A review on impedimetric immunosensors for pathogen and biomarker detection
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
Since the discovery of antibiotics in the first quarter of the twentieth century, their use has been the principal approach to treat bacterial infection. Modernized medicine such as cancer therapy, organ transplantation or advanced major surgeries require effective antibiotics to manage bacterial infections. However, the irresponsible use of antibiotics along with the lack of development has led to the emergence of antimicrobial resistance which is considered a serious global threat due to the rise of multidrug-resistant bacteria (Wang et al. in Antibiotic resistance: a rundown of a global crisis, pp. 1645–1658, 2018). Currently employed diagnostics techniques are microscopy, colony counting, ELISA, PCR, RT-PCR, surface-enhanced Raman scattering and others. These techniques provide satisfactory selectivity and sensitivity (Joung et al. in Sens Actuators B Chem 161:824–831, 2012). Nevertheless, they demand specialized personnel and expensive and sophisticated machinery which can be labour-intensive and time-consuming, (Malvano et al. in Sensors (Switzerland) 18:1–11, 2018; Mantzila et al. in Anal Chem 80:1169–1175, 2008). To get around these problems, new technologies such as biosensing and lab-on-a-chip devices have emerged in the last two decades. Impedimetric immunosensors function by applying electrochemical impedance spectroscopy to a biosensor platform using antibodies or other affinity proteins such as Affimers (Tiede et al. in Elife 6(c):1–35, 2017) or other binding proteins (Weiss et al. in Electrochim Acta 50:4248–4256, 2005) as bioreceptors, which provide excellent sensitivity and selectivity. Pre-enrichment steps are not required and this allows miniaturization and low-cost. In this review different types of impedimetric immunosensors are reported according to the type of electrode and their base layer materials, either self-assembled monolayers or polymeric layers, composition and functionalization for different types of bacteria, viruses, fungi and disease biomarkers. Additionally, novel protein scaffolds, both antibody derived and non-antibody derived, used to specifically target the analyte are considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
Advances in the science and technology of carbon nanotubes and their composites: a review
Thostenson, E. T., Ren, Z., & Chou, T.-W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(01)00094-x · Cited by 5,005
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Antibiotic resistance: a rundown of a global crisis
Aslam, B., Wang, W., Arshad, M. I., Khurshid, M., Muzammil, S., Rasool, M. H., Nisar, M. A., Alvi, R. F., Aslam, M. A., Qamar, M. U., et al. (2018) · Infection and Drug Resistance · doi:10.2147/idr.s173867 · Cited by 2,552
RajanBabu, T. V. (. (2001) · Encyclopedia of Reagents for Organic Synthesis · doi:10.1002/047084289x.re001 · Cited by 2,480
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Lectins: Carbohydrate-Specific Proteins That Mediate Cellular Recognition
Lis, H., & Sharon, N. (1998) · Chemical Reviews · doi:10.1021/cr940413g · Cited by 1,760
Recent Advances in Understanding Enteric Pathogenic Escherichia coli
Croxen, M. A., Law, R. J., Scholz, R., Keeney, K. M., Wlodarska, M., & Finlay, B. B. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00022-13 · Cited by 1,569
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Genetic Analysis of Human Norovirus Strains in Japan in 2016–2017
Nagasawa, K., Matsushima, Y., Motoya, T., Mizukoshi, F., Ueki, Y., Sakon, N., Murakami, K., Shimizu, T., Okabe, N., Nagata, N., et al. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.00001 · Cited by 1,257
Borisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Electrochemical impedance spectroscopy: an overview of bioanalytical applications
Randviir, E. P., & Banks, C. E. (2013) · Analytical Methods · doi:10.1039/c3ay26476a · Cited by 795
Chaubey, A., & Malhotra, B. D. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00313-x · Cited by 777
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Sakamoto, S., Putalun, W., Vimolmangkang, S., Phoolcharoen, W., Shoyama, Y., Tanaka, H., & Morimoto, S. (2018) · Journal of Natural Medicines · doi:10.1007/s11418-017-1144-z · Cited by 602
Petryayeva, E., Algar, W. R., & Medintz, I. L. (2013) · Applied Spectroscopy · doi:10.1366/12-06948 · Cited by 590
Impedance Spectroscopy: Applications to Electrochemical and Dielectric Phenomena
Lvovich, V. F. (2012) · Wiley eBooks · doi:10.1002/9781118164075 · Cited by 498
Impedance Spectroscopy: Applications to Electrochemical and Dielectric Phenomena
Lvovich, V. F. (2012) · Cited by 479
A review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Nanobodies as therapeutics: big opportunities for small antibodies
Steeland, S., Vandenbroucke, R. E., & Libert, C. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.04.003 · Cited by 468
Huang, C.-C., & Chang, H.-T. (2006) · Analytical Chemistry · doi:10.1021/ac061487i · Cited by 462
Guan, J.-G., Miao, Y.-Q., & Zhang, Q.-J. (2004) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(04)70195-4 · Cited by 368
Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells
Varshney, M., & Li, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.001 · Cited by 360
Salmonella enterica Serovar Typhi and the Pathogenesis of Typhoid Fever
Dougan, G., & Baker, S. (2014) · Annual Review of Microbiology · doi:10.1146/annurev-micro-091313-103739 · Cited by 338
Generation of mutation hotspots in ageing bacterial colonies
Sekowska, A., Wendel, S., Fischer, E. C., Nørholm, M. H. H., & Danchin, A. (2016) · Scientific Reports · doi:10.1038/s41598-016-0005-4 · Cited by 320
Antibody production, design and use for biosensor-based applications
Conroy, P. J., Hearty, S., Leonard, P., & O’Kennedy, R. J. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.01.010 · Cited by 314
A review on impedimetric biosensors
Bahadır, E. B., & Sezgintürk, M. K. (2016) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.3109/21691401.2014.942456 · Cited by 307
Diagnostic biosensors in medicine – A review
Metkar, S. K., & Girigoswami, K. (2019) · Biocatalysis and Agricultural Biotechnology · doi:10.1016/j.bcab.2018.11.029 · Cited by 304
Listeria monocytogenes: epidemiology, human disease, and mechanisms of brain invasion
Drevets, D. A., & Bronze, M. S. (2008) · FEMS Immunology & Medical Microbiology · doi:10.1111/j.1574-695x.2008.00404.x · Cited by 303
Liu, S. H., & Han, M. Y. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400427 · Cited by 282
Active surveillance for early‐stage prostate cancer: Review of the current literature
Dall'Era, M. A., Cooperberg, M. R., Chan, J. M., Davies, B. J., Albertsen, P. C., Klotz, L. H., Warlick, C. A., Holmberg, L., Bailey, D. E., Wallace, M. E., et al. (2008) · Cancer · doi:10.1002/cncr.23373 · Cited by 273
Biosensors - classification, characterization and new trends
Monošík, R., Streďanský, M., & Šturdík, E. (2012) · Acta Chimica Slovaca · doi:10.2478/v10188-012-0017-z · Cited by 269
Methodological approaches for studying the microbial ecology of drinking water distribution systems
Douterelo, I., Boxall, J. B., Deines, P., Sekar, R., Fish, K. E., & Biggs, C. A. (2014) · Water Research · doi:10.1016/j.watres.2014.07.008 · Cited by 260
Chen, K., Lu, G., Chang, J., Mao, S., Yu, K., Cui, S., & Chen, J. (2012) · Analytical Chemistry · doi:10.1021/ac3000336 · Cited by 253
Jiang, Y., Deng, S., Lei, J., Ju, H., & Gunasekaran, S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.08.011 · Cited by 220
Kokkinos, C., Economou, A., & Prodromidis, M. I. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.020 · Cited by 214
Affimer proteins are versatile and renewable affinity reagents
Tiede, C., Bedford, R., Heseltine, S. J., Smith, G., Wijetunga, I., Ross, R., AlQallaf, D., Roberts, A. P., Balls, A., Curd, A., et al. (2017) · eLife · doi:10.7554/elife.24903 · Cited by 203 · cited 3×
“As a consequence, new antibody derived proteins such as nanobodies or non-antibody proteins such as Affimers are being investigated in this field.”
BackgroundRushworth, J. V., Ahmed, A., Griffiths, H. H., Pollock, N. M., Hooper, N. M., & Millner, P. A. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.12.036 · Cited by 195
Self-citationOblath, E. A., Henley, W. H., Alarie, J. P., & Ramsey, J. M. (2013) · Lab on a Chip · doi:10.1039/c3lc40961a · Cited by 173 · cited 1×
“Pathogens found in different bio-fluids such as saliva, urine and blood can be detected [15, 16].”
BackgroundBiocompatibility of nanoporous alumina membranes for immunoisolation
La Flamme, K. E., Popat, K. C., Leoni, L., Markiewicz, E., La Tempa, T. J., Roman, B. B., Grimes, C. A., & Desai, T. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.010 · Cited by 170
Adhiron: a stable and versatile peptide display scaffold for molecular recognition applications
Tiede, C., Tang, A. A. S., Deacon, S. E., Mandal, U., Nettleship, J. E., Owen, R. L., George, S. E., Harrison, D. J., Owens, R. J., Tomlinson, D. C., et al. (2014) · Protein Engineering, Design and Selection · doi:10.1093/protein/gzu007 · Cited by 163
Ahar, M. J., Rashidi, M., Barar, J., Aghaie, M., Mohammadnejad, D., Ramazani, A., Karami, P., Coukos, G., & Omidi, Y. (2015) · Nanoscale · doi:10.1039/c4nr06687a · Cited by 156
Joung, C.-K., Kim, H.-N., Lim, M., Jeon, T., Kim, H., & Kim, Y. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.01.024 · Cited by 149
Wang, R., Ruan, C., Kanayeva, D. A., Lassiter, K., & Li, Y. (2008) · Nano Letters · doi:10.1021/nl080366q · Cited by 146
Detection of Foodborne Pathogens by Surface Enhanced Raman Spectroscopy
Zhao, X., Li, M., & Xu, Z. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.01236 · Cited by 138 · cited 1×
“Finally, the SERS technique requires expensive and sophisticated laser equipment [12].”
MethodDevelopment of an impedimetric aflatoxin M1 biosensor based on a DNA probe and gold nanoparticles
Dinçkaya, E., Kınık, Ö., Sezgintürk, M. K., Altuğ, Ç., & Akkoca, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.02.038 · Cited by 127
Ciani, I., Schulze, H., Corrigan, D. K., Henihan, G., Giraud, G., Terry, J. G., Walton, A. J., Pethig, R., Ghazal, P., Crain, J. N., et al. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.004 · Cited by 124
Transcription factor TFCP2L1 patterns cells in the mouse kidney collecting ducts
Werth, M., Schmidt-Ott, K. M., Leete, T., Qiu, A., Hinze, C., Viltard, M., Paragas, N., Shawber, C. J., Yu, W., Lee, P., et al. (2017) · eLife · doi:10.7554/elife.24265 · Cited by 122
Elshafey, R., Tlili, C., Abulrob, A., Tavares, A. C., & Zourob, M. M. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.049 · Cited by 98 · cited 1×
“3 pg/mL respectively, both in less than 1 h, and thus improving the detection time of commercial kits which last for 5 h [105].”
BackgroundLi, Z., Fu, Y., Fang, W., & Li, Y. (2015) · Sensors · doi:10.3390/s150819212 · Cited by 95
Ahmed, A., Rushworth, J. V., Wright, J. D., & Millner, P. A. (2013) · Analytical Chemistry · doi:10.1021/ac403253j · Cited by 89
Self-citationKanayeva, D. A., Wang, R., Rhoads, D. D., Erf, G. F., Slavik, M. F., Tung, S. C. H., & Li, Y. (2012) · Journal of Food Protection · doi:10.4315/0362-028x.jfp-11-516 · Cited by 75
Wang, R., Dong, W., Ruan, C., Kanayeva, D. A., Lassiter, K., Tian, R., & Li, Y. (2009) · Nano Letters · doi:10.1021/nl902819e · Cited by 75
Zhurauski, P., Arya, S. K., Jolly, P., Tiede, C., Tomlinson, D. C., Ferrigno, P. K., & Estrela, P. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.041 · Cited by 74
Wang, R., Lum, J., Callaway, Z. T., Lin, J., Bottje, W. G., & Li, Y. (2015) · Biosensors · doi:10.3390/bios5040791 · Cited by 74
A regenerating ultrasensitive electrochemical impedance immunosensor for the detection of adenovirus
Lin, D., Tang, T., Harrison, D. J., Lee, W. E., & Jemere, A. B. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.12.032 · Cited by 62 · cited 1×
“Other impedimetric immunosensors include a regenerable biosensor for adenovirus type 5 (Ad5) detection [87], a biosensor for plum pox virus (PPV) [88] which affects plants from genus Prunus and a biosensor platform for the pathogen oomycete fungus Aphanomyces invadans [89], known to cause epizootic ulcerative syndrome…”
BackgroundLennon, R. P., Claussen, K. A., & Kuersteiner, K. A. (2018) · Primary Care Clinics in Office Practice · doi:10.1016/j.pop.2017.11.001 · Cited by 54 · cited 6×
“Cardiovascular diseases (CVD) is a major cause of death worldwide, estimated to be up to 30%.”
BackgroundInfluentialChowdhury, A. D., Ganganboina, A. B., Park, E. Y., & Doong, R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.039 · Cited by 51
Impedimetric immunosensor for detection of cardiovascular disorder risk biomarker
Khan, R., Pal, M., Kuzikov, A. V., Bulko, T. V., Suprun, E. V., & Shumyantseva, V. V. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.05.107 · Cited by 50 · cited 1×
“However, the most sensitive impedimetric immunosensor for Mb was achieved by [93], in which Screen-printed multi-walled carbon nanotubes electrodes (MWCNTs) [94] could improve the sensitivity of Mb detection.”
MethodLi, G., Zhu, M., Ma, L., Yan, J., Lü, X., Shen, Y., & Wan, Y. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b04658 · Cited by 47
A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker
Asav, E., & Sezgintürk, M. K. (2014) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2014.02.032 · Cited by 46
Lima, D., Inaba, J., Lopes, L. C., Calaça, G. N., Weinert, P. L., Fogaça, R. L., de Moura, J. F., Alvarenga, L. M., de Figueiredo, B. C., Wohnrath, K., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.02.063 · Cited by 41
Joung, C.-K., Kim, H.-N., Im, H.-C., Kim, H., Oh, M., & Kim, Y. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.041 · Cited by 41
The development and optimisation of nanobody based electrochemical immunosensors for IgG
Goode, J. A., Dillon, G., & Millner, P. A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.132 · Cited by 34
Self-citationHirst, N. A., Hazelwood, L. D., Jayne, D. G., & Millner, P. A. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.06.090 · Cited by 32
Self-citationTothill, I. E., Newman, J. D., White, S. F., & Turner, A. P. F. (1997) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(96)00200-1 · Cited by 31
Cardosi, M. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)85043-a · Cited by 5
Cited by
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Magar, H. S., Hassan, R. Y. A., & Mulchandani, A. (2021) · Sensors · doi:10.3390/s21196578 · Cited by 1,335
Impedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Li, S., Zhang, H., Zhu, M., Kuang, Z., Li, X., Xu, F., Miao, S., Zhang, Z., Lou, X., Li, H., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00759 · Cited by 309
Conventional and advanced detection techniques of foodborne pathogens: A comprehensive review
Kabiraz, M. P., Majumdar, P. R., Mahmud, M. M. C., Bhowmik, S., & Ali, A. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e15482 · Cited by 218
Current and Future Technologies for the Detection of Antibiotic-Resistant Bacteria
Yamin, D., Uskoković, V., Wakil, A., Goni, M., Shamsuddin, S., Mustafa, F., Alfouzan, W., Alissa, M., Alshengeti, A., Almaghrabi, R., et al. (2023) · Diagnostics · doi:10.3390/diagnostics13203246 · Cited by 214
“For AST tests, electrochemical sensors have been suggested to be of great application [203,236,237].”
Background
Metadata
- Authors
- Leva-Bueno, J., Peyman, S. A., & Millner, P. A.
- Venue
- Medical Microbiology and Immunology
- Published
- 2020-04-03
- Volume
- 209
- Issue
- 3
- Pages
- 343-362
- ISSN
- 0044-3077 (ISSN-L)
- 0300-8584
- 1432-1831
- OpenAlex
- W3014587231
- Cited by
- 187
- References
- 70
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.