CoChat

Sleep quality and glycaemic variability in a real-life setting in adults with type 1 diabetes

Open access
Brandt, Rachel, Park, Minsun, Wroblewski, Kristen, Quinn, Lauretta, Tasali, Esra, Cinar, Ali · 2021 · Diabetologia
Cited by 43

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Suboptimal subjective sleep quality is very common in adults with type 1 diabetes. Reducing glycaemic variability is a key objective in this population. To date, no prior studies have examined the associations between objectively measured sleep quality and overnight glycaemic variability in adults with type 1 diabetes. We aimed to test the hypothesis that poor sleep quality would be associated with greater overnight glycaemic variability. Data were collected in the home setting from 20 adults (ten male and ten female participants) with type 1 diabetes who were current insulin pump users. Simultaneous assessments of objective sleep quality (Zmachine Insight+) and continuous glucose monitoring (CGM) were performed over multiple nights (up to 15 nights) in each participant. Due to the real-life nature of this study, the participants kept their usual CGM alerts for out-of-range glucose values. Sleep quality was categorised as ‘good’ or ‘poor’ using a composite of objective sleep features (i.e. sleep efficiency, wake after sleep onset and number of awakenings) based on the National Sleep Foundation’s consensus criteria. Glycaemic variability was quantified using SD and CV of overnight glucose values based on overnight CGM profiles. A total of 170 nights were analysed. Overall, 86 (51%) nights were categorised as good sleep quality, and 84 (49%) nights were categorised as poor sleep quality. Using linear mixed-effects models, poor sleep quality was significantly associated with greater glycaemic variability as quantified by SD (coefficient: 0.39 [95% CI 0.10, 0.67], p = 0.009) and CV (coefficient: 4.35 [95% CI 0.8, 7.9], p = 0.02) of overnight glucose values, after accounting for age, sex, BMI and overnight insulin dose. There was large inter- and intra-individual variability in sleep and glycaemic characteristics. Both pooled and individual-level data revealed that the nights with poor sleep quality had larger SDs and CVs, and, conversely, the nights with good sleep quality had smaller SDs and CVs. No associations were found between sleep quality and time spent in the target glucose range, or above or below the target glucose range, where CGM alarms are most likely to occur. Objectively measured sleep quality is associated with overnight glycaemic variability in adults with type 1 diabetes. These findings highlight an important role of sleep quality in overnight glycaemic control in type 1 diabetes. They also provide a strong incentive to both patients and healthcare providers for considering sleep quality in personalised type 1 diabetes glycaemic management plans. Future studies should investigate the mechanisms linking sleep quality to glycaemic variability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00125-021-05500-9

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 43

Metadata

Authors
Brandt, R., Park, M., Wroblewski, K., Quinn, L., Tasali, E., & Cinar, A.
Venue
Diabetologia
Published
2021-06-17
Volume
64
Issue
10
Pages
2159-2169
ISSN
  • 0012-186X (ISSN-L)
  • 1432-0428
OpenAlex
W3170931697
Cited by
43
References
12
FWCI
3.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.