The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Principles of ultrasound elastography
Open accessAbstract
Tissue stiffness has long been known to be a biomarker of tissue pathology. Ultrasound elastography measures tissue mechanical properties by monitoring the response of tissue to acoustic energy. Different elastographic techniques have been applied to many different tissues and diseases. Depending on the pathology, patient-based factors, and ultrasound operator-based factors, these techniques vary in accuracy and reliability. In this review, we discuss the physical principles of ultrasound elastography, discuss differences between different ultrasound elastographic techniques, and review the advantages and disadvantages of these techniques in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Non-invasive evaluation of liver fibrosis using transient elastography
Castera, L., Forns, X., & Alberti, A. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.02.008 · Cited by 1,430
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Ultrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052
Shiina, T., Nightingale, K. R., Palmeri, M. L., Hall, T. J., Bamber, J. C., Barr, R. G., Castera, L., Choi, B. I., Chou, Y.-H., Cosgrove, D., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.009 · Cited by 958
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
WFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 3: Liver
Ferraioli, G., Filice, C., Castera, L., Choi, B. I., Sporea, I., Wilson, S. R., Cosgrove, D., Dietrich, C. F., Amy, D., Bamber, J. C., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.007 · Cited by 879
Sasso, M., Beaugrand, M., de Ledinghen, V., Douvin, C., Marcellin, P., Poupon, R., Sandrin, L., & Miette, V. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.005 · Cited by 862
Fraquelli, M., Rigamonti, C., Casazza, G., Conte, D., Donato, M. F., Ronchi, G., & Colombo, M. (2007) · Gut · doi:10.1136/gut.2006.111302 · Cited by 854
Acute viral hepatitis increases liver stiffness values measured by transient elastography
Arena, U., Vizzutti, F., Corti, G., Ambu, S., Stasi, C., Bresci, S., Moscarella, S., Boddi, V., Petrarca, A., Laffi, G., et al. (2008) · Hepatology · doi:10.1002/hep.22007 · Cited by 754
Tsochatzis, E. A., Gurusamy, K. S., Ntaoula, S., Cholongitas, E., Davidson, B. R., & Burroughs, A. K. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.07.033 · Cited by 709
Ferraioli, G., Tinelli, C., Dal Bello, B., Zicchetti, M., Filice, G., Filice, C., & on behalf of the Liver Fibrosis Study Group (2012) · Hepatology · doi:10.1002/hep.25936 · Cited by 667
WFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 2: Breast
Barr, R. G., Nakashima, K., Amy, D., Cosgrove, D., Farrokh, A., Schafer, F., Bamber, J. C., Castera, L., Choi, B. I., Chou, Y.-H., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.008 · Cited by 474
Shear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Bojunga, J., Herrmann, E., Meyer, G., Weber, S., Zeuzem, S., & Friedrich-Rust, M. (2010) · Thyroid® · doi:10.1089/thy.2010.0079 · Cited by 309
Takuma, Y., Nouso, K., Morimoto, Y., Tomokuni, J., Sahara, A., Toshikuni, N., Takabatake, H., Shimomura, H., Doi, A., Sakakibara, I., et al. (2013) · Gastroenterology · doi:10.1053/j.gastro.2012.09.049 · Cited by 258
Diagnostic Performance of Gray-Scale US and Elastography in Solid Thyroid Nodules
Moon, H. J., Sung, J. M., Kim, E.-K., Yoon, J. H., Youk, J. H., & Kwak, J. Y. (2012) · Radiology · doi:10.1148/radiol.11110839 · Cited by 251
Elkrief, L., Rautou, P.-E., Ronot, M., Lambert, S., Dioguardi Burgio, M., Francoz, C., Plessier, A., Durand, F., Valla, D., Lebrec, D., et al. (2015) · Radiology · doi:10.1148/radiol.14141210 · Cited by 236
Elastography in Chronic Liver Disease: Modalities, Techniques, Limitations, and Future Directions
Srinivasa Babu, A., Wells, M. L., Teytelboym, O. M., Mackey, J. E., Miller, F. H., Yeh, B. M., Ehman, R. L., & Venkatesh, S. K. (2016) · RadioGraphics · doi:10.1148/rg.2016160042 · Cited by 212
De Lédinghen, V., Vergniol, J., Foucher, J., El-Hajbi, F., Merrouche, W., & Rigalleau, V. (2010) · Liver International · doi:10.1111/j.1478-3231.2010.02258.x · Cited by 205
Samir, A. E., Dhyani, M., Vij, A., Bhan, A. K., Halpern, E. F., Méndez-Navarro, J., Corey, K. E., & Chung, R. T. (2015) · Radiology · doi:10.1148/radiol.14140839 · Cited by 205
Self-citationDiffraction field of a low frequency vibrator in soft tissues using transient elastography
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.775668 · Cited by 167
Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave Elastography
Correas, J.-M., Tissier, A.-M., Khairoune, A., Vassiliu, V., Méjean, A., Hélénon, O., Memo, R., & Barr, R. G. (2015) · Radiology · doi:10.1148/radiol.14140567 · Cited by 165
Li, Y., Huang, Y.-S., Wang, Z.-Z., Yang, Z.-R., Sun, F., Zhan, S.-Y., Liu, X.-E., & Zhuang, H. (2016) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.13488 · Cited by 161
Portal Hypertension in Patients with Liver Cirrhosis: Diagnostic Accuracy of Spleen Stiffness
Takuma, Y., Nouso, K., Morimoto, Y., Tomokuni, J., Sahara, A., Takabatake, H., Matsueda, K., & Yamamoto, H. (2015) · Radiology · doi:10.1148/radiol.2015150690 · Cited by 160
Shear wave elastography in chronic kidney disease: a pilot experience in native kidneys
Samir, A. E., Allegretti, A. S., Zhu, Q., Dhyani, M., Anvari, A., Sullivan, D. A., Trottier, C. A., Dougherty, S., Williams, W. W., Babitt, J. L., et al. (2015) · BMC Nephrology · doi:10.1186/s12882-015-0120-7 · Cited by 142
Self-citationZheng, J., Guo, H., Zeng, J., Huang, Z., Zheng, B., Ren, J., Xu, E., Li, K., & Zheng, R. (2015) · Radiology · doi:10.1148/radiol.14140828 · Cited by 136
Samir, A. E., Dhyani, M., Anvari, A., Prescott, J. D., Halpern, E. F., Faquin, W. C., & Stephen, A. E. (2015) · Radiology · doi:10.1148/radiol.2015141627 · Cited by 128
Self-citationJSUM ultrasound elastography practice guidelines: basics and terminology
Shiina, T. (2013) · Journal of Medical Ultrasonics · doi:10.1007/s10396-013-0490-z · Cited by 124
Böehm, K., Salomon, G., Beyer, B., Schiffmann, J., Simonis, K., Graefen, M., & Budäus, L. (2014) · The Journal of Urology · doi:10.1016/j.juro.2014.09.100 · Cited by 124
Gong, X., Xu, Q., Xu, Z., Xiong, P., Yan, W., & Chen, Y. (2011) · Breast Cancer Research and Treatment · doi:10.1007/s10549-011-1745-2 · Cited by 121
Brock, M., von Bodman, C., Palisaar, R. J., Löppenberg, B., Sommerer, F., Deix, T., Noldus, J., & Eggert, T. (2012) · The Journal of Urology · doi:10.1016/j.juro.2012.01.063 · Cited by 116
Performance of Elastography for the Evaluation of Thyroid Nodules: A Prospective Study
Azizi, G., Keller, J., Lewis, M., Puett, D., Rivenbark, K., & Malchoff, C. D. (2012) · Thyroid · doi:10.1089/thy.2012.0227 · Cited by 114
Evaluation of shearwave elastography for the characterisation of focal liver lesions on ultrasound
Guibal, A., Boularan, C., Bruce, M. F., Vallin, M., Pilleul, F., Walter, T., Scoazec, J., Boublay, N., Dumortier, J., & Lefort, T. (2012) · European Radiology · doi:10.1007/s00330-012-2692-y · Cited by 113
Wong, V. W., & Chan, H. L. (2010) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.2010.06437.x · Cited by 111
Rouvière, O., Melodelima, C., Dinh, A. H., Bratan, F., Pagnoux, G., Sanzalone, T., Crouzet, S., Colombel, M. C., Mège‐Lechevallier, F., & Souchon, R. (2016) · European Radiology · doi:10.1007/s00330-016-4534-9 · Cited by 111
Real-Time Ultrasound Elasticity of the Breast: Initial Clinical Results
Barr, R. G. (2010) · Ultrasound Quarterly · doi:10.1097/ruq.0b013e3181dc7ce4 · Cited by 109
Spatial variations in Achilles tendon shear wave speed
DeWall, R. J., Slane, L. C., Lee, K. S., & Thelen, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.008 · Cited by 105
Shear Wave Elastography for Detection of Prostate Cancer: A Preliminary Study
Woo, S., Kim, S. Y., Cho, J. Y., & Kim, S. H. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.3.346 · Cited by 103
Liu, B., Zheng, Y., Huang, G., Lin, M., Shan, Q., Lu, Y., Tian, W., & Xie, X. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.10.024 · Cited by 99
Woo, S., Suh, C. H., Kim, S. Y., Cho, J. Y., & Kim, S. H. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.17.18056 · Cited by 94
Popescu, A., Bota, S. I., Sporea, I., Șirli, R., Danilă, M., Racean, S., Suseanu, D., Grădinaru, O., & Ivașcu, S. C. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.11.013 · Cited by 88
Woo, H., Lee, J. Y., Yoon, J. H., Kim, W. K., Cho, B., & Choi, B. I. (2015) · Radiology · doi:10.1148/radiol.2015141975 · Cited by 82
Stevenson, M., Lloyd-Jones, M., Morgan, M. Y., & Wong, R. (2012) · Health Technology Assessment · doi:10.3310/hta16040 · Cited by 82
Liu, B., Liang, J., Zheng, Y., Xie, X., Huang, G., Zhou, L., Wang, W., & Lu, M. (2014) · European Radiology · doi:10.1007/s00330-014-3455-8 · Cited by 82
Pavlov, C. S., Casazza, G., Nikolova, D., Tsochatzis, E. A., & Gluud, C. N. (2016) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.13524 · Cited by 69
Accuracy of shear wave elastography for the diagnosis of prostate cancer: A meta-analysis
Sang, L., Wang, X., Xu, D., & Cai, Y. (2017) · Scientific Reports · doi:10.1038/s41598-017-02187-0 · Cited by 69
Grgurević, I., Bokun, T., Mustapić, S., Trkulja, V., Heinzl, R., Banić, M., Puljiz, Ž., Lukšić, B., & Kujundžić, M. (2015) · Croatian Medical Journal · doi:10.3325/cmj.2015.56.470 · Cited by 65
Hassan, K., Loberant, N., Abbas, N., Hassan, F., Shadia, H., & Khazim, K. (2016) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s118465 · Cited by 63
Li, G., Li, D., Fang, Y., Song, Y., Deng, Z., Gao, J. X., Xie, Y., Yin, T.-S., Li, Y., & Tang, K. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076322 · Cited by 62
Kim, S. Y., Cho, J. H., Kim, Y. J., Kim, Y. J., Kim, E. J., Park, J. Y., Jeon, T. J., Kim, Y. S., & Kim, Y. S. (2016) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.13649 · Cited by 49
Shear wave elastography assessment in the prostate: an intraobserver reproducibility study
Woo, S., Kim, S. Y., Lee, M. S., Cho, J. Y., & Kim, S. H. (2014) · Clinical Imaging · doi:10.1016/j.clinimag.2014.11.013 · Cited by 44
Acoustic radiation force impulse imaging for assessing liver fibrosis in alcoholic liver disease
Kiani, A., Brun, V., Lainé, F., Turlin, B., Morçet, J., Michalak, S., Gruyer, A. L., Legros, L., Bardou‐Jacquet, E., Gandon, Y., et al. (2016) · World Journal of Gastroenterology · doi:10.3748/wjg.v22.i20.4926 · Cited by 41
Point shear-wave elastography in chronic pancreatitis: A promising tool for staging disease severity
Pozzi, R., Parzanese, I., Baccarin, A., Giunta, M., Conti, C. B., Cantù, P., Casazza, G., Tenca, A., Rosa, R., Gridavilla, D., et al. (2017) · Pancreatology · doi:10.1016/j.pan.2017.10.003 · Cited by 41
Tachi, Y., Hirai, T., Kojima, Y., Miyata, A., Ohara, K., Ishizu, Y., Honda, T., Kuzuya, T., Hayashi, K., Ishigami, M., et al. (2016) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.13695 · Cited by 40
Balakrishnan, M., Souza, F. F., Muñoz, C., Augustín, S., Loo, N., Deng, Y., Ciarleglio, M. M., & García–Tsao, G. (2016) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.15.10056 · Cited by 39
Value of Virtual Touch Tissue Quantification in Stages of Diabetic Kidney Disease
Yu, N., Zhang, Y., & Xu, Y. H. (2014) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.33.5.787 · Cited by 38
Li, D., Guo, L., Xu, H., Liu, C., Xu, J., Sun, L., Wu, J., Liu, B.-J., Liu, L., & Xu, X. (2015) · PubMed · Cited by 23
Applications of acoustic radiation force impulse quantification in chronic kidney disease: a review
Wang, L. (2016) · ULTRASONOGRAPHY · doi:10.14366/usg.16026 · Cited by 23
Accuracy of transient elastography in the assessment of chronic hepatitis C-related liver cirrhosis
Ying, H.-Y., Lu, L., Jing, D.-D., & Ni, X. (2016) · Clinical and investigative medicine · doi:10.25011/cim.v39i5.27147 · Cited by 11
Cited by
Liver fibrosis assessment: MR and US elastography
Ozturk, A., Olson, M. C., Samir, A. E., & Venkatesh, S. K. (2021) · Abdominal Radiology · doi:10.1007/s00261-021-03269-4 · Cited by 168
Self-citationNon-invasive diagnosis and staging of non-alcoholic fatty liver disease
Kechagias, S., Ekstedt, M., Simonsson, C., & Nasr, P. (2022) · Hormones · doi:10.1007/s42000-022-00377-8 · Cited by 39
Metadata
- Authors
- Ozturk, A., Grajo, J. R., Dhyani, M., Anthony, B. W., & Samir, A. E.
- Venue
- Abdominal Radiology
- Published
- 2018-02-27
- Volume
- 43
- Issue
- 4
- Pages
- 773-785
- ISSN
- 2366-004X (ISSN-L)
- 2366-0058
- OpenAlex
- W2792320640
- Cited by
- 299
- References
- 64
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.