Relationship Between Measurement Site and Motion Artifacts in Wearable Reflected Photoplethysmography
Abstract
Pulse rates obtained from wearable photoplethysmography (PPG) sensors are important for monitoring cardiovascular condition, especially during exercise. However, it is difficult to precisely count pulse rates during exercise because PPG is sensitive to body movement. The artifacts from body movement are caused by a change in the blood volume at the measurement site, in addition to pulsatile changes. Here, we investigated the influence of motion artifact with respect to light source and anatomical sites. In this study, we compared the signal from green-light PPG to that from infrared PPG at different anatomical sites. In these experiments, 11 subjects were asked to either assume a resting position or generate spontaneous motion artifact by jumping and swinging their arm. As a result, pulse rates obtained from green-light PPG showed a higher correlation with the ECG R-R interval as compared to those obtained with infrared. Additionally, the signal from the upper arm showed less artifact than did the peripheral one. Therefore, the green-light PPG may be useful for pulse rate monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We therefore interpret intensity-linked improvements as modest rather than decisive, but they do suggest that PPG systems may perform comparatively better when stroke volume and pulsatility increase [2,29].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [29]
In the citing paper
“and has displayed more accurate measurement of heart rate in conjunction with an accelerometer compared to an infrared heart rate system when compensating for movement artifacts (Maeda, Sekine, Tamura, 2011b).”
From Examining the Role of Implicit Emotional Judgments in Social Anxiety and Experiential Avoidance (2017) · cites this paper as Maeda, Sekine, Tamura, 2011b
In the citing paper
“Motion artifacts are a primary cause of bad signal quality, and research has suggested various methods for mitigating these26,39,40.”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [39]
In the citing paper
“Nevertheless, these artifact characteristics cannot be straightforwardly transferred to simulating the wrist PPG since distinct body locations have different tissue optical properties for different wavelengths and are prone to specific interference [54].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [54]
In the citing paper
“These alternative sites can have advantages over the wrist, such as being less prone to motion artifact [63] or vasoconstriction [62], and providing more accurate HR measurements [64].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [63]
In the citing paper
“During sedentary moments, respiration rate, thermoregulation, and sympathetic nervous system activity cause the DC baseline to wander [162].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“The green sensor also had a lower artifact ratio for all locations compared to the IR sensor.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“With their longer wavelengths, red and IR have deeper penetration depths compared to blue and green, making them prone to more motion artifacts such as the factors that directly affect the DC baseline [162,164].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“The highest correlation coefficient between the PPG signal and a chest ECG was that of the green sensor on the upper arm.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“They found the upper arm had the lowest artifact ratio, which is the ratio of the magnitude of the PPG signal after a motion and the magnitude of the PPG signal before the motion.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 460
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · cited 1×
“01 to 15 Hz [10, 11].”
Basal perfusion of the cutaneous microcirculation: Measurements as a function of anatomic position
Tur, E., Tur, M., Maibach, H. I., & Guy, R. H. (1983) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12522619 · Cited by 163
Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
Yan, Y. S., Poon, C. C. Y., & Zhang, Y. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-3 · Cited by 157
Regional Differences in the Basal and Maximal Rates of Blood Flow in the Skin
Hertzman, A. B., & Randall, W. C. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.3.234 · Cited by 92
Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes
Allen, J., & Murray, A. (2000) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20000846 · Cited by 76
Artifact reduction in photoplethysmography
Hayes, M., & Smith, P. R. (1998) · Applied Optics · doi:10.1364/ao.37.007437 · Cited by 71
Kalman Filter Based Adaptive Reduction Of Motion Artifact From Photoplethysmographic Signal
Seyedtabaii, S., & Seyedtabaii, L. (2008) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1333655 · Cited by 59
Cited by
Sorted by citations
Items 101–200 of 202
Multi-wavelength SPAD photoplethysmography for cardio-respiratory monitoring
Cusini, I., Rinaldi, R., Castiglioni, P., Faini, A., & Villa, F. (2023) · Frontiers in Physics · doi:10.3389/fphy.2023.952103 · Cited by 8
Applications of Optical Cardiovascular Monitoring
Lemay, M., Bertschi, M., Solà, J., Renevey, P., Genzoni, E., Proença, M., Ferrario, D., Braun, F., Parák, J., & Korhonen, I. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00018-8 · Cited by 8
Photoplethysmography‐Based Angiography of Skin Tumors in Arbitrary Areas of Human Body
Guryleva, A. V., Machikhin, A. S., Orlova, E. V., Kulikova, E., Volkov, M. V., Gabrielian, G. A., Smirnova, L., Sekacheva, M. I., Olisova, O. Y., Rudenko, E., et al. (2024) · Journal of Biophotonics · doi:10.1002/jbio.202400242 · Cited by 7
Continuous biosignal acquisition beyond the limit of epidermal turnover
Bhatia, A., Kasper, K. A., & Gutruf, P. (2025) · Materials Horizons · doi:10.1039/d5mh00758e · Cited by 7
TAMURA, T., & Maeda, Y. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_6 · Cited by 11
Self-citationDigital wearable devices in cardiac rehabilitation: patient need and satisfaction. Literature Review
Павловна, Л. Н., & Kharytonov, S. V. (2022) · Cardiosomatics · doi:10.17816/22217185.2022.1.201471 · Cited by 10
Ambient Light Contribution as a Reference for Motion Artefacts Reduction in Photoplethysmography
Ferreira, N. D. P., Géhin, C., & Massot, B. (2020) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0008878800002513 · Cited by 7
Obi, A. I. (2022) · International Electronic Conference on Sensors and Applications (ECSA) · doi:10.3390/engproc2021010077 · Cited by 7
Ren, B., Wang, Z., Ma, K., Zhou, Y., & Liu, M. (2023) · Information · doi:10.3390/info14050297 · Cited by 8
Fine, J. N., McShane, M. J., Coté, G. L., & Scully, C. G. (2022) · Biosensors · doi:10.3390/bios12080598 · Cited by 7
Maeda, Y., Sekine, M., TAMURA, T., Suzuki, T., & Kameyama, K.-I. (2011) · Journal of Life Support Engineering · doi:10.5136/lifesupport.23.124 · Cited by 7
Self-citationStevens, G., Hantson, L., Larmuseau, M., Heerman, J. R., Siau, V., & Verdonck, P. (2024) · Sensors · doi:10.3390/s24123766 · Cited by 6
Green Light Photoplethysmography as a Substitute for Heart Rate Variability Monitoring
Maeda, Y., Sekine, M., TAMURA, T., & Mizutani, K. (2024) · Advanced Biomedical Engineering · doi:10.14326/abe.13.301 · Cited by 6
Self-citationIwai, R., Shimazaki, T., Kawakubo, Y., Fukami, K., Ata, S., Yokoyama, T., Hitosugi, T., Otsuka, A., Hayashi, H., Tsurumoto, M., et al. (2022) · Sensors · doi:10.3390/s22072745 · Cited by 6
TAMURA, T. (2020) · Advanced Biomedical Engineering · doi:10.14326/abe.9.189 · Cited by 6
Self-citationFuhrmann, L. M., Lukas, C. A., Schindler‐Gmelch, L., & Berking, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-06588-4 · Cited by 4
Vermunicht, P., Buyck, C., Naessens, S., Hens, W., Verberckt, C., Craenenbroeck, E. M. V., Laukens, K., Desteghe, L., & Heidbüchel, H. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf084 · Cited by 5
PPGSpotter: Personalized Free Weight Training Monitoring Using Wearable PPG Sensor
Liu, X., Li, F., Cao, Y., Zhai, S., Yang, S., & Wang, Y. (2024) · IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infocom52122.2024.10621212 · Cited by 5
Chen, Y., Feng, Y., Chen, Z., Zhou, Y., Yang, Y., Ji, Q., Xu, W., Zhou, G., Gao, T., & Li, X. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3312975 · Cited by 5
Bhutta, M. A. M., Kim, S., & Kim, Y. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3544290 · Cited by 5
Gayapersad, N., Rocke, S., Ramsaroop, Z., Singh, A., & Ramlal, C. J. (2016) · International Conference on Computational Intelligence and Communication Networks (CICN) · doi:10.1109/cicn.2016.58 · Cited by 6
Pulse Wave Velocity Techniques
Li, J. (2019) · Springer eBooks · doi:10.1007/978-3-030-24701-0_6 · Cited by 5
Basic Study on Presentation Attacks against Biometric Authentication using Photoplethysmogram
Hinatsu, S., Suzuki, D., Ishizuka, H., Ikeda, S., & Oshiro, O. (2021) · Advanced Biomedical Engineering · doi:10.14326/abe.10.101 · Cited by 5
Photoplethysmographic assessment of arterial stiffness and endothelial function
Zheng, D., Yao, Y., Morrison, I., & Greenwald, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00007-4 · Cited by 7
Regalia, G., Resnati, D., & Tognetti, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00130-8 · Cited by 9
Malinverni, S., Kalisz, S., Frigerio, M., Cogozzo, C., Pedicini, G., Clignez, G., de Villenfagne, M.-A., & Farhat, D. (2025) · Resuscitation · doi:10.1016/j.resuscitation.2025.110912 · Cited by 4
Kobayashi, M., Shinohara, T., & Usuda, S. (2021) · Journal of Physical Therapy Science · doi:10.1589/jpts.33.45 · Cited by 4
Tazarv, A., Labbaf, S., Rahmani, A. M., Dutt, N. D., & Levorato, M. (2021) · International Conference on Information Technology for Social Good (GoodIT) · doi:10.1145/3462203.3475918 · Cited by 4
[Retracted] Edge‐Enabled Heart Rate Estimation from Multisensor PPG Signals
Chen, X., Zhu, F., & Zhao, H. Y. (2023) · Journal of Healthcare Engineering · doi:10.1155/2023/4682760 · Cited by 4
RetractedBenchmarking of Sensor Configurations and Measurement Sites for Out-of-the-Lab Photoplethysmography
Supelnic, M. N., Ferreira, A. F., Bota, P. J., Rosário, L. B., & Silva, H. (2023) · Sensors · doi:10.3390/s24010214 · Cited by 4
Model-based estimation of heart movements using microwave Doppler radar sensor
Ota, T., & Okusa, K. (2024) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.1186/s40101-024-00373-4 · Cited by 4
Pulse Rate Guided Oxygen Saturation Monitoring Using a Wearable Armband Sensor
Huang, N., Bian, D., Zhou, M., Mehta, P., Shah, M., Rajput, K. S., Majmudar, M. D., & Selvaraj, N. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871461 · Cited by 4
Chen, Y., Zheng, Y., Johnson, S. R., Wiffen, R., & Yang, B. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02979-9 · Cited by 4
Hsiao, C.-C., Kuo, H.-C., Lee, R.-G., & Lin, R. (2016) · International Automatic Control Conference · doi:10.1109/cacs.2016.7973917 · Cited by 4
Monitoring of the Arterial Blood Waveforms with a Multi-Sensor System
Prokop, D., Cysewska-Sobusiak, A. R., & Hulewicz, A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.09.174 · Cited by 4
Wearable oximetry for harsh environments
Telfer, B. A., Hoyt, R. W., Lacirignola, J. J., Patel, T., Siegel, A. M., Swiston, A. J., Singh, N., Trebicka, R., Weston, C., & Williamson, J. R. (2017) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2017.7936019 · Cited by 4
Photoplethysmography for bovine heat detection: the preliminary results
Cugmas, B., Plavšić, A., Štruc, E., & Spīgulis, J. (2020) · doi:10.1117/12.2543858 · Cited by 4
Adaptive Estimation Algorithm for Photoplethysmographic Heart Rate Based on Finite State Machine
Lan, T., Bie, Y., Hai, D., & Zhong, J. (2024) · Applied Sciences · doi:10.3390/app142411631 · Cited by 3
Branan, K. L., Kurian, R., McMurray, J. P., Erraguntla, M., Gutiérrez‐Osuna, R., & Coté, G. L. (2025) · Biosensors · doi:10.3390/bios15080493 · Cited by 4
Higuchi, D., Takahashi, Y. K., Tanaka, S., & Tomita, Y. (2025) · Journal of Physical Therapy Science · doi:10.1589/jpts.37.561 · Cited by 2
Reiser, M., Breidenassel, A., & Amft, O. (2025) · Scientific Reports · doi:10.1038/s41598-025-26560-6 · Cited by 4
Costantini, S., Biffi, E., Storm, F. A., Andreoni, G., & Bianchi, A. M. (2024) · IEEE International Forum on Research and Technology for Society and Industry (RTSI) · doi:10.1109/rtsi61910.2024.10761891 · Cited by 3
Bartolomeu, R. F., Silva, V., Pereira, A., Morais, G., Sokołowski, K., Strzała, M., Morais, J. E., & Teixeira, J. E. (2025) · Applied Sciences · doi:10.3390/app15115848 · Cited by 3
Gilgen-Ammann, R., Buller, M. J., Bitterle, J. L., Delves, S. K., Veenstra, B., Roos, L., Beeler, N., & Wyss, T. (2018) · Current Issues in Sport Science (CISS) · doi:10.15203/ciss_2018.011 · Cited by 3
Introducing the Pi-CON Methodology to Overcome Usability Deficits during Remote Patient Monitoring
Baumann, S., Stone, R., & Kim, J. Y. M. (2024) · Sensors · doi:10.3390/s24072260 · Cited by 3
Introduction to cardiovascular signals and automated systems
Pachori, D., Dash, S., Tripathy, R. K., & Jain, T. K. (2024) · Elsevier eBooks · doi:10.1016/b978-0-44-314141-6.00006-2 · Cited by 3
Ferreira, N. D. P., Géhin, C., & Massot, B. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175787 · Cited by 3
Model-based Assessment of Brachial Artery Diameter From Electrical Impedance Measurement
Mugeb, A.-H., & Larvushkin, A. (2021) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit51232.2021.9455041 · Cited by 3
Yan, J., & Bin, G. (2015) · Technology and Health Care · doi:10.3233/thc-150964 · Cited by 3
Fawcett, A. (2018) · UWSpace (University of Waterloo) · Cited by 3
Kostrna, J., Oparina, E., Palacios, C., Rodriguez, A. J., Pei, J., Ajmal, A., & Ramella-Roman, J. C. (2026) · Sensors · doi:10.3390/s26102922 · Cited by 5
Peng, Y., Xia, F., Shao, Z., Pala, S., Yue, W., Ding, H., Xie, J., & Lin, L. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-01019-w · Cited by 3
Moghaddam, M., Collins, J. P., Gardner, C. E., & Rabel, M. C. (2025) · Sensors · doi:10.3390/s26010176 · Cited by 3
Ortiz, R., Gonzalez, J. M., Rodgers, T. M., Torres, S. I. H., Convertino, V. A., & Snider, E. J. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1756626 · Cited by 2
Besné, G. M., López-Iturri, P., Alegre, M., Artieda, J., Trigo, J. D., Serrano, L., Falcone, F., & Valencia, M. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3314190 · Cited by 2
On the Exploitation of CEEMDAN for PPG Synthetic Data Generation
Grossi, A., Gasparini, F., & Saibene, A. (2024) · Lecture notes in bioengineering · doi:10.1007/978-3-031-63913-5_6 · Cited by 2
Hinatsu, S., Matsuda, N., Ishizuka, H., Ikeda, S., & Oshiro, O. (2022) · IEEE Access · doi:10.1109/access.2022.3221456 · Cited by 2
Integrated micro-displacement sensor and its application to photoplethysmographic sensor
Nogami, H., Inoute, R., Hayashida, Y., & Sawada, R. (2017) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.2017.8305245 · Cited by 2
Sensing Technologies for Biomedical Telemetry
Tamura, T. (2014) · Wiley eBooks · doi:10.1002/9781118893715.ch4 · Cited by 2
Self-citationFlexible and Multifunctional Skin Patch for Clinical Decision Support in Psychiatric Assessment
Kim, N., Lee, S. H., & Lee, Y. J. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202401436 · Cited by 1
A Wearable PPG-Based Monitoring System for Personalized Free Weight Training
Liu, X., Li, F., Cao, Y., Zhai, S., Shi, B., Yang, S., & Wang, Y. (2025) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2025.3540165 · Cited by 1
A Compact Multimodal Patch for Continuous and Electrode-Free Cardiopulmonary Monitoring
Semiz, B. (2025) · Gazi University Journal of Science Part A Engineering and Innovation · doi:10.54287/gujsa.1737897 · Cited by 1
Song, D., Zou, F., Wang, L., & Wang, H. (2025) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2025.111164 · Cited by 3
Deep learning ensemble approach to multi-wavelength photoplethysmogram for sleep stage detection
Park, Y., Cho, H., & Oh, J. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109689 · Cited by 1
Zhang, J., Guan, C., Wu, D., Chen, Z., Liu, G., Nie, Y., Shokouhimehr, M., He, F., & Liu, Z. (2026) · Measurement Science and Technology · doi:10.1088/1361-6501/ae3cb4 · Cited by 1
Non invasive blood glucose estimation using green light photoplethysmography and machine learning
Khan, K., Malik, L., Khan, A. Q., Abbasi, S. F., & Arvanitis, T. N. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1705086 · Cited by 3
Uendes, B., Antonides, A., van de Ven, S. R. B., van der Mee, D. J., de Geus, E. J. C., & Hoogendoorn, M. (2026) · Journal of Medical Internet Research · doi:10.2196/80450 · Cited by 1
Sivadas, R. P., Paramparambath, N., & Sidharth, N. N. (2018) · Data-Enabled Discovery and Applications · doi:10.1007/s41688-018-0020-7 · Cited by 1
Autonomous Heart Rate Tracking Methodology Using Kalman Filter and the EM Algorithm
Souza, T. T., Balasingam, B., & Maev, R. G. (2019) · International Conference on Information Fusion (FUSION) · doi:10.23919/fusion43075.2019.9011407 · Cited by 1
Smart Wake-up Stroke Alert System
Boppana, L., Kuppuru, B. K., Nerella, K. K., & Kovvada, S. (2020) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon50793.2020.9293813 · Cited by 1
Impact of an inexperienced operator on photoplethysmogram for bovine heat detection
Plavšić, A., Mavrič, T., Štruc, E., & Cugmas, B. (2023) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2650499 · Cited by 1
Robertus, H., Hendiarta, C. L., & Gunawan, A. (2023) · AIP conference proceedings · doi:10.1063/5.0109091 · Cited by 1
Pulse wave measurement system by rPPG from multiple human sites by including the sole
Takahashi, M., Yamaguchi, T., Ito, A., Renero-Carrillo, F. J., Amemiya, A., Tsumura, N., & Iijima, N. (2023) · Optics Continuum · doi:10.1364/optcon.504168 · Cited by 1
Dharangutte, P., Xie, Z., Gao, J., Schoenfeld, E. R., Hua, Y., & Ye, F. (2023) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm58861.2023.10385567 · Cited by 1
Punay, G. M., Guieb, R., Tolentino, C. T., Rosales, M. D., Co, P. J., & Hizon, J. R. E. (2024) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon61640.2024.10902829 · Cited by 1
Gosal, R., Weaver, G., Parker, H., Burkart, S. A., McAninch, J., Lane, A. D., Smith, M. T., HILL, S., PATE, R. R., Chandrashekhar, M. V. S., et al. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003841 · Cited by 1
Heart Rate Estimation During Physical Exercise Using Wrist-Type Ppg Sensors
Souza, T. T. (2019) · Scholarship at UWindsor (University of Windsor)
A Laboratory Set-up for Experimentation with the Cuffless Blood Pressure Measurement
Jabłoński, I., Głomb, G., & Morello, R. (2020) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea49120.2020.9137124
Debbarma, S., Nabavi, S. K., & Bhadra, S. (2021) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-030-76066-3_2
Respiratory Rate Estimations using Three Respiratory-Induced Variations on Photoplethysmogram
Fikriastuti, N., & Muhaimin, H. (2021) · doi:10.1109/iceei52609.2021.9611130
Zhu, Y., Sheng, M., Ouyang, Y., Zhong, L., Liu, K., Ge, T., & Wu, Y.-C. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/4066415
Gagnon, J., Khau, M., Lavoie-Hudon, L., Vachon, F., Drapeau, V., & Tremblay, S. (2022) · doi:10.2196/preprints.37885
Hardware and Algorithmic Approaches to Combat Motion Artifacts in Photoplethysmographic Data
Han, D., Mohagheghian, F., & Chon, K. H. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00135-7
Präzisionsrehabilitation im Neuroreha-Alltag
Bannwart, M. (2023) · neuroreha · doi:10.1055/a-2180-9134
Deep Neural Network to Remove Motion Artifacts from Heart Rate Sensor Embedded on Handle Cane
Villalba-Bravo, R., Ruiz-Barroso, P., Castro, F. M., Trujillo-León, A., Guil, N., & Vidal‐Verdú, F. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10784567
Heart Rate Estimation From Photoplethysmography Signals Using Fast Fourier Transform
Mohan, N., Awwad, F. R., Bastaki, N., & Atef, M. (2024) · International Conference on Signal Processing and Information Security (ICSPIS) · doi:10.1109/icspis63676.2024.10812645
Crepaldi, S. C., Wang, J., Matsumoto, F., Takeuchi, H., Watanabe, T., & Yamamoto, Y. (2025) · Sensors · doi:10.3390/s25144315
Malinverni, S., Kalisz, S., Frigerio, M., Cogozzo, C., Pedicini, G., Clignez, G., de Villenfagne, M.-A., & Farhat, D. (2025) · medRxiv · doi:10.1101/2025.08.01.25332657
Wang, C.-F., Wang, H., Kuo, P.-H., Li, S.-Z., Chen, B., Li, S., Chen, Y., & Lin, S.-H. (2025) · American Journal of Hypertension · doi:10.1093/ajh/hpaf238
Research on Risk Assessment of Arterial Stiffness by Using Photoplethysmogram in Young people
Sun, Y., & Abe, M. (2025) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.146.19
Benkert, A., Bludau, J., Boborzi, L., Prueckner, S., & Schniepp, R. (2026) · Sensors · doi:10.3390/s26010324 · Cited by 1
Research on heart rate estimation algorithm based on dynamic PPG
Guo, J., Chen, S., Lan, T., Li, R., Wang, L., Wu, Y., Zhong, J., & Zhu, W. (2026) · Frontiers in Signal Processing · doi:10.3389/frsip.2026.1724468
EmotionVibe: Human Emotion Recognition Through Footstep-Induced Floor Vibrations
Wu, Y., Dong, Y., Vaid, S. S., Harari, G. M., & Noh, H. Y. (2026) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2026.3666144 · Cited by 2
Li, X., Zhang, Y. M., Xu, Y., Zhu, Z., Liang, Z., Song, D., Qiao, B., & Zhao, S. (2026) · Journal of Materials Chemistry C · doi:10.1039/d6tc00068a
Noninvasive Estimation of Glycated Hemoglobin: A Comprehensive Review of Emerging Technologies
Saini, S. K., Tiwari, S., Joshi, A. M., & Maddila, R. K. (2026) · IETE Technical Review · doi:10.1080/02564602.2026.2701257
Joshi, M., Shukla, P. K., Sindagi, Y. R., Mohana, Kulkarni, N. N., & Sudarshan, B. G. (2026) · IEEE Access · doi:10.1109/access.2026.3720255
Motion-Artifact-Suppressed Pulse Wave Monitoring Based on an Iontronic Pressure Sensor
Tang, S., Zhang, Z., Li, L., Lin, L., Wang, Z., & Yu, Z. (2026) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems69704.2026.11633767
Temple PPG Morphology Demonstrates a Stronger Cardiovascular Age Signal Than Wrist SitesPreprint
Liu, D., Dutta, A., & Nadig, S. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.19.745616
Lee, W., 신재연, Song, M., Song, M.-K., Kim, K. M., Noh, G., & Cho, S. P. (2026) · Sensors · doi:10.3390/s26175676
Metadata
- Authors
- Maeda, Y., Sekine, M., & Tamura, T.
- Affiliations
- Chiba University (JP)
- Corresponding author
- Maeda, Yuka
- Venue
- Journal of Medical Systems
- Published
- 2010-05-07
- Volume
- 35
- Issue
- 5
- Pages
- 969-976
- ISSN
- 0148-5598 (ISSN-L)
- 1573-689X
- OpenAlex
- W1974364930
- Cited by
- 203
- References
- 12
- Citations by year
- 2026: 17 · 2025: 23 · 2024: 24 · 2023: 20 · 2022: 22 · 2021: 24 · 2020: 24 · 2019: 11 · 2018: 8 · 2017: 5 · 2016: 6 · 2015: 8 · 2014: 6 · 2013: 3 · 2012: 1
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- photoplethysmography, motion artifacts, wearable sensors, pulse rate monitoring, upper arm, exercise monitoring
- MeSH terms
- Adult, Heart Rate, Humans, Infrared Rays, Light, Male, Movement, Signal Processing, Computer-Assisted, Photoplethysmography, Upper Extremity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review