobtrusive swimming monitoring system for recreational and elite performance monitoring
James, D. A., Burkett, B. J., & Thiel, D. V. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.05.060 · Cited by 25
“In the dynamic sports environment, complex physical parameters are measured and observed in relation to running and stride characteristics [7] and in the determination of gait [8].”
BackgroundSensors and Sensor Systems for Psychophysiological Monitoring: A Review of Current Trends
Cutmore, T. R. H., & James, D. A. (2007) · Journal of Psychophysiology · doi:10.1027/0269-8803.21.1.51 · Cited by 30
Mujibiya, A., & Rekimoto, J. (2013) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/2501988.2502031 · Cited by 23
Evaluation of gait parameters for gait phase detection during walking
Senanayake, C., & Senanayake, S. M. N. A. (2010) · IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI) · doi:10.1109/mfi.2010.5604472 · Cited by 22
“More sophisticated techniques such as supervised machine learning techniques [ 6 ] and hybrid intelligent systems [8] could further improve the accuracy of the gait phase detection algorithm.”
MethodMeasurement of three-dimensional welding torch orientation for manual arc welding process
Zhang, W., Xiao, J., Chen, H., & Zhang, Y. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/3/035010 · Cited by 26
Bagalà, F., Fuschillo, V. L., Chiari, L., & Cappello, A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2107897 · Cited by 20
“Several authors [2]–[5], [13], [14], used an inverted pendulum and a quasi-static (QS) model in which the inertial term in (1) is neglected, so the accelerometer output can be approximated as: .”
BackgroundMethodGiant Resistivity Change of Transparent ZnO/Muscovite Heteroepitaxy
Yen, M., Lai, Y.-H., Zhang, C., Cheng, H.-Y., Hsieh, Y.-T., Chen, J.-W., Chen, Y., Chang, L. C., Tsou, N., Li, J., et al. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c02275 · Cited by 20
Wearable Inertial Sensors and Their Applications
Tamura, T. (2014) · Wearable Sensors · doi:10.1016/b978-0-12-418662-0.00024-6 · Cited by 19
Schulze, M., Calließ, T., Gietzelt, M., Wolf, K.-H., Liu, T. H., Seehaus, F., Bocklage, R., Windhagen, H. J., & Marschollek, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346341 · Cited by 19
“Several groups have worked on capturing the body position of a human [9, 10] and detecting the knee angles [11] via inertial sensors.”
BackgroundA distributed MEMS gyro network for joint velocity estimation
Xinjilefu, X., Feng, S.-Y., & Atkeson, C. (2016) · IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2016.7487334 · Cited by 19
“…field of biomechanics, Inertial Measurement Unit (IMU)s are widely used to measure orientation of human body segments [1] and compute knee angles [2] Usually the relative pose between the IMU and body segment is calibrated using some kinematic constraints, and data from each individual IMU is…”
Joint angle estimation with accelerometers for dynamic postural analysis
Ma, J., Kharboutly, H., Benali, A., Amar, F. B., & Bouzit, M. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.08.008 · Cited by 18
“Williamson and Andrews (2001) also used the integration of the gyroscopes signals with accelerometers signals as compensator to estimate the knee angle.”
Quasi-Real Time Estimation of Angular Kinematics Using Single-Axis Accelerometers
Caroselli, A., Bagalà, F., & Cappello, A. (2013) · Sensors · doi:10.3390/s130100918 · Cited by 17
“The accuracy in the joint angles estimation using a single-axis accelerometer (SAA) per segment was comparable with that obtained in several previously published studies where two or more sensors per segment were required [25–30].”
ResultSpECTRUM: Smart ECosystem for sTRoke patient׳s Upper limbs Monitoring
Bobin, M., Bimbard, F., Boukallel, M., Anastassova, M., & Ammi, M. (2019) · Smart Health · doi:10.1016/j.smhl.2019.01.001 · Cited by 18
Joint Angle Measurement Using Strategically Placed Accelerometers and Gyroscope
Vikas, V., & Crane, C. D. (2016) · Journal of Mechanisms and Robotics · doi:10.1115/1.4031299 · Cited by 15
Back to Finger-Writing: Fingertip Writing Technology Based on Pressure Sensing
Blumrosen, G., Sakuma, K., Rice, J. J., & Knickerbocker, J. U. (2020) · IEEE Access · doi:10.1109/access.2020.2973378 · Cited by 15
Biomechanical Ambulatory Assessment of 3D Knee Angle Using Novel Inertial Sensor-Based Technique
Tham, L. K., Osman, N. A. A., Kouzbary, M. A., & Aminian, K. (2021) · IEEE Access · doi:10.1109/access.2021.3062978 · Cited by 15
In the Spotlight: BioInstrumentation
Yamakoshi, K.-I. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2089616 · Cited by 14
Motoi, K., Tanaka, S., Kuwae, Y., Yuji, T., Higashi, Y., Fujimoto, T., & Yamakoshi, K.-I. (2007) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2007.p0656 · Cited by 14
Joint Angle Estimation Using Accelerometer Arrays and Model-Based Filtering
Woods, C., & Vikas, V. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3200251 · Cited by 14
“Another technique estimates the absolute knee angle and angular velocity by using accelerometers to offset errors that occur from the integration of the angular velocity from the gyroscope [5].”
BackgroundMethodSchulze, M., Liu, T.-H., Xie, J., Zhang, W., Wolf, K.-H., Calließ, T., Windhagen, H., & Marschollek, M. (2012) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2012.6211643 · Cited by 12
Kurita, K. (2012) · International Journal of Affective Engineering · doi:10.5057/kei.11.183 · Cited by 12
Lim, S. I., & D’Souza, C. (2020) · Sensors · doi:10.3390/s20185206 · Cited by 12
Overview of Smart White Canes: Connected Smart Cane from Front End to Back End
Motta, G., Ma, T., Liu, K., Pissaloux, E. E., Yusro, M. N., Ramli, K., Connier, J., Vaslin, P., Li, J., de Vaulx, C., et al. (2017) · Springer eBooks · doi:10.1007/978-3-319-54446-5_16 · Cited by 13
A portable device for the clinical assessment of upper limb motion and muscle synergies
Murgia, A., Kerkhofs, V., Savelberg, H. H. C. M., & Meijer, K. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627522 · Cited by 14
“Biomechanical applications have ranged from activity detection [16-18], to gait analysis [ 19- 21 ], to the measurement of shoulder and elbow kinematics with limited relation to function [22].”
BackgroundSharma, N., & Dani, A. P. (2014) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2014.6859342 · Cited by 11
“Limb angle estimation algorithms have employed a Kalman filter [7], a complementary filter [6], an extended Kalman filter [12], [13], and a resetting algorithm to correct drift in a gyroscope [9], [14].”
MethodAn introduction to 3D spatial interaction with video game motion controllers
LaViola, J. J., & Marks, R. L. (2010) · ACM SIGGRAPH Courses · doi:10.1145/1837101.1837103 · Cited by 11
“Other research has shown that you can combine accelerometers and gyroscopes for accurate position and orientation tracking [Williamson and Andrews 2001].”
BackgroundReal time data streaming from smart phones
Rowlands, D. D., & James, D. A. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.05.115 · Cited by 11
“[1-8].”
Attitude-sensor-aided in-process registration of multi-view surface measurement
Shi, C., Zhang, L., Hu, W., & Liu, S. (2010) · Measurement · doi:10.1016/j.measurement.2010.12.003 · Cited by 11
Human Movement Analysis with Inertial Sensors
Lambrecht, S., & del‐Ama, A. J. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-38556-8_16 · Cited by 11
Allen, M., Zhong, Q., Kirsch, N. A., Dani, A. P., Clark, W. W., & Sharma, N. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2748420 · Cited by 10
“However, they are prone to measurement noise, drift, and external interference [4], [9], [12]–[14], and hence without a filtering algorithm IMUs can severely deteriorate estimation accuracy.”
Biogeography-Based Optimization for Hydraulic Prosthetic Knee Control
Wilmot, T. A., Thomas, G., Montavon, B., Rarick, R., van den Bogert, A. J., Szatmary, S., Simon, D. J., Smith, W. A., & Samorezov, S. (2013) · EngagedScholarship @ Cleveland State University (Cleveland State University) · Cited by 10
Metadata
- Authors
- Williamson, R., & Andrews, B. J.
- Affiliations
- Second Sight Medical Products (US)
- Stoke Mandeville Hospital (GB)
- Corresponding author
- Andrews, B. J.
- ORCID
- Andrews, B. J.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2001-05
- Volume
- 39
- Issue
- 3
- Pages
- 294-302
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2018586505
- Cited by
- 185
- References
- 15
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 7 · 2017: 7 · 2016: 13 · 2015: 7 · 2014: 8 · 2013: 12 · 2012: 14
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (8R3HD38494A)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- knee joint angle, knee angular velocity, rate gyroscope, accelerometer, inertial measurement unit, paraplegia, functional electrical stimulation, gait analysis, sensor drift correction, goniometer comparison
- MeSH terms
- Acceleration, Adult, Electric Stimulation Therapy, Female, Gait, Humans, Knee Joint, Male, Paraplegia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.