The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The optimised CO-rebreathing method: a new tool to determine total haemoglobin mass routinely
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, these effects are transient, with CO typically cleared from the system within 12 h (Schmidt and Prommer, 2005).”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Schmidt and Prommer, 2005
In the citing paper
“Acute low-dose CO administration has been shown to reduce oxygen-carrying capacity and decrease maximal oxygen uptake (VO2max) as CO occupies O2 binding sites on Hb and prevents Hb from fulfilling its role in oxygen transport (Schmidt and Prommer, 2005; Klausen et al., 1983).”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Schmidt and Prommer, 2005
In the citing paper
“In research and clinical practice, low-dose CO is utilized as a tracer to assess lung diffusion capacity and total hemoglobin mass (tHb-mass) (Schmidt and Prommer, 2005; Siebenmann et al., 2017; Zavorsky and Smoliga, 2017; Amann, 2012; Robach et al., 2012; Nummela et al., 2021; Saunders et al., 2013).”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Schmidt and Prommer, 2005
In the citing paper
“For application in elite endurance athletes, it should also be mentioned that the absolute training intensity, especially in high-intensity sessions, might be impaired by increased COHb concentrations (due to reductions in VO2max and time to exhaustion (Schmidt and Prommer, 2005; Ekblom and Huot, 1972; Hogan et al., 1990; Richardson et al., 2002) and increased heart rate, lactate concentration and”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Schmidt and Prommer, 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Lee, R. C., Wang, Z., Heo, M., Ross, R., Janssen, I., & Heymsfield, S. B. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/72.3.796 · Cited by 854
Metabolism of the hemin chromoproteins
Drabkin, D. L. (1951) · Physiological Reviews · doi:10.1152/physrev.1951.31.4.345 · Cited by 132
Friedmann, B., Jost, J., Rating, T., Weller, E., Werle, E., Eckardt, K.-U., Bärtsch, P., & Mairbäurl, H. (1999) · International Journal of Sports Medicine · doi:10.1055/s-2007-971097 · Cited by 79
Acute effects of cigarette smoking and inhalation of carbon monoxide during maximal exercise
Klausen, K., Andersen, C., & Nandrup, S. (1983) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00429074 · Cited by 67
Research works printed but not linked: 37
- Arnold HR, Carrier EB, Smith HP, Whipple GH (1921) Blood volume studies. Am J Physiol 56:313–327 · DOI
- Ashenden MJ, Gore CJ, Dobson GP, Hahn AG (1999) Live high, train low does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. Eur J Appl Physiol 80:479–484 · DOI
- Barker SJ (1998) Blood volume measurement. Anesthesiology 89:1310–1312 · DOI
- Barnett K, Wilson JF (1998) Quantitation of carboxyhaemoglobin in blood: external quality assessment of techniques. Br J Biomed Sci 55:123–126
- Böning D, Rojas J, Serrato M, Ulloa C, Coy L, Mora M, Hütler M (2001) Haemoglobin mass and peak oxygen uptake in untrained and trained residents of moderate altitude. Int J Sports Med 22:1–7 · DOI
- Bruce EN, Bruce MC (2003) A multicompartment model of carboxyhaemoglobin and carboxymyoglobin responses to inhalation of carbon monoxide. J Appl Physiol 95:1235–1247 · DOI
- Burge CM, Skinner SL (1995) Determination of haemoglobin mass and blood volume with CO: evaluation and application of a method. J Appl Physiol 79:623–631 · DOI · Paper page
- Douglas CG, Haldane JS, Haldane JBS (1912) The laws of combination of haemoglobin with carbon monoxide and oxygen. J Physiol 44:275–304 · DOI
- Ekblom B, Huot R (1972) Response to submaximal and maximal exercise at different levels of carboxyhaemoglobin. Acta Physiol Scand 86:474–482 · DOI · Paper page
- Fogh-Andersen N, Thomsen JK, Foldager N, Siggaard-Andersen O (1990) pH effect on the COHb absorption spectrum: importance for calibration of the OSM3 and measurement of circulating haemoglobin and blood volume. Scand J Clin Lab Invest 50:247–252 · DOI
- Gibson JG, Evans WA Jr (1937) Clinical studies of the blood volume. I. Clinical application of a method employing the azo dye “Evans Blue” and the spectrophotometer. J Clin Invest 16:301–316 · DOI · Paper page
- Godin G, Shephard RJ (1972) On the course of carbon monoxide uptake and release. Respiration 29:317–329 · DOI
- Gore CJ, Hahn AG, Burge CM, Telford RD (1997) VO2max and haemoglobin mass of trained athletes during high intensity training. Int J Sports Med 18:477–482 · DOI
- Gorelov V (2004) Theoretical value of Hüfner’s count. Anesthesia 59:97 · DOI
- Hauck H (1989) Parameters influencing carbon monoxide kinetics. Exp Pathol 37:170–176 · DOI
- He Y-L, Tanigami H, Ueyama H, Mashimo T, Yoshiya I (1998) Measurment of blood volume using indocyanine green measured with pulse-spectrophotometry: its reproducibility and reliability. Crit Care Med 26:1446–1451 · DOI
- Heinicke K, Wolfahrt B, Winchenbach P, Biermann B, Schmid A, Huber G, Friedmann B, Schmidt W (2001) Blood volume and haemoglobin mass in elite athletes of different disciplines. Int J Sports Med 22:504–512 · DOI
- Hirsch GL, Sue DY, Wasserman K, Robinson TE, Hansen JE (1985) Immediate effects of cigarette smoking on cardiorespiratory responses to exercise. J Appl Physiol 58:1975–1981 · DOI · Paper page
- Hogan MC, Bebout DE, Gray AT, Wagner PD, West JB, Haab PE (1990) Muscle maximal O2 uptake at constant O2 delivery with and without CO in the blood. J Appl Physiol 69:830–836 · DOI · Paper page
- Horvath SM, Raven PB, Dahms TE, Gray DJ (1975) Maximal aerobic capacity at different levels of caboxyhaemoglobin. J Appl Physiol 38:300–303 · DOI · Paper page
- Hütler M, Beneke R, Böning D (2000) Determination of circulating haemoglobin mass and related quantities by using capillary blood. Med Sci Sports Exerc 32:1024–1027 · DOI
- Joels N, Pugh LGCE (1958) The carbon monoxide dissociation curve of human blood. J Physiol 142:63–77 · DOI
- Kisch H, Leucht S, Lichtwarck-Schoff M, Pfeiffer UJ (1995) Accuracy and reproducibility of the measurement of actively circulating blood volume with an integrated fiberoptic monitoring system. Crit Care Med 23:885–893 · DOI
- Möller P, Sylvén C (1981) Myoglobin in human skeletal muscle. Scand J Clin Lab Invest 41:479–482 · DOI
- Mollison PL (1967) Blood volume. In: Mollison PL (ed) Blood transfusion in clinical medicine. Blackwell, Oxford, pp 115–150
- Peterson JE, Stewart RD (1970) Absorption and elimination of carbon monoxide by inactive young men. Arch Environ Health 21:165–171 · DOI
- Pirnay F, Dujardin J, Deroann R, Petit JM (1971) Muscular exercise during intoxication by carbon monoxide. J Appl Physiol 31:573–575 · DOI
- Remington JW, Baker CH (1961) Evaluation of blood volume measurment techniques. Circ Res 9:60–68 · DOI
- Richardson RS, Noyszewski EA, Saltin B, Gonzáles-Alonso J (2002) Effect of mild carboxy-haemoglobin on exercising skeletal muscle: intravascular and intracellular evidence. Am J Physiol Regul Integr Comp Physiol 283:1131–1139 · DOI · Paper page
- Sawka MN, Convertino VA, Eichner ER, Schnieder SM, Young AJ (2000) Blood volume: importance and adaptions to exercise training, environmental stresses, and trauma /sickness. Med Sci Sports Exerc 32:332–348 · DOI
- Shimazu T, Ikeuchi H, Sugomoto H, Goodwin CW, Mason AD, Pruitt BA (2000) Half-life of blood carboxyhaemoglobin after short-term and long-term exposure to carbon monoxide. J Trauma Inj Infect Crit Care 49:126–131 · DOI
- Thomsen JK, Fogh-Andersen N, Bülow K, Devantier A (1991) Blood and plasma volumes determined by carbon monoxide gas, 99mTc-labelled erythrocytes, 125 I-albumin and the T 1824 technique. Scand J Clin Lab Invest 51:185–190 · DOI
- Tikuisis P, Buick F, Kane DM (1987) Percent carboxyhaemoglobin in resting humans exposed repeatedly to 1,500 and 7,500 ppm CO. J Appl Physiol 63:820–827 · DOI
- Togores B, Bosch M, Agustí AGN (2000) The measurement of exhaled carbon monoxide is influenced by airflow obstruction. Eur Respir J 15:177–180 · DOI
- Tschaikowsky K, Meisner M, Durst R, Rügheimer E (1997) Blood volume determination using hydroxyethyl starch: a rapid and a simple intravenous injection method. Crit Care Med 25:599–606 · DOI
- Vogel JA, Gleser MA (1972) Effect of carbon monoxide on oxygen transport during exercise. J Appl Phys 32:234–239
- Weaver LK, Howe S, Hopkins R, Chan KJ (2001) Carboxyhaemoglobin half-life in carbon monoxide-poisoned patients treated with 100% oxygen at atmospheric pressure. Chest 117:801–808 · DOI · Paper page
Cited by
Mountjoy, M., Ackerman, K. E., Bailey, D. M., Burke, L. M., Constantini, N., Hackney, A. C., Heikura, I. A., Melin, A., Pensgaard, A. M., Stellingwerff, T., et al. (2023) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-106994 · Cited by 974
Red blood cells in sports: Effects of exercise and training on oxygen supply by red blood cells
Mairbäurl, H. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00332 · Cited by 482
Iron considerations for the athlete: a narrative review
Sim, M., Garvican-Lewis, L. A., Cox, G. R., Govus, A., McKay, A. K. A., Stellingwerff, T., & Peeling, P. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04157-y · Cited by 274
Otto, J. M., Plumb, J. O. M., Clissold, E., Kumar, S. B., Wakeham, D. J., Schmidt, W., Grocott, M. P. W., Richards, T., & Montgomery, H. E. (2017) · Haematologica · doi:10.3324/haematol.2017.169680 · Cited by 93
Self-citationIntravenous iron supplementation in distance runners with low or suboptimal ferritin
GARVICAN, L. A., SAUNDERS, P. U., CARDOSO, T., MACDOUGALL, I. C., LOBIGS, L. M., FAZAKERLEY, R., FALLON, K. E., ANDERSON, B., ANSON, J. M., THOMPSON, K. G., et al. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182a53594 · Cited by 91
Govus, A. D., Garvican-Lewis, L. A., Abbiss, C. R., Peeling, P., & Gore, C. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135120 · Cited by 91
Haemoglobin concentration and mass as determinants of exercise performance and of surgical outcome
Otto, J. M., Montgomery, H. E., & Richards, T. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-33 · Cited by 74
Saunders, P. U., Ahlgrim, C., Vallance, B., Green, D. J., Robertson, E. Y., Clark, S. A., Schumacher, Y. O., & Gore, C. J. (2010) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.5.4.521 · Cited by 37
Best, S. A., Okada, Y., Galbreath, M. M., Jarvis, S. S., Bivens, T. B., Adams‐Huet, B., & Fu, Q. (2014) · Experimental Physiology · doi:10.1113/expphysiol.2013.077248 · Cited by 31
Rissanen, A.-P. E., Tikkanen, H. O., Koponen, A. S., Aho, J. M., Hägglund, H., Lindholm, H., & Peltonen, J. E. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00265 · Cited by 25
Wang, J., Ji, Y., Zhou, L., Xiang, Y., Heinonen, I., & Zhang, P. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00701 · Cited by 22
Dias, K. A., Lawley, J. S., Gatterer, H., Howden, E. J., Sarma, S., Cornwell, W. K., Hearon, C. M., Samels, M., Everding, B., Liang, A. S.-W., et al. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00289.2019 · Cited by 16
Gatterer, H., Dünnwald, T., Woyke, S., Faulhaber, M., Schumacher, Y. O., & Schobersberger, W. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1490205 · Cited by 13
Villanova, S., Porcelli, S., Ekström, L., & Cardinale, D. A. (2026) · Experimental Physiology · doi:10.1113/ep093005 · Cited by 5
Metadata
- Authors
- Schmidt, W., & Prommer, N.
- Venue
- European Journal of Applied Physiology
- Published
- 2005-10-13
- Volume
- 95
- Issue
- 5-6
- Pages
- 486-495
- ISSN
- 1439-6319
- 1439-6327
- Cited by
- 335
- References
- 6
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.