Non-target screening with high-resolution mass spectrometry: critical review using a collaborative trial on water analysis
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
In this article, a dataset from a collaborative non-target screening trial organised by the NORMAN Association is used to review the state-of-the-art and discuss future perspectives of non-target screening using high-resolution mass spectrometry in water analysis. A total of 18 institutes from 12 European countries analysed an extract of the same water sample collected from the River Danube with either one or both of liquid and gas chromatography coupled with mass spectrometry detection. This article focuses mainly on the use of high resolution screening techniques with target, suspect, and non-target workflows to identify substances in environmental samples. Specific examples are given to emphasise major challenges including isobaric and co-eluting substances, dependence on target and suspect lists, formula assignment, the use of retention information, and the confidence of identification. Approaches and methods applicable to unit resolution data are also discussed. Although most substances were identified using high resolution data with target and suspect-screening approaches, some participants proposed tentative non-target identifications. This comprehensive dataset revealed that non-target analytical techniques are already substantially harmonised between the participants, but the data processing remains time-consuming. Although the objective of a "fully-automated identification workflow" remains elusive in the short term, important steps in this direction have been taken, exemplified by the growing popularity of suspect screening approaches. Major recommendations to improve non-target screening include better integration and connection of desired features into software packages, the exchange of target and suspect lists, and the contribution of more spectra from standard substances into (openly accessible) databases. Graphical Abstract Matrix of identification approach versus identification confidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Open Babel: An open chemical toolbox
O'Boyle, N. M., Banck, M., James, C. A., Morley, C., Vandermeersch, T., & Hutchison, G. R. (2011) · Journal of Cheminformatics · doi:10.1186/1758-2946-3-33 · Cited by 10,939
Sumner, L. W., Amberg, A., Barrett, D., Beale, M. H., Beger, R., Daykin, C. A., Fan, T. W.-M., Fiehn, O., Goodacre, R., Griffin, J. L., et al. (2007) · Metabolomics · doi:10.1007/s11306-007-0082-2 · Cited by 5,368
The National Center for Biotechnology Information
Benson, D., Boguski, M., Lipman, D. J., & Ostell, J. (1990) · Genomics · doi:10.1016/0888-7543(90)90583-g · Cited by 5,126
Identifying Small Molecules via High Resolution Mass Spectrometry: Communicating Confidence
Schymanski, E. L., Jeon, J., Gulde, R., Fenner, K., Ruff, M., Singer, H. P., & Hollender, J. (2014) · Environmental Science & Technology · doi:10.1021/es5002105 · Cited by 4,519 · cited 2×
“Generally, the use of XICs gave more hits because this also captured target and/or suspect substances where the peak was not suitable for the peak picking T bl e 4 R es ul ts su m m ar y fo r L C –H R M S pa rt ic ip an ts ,b ro ke n do w n in to ca te go ri es an d id en tif ic at io n co nf id en ce [7 ]”
BackgroundSelf-citationMassBank: a public repository for sharing mass spectral data for life sciences
Horai, H., Arita, M., Kanaya, S., Nihei, Y., Ikeda, T., Suwa, K., Ojima, Y., Tanaka, K., Tanaka, S., Aoshima, K., et al. (2010) · Journal of Mass Spectrometry · doi:10.1002/jms.1777 · Cited by 2,529
METLIN—a metabolite mass spectral database
Smith, C. A., Maille, G. O., Want, E. J., Qin, C., Trauger, S. A., Brandon, T. R., Custodio, D. E., Abagyan, R., & Siuzdak, G. (2005) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000179845.53213.39 · Cited by 2,226
Registry of mass spectral data
Stenhagen, E., Abrahamsson, S., & McLafferty, F. W. (1974) · Cited by 1,560
National Center for Biotechnology Information
(2019) · Springer Reference Medizin · doi:10.1007/978-3-662-48986-4_301184 · Cited by 1,400
National Institute of Standards and Technology
(1990) · Analytical Chemistry · doi:10.1021/ac00210a736 · Cited by 1,314
Kind, T., & Fiehn, O. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-105 · Cited by 1,201 · cited 1×
“With highaccuracy data, isobaric substances often have the same molecular formula (but not always, because some can have the same exact mass within the instrumental accuracy [65]), and in environmental screening these can often be very similar substances structurally.”
Background
Cited by
The CompTox Chemistry Dashboard: a community data resource for environmental chemistry
Williams, A. J., Grulke, C. M., Edwards, J., McEachran, A. D., Mansouri, K., Baker, N. C., Patlewicz, G., Shah, I., Wambaugh, J. F., Judson, R. S., et al. (2017) · Journal of Cheminformatics · doi:10.1186/s13321-017-0247-6 · Cited by 1,143
MetFrag relaunched: incorporating strategies beyond in silico fragmentation
Ruttkies, C., Schymanski, E. L., Wolf, S., Hollender, J., & Neumann, S. (2016) · Journal of Cheminformatics · doi:10.1186/s13321-016-0115-9 · Cited by 1,052
Self-citationTracking complex mixtures of chemicals in our changing environment
Escher, B. I., Stapleton, H. M., & Schymanski, E. L. (2020) · Science · doi:10.1126/science.aay6636 · Cited by 767
Self-citationNontarget Screening with High Resolution Mass Spectrometry in the Environment: Ready to Go?
Hollender, J., Schymanski, E. L., Singer, H. P., & Ferguson, P. L. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b02184 · Cited by 733
Self-citationDeep Dive into Plastic Monomers, Additives, and Processing Aids
Wiesinger, H., Wang, Z., & Hellweg, S. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c00976 · Cited by 724
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Identification of small molecules using accurate mass MS/MS search
Kind, T., Tsugawa, H., Cajka, T., Ma, Y., Lai, Z., Mehta, S. S., Wohlgemuth, G., Barupal, D. K., Showalter, M. R., Arita, M., et al. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21535 · Cited by 479
Benchmarking the in Vitro Toxicity and Chemical Composition of Plastic Consumer Products
Zimmermann, L., Dierkes, G., Ternes, T. A., Völker, C., & Wagner, M. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b02293 · Cited by 438
Effect-directed analysis supporting monitoring of aquatic environments — An in-depth overview
Brack, W., Ait-Aissa, S., Burgess, R. M., Busch, W., Creusot, N., Di Paolo, C., Escher, B. I., Mark Hewitt, L., Hilscherova, K., Hollender, J., et al. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.11.102 · Cited by 413
Self-citationStrynar, M., Dagnino, S., McMahen, R., Liang, S., Lindstrom, A., Andersen, E., McMillan, L., Thurman, M., Ferrer, I., & Ball, C. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01215 · Cited by 386
CyanoMetDB, a comprehensive public database of secondary metabolites from cyanobacteria
Jones, M. R., Pinto, E., Torres, M. A., Dörr, F., Mazur-Marzec, H., Szubert, K., Tartaglione, L., Dell'Aversano, C., Miles, C. O., Beach, D. G., et al. (2021) · Water Research · doi:10.1016/j.watres.2021.117017 · Cited by 372
Gago-Ferrero, P., Schymanski, E. L., Bletsou, A. A., Aalizadeh, R., Hollender, J., & Thomaidis, N. S. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03454 · Cited by 352
Self-citationBradley, P. M., Journey, C. A., Romanok, K. M., Barber, L. B., Buxton, H. T., Foreman, W. T., Furlong, E. T., Glassmeyer, S. T., Hladik, M. L., Iwanowicz, L. R., et al. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b00012 · Cited by 330
Bridson, J. H., Gaugler, E. C., Smith, D. A., Northcott, G. L., & Gaw, S. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125571 · Cited by 306
Wolfender, J.-L., Nuzillard, J.-M., van der Hooft, J. J. J., Renault, J.-H., & Bertrand, S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05112 · Cited by 305
Dulio, V., van Bavel, B., Brorström-Lundén, E., Harmsen, J., Hollender, J., Schlabach, M., Slobodnik, J., Thomas, K., & Koschorreck, J. (2018) · Environmental Sciences Europe · doi:10.1186/s12302-018-0135-3 · Cited by 287
Self-citationNORMAN guidance on suspect and non-target screening in environmental monitoring
Hollender, J., Schymanski, E. L., Ahrens, L., Alygizakis, N., Béen, F., Bijlsma, L., Brunner, A. M., Celma, A., Fildier, A., Fu, Q., et al. (2023) · Environmental Sciences Europe · doi:10.1186/s12302-023-00779-4 · Cited by 278
Self-citationPlastic Products Leach Chemicals That Induce In Vitro Toxicity under Realistic Use Conditions
Zimmermann, L., Bartosova, Z., Braun, K., Oehlmann, J., Völker, C., & Wagner, M. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c01103 · Cited by 268
Learning from the past and considering the future of chemicals in the environment
Johnson, A. C., Jin, X., Nakada, N., & Sumpter, J. P. (2020) · Science · doi:10.1126/science.aay6637 · Cited by 263
Luo, H., Liu, C., He, D., Sun, J., Li, J., & Pan, X. (2022) · Science of The Total Environment · doi:10.1016/j.scitotenv.2022.157951 · Cited by 258
Gago-Ferrero, P., Bletsou, A. A., Damalas, D. E., Aalizadeh, R., Alygizakis, N. A., Singer, H. P., Hollender, J., & Thomaidis, N. S. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121712 · Cited by 254
“347 target compounds were identified by summing the contribution of all the participants, employing LC and GC based techniques [35].”
MethodSelf-citationLevels and trends of poly- and perfluoroalkyl substances in the Arctic environment – An update
Muir, D., Bossi, R., Carlsson, P., Evans, M., De Silva, A., Halsall, C., Rauert, C., Herzke, D., Hung, H., Letcher, R., et al. (2019) · Emerging Contaminants · doi:10.1016/j.emcon.2019.06.002 · Cited by 209
Neale, P. A., Ait-Aissa, S., Brack, W., Creusot, N., Denison, M. S., Deutschmann, B., Hilscherová, K., Hollert, H., Krauss, M., Novák, J., et al. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b04083 · Cited by 207
Self-citationMcCord, J., & Strynar, M. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b06017 · Cited by 183
“An application of this approach to other watersheds has been effective for other chemical classes, such as surfactants.(23,47) During the course of this study, our monitoring activities resulted in the cessation of discharge from the vinyl ether production at the source manufacturing location, which resulted in a conc…”
BackgroundQuantification for non-targeted LC/MS screening without standard substances
Liigand, J., Wang, T., Kellogg, J., Smedsgaard, J., Cech, N., & Kruve, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-62573-z · Cited by 183
“= ⋅ + RF slope IE intercept log log (5) pred pred”
BackgroundDaughton, C. G. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.03.109 · Cited by 177
Nontarget Screening Reveals Time Trends of Polar Micropollutants in a Riverbank Filtration System
Albergamo, V., Schollée, J. E., Schymanski, E. L., Helmus, R., Timmer, H., Hollender, J., & de Voogt, P. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b01750 · Cited by 118
Self-citationAlygizakis, N., Lestremau, F., Gago-Ferrero, P., Gil-Solsona, R., Arturi, K., Hollender, J., Schymanski, E. L., Dulio, V., Slobodnik, J., & Thomaidis, N. S. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.116944 · Cited by 103
Self-citationNg, K., Alygizakis, N., Androulakakis, A., Galani, A., Aalizadeh, R., Thomaidis, N. S., & Slobodnik, J. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129276 · Cited by 88
Application of Nontarget High Resolution Mass Spectrometry Data to Quantitative Source Apportionment
Peter, K. T., Wu, C., Tian, Z., & Kolodziej, E. P. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b04481 · Cited by 50
Comprehensive Emerging Chemical Discovery: Novel Polyfluorinated Compounds in Lake Michigan Trout
Fakouri Baygi, S., Crimmins, B. S., Hopke, P. K., & Holsen, T. M. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b01349 · Cited by 49
Metadata
- Authors
- Schymanski, E. L., Singer, H. P., Slobodnik, J., Ipolyi, I. M., Oswald, P., Krauss, M., Schulze, T., Haglund, P., Letzel, T., Grosse, S., Thomaidis, N. S., Bletsou, A., Zwiener, C., Ibáñez, M., Portolés, T., de Boer, R., Reid, M. J., Onghena, M., Kunkel, U., Schulz, W., Guillon, A., Noyon, N., Leroy, G., Bados, P., Bogialli, S., Stipaničev, D., Rostkowski, P., & Hollender, J.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2015-05-15
- Volume
- 407
- Issue
- 21
- Pages
- 6237-6255
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2112806519
- Cited by
- 703
- References
- 44
- FWCI
- 19.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.