Relationship Between Measurement Site and Motion Artifacts in Wearable Reflected Photoplethysmography
Abstract
Pulse rates obtained from wearable photoplethysmography (PPG) sensors are important for monitoring cardiovascular condition, especially during exercise. However, it is difficult to precisely count pulse rates during exercise because PPG is sensitive to body movement. The artifacts from body movement are caused by a change in the blood volume at the measurement site, in addition to pulsatile changes. Here, we investigated the influence of motion artifact with respect to light source and anatomical sites. In this study, we compared the signal from green-light PPG to that from infrared PPG at different anatomical sites. In these experiments, 11 subjects were asked to either assume a resting position or generate spontaneous motion artifact by jumping and swinging their arm. As a result, pulse rates obtained from green-light PPG showed a higher correlation with the ECG R-R interval as compared to those obtained with infrared. Additionally, the signal from the upper arm showed less artifact than did the peripheral one. Therefore, the green-light PPG may be useful for pulse rate monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We therefore interpret intensity-linked improvements as modest rather than decisive, but they do suggest that PPG systems may perform comparatively better when stroke volume and pulsatility increase [2,29].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [29]
In the citing paper
“and has displayed more accurate measurement of heart rate in conjunction with an accelerometer compared to an infrared heart rate system when compensating for movement artifacts (Maeda, Sekine, Tamura, 2011b).”
From Examining the Role of Implicit Emotional Judgments in Social Anxiety and Experiential Avoidance (2017) · cites this paper as Maeda, Sekine, Tamura, 2011b
In the citing paper
“Motion artifacts are a primary cause of bad signal quality, and research has suggested various methods for mitigating these26,39,40.”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [39]
In the citing paper
“Nevertheless, these artifact characteristics cannot be straightforwardly transferred to simulating the wrist PPG since distinct body locations have different tissue optical properties for different wavelengths and are prone to specific interference [54].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [54]
In the citing paper
“These alternative sites can have advantages over the wrist, such as being less prone to motion artifact [63] or vasoconstriction [62], and providing more accurate HR measurements [64].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [63]
In the citing paper
“During sedentary moments, respiration rate, thermoregulation, and sympathetic nervous system activity cause the DC baseline to wander [162].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“The green sensor also had a lower artifact ratio for all locations compared to the IR sensor.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“With their longer wavelengths, red and IR have deeper penetration depths compared to blue and green, making them prone to more motion artifacts such as the factors that directly affect the DC baseline [162,164].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“The highest correlation coefficient between the PPG signal and a chest ECG was that of the green sensor on the upper arm.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
In the citing paper
“They found the upper arm had the lowest artifact ratio, which is the ratio of the magnitude of the PPG signal after a motion and the magnitude of the PPG signal before the motion.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [162]
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 460
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · cited 1×
“01 to 15 Hz [10, 11].”
Basal perfusion of the cutaneous microcirculation: Measurements as a function of anatomic position
Tur, E., Tur, M., Maibach, H. I., & Guy, R. H. (1983) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12522619 · Cited by 163
Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
Yan, Y. S., Poon, C. C. Y., & Zhang, Y. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-3 · Cited by 157
Regional Differences in the Basal and Maximal Rates of Blood Flow in the Skin
Hertzman, A. B., & Randall, W. C. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.3.234 · Cited by 92
Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes
Allen, J., & Murray, A. (2000) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20000846 · Cited by 76
Artifact reduction in photoplethysmography
Hayes, M., & Smith, P. R. (1998) · Applied Optics · doi:10.1364/ao.37.007437 · Cited by 71
Kalman Filter Based Adaptive Reduction Of Motion Artifact From Photoplethysmographic Signal
Seyedtabaii, S., & Seyedtabaii, L. (2008) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1333655 · Cited by 59
Cited by
Sorted by citations
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“and distance between the light source and the sensor [69], [73].”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“In recent years, different measurement sites for PPG sensors have been explored extensively, including the ring finger [14], wrist [15,16], brachia [9,17,18], earlobe [19–21], external ear cartilage [22–24], and the superior auricular region [25–27].”
BackgroundSelf-citationMonitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Current progress of photoplethysmography and SPO2 for health monitoring
TAMURA, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 274
Self-citationJinno, H., Yokota, T., Koizumi, M., Yukita, W., Saito, M., Osaka, I., Fukuda, K., & Someya, T. (2021) · Nature Communications · doi:10.1038/s41467-021-22558-6 · Cited by 253
Lee, J., Matsumura, K., Yamakoshi, K.-I., Rolfe, P., Tanaka, S., & Yamakoshi, T. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609852 · Cited by 202
Hartmann, V., Liu, H., Chen, F., Qiu, Q., Hughes, S., & Zheng, D. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00198 · Cited by 173
Salehizadeh, S. M. A., Dao, D. K., Bolkhovsky, J., Cho, C. H., Mendelson, Y., & Chon, K. H. (2015) · Sensors · doi:10.3390/s16010010 · Cited by 176
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155
Longmore, S. K., Lui, G. Y., Naik, G. R., Breen, P. P., Jalaludin, B. B., & Gargiulo, G. D. (2019) · Sensors · doi:10.3390/s19081874 · Cited by 133
Min, S., An, J., Lee, J. H., Kim, J. H., Joe, D. J., Eom, S. H., Yoo, C. D., Ahn, H., Hwang, J.-Y., Xu, S. H., et al. (2025) · Nature Reviews Cardiology · doi:10.1038/s41569-025-01127-0 · Cited by 155
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 134
Wearable and implantable biosensors: mechanisms and applications in closed-loop therapeutic systems
Zheng, Z., Zhu, R., Peng, I., Xu, Z., & Jiang, Y. (2024) · Journal of Materials Chemistry B · doi:10.1039/d4tb00782d · Cited by 131
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113
Wearable devices for continuous monitoring of biosignals: Challenges and opportunities
Stuart, T., Hanna, J., & Gutruf, P. (2022) · APL Bioengineering · doi:10.1063/5.0086935 · Cited by 121
Ye, Y., Cheng, Y., He, W., Hou, M., & Zhang, Z. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2597265 · Cited by 94
Data quality evaluation in wearable monitoring
Böttcher, S., Vieluf, S., Bruno, E., Joseph, B., Epitashvili, N., Biondi, A., Zabler, N., Glasstetter, M., Dümpelmann, M., Van Laerhoven, K., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-25949-x · Cited by 91
Sensors Capabilities, Performance, and Use of Consumer Sleep Technology
de Zambotti, M., Cellini, N., Menghini, L., Sarlo, M., & Baker, F. C. (2020) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2019.11.003 · Cited by 95
Matsumura, K., Rolfe, P. J., Lee, J., & Yamakoshi, T. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091205 · Cited by 72
Wearable Sensor System to Monitor Physical Activity and the Physiological Effects of Heat Exposure
Pham, S., Yeap, D., Escalera, G., Basu, R., Wu, X., Kenyon, N. J., Hertz‐Picciotto, I., Ko, M., & Davis, C. E. (2020) · Sensors · doi:10.3390/s20030855 · Cited by 70
Simone, G., Tordera, D., Delvitto, E., Peeters, B., van Breemen, A. J. J. M., Meskers, S. C. J., Janssen, R. A. J., & Gelinck, G. H. (2020) · Advanced Optical Materials · doi:10.1002/adom.201901989 · Cited by 64
Sartor, F., Gelissen, J., van Dinther, R., Roovers, D., Papini, G. B., & Coppola, G. (2018) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-018-0098-0 · Cited by 65
A Robust Fusion Method for Motion Artifacts Reduction in Photoplethysmography Signal
Nabavi, S. K., & Bhadra, S. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3006636 · Cited by 60
Validation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59
Susana, E., Ramli, K., Murfi, H., & Apriantoro, N. H. (2022) · Information · doi:10.3390/info13020059 · Cited by 59
Grubb, M., Carpenter, J., Crowe, J. A., Teoh, J. Y., Marlow, N., Ward, C., Mann, C., Sharkey, D., & Hayes‐Gill, B. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/881 · Cited by 56
In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?
Passler, S., Müller, N., & Senner, V. (2019) · Sensors · doi:10.3390/s19173641 · Cited by 60
Wrist-Worn Hand Gesture Recognition While Walking via Transfer Learning
Kang, P., Li, J., Fan, B., Jiang, S., & Shull, P. B. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3100099 · Cited by 55
Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits.
Henry, B., Merz, M., Hoang, H., Abdulkarim, G., Wosik, J., & Schoettker, P. (2024) · Blood Pressure · doi:10.1080/08037051.2024.2304190 · Cited by 55
Li, J., Chu, H., Chen, Z., Yiu, C. K., Qu, Q., Li, Z.-Y., & Yu, X. (2024) · ACS Nano · doi:10.1021/acsnano.4c04291 · Cited by 50
A Review of Noninvasive Methodologies to Estimate the Blood Pressure Waveform
Athaya, T., & Choi, S. (2022) · Sensors · doi:10.3390/s22103953 · Cited by 58
Convertino, V. A., Schauer, S. G., Weitzel, E. K., Cardin, S., Stackle, M. E., Talley, M. J., Sawka, M. N., & Inan, O. T. (2020) · Sensors · doi:10.3390/s20226413 · Cited by 49
Virtual reality sickness detection: an approach based on physiological signals and machine learning
Martin, N., Mathieu, N., Pallamin, N., Ragot, M., & Diverrez, J.-M. (2020) · Proceedings - International Symposium on Mixed and Augmented Reality, ISMAR · doi:10.1109/ismar50242.2020.00065 · Cited by 50
Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities
Claes, J., Buys, R., Ávila, A., Finlay, D., Kennedy, A., Guldenring, D., Budts, W., & Cornelissen, V. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1333166 · Cited by 49
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Sañudo, B., De Hoyo, M., Muñoz-López, A., Perry, J., & Abt, G. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1325-2 · Cited by 48
Liu, H., Allen, J., Khalid, S. G., Chen, F., & Zheng, D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac0a34 · Cited by 50
Gong, S. P., Yap, L. W., Zhang, Y., He, J., Yin, J., Marzbanrad, F., Kaye, D. M., & Cheng, W. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114072 · Cited by 50
Application of Optical Heart Rate Monitoring
Lemay, M., Bertschi, M., Solà, J., Renevey, P., Parák, J., & Korhonen, I. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-418662-0.00023-4 · Cited by 46
Xu, K., Jiang, X., & Chen, W. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2960370 · Cited by 46
Landry, C., Peterson, S. D., & Arami, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2967759 · Cited by 45
Nardelli, M., Vanello, N., Galperti, G., Greco, A., & Scilingo, E. P. (2020) · Sensors · doi:10.3390/s20113156 · Cited by 47
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 46
Comparison of Green, Blue and Infrared Light in Wrist and Forehead Photoplethysmography
Vizbara, V. (2013) · Cited by 40
Dur, O., Rhoades, C. E., Ng, M. S., Elsayed, R., van Mourik, R. A., & Majmudar, M. D. (2018) · JMIR mhealth and uhealth · doi:10.2196/11040 · Cited by 38
Zhou, C., Feng, J., Hu, J. H., & Ye, X. (2015) · Journal of Medical Systems · doi:10.1007/s10916-015-0412-2 · Cited by 39
Xu, K., Jiang, X., Lin, S., Dai, C., & Chen, W. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2988097 · Cited by 37
Validity of Ultra-Short-Term HRV Analysis Using PPG—A Preliminary Study
Taoum, A., Bisiaux, A., Tilquin, F., Guillou, Y. L., & Carrault, G. (2022) · Sensors · doi:10.3390/s22207995 · Cited by 37
Determinants of photoplethysmography signal quality at the wrist
Charlton, P. H., Marozas, V., Mejía‐Mejía, E., Kyriacou, P. A., & Mant, J. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0000585 · Cited by 38
Kim, J., Kim, J.-H., & Ko, H. (2015) · Sensors · doi:10.3390/s16010046 · Cited by 36
Accurate Blood Pressure Estimation During Activities of Daily Living: A Wearable Cuffless Solution
Landry, C., Hedge, E. T., Hughson, R. L., Peterson, S. D., & Arami, A. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3054597 · Cited by 36
Zhang, Y., Gu, T., Luo, C., Kostakos, V., & Seneviratne, A. P. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3191788 · Cited by 37
Effects of skin surface temperature on photoplethysmograph
Jeong, I. C., Yoon, H., Kang, H., & Yeom, H. (2014) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.5.4.429 · Cited by 33
Lam, E., Aratia, S., Wang, J., & Tung, J. Y. (2020) · JMIR Biomedical Engineering · doi:10.2196/17355 · Cited by 36
A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods
Desquins, T., Bousefsaf, F., Pruski, A., & Maaoui, C. (2022) · Applied Sciences · doi:10.3390/app12199582 · Cited by 35
Optical heart rate monitoring module validation study
Valenti, G., & Westerterp, K. R. (2013) · 2013 IEEE International Conference on Consumer Electronics (ICCE) · doi:10.1109/icce.2013.6486856 · Cited by 32
Accuracy and Reliability of Pulse O2 Saturation Measured by a Wrist-worn Oximeter
Hermand, É., Coll, C., Richalet, J., & Lhuissier, F. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1337-2790 · Cited by 33
Study of a Ring-Type Surgical Pleth Index Monitoring System Based on Flexible PPG Sensor
Zhou, C., Wang, H., Zhang, Y., & Ye, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3041072 · Cited by 29
Real time heart rate detection from PPG signal in noisy environment
Das, S., Pal, S., & Mitra, M. (2016) · International Conference on Intelligent Control Power and Instrumentation (ICICPI) · doi:10.1109/icicpi.2016.7859676 · Cited by 27
Matsumura, K., Toda, S., & Kato, Y. (2020) · IEEE Access · doi:10.1109/access.2020.2990438 · Cited by 27
Advances in Photoplethysmography for Personalized Cardiovascular Monitoring
Kim, S., Xiao, X., & Chen, J. (2022) · Biosensors · doi:10.3390/bios12100863 · Cited by 25
Uncertainties in the Analysis of Heart Rate Variability: A Systematic Review
Lü, L., Zhu, T., Morelli, D., Creagh, A. P., Liu, Z., Yang, J., Liu, F., Zhang, Y., & Clifton, D. A. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3271595 · Cited by 28
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24
Gagnon, J., Khau, M., Lavoie-Hudon, L., Vachon, F., Drapeau, V., & Tremblay, S. (2022) · JMIR Formative Research · doi:10.2196/37885 · Cited by 23
Cugmas, B., Štruc, E., & Spīgulis, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaf433 · Cited by 24
Wang, C.-F., Wang, T.-Y., Kuo, P.-H., Wang, H., Li, S.-Z., Lin, C., Chan, S.-C., Liu, T., Lo, Y., Lin, S.-H., et al. (2023) · Biosensors · doi:10.3390/bios13030321 · Cited by 24
Indoor Self‐Powered Perovskite Optoelectronics with Ultraflexible Monochromatic Light Source
Jinno, H., Shivarudraiah, S. B., Rasmussen, A., Vagli, G., Marcato, T., Eickemeyer, F. T., Pfeifer, L., Yokota, T., Someya, T., & Shih, C. (2023) · Advanced Materials · doi:10.1002/adma.202304604 · Cited by 23
Volpes, G., Valenti, S., Genova, G., Barà, C., Parisi, A., Faes, L., Busacca, A., & Pernice, R. (2024) · Biosensors · doi:10.3390/bios14040205 · Cited by 25
Rational selection of RGB channels for disease classification based on IPPG technology
Xu, G., Dong, L., Yuan, J., Zhao, Y., Liu, M., Hui, M., Zhao, Y., & Kong, L. (2022) · Biomedical Optics Express · doi:10.1364/boe.451736 · Cited by 24
Characterization of Artifact Signals in Neck Photoplethysmography
García-López, I., & Rodriguez–Villegas, E. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2972378 · Cited by 22
Intelligent sensing devices and systems for personalized mental health
Xing, Y., Yang, Y., Yang, K., Lu, A., Xing, L., Mackie, K., & Guo, F. (2025) · Med-X · doi:10.1007/s44258-025-00057-3 · Cited by 25
Puranen, A., Halkola, T., Kirkeby, O., & Vehkaoja, A. T. (2020) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47125.2020.9278523 · Cited by 19
Fabric‐Based Ultrasonic Sensor with Integrated Piezoelectric Composite for Blood Pressure Monitoring
Li, B., Wang, T., Luo, D., Peng, P., Wang, Y., Liu, L., Wang, H., & Liu, H. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201814 · Cited by 20
Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities
Shumate, T., Link, M., Furness, J. W., Kemp‐Smith, K., Simas, V., & Climstein, M. (2021) · PeerJ · doi:10.7717/peerj.10893 · Cited by 19
Reali, P., Lolatto, R., Coelli, S., Tartaglia, G., & Bianchi, A. M. (2022) · Sensors · doi:10.3390/s22041428 · Cited by 21
Wu, Z., Li, X., Feng, Z., Wan, C., Ya, L., Li, T., Yang, Q., Liu, X., Ren, M., Li, J., et al. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202629 · Cited by 20
Buddhika, T., Zhang, H., Chan, S., Dissanayake, V., Nanayakkara, S. C., & Zimmermann, R. (2019) · Augmented Human International Conference · doi:10.1145/3311823.3311839 · Cited by 18
Sinichi, M., Gevonden, M. J., & Krabbendam, L. (2025) · Psychophysiology · doi:10.1111/psyp.70004 · Cited by 26
Lin, Z., Zhang, J., Chen, Y., & Zhang, Q. (2015) · International Conference on Communications · doi:10.1109/icc.2015.7248369 · Cited by 17
Examining the Role of Implicit Emotional Judgments in Social Anxiety and Experiential Avoidance
Levin, M. E., Haeger, J., & Smith, G. S. (2017) · Journal of Psychopathology and Behavioral Assessment · doi:10.1007/s10862-016-9583-5 · Cited by 16
Yan, J., Ye, Z., Shi, F., Dai, Y., Yang, L., Wu, J., & Wang, Y. (2021) · Biomedical Optics Express · doi:10.1364/boe.437805 · Cited by 16
Giovanni, E. D., Srinivasan Murali, A., Rincón, F. J., & Atienza, D. (2016) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2016.101 · Cited by 15
Motion Artifact Detection in PPG Signals Based on Gramian Angular Field and 2-D-CNN
Liu, X., Hu, Q., Yuan, H., & Yang, C. (2020) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei51763.2020.9263630 · Cited by 15
Hayirlioglu, Y. Z., & Semiz, B. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3403846 · Cited by 13
Hsiao, C.-C., Horng, J., Lee, R.-G., & Lin, R. (2017) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2017.8123084 · Cited by 13
van Es, V. A. A., Lathauwer, I. L. J. D., Kemps, H., Handjaras, G., & Betta, M. (2024) · Bioengineering · doi:10.3390/bioengineering11101045 · Cited by 12
Ceugniez, M., Devanne, H., & Hermand, É. (2024) · JMIR mhealth and uhealth · doi:10.2196/54871 · Cited by 13
Measurement of Blood Pressure via a Skin-Mounted, Non-Invasive Pressure Sensor
Li, S., Park, Y., Luan, H., Wang, H., Kwon, K., Rogers, J. A., & Huang, Y. Y. (2021) · Journal of Applied Mechanics · doi:10.1115/1.4051183 · Cited by 12
mWIoTAuth: Multi-wearable data-driven implicit IoT authentication
Vhaduri, S., Dibbo, S. V., Muratyan, A., & Cheung, W. (2024) · Future Generation Computer Systems · doi:10.1016/j.future.2024.05.025 · Cited by 12
Non-invasive measurement of pulse waves in the soles of rats using an RGB camera
Takahashi, M., Yamaguchi, T., Takahashi, R., Ogawa‐Ochiai, K., Tsumura, N., & Iijima, N. (2021) · OSA Continuum · doi:10.1364/osac.433228 · Cited by 11
Wearable Upper Arm SpO 2 Sensor for Wellness Monitoring
Kinnunen, M. T., Behfar, M. H., Santaniemi, N., Happonen, T., Nguyen, D. H. P., Kilpijärvi, J., Jaako, T., Happonen, J., Russell, M. K., Clermont, C. A., et al. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3521189 · Cited by 10
Novel Continuous Respiratory Rate Monitoring Using an Armband Wearable Sensor
Huang, N., Zhou, M., Bian, D., Mehta, P., Shah, M., Rajput, K. S., & Selvaraj, N. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630025 · Cited by 10
Abe, M., Yoshizawa, M., Obara, K., Sugita, N., Homma, N., & Yambe, T. (2015) · Advanced Biomedical Engineering · doi:10.14326/abe.4.1 · Cited by 10
Wearable photoplethysmography devices
Charlton, P. H., & Marozas, V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00011-6 · Cited by 10
Raw Photoplethysmography as an Enhancement for Research-Grade Wearable Activity Monitors
Hibbing, P. R., & Khan, M. M. (2024) · JMIR mhealth and uhealth · doi:10.2196/57158 · Cited by 10
Li, D., Xu, Y., & Gao, W. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105156 · Cited by 10
Bubb, C. A. B., Weber, M., Kretsch, N., Heim, R. R., Zellhuber, I., Schmid, S., Kagerbauer, S. M., Kreuzer, J., Schaller, S. J., Blobner, M., et al. (2023) · Digital Health · doi:10.1177/20552076231211169 · Cited by 9
Metadata
- Authors
- Maeda, Y., Sekine, M., & Tamura, T.
- Affiliations
- Chiba University (JP)
- Corresponding author
- Maeda, Yuka
- Venue
- Journal of Medical Systems
- Published
- 2010-05-07
- Volume
- 35
- Issue
- 5
- Pages
- 969-976
- ISSN
- 0148-5598 (ISSN-L)
- 1573-689X
- OpenAlex
- W1974364930
- Cited by
- 203
- References
- 12
- Citations by year
- 2026: 17 · 2025: 23 · 2024: 24 · 2023: 20 · 2022: 22 · 2021: 24 · 2020: 24 · 2019: 11 · 2018: 8 · 2017: 5 · 2016: 6 · 2015: 8 · 2014: 6 · 2013: 3 · 2012: 1
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- photoplethysmography, motion artifacts, wearable sensors, pulse rate monitoring, upper arm, exercise monitoring
- MeSH terms
- Adult, Heart Rate, Humans, Infrared Rays, Light, Male, Movement, Signal Processing, Computer-Assisted, Photoplethysmography, Upper Extremity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review