The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph
Abstract
The pulse oximeter can serve as a sensitive photoelectric plethysmograph in the operating room. It was noted in several cases that the plethysmographic waveform showed a high degree of variability during diastole. Three patients are described with discrete diastolic peaks on the plethysmograph. Further investigation revealed that these diastolic peaks appear to correlate with peripheral venous pulsation, which seems to have a central venous origin. Evidence is presented that the plethysmographic detection of the venous-pulse may be useful in estimating the changing volume status of the patient.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The venous system contributes periodicity to the PPG signal, but this is often considered noise.
“The venous system similarly contributes periodicity to the PPG signal, but this is often considered noise.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [116]
Changes to diastolic amplitude due to the presence of the venous waveform can increase diastolic phase amplitude up to 40% of the total alternating amplitude of the PPG signal.
“It appears that changes to diastolic amplitude due to the presence of the venous waveform can increase diastolic phase amplitude up to 40% of the total alternating amplitude of the PPG signal.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [116]
Diastole variability in the PPG signal is related to peripheral venous pulsation.
“Shelley et al. demonstrates diastole variability in the PPG signal is related to peripheral venous pulsation [116].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [116]
Venous pulsations have been shown to artificially inflate the systolic peak amplitude and interfere with the rising systolic edge of the typical PPG waveform.
“They have been shown to artificially inflate the systolic peak amplitude and interfere with the rising systolic edge of the typical PPG waveform; an important parameter used in cardiovascular health determination [116].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [116]
Cites
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA · doi:10.1001/jama.1991.03470200123049 · Cited by 1,287 · see citing works
Perel, A., Pizov, R., & Cotev, S. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00009 · Cited by 408 · see citing works
Standards for Patient Monitoring During Anesthesia at Harvard Medical School
Eichhorn, J. H. (1986) · JAMA · doi:10.1001/jama.1986.03380080063029 · Cited by 407 · see citing works
A Single-blind Study of Combined Pulse Oximetry and Capnography in Children
Coté, C. J., Rolf, N., Liu, L. M. P., Goudsouzian, N. G., Ryan, J. F., Zaslavsky, A. M., Gore, R., Todres, I. D., Vassallo, S. A., Polaner, D. M., et al. (1991) · Anesthesiology · doi:10.1097/00000542-199106000-00003 · Cited by 218 · see citing works
PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIA
Dorlas, J. C., & Nijboer, J. A. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.5.524 · Cited by 160 · see citing works
Blood Flow Limits and Pulse Oximeter Signal Detection
Lawson, D., Norley, I., Korbon, G., Loeb, R. G., & Ellis, J. B. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00032 · Cited by 137 · see citing works
Use of Pulse Oximetry as a Noninvasive Indicator of Intravascular Volume Status
Partridge, B. L. (1987) · The Journal of Clinical Monitoring · doi:10.1007/bf03337381 · Cited by 115 · see citing works
Pulse Oximetry: Technical Aspects of Machine Design
Pologe, J. A. (1987) · International Anesthesiology Clinics · doi:10.1097/00004311-198702530-00009 · Cited by 110 · see citing works
Central venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry
Sami, H. M., Kleinman, B. S., & Lonchyna, V. A. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01619351 · Cited by 36 · see citing works
KIM, J. M., Arakawa, K., & VonLINTEL, T. (1975) · Anesthesia & Analgesia · doi:10.1213/00000539-197505000-00005 · Cited by 28 · see citing works
Pälve, H., & Vuori, A. (1991) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(91)90154-l · Cited by 19 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289 · see citing works
Self-citationThe peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 231 · see citing works
Cannesson, M. P., Attof, Y., Rosamel, P., Desebbe, O., Joseph, P., Metton, O., Bastien, O. H., & Lehot, J.-J. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267593.72744.20 · Cited by 215 · see citing works
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194 · see citing works
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 120 · see citing works
Keller, G., Cassar, E., Desebbe, O., Lehot, J.-J., & Cannesson, M. P. (2008) · Critical Care · doi:10.1186/cc6822 · Cited by 115 · see citing works
Shelley, K. H., Tamai, D., Jablonka, D., Gesquiere, M., Stout, R. G., & Silverman, D. G. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000145063.01043.4b · Cited by 91 · see citing works
Self-citationShelley, K. H., Alian, A. A., Stout, R. G., & Silverman, D. G. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9010-7 · Cited by 86 · see citing works
Self-citationUsing ventilation-induced plethysmographic variations to optimize patient fluid status
Desebbe, O., & Cannesson, M. P. (2008) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e32831504ca · Cited by 70 · see citing works
Arterial-pulse oximetry loops: a new method of monitoring vascular tone.
Shelley, K. H., Murray, W. B., & Chang, D. (1997) · The Journal of Clinical Monitoring · doi:10.1023/a:1007361020825 · Cited by 61 · see citing works
Self-citationMeasuring venous oxygenation using the photoplethysmograph waveform
Walton, Z. D., Kyriacou, P. A., Silverman, D. G., & Shelley, K. H. (2010) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-010-9248-y · Cited by 53 · see citing works
Self-citationThe pulse in reflectance pulse oximetry: Modeling and experimental studies
Reuss, J. L., & Siker, D. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-2909-6 · Cited by 47 · see citing works
Advances in photoplethysmography: beyond arterial oxygen saturation
Bartels, K., & Thiele, R. H. (2015) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-015-0458-0 · Cited by 46 · see citing works
The effect of vascular changes on the photoplethysmographic signal at different hand elevations
Hickey, M., Phillips, J. P., & Kyriacou, P. A. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/425 · Cited by 43 · see citing works
Arterial flow waveforms from pulse oximetry compared with measured Doppler flow waveforms
Wisely, N. A., & Cook, L. B. (2001) · Anaesthesia · doi:10.1046/j.1365-2044.2001.01987.x · Cited by 38 · see citing works
Papini, G. B., Fonseca, P. M., Eerikäinen, L. M., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae7f8 · Cited by 32 · see citing works
Extracting arterial flow waveforms from pulse oximeter waveforms
Cook, L. B. (2001) · Anaesthesia · doi:10.1046/j.1365-2044.2001.01986.x · Cited by 32 · see citing works
Advances in Photoplethysmography for Personalized Cardiovascular Monitoring
Kim, S., Xiao, X., & Chen, J. (2022) · Biosensors · doi:10.3390/bios12100863 · Cited by 25 · see citing works
Pulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel
Phillips, J. P., Kyriacou, P. A., Jones, D. P., Shelley, K. H., & Langford, R. M. (2008) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e328317794d · Cited by 23 · see citing works
Self-citationPerfusion Changes at the Forehead Measured by Photoplethysmography during a Head-Down Tilt Protocol
Ysehak Abay, T., Shafqat, K., & Kyriacou, P. A. (2019) · Biosensors · doi:10.3390/bios9020071 · Cited by 22 · see citing works
Yuan, H., Memon, S. F., Newe, T., Lewis, E., & Leen, G. (2017) · Measurement · doi:10.1016/j.measurement.2017.10.060 · Cited by 22 · see citing works
Selis, J. E., & Kadakia, S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2640 · Cited by 19 · see citing works
Plethysmography: the new wave in haemodynamic monitoring – a review of clinical applications
Dennis, M. J. (2000) · Australian Critical Care · doi:10.1016/s1036-7314(00)70611-4 · Cited by 19 · see citing works
Mashhadi, M. B., Farhadi, M., Essalat, M., & Marvasti, F. (2018) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2018.8461520 · Cited by 16 · see citing works
Murray, A., Drummond, G. B., Dodds, S., & Marshall, L. (2009) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e328318c6bd · Cited by 12 · see citing works
Estimation of instantaneous venous blood saturation using the photoplethysmograph waveform
Shafqat, K., Langford, R. M., & Kyriacou, P. A. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/10/2203 · Cited by 12 · see citing works
Extracting Venous and Respiration Signals from Photoplethysmographs
Yousefi, R., & Nourani, M. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2334697 · Cited by 12 · see citing works
Alian, A. A., Shelley, K. H., & Wu, H. (2022) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-022-00866-6 · Cited by 11 · see citing works
Self-citationEstimation of Venous oxygenation saturation using the finger Photoplethysmograph (PPG) waveform
Shafqat, K., Langford, R. M., Pal, S. K., & Kyriacou, P. A. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346571 · Cited by 9 · see citing works
Physiology and clinical utility of the peripheral venous waveform
Chang, D., Leisy, P. J., Sobey, J. H., Reddy, S. K., Brophy, C. M., Alvis, B. D., Hocking, K. M., & Polcz, M. E. (2020) · JRSM Cardiovascular Disease · doi:10.1177/2048004020970038 · Cited by 9 · see citing works
Eid, A.-M., Elgamal, M. H., Fiol, A. G., Shelley, K. H., Wu, H., & Alian, A. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd165 · Cited by 8 · see citing works
Self-citationDesign of a Two-Channel Forehead PPG Sensor
Du, Y. H., Sun, C., Zhang, M., & Mai, S. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388984 · Cited by 5 · see citing works
Farhadi, M., Mashhadi, M. B., Essalat, M., & Marvasti, F. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/092627 · Cited by 5 · see citing works
Current State and Problems of Pulse Oximetry(Global Aspects on Pulse Oximeter: Part 2)
Ukawa, T. (2007) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/ikakikaigaku.77.2_52 · Cited by 3 · see citing works
Addison, P. S., Wang, R., Uribe, A. A., & Bergese, S. D. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/576340 · Cited by 2 · see citing works
Non-invasive guidance of fluid therapy
Cannesson, M. P. (2016) · Cambridge University Press eBooks · doi:10.1017/cbo9781316401972.018 · Cited by 2 · see citing works
Relief for Muscle Crampness and Detector for EMG and PPG
Ajay, R., Rajan, A., Jophy, J., & Varghese, C. (2018) · Cited by 2 · see citing works
Keogh, C., Drummond, G. B., Bates, A., Mann, J., & Arvind, D. K. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac482e · Cited by 1 · see citing works
Assessing fluid responsiveness: the role of dynamic haemodynamic indices
Ercole, A. (2007) · Trauma · doi:10.1177/1460408607082337 · Cited by 1 · see citing works
Dalmon, P., Bourrier, P., Hardouin-Willer, C., & Perroux, D. (1997) · Réanimation Urgences · doi:10.1016/s1164-6756(97)80028-x
Utilisation de l’oxymètre de pouls pour le monitorage hémodynamique fonctionnel au bloc opératoire
Cannesson, M. P., Desebbe, O., & Lehot, J. (2008) · Le Praticien en Anesthésie Réanimation · doi:10.1016/j.pratan.2008.03.002
Photoplethysmogram change by Trendelenburg position and insufflation of abdominal carbon dioxide
Bahk, J.-H., & Ahn, W. (2013) · Journal of Anesthesia · doi:10.1007/s00540-013-1637-1
Alipour, M.-R., Rastegar, M., Ghaderian, M., Namayandeh, S. M., Faraji, R., & Pezeshkpour, Z. (2016) · Iranian Journal of Pediatrics · doi:10.5812/ijp.5833
Hahn, R. G. (2016) · Cambridge University Press eBooks · doi:10.1017/cbo9781316401972.016
Pal, R., Rudas, Á., Chiang, J. N., Barney, A. M., & Cannesson, M. P. (2025) · medRxiv · doi:10.64898/2025.12.30.25343231
Joshi, M. P., Bhosale, S. J., Thanawala, I., & Kulkarni, A. P. (2026) · Journal of Anaesthesiology Clinical Pharmacology · doi:10.4103/joacp.joacp_313_25
- Authors
- Shelley, K. H., Dickstein, M., & Shulman, S. M.
- Affiliations
- Pennsylvania State University (US)
- Columbia University (US)
- Venue
- Journal of Clinical Monitoring
- Published
- 1993-09
- Volume
- 9
- Issue
- 4
- Pages
- 283-287
- ISSN
- 1387-1307 (ISSN-L)
- 0748-1977
- 1573-2614
- OpenAlex
- W2065036059
- Cited by
- 48
- References
- 11
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 3 · 2017: 1 · 2016: 4 · 2015: 4 · 2014: 2 · 2013: 1 · 2012: 2
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- pulse oximeter, plethysmography, operating room monitoring, photoelectric plethysmography
- MeSH terms
- Adult, Aged, Female, Humans, Middle Aged, Oximetry, Plethysmography, Pulse, Veins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review