Vitamin D Assays: Past and Present Debates, Difficulties, and Developments
The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
Structure-Function Relationships in the Vitamin D Endocrine System*
BOUILLON, R., OKAMURA, W. H., & NORMAN, A. W. (1995) · Endocrine Reviews · doi:10.1210/edrv-16-2-200 · Cited by 1,235 · cited 1×
“There are well over 40 metabolites of vitamin D identified [1], and this could potentially result in difficulties in establishing assays for specific molecules of interest.”
Pharmacokinetics of vitamin D toxicity
Jones, G. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/88.2.582s · Cited by 927 · cited 1×
“The most potent physiologically active circulating metabolite produced by humans is 1,25-dihdroxyvitamin D (1,25[OH]2D), which has a half-life of 4–15 h [5–8]; and while 25OHD circulates in nanomole per liter concentrations, 1,25(OH)2D is present in picomole per liter concentrations, which means that 1,25(OH)2D repres…”
COMPETITIVE PROTEIN-BINDING RADIOASSAY FOR 25-HYDROXYCHOLECALCIFEROL1
Haddad, J. G., & Chyu, K. J. (1971) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-33-6-992 · Cited by 905 · cited 1×
“In the 1970s a pivotal method [13] was developed that employed preliminary solvent extraction of samples and chromatographic purification, resulting in elimination of VDBP.”
Extrarenal Expression of 25-Hydroxyvitamin D3-1α-Hydroxylase1
Zehnder, D., Bland, R., Williams, M. C., McNinch, R. W., Howie, A. J., Stewart, P. M., & Hewison, M. (2001) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.86.2.7220 · Cited by 855
REINHARDT, T. A., HORST, R. L., ORF, J. W., & HOLLIS, B. W. (1984) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-58-1-91 · Cited by 801 · cited 1×
“5 pg/mL), in chronic renal failure [66].”
Singh, R. J., Taylor, R. L., Reddy, G. S., & Grebe, S. K. G. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0710 · Cited by 478 · cited 1×
“Although mainly seen in younger children [50] and in specific disease states, a recent report has claimed that 3-epi-25OHD3 is present in 99 % of samples tested, with concentrations ranging from 0.”
Determination of vitamin D status by radioimmunoassay with an 125I-labeled tracer
Hollis, B. W., Kamerud, J. Q., Selvaag, S. R., Lorenz, J. D., & Napoli, J. L. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.3.529 · Cited by 432 · cited 1×
“Immunoassay methods were first reported in the 1980s with a radioimmunoassay (RIA) described that initially utilized a (3)H-labeled 25OHD tracer [23], which was subsequently developed into a (125)I-labeled 25OHD assay with higher throughput and improved performance [24].”
MethodLow circulating vitamin D in obesity
Liel, Y., Ulmer, E., Shary, J., Hollis, B. W., & Bell, N. H. (1988) · Calcified Tissue International · doi:10.1007/bf02555135 · Cited by 387 · cited 1×
“Improvements in HPLC methods centered around the introduction of reversed-phase HPLC mainly using C18 columns [37], improved internal standard material, improved sample extraction using chloroform–methanol [32] and methanol–hexane [38], then extraction of samples using semiautomated technology employing acetonitrile p…”
Maunsell, Z., Wright, D. J., & Rainbow, S. J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.052936 · Cited by 382
Farrell, C.-J. L., Martin, S., McWhinney, B., Straub, I., Williams, P., & Herrmann, M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.172155 · Cited by 373 · cited 1×
“Evaluation of these automated assays has raised concerns about increased variability in performance with wider CVs [57], poor cross-reactivity with 25OHD2 [58], inaccuracy of results [28], interference from heterophilic antibodies requiring a reformulation of the assay [59], and failure to achieve minimal performance…”
Heijboer, A. C., Blankenstein, M. A., Kema, I. P., & Buijs, M. M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.176545 · Cited by 339 · cited 2×
“Evaluation of these automated assays has raised concerns about increased variability in performance with wider CVs [57], poor cross-reactivity with 25OHD2 [58], inaccuracy of results [28], interference from heterophilic antibodies requiring a reformulation of the assay [59], and failure to achieve minimal performance…”
Carter, G. D., Carter, R., Jones, J., & Berry, J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.040683 · Cited by 306
Preece, M. A., O'Riordan, J. L. H., Lawson, D. E. M., & Kodicek, E. (1974) · Clinica Chimica Acta · doi:10.1016/0009-8981(74)90241-1 · Cited by 298
Extrarenal Expression of 25-Hydroxyvitamin D3-1 -Hydroxylase
Zehnder, D. (2001) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.86.2.888 · Cited by 282
Tai, S. S.-C., Bedner, M., & Phinney, K. W. (2010) · Analytical Chemistry · doi:10.1021/ac9026862 · Cited by 271 · cited 1×
“In 2011 a reference method [56] was recognized by the Joint Committee for Traceability in Laboratory Medicine, and a further reference method accepted by European authorities has been published recently [55].”
MethodVitamin D Metabolites and Calcium Absorption in Severe Vitamin D Deficiency
Need, A. G., O'Loughlin, P. D., Morris, H. A., Coates, P. S., Horowitz, M., & Nordin, B. C. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080607 · Cited by 263 · cited 1×
“For these reasons, as well as the short half-life, total 1,25(OH)2D is a poor indicator of overall vitamin D status as total 25OHD needs to decrease to around 10 nmol/L (4 ng/mL) for total 1,25(OH)2D to decrease significantly [12].”
Analytical and clinical validation of the 25 OH vitamin D assay for the LIAISON® automated analyzer
Ersfeld, D. L., Rao, D. S., Body, J.-J., Sackrison, J. L., Miller, A. B., Parikh, N., Eskridge, T. L., Polinske, A., Olson, G. T., & MacFarlane, G. D. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.06.006 · Cited by 243 · cited 1×
“This assay formed the basis for a subsequent chemiluminescent detection–based system, which has been automated [25].”
HPLC Method for 25-Hydroxyvitamin D Measurement: Comparison with Contemporary Assays
Lensmeyer, G. L., Wiebe, D. A., Binkley, N., & Drezner, M. K. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.064956 · Cited by 239 · cited 1×
“Improvements in HPLC methods centered around the introduction of reversed-phase HPLC mainly using C18 columns [37], improved internal standard material, improved sample extraction using chloroform–methanol [32] and methanol–hexane [38], then extraction of samples using semiautomated technology employing acetonitrile p…”
COMPETITIVE BINDING ASSAY FOR VITAMIN D AND 25-OH VITAMIN D*
BELSEY, R., DELUCA, H. F., & POTTS, J. T. (1971) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-33-3-554 · Cited by 234 · cited 1×
“10 days) and measurement across a wide range of concentrations [14–18].”
Stepman, H. C., Vanderroost, A., Van Uytfanghe, K., & Thienpont, L. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.152553 · Cited by 203 · cited 1×
“In 2011 a reference method [56] was recognized by the Joint Committee for Traceability in Laboratory Medicine, and a further reference method accepted by European authorities has been published recently [55].”
MethodAronov, P. A., Hall, L. M., Dettmer, K., Stephensen, C. B., & Hammock, B. D. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2095-8 · Cited by 197 · cited 1×
“Derivitization using 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD), a Cooksontype reagent, of a SPE sample and measurement using ultraperformance liquid chromatography (UPLC) electrospray tandem MS allowed simultaneous quantification of a profile of vitamin D metabolites (1,25[OH]2D2, 1,25[OH]2D3, 24,25[OH]2D3, 25OHD2, a…”
MethodCompetitive Protein-Binding Assay for 25-Hydroxycholecalciferol
Edelstein, S., Charman, M., Lawson, D. E. M., & Kodicek, E. (1974) · Clinical Science · doi:10.1042/cs0460231 · Cited by 194 · cited 1×
“10 days) and measurement across a wide range of concentrations [14–18].”
Eisman, J. A., Shepard, R. M., & DeLuca, H. F. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90648-0 · Cited by 186 · cited 1×
“The first direct UV detection–based HPLC assays for 25OHD were published in 1977 [35, 36].”
Circulating 25-hydroxyvitamin D in man
Haddad, J. G., & Stamp, T. C. B. (1974) · The American Journal of Medicine · doi:10.1016/0002-9343(74)90768-2 · Cited by 182 · cited 1×
“(vitamin D) [9, 10] and is the reason the well-recognized seasonal variability related to UVB exposure exists.”
The C-3 Epimer of 25-Hydroxyvitamin D3Is Present in Adult Serum
Lensmeyer, G., Poquette, M., Wiebe, D., & Binkley, N. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-0584 · Cited by 177 · cited 1×
“25 nmol/ L in samples from neonates to 80?-year-old adults [51].”
Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobars
Shah, I., James, R. A., Barker, J., Petróczi, A., & Naughton, D. P. (2011) · Nutrition Journal · doi:10.1186/1475-2891-10-46 · Cited by 167 · cited 1×
“Isobars of 25OHD metabolites which can cause isobaric interference, have also been reported in a small number of subjects [54]; but their clinical importance and contribution to 25OHD measurement need to be investigated further.”
Hollis, B. W. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.10.1657 · Cited by 165
CLEMENS, T. L., ZHOUf, X.-Y., MYLES, M., ENDRES, D., & LINDSAY, R. (1986) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-63-3-656 · Cited by 158 · cited 1×
“Although the parent sterol vitamin D has a half-life of close to 24 h [2], this is relatively short compared with 25-hydroxyvitamin D (25OHD), which has a half-life of 21–30 days [3, 4].”
NHANES Monitoring of Serum 25-Hydroxyvitamin D: A Roundtable Summary
Yetley, E. A. D., Pfeiffer, C. M., Schleicher, R. L., Phinney, K. W., Lacher, D. A., Christakos, S., Eckfeldt, J. H., Fleet, J. C., Howard, G., Hoofnagle, A. N., et al. (2010) · Journal of Nutrition · doi:10.3945/jn.110.121483 · Cited by 155
Shepard, R. M., & DeLuca, H. F. (1980) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(80)90404-x · Cited by 151 · cited 1×
“(vitamin D) [9, 10] and is the reason the well-recognized seasonal variability related to UVB exposure exists.”
Quantification of circulating 1,25-dihydroxyvitamin D by radioimmunoassay with 125I-labeled tracer
Hollis, B. W., Kamerud, J., Kurkowski, A., Beaulieu, J., & Napoli, J. L. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.4.586 · Cited by 145 · cited 3×
“Human serum stripped of 1,25(OH)2D3 by activated charcoal can then be used to make calibrators of varying concentrations by adding dissolved 1,25(OH)2D3 [71].”
MethodMeasurement of 25-hydroxyvitamin D3 in serum.
Bouillon, R., Kerkhove, P. V., & MOOR, P. D. (1976) · Clinical Chemistry · doi:10.1093/clinchem/22.3.364 · Cited by 140 · cited 1×
“10 days) and measurement across a wide range of concentrations [14–18].”
Intestinal Cholecalciferol Absorption in the Elderly and in Younger Adults
Barragry, J. M., France, M. W., Corless, D., Gupta, S. P., Switala, S., Boucher, B. J., & Cohen, R. D. (1978) · Clinical Science · doi:10.1042/cs0550213 · Cited by 136 · cited 1×
“Although the parent sterol vitamin D has a half-life of close to 24 h [2], this is relatively short compared with 25-hydroxyvitamin D (25OHD), which has a half-life of 21–30 days [3, 4].”
Tsugawa, N., Suhara, Y., Kamao, M., & Okano, T. (2005) · Analytical Chemistry · doi:10.1021/ac048249c · Cited by 136 · cited 1×
“Isotope dilution-electrospray LC-MS/MS methods performed on ‘‘bench top’’ analyzers became popular in the mid-2000s with protein precipitation of the sample, liquid– liquid extraction, short run times, and computer processing of chromatograms contributing to higher throughput and ease of use [41–43].”
25-Hydroxyvitamin D: A Difficult Analyte
Carter, G. D. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.180562 · Cited by 135 · cited 1×
“immunoassays do not cross-react with 3-epi-25OHD3 [52].”
Vogeser, M., Kyriatsoulis, A., Huber, E., & Kobold, U. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.031831 · Cited by 129 · cited 1×
“Isotope dilution-electrospray LC-MS/MS methods performed on ‘‘bench top’’ analyzers became popular in the mid-2000s with protein precipitation of the sample, liquid– liquid extraction, short run times, and computer processing of chromatograms contributing to higher throughput and ease of use [41–43].”
Phinney, K. W., Bedner, M., Tai, S. S.-C., Vamathevan, V. V., Sander, L. C., Sharpless, K. E., Wise, S. A., Yen, J. H., Schleicher, R. L., Chaudhary-Webb, M., et al. (2012) · Analytical Chemistry · doi:10.1021/ac202047n · Cited by 128 · cited 2×
“Value assignment of SRM 972 was accomplished using a combination of three isotope-dilution MS approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention [63] .”
Chen, H., McCoy, L. F., Schleicher, R. L., & Pfeiffer, C. M. (2008) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.01.017 · Cited by 125 · cited 1×
“Recent technical developments have centered around reducing the manual component of sample preparation prior to chromatography and elimination of liquid–liquid extraction using either separate automated solid-phase extraction (SPE) [45], online solid-phase extraction [46, 47], or online turbulent flow extraction [48].”
Strathmann, F. G., Laha, T. J., & Hoofnagle, A. N. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161174 · Cited by 125
Metabolism and Excretion of3H-1,2 5-(OH)2-Vitamin D3in Healthy Adults*
Gray, R. W., CALDAS, A. E., Wilz, D. R., et al. (1978) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-46-5-756 · Cited by 122
Glendenning, P., Taranto, M., Noble, J., Musk, A., Hammond, C., Goldswain, P., Fraser, W., & Vasikaran, S. (2006) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456306775141650 · Cited by 122 · cited 1×
“In a Vitamin D2 (ergocalciferol) supplementation study, venous sampling following oral administration of Vitamin D2 demonstrated a significant underestimation of 25OHD2 by three immunoassays [21].”
Self-citationSchleicher, R. L., Encisco, S. E., Chaudhary‐Webb, M., Paliakov, E. M., McCoy, L. F., & Pfeiffer, C. M. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.05.010 · Cited by 113
Duan, X., Weinstock‐Guttman, B., Wang, H., Bang, E., Li, J., Ramanathan, M. K., & Qu, J. (2010) · Analytical Chemistry · doi:10.1021/ac902869y · Cited by 106 · cited 1×
“same four metabolites with significantly improved sensitivity, 5 ng/L (12 pmol/L) for 1,25(OH)2D3, that employed selective SPE and microflow LC-MS/MS [80].”
Proficiency testing of 25-Hydroxyvitamin D (25-OHD) assays
Carter, G. D., Berry, J., Gunter, E. W., Jones, G., Jones, J. C., Makin, H. L. J., Sufi, S., & Wheeler, M. J. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.03.033 · Cited by 103 · cited 1×
“4 % of the ALTM (2009) [64].”
Binkley, N., Krueger, D. C., Morgan, S., & Wiebe, D. A. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.08.018 · Cited by 102 · cited 1×
“Reports have confirmed the variability of commercial immunoassays to detect 25OHD2 [21, 29–31], and this is postulated to be due to differing”
Carter, G. D., & Jones, J. C. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008135 · Cited by 99 · cited 1×
“While the use of a commercially available common standard material can improve the consistency of performance of LC-MS/MS, the provenance of this material remains in doubt [61] and the subsequent benefit of the approach questioned [62].”
Knox, S., Harris, J., Calton, L. J., & Wallace, A. M. (2009) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2009.008206 · Cited by 90 · cited 7×
“The SPE procedure enabled high sample loading on the UPLC column , and on-column sample focusing prevented band broadening, allowing excellent separation and eliminating endogenous interference while minimizing ion suppression but with a run time of 27 min.”
InfluentialCasetta, B., Jans, I., Billen, J., Vanderschueren, D., & Bouillon, R. (2010) · European Journal of Mass Spectrometry · doi:10.1255/ejms.1024 · Cited by 85 · cited 1×
“Lithium acetate has been used to produce ionizable adducts in a method that uses a complex online sample processing procedure with the use of a perfusion column followed by a chain of two monolithic columns to clean and enrich the sample prior to quantification on a highly sensitive LC-MS/MS [81].”
Measurement of circulating vitamin D in man
Clemens, T. L., Actams, J. S., Nolan, J. M., & Holick, M. F. (1982) · Clinica Chimica Acta · doi:10.1016/0009-8981(82)90239-x · Cited by 77 · cited 1×
“Although the parent sterol vitamin D has a half-life of close to 24 h [2], this is relatively short compared with 25-hydroxyvitamin D (25OHD), which has a half-life of 21–30 days [3, 4].”
Hyppönen, E., Turner, S., Cumberland, P. M., Power, C., & Gibb, I. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-1279 · Cited by 75 · cited 1×
“A two-step extraction RIA [26] was produced by one commercial manufacturer and subsequently developed into an enzyme immunoassay (EIA) without the extraction step, which could also be automated [27].”
25-Hydroxyvitamin D Measurement, 2009: A Review for Clinicians
Binkley, N., Krueger, D. C., & Lensmeyer, G. L. (2009) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2009.06.001 · Cited by 74 · cited 1×
“Reports have confirmed the variability of commercial immunoassays to detect 25OHD2 [21, 29–31], and this is postulated to be due to differing”
Yuan, C., Kosewick, J., He, X. H., Kozak, M., & Wang, S. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4988 · Cited by 65
Glendenning, P., Noble, J. M., Taranto, M., Musk, A. A., McGuiness, M., Goldswain, P., Fraser, W. D., & Vasikaran, S. D. (2003) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456303322326470 · Cited by 64 · cited 1×
“made to automate a CPB-based assay, this proved problematic, with inaccuracy, poor detection limit, low crossreactivity with 25OHD2, poor precision, and overall unacceptable performance [20–22].”
Self-citationNetzel, B. C., Cradic, K. W., Bro, E. T., Girtman, A., Cyr, R. C., Singh, R. J., & Grebe, S. K. G. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.157115 · Cited by 60 · cited 2×
“Future developments will likely incorporate more online processing, automated sample preparation, and mass tagging [49] to increase throughput.”
Bunch, D. R., Miller, A., & Wang, S. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.342 · Cited by 49 · cited 1×
“Recent technical developments have centered around reducing the manual component of sample preparation prior to chromatography and elimination of liquid–liquid extraction using either separate automated solid-phase extraction (SPE) [45], online solid-phase extraction [46, 47], or online turbulent flow extraction [48].”
Turner, C., Dalton, N. R., Inaoui, R., Fogelman, I., Fraser, W. D., & Hampson, G. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-2790 · Cited by 47 · cited 1×
“The LC-MS/MS method detected a significant increase in total 1,25(OH)2D, mainly due to an increase in 1,25(OH)2D2; but the immunoassay failed to detect this increase in 1,25(OH)D [84].”
Self-citationSpecific estimation of 24,25-dihydroxyvitamin D in plasma by gas chromatography-mass spectrometry.
Coldwell, R. D., Trafford, D. J. H., Makin, H. L. J., Varley, M. J., & KIRK, D. N. (1984) · Clinical Chemistry · doi:10.1093/clinchem/30.7.1193 · Cited by 38 · cited 1×
“Concentrations in the region of 10–15 nmol/L have been recorded for 24,25(OH)2D in serum using gas chromatography-MS [34], with reported circulation levels of 10–15 % that of 25OHD.”
Evaluation of 25-hydroxy vitamin D assay on the immunodiagnostic systems iSYS analyser
Cluse, Z. N., Fudge, A., Whiting, M. J., McWhinney, B. C., Parkinson, I. H., & O’Loughlin, P. D. (2011) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2011.011018 · Cited by 33 · cited 5×
“Evaluation of these automated assays has raised concerns about increased variability in performance with wider CVs [57], poor cross-reactivity with 25OHD2 [58], inaccuracy of results [28], interference from heterophilic antibodies requiring a reformulation of the assay [59], and failure to achieve minimal performance…”
InfluentialPapapoulos, S. E., Clemens, T. L., Sandler, L. M., Fraher, L. J., Winer, J. B., & O'Riordan, J. L. H. (1982) · Clinical Science · doi:10.1042/cs0620427 · Cited by 23 · cited 1×
“The most potent physiologically active circulating metabolite produced by humans is 1,25-dihdroxyvitamin D (1,25[OH]2D), which has a half-life of 4–15 h [5–8]; and while 25OHD circulates in nanomole per liter concentrations, 1,25(OH)2D is present in picomole per liter concentrations, which means that 1,25(OH)2D repres…”
Standardization of vitamin D assays: art or science?
Fraser, W. D. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008225 · Cited by 17 · cited 1×
“While the use of a commercially available common standard material can improve the consistency of performance of LC-MS/MS, the provenance of this material remains in doubt [61] and the subsequent benefit of the approach questioned [62].”
Self-citation
Cited by
Vitamin D for health: a global perspective
Hossein-nezhad, A., & Holick, M. F. (2013) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2013.05.011 · Cited by 1,298
“Standardization of all assays has been improved but not resolved with the currently available reference materials, as evidenced by the Vitamin D External Quality Assessment Scheme.(222) The choice of method for each laboratory remains a balance mainly among turnaround time, convenience, cost, and the specificity and a…”
Vitamin D Sources, Metabolism, and Deficiency: Available Compounds and Guidelines for Its Treatment
Dominguez, L. J., Farruggia, M., Veronese, N., & Barbagallo, M. (2021) · Metabolites · doi:10.3390/metabo11040255 · Cited by 299
Vitamin D and Cancer Risk and Mortality: State of the Science, Gaps, and Challenges
Mondul, A. M., Weinstein, S. J., Layne, T. M., & Albanes, D. (2017) · Epidemiologic Reviews · doi:10.1093/epirev/mxx005 · Cited by 174
Johnsen, M. S., Grimnes, G., Figenschau, Y., Torjesen, P. A., Almås, B., & Jorde, R. (2014) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2013.869701 · Cited by 112
Case for the wider adoption of mass spectrometry-based adrenal steroid testing, and beyond
Monaghan, P. J., Keevil, B. G., Stewart, P. M., & Trainer, P. J. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2258 · Cited by 41
Metadata
- Authors
- Fraser, W. D., & Milan, A. M.
- Venue
- Calcified Tissue International
- Published
- 2013-01-13
- Volume
- 92
- Issue
- 2
- Pages
- 118-127
- ISSN
- 0171-967X (ISSN-L)
- 1432-0827
- OpenAlex
- W1987972939
- Cited by
- 160
- References
- 61
- FWCI
- 14.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.