Cited by 48Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyCardiovascular Health and Disease Prevention

The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph

Shelley, Kirk H., Dickstein, Marc, Shulman, Steven M.·1993·Journal of Clinical Monitoring

Abstract

The pulse oximeter can serve as a sensitive photoelectric plethysmograph in the operating room. It was noted in several cases that the plethysmographic waveform showed a high degree of variability during diastole. Three patients are described with discrete diastolic peaks on the plethysmograph. Further investigation revealed that these diastolic peaks appear to correlate with peripheral venous pulsation, which seems to have a central venous origin. Evidence is presented that the plethysmographic detection of the venous-pulse may be useful in estimating the changing volume status of the patient.

Integrity signals

Registry

Crossref · 10.1007/bf02886699

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Shelley, K. H., Dickstein, M., & Shulman, S. M.
Affiliations
  • Pennsylvania State University (US)
  • Columbia University (US)
Venue
Journal of Clinical Monitoring
Published
1993-09
Volume
9
Issue
4
Pages
283-287
ISSN
  • 1387-1307 (ISSN-L)
  • 0748-1977
  • 1573-2614
OpenAlex
W2065036059
Cited by
48
References
11
Citations by year
2026: 1 · 2025: 1 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 3 · 2017: 1 · 2016: 4 · 2015: 4 · 2014: 2 · 2013: 1 · 2012: 2
FWCI
0.41
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Clinical Monitoring and Computing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
pulse oximeter, plethysmography, operating room monitoring, photoelectric plethysmography
MeSH terms
Adult, Aged, Female, Humans, Middle Aged, Oximetry, Plethysmography, Pulse, Veins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review