The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index; 2 of the 8 sources its claims cite were checked for support.
Fault-tolerant control for an electro-hydraulic servo system with sensor fault compensation and disturbance rejection
Open accessAbstract
The electro-hydraulic servo system (EHSS) usually faces multiple sensor faults and disturbances, which is difficult to achieve good tracking control, reliability, and stability control.
Overview
CoChat Summary
TL;DR
This paper proposes a fault-tolerant control scheme for an electro-hydraulic servo system that combines three nonlinear unknown input observers (NUIOs) for simultaneous position, velocity, and load-pressure sensor fault detection/estimation/isolation, two extended state observers (ESOs) for matched/unmatched disturbance rejection, and dynamic surface control (DSC) to avoid backstepping complexity. Simulation studies show improved tracking under multiple sensor faults and lumped disturbances compared with controllers lacking NUIO or ESOs.
Key findings
- Three NUIOs estimated position, velocity, and load-pressure sensor faults; when all three faults occurred simultaneously at t = 5 s, they were detected at 5.26 s, 5.55 s, and 5.37 s, respectively, and isolated.
- In sinusoidal tracking (Case 1), the proposed controller had RMS error 0.046 mm versus DSNUIO 0.1337 mm and DSESO 17.1859 mm; maximum errors were 0.5087 mm, 0.5336 mm, and 20.5805 mm, respectively.
- In multistep tracking (Case 2), the proposed controller had RMS error 0.0179 mm versus DSNUIO 0.0466 mm and DSESO 17.2089 mm; maximum errors were 0.4843 mm, 0.4916 mm, and 21.5574 mm, respectively.
- ESOs estimated matched and unmatched disturbances, and Lyapunov analysis indicates uniformly ultimately bounded tracking errors and system states under lumped disturbances and faulty conditions.
Methods
- Design: three NUIOs via LMI for sensor fault/state estimation, two ESOs for matched/unmatched disturbances, and a DSC-based FTC with reconfiguration using the NUIO 1 position estimate when a position sensor fault is detected.
- Data/sample: MATLAB/Simulink simulations of a symmetric EHSS with parameters in Table 1; sinusoidal and multistep reference tracking; sensor faults introduced at t = 5 s; comparisons against DSESO (no NUIO) and DSNUIO (no ESOs).
- Analysis: tracking performance evaluated by RMS and maximum tracking errors; fault detection, estimation, and isolation assessed via NUIO outputs and predefined thresholds.
Limitations
- Stated: only bias sensor faults are modeled; partial loss of effectiveness and outage sensor faults are left for future work. Future work also includes measurement noises, other actuator faults, and experimental data with multi-sensor and actuator fault diagnosis.
- Stated: data sharing is not applicable because no datasets were generated or analyzed.
- Evident: validation is simulation-only, with no experimental results; the design relies on assumptions that all system states are measurable, disturbances and their derivatives are bounded, and the nonlinear function satisfies a Lipschitz condition.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 2 Not valid · 2 Not checked · 47 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“In [21, 24, 25], authors are only interested to position sensor fault identification for EHSS.”
What the sources say
- Not checked — no full text of the sourcecites [21] Phan, V.D., Ahn, K.K.: Observer-based fault-tolerant control of an electro-hydraulic actuator with mismatched disturbance. In: 24th International conference on mechatronics technology (ICMT) (2021) source
- Not checked — no full text of the sourcecites [24] Nahian, S.A., Truong, D.Q., Chowdhury, P., Das, D., Ahn, K.K.: Modeling and fault tolerant control of an electro-hydraulic actuator. Int. J. Precis. Eng. Manuf. 17(10), 1285–1297 (2016) source
- Disputedcites [25] Phan, V.D., Vo, C.P., Dao, H.V., Ahn, K.K.: Robust fault-tolerant control of an electro-hydraulic actuator with a novel nonlinear unknown input observer. IEEE Access 9, 30750–30760 (2021) sourceExperimental — accuracy not yet measured
Section III says the paper identifies position-sensor faults, but it also develops a fault-tolerant controller to address mismatched disturbances and an adaptive law to handle internal leakage faults. The Introduction likewise describes these as simultaneous concerns. Thus, the claim that the authors are *only* interested in position-sensor fault identification is contrary to the source. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: unclear — It is unclear why the paper says it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Different from the FTC strategy suggested in [12], the sensor malfunctions were not compensated.”
What the sources say
- Supportedcites [12] Phan, V.D., Vo, C.P., Dao, H.V., Ahn, K.K.: Actuator fault-tolerant control for an electro-hydraulic actuator using time delay estimation and feedback linearization. IEEE Access 9, 107111–107123 (2021) source
The paper distinguishes sensor faults from actuator faults in “Matched, Mismatched Disturbance, and Internal Leakage Fault” (page not available), then focuses its controller on internal leakage. The Simulation Setup (page not available) tests disturbances and internal leakage, not sensor malfunctions, supporting the claim that the proposed strategy did not compensate for them. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Finally, simulation studies and evaluation results are performed to demonstrate the validity of the proposed FTC algorithm.”
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“When the sensor fault is identified, and its estimation value exceeds the predefined thresholds, the NUIO successfully detects a fault.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“On the contrary, the relevant controllers, i.e., the proposed controller, DSNUIO can tackle the effect of the displacement sensor fault because of the support of the NUIO.”
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
33 more claims
Create a free account to see all 52 claims and every source verdict.
- It may state two separate claims as one. 11
- Probably not a substantial claim. 3
- The quote only partly states this claim. 1
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ 5.2.2 Tracking performance validation · p. 14
“The result of maximum errors is 0.5324 (proposed controller) and 0.4655 (DSNUIO) in case 3, it confirms the efficacy of the proposed strategy over the DSNUIO method.”
§ 5.2.2 Tracking performance validation · p. 14
“Meanwhile, the proposed controller brings less tracking error thanks to ESOs as a compensation part.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ 3 NUIO-based fault identification for EHSS · p. 5
“When the sensor faults were identified and detected, only the position sensor fault information is used to fed to the integrated controller. Other sensor faults, i.e., velocity, load pressure sensor fault, are detected for the alarm proposal.”
§ 4 Observer-based fault-tolerant tracking control · p. 6
“Since the position, velocity, and load pressure sensor fault occurs, the estimation values of the component sensor of NUIO 1-3 are implemented instead of the measurement value to eliminate the influences of the sensor failure.”
Citations
Cites
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
A Survey of Fault Detection, Isolation, and Reconfiguration Methods
Hwang, I., Kim, S., Kim, Y., & Seah, C. E. (2010) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2009.2026285 · Cited by 1,305 · cited 1×
“The fault diagnosis is a powerful component of designing an FTC for any system which includes fault detection (FD), fault estimation (FE), and fault isolation (FI) [16].”
BackgroundAdaptive Neural Control of Uncertain MIMO Nonlinear Systems
Ge, S. S., & Wang, C. (2004) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2004.826130 · Cited by 971 · cited 1×
“Lemma 1 ([37]) For a time-varying positive function Lf(t) C 0, Vt [ [0, ?] and Lf(0) bounded.”
BackgroundYao, J., Jiao, Z., & Ma, D. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2304912 · Cited by 708 · cited 1×
“Therefore, two ESOs [10, 38] can be elaborated as follows:”
BackgroundA Robust Observer-Based Sensor Fault-Tolerant Control for PMSM in Electric Vehicles
Kommuri, S. K., Defoort, M., Karimi, H. R., & Veluvolu, K. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2590993 · Cited by 408 · cited 1×
“In [18, 19], the authors suggested a sensor fault detection method based on one Luenberger observer and two higher-order sliding mode observers for a permanent magnet synchronous motor.”
MethodWon, D., Kim, W., Shin, D., & Chung, C. C. (2015) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2014.2325895 · Cited by 294 · cited 1×
“The parameter uncertainties D1 and D2 can be defined as follows [36]: D1 1⁄4 Dbm _ xp;D2 1⁄4 Dpbx2 Dpcx3; ð4Þ”
BackgroundForce control for hydraulic load simulator using self-tuning grey predictor – fuzzy PID
Truong, D. Q., & Ahn, K. K. (2009) · Mechatronics · doi:10.1016/j.mechatronics.2008.07.007 · Cited by 213
Self-citationRISE-Based Adaptive Control of Hydraulic Systems With Asymptotic Tracking
Yao, J., Deng, W., & Jiao, Z. (2017) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2015.2434393 · Cited by 200 · cited 1×
“Recently, to deal with disturbances/uncertainties, an effective control technique was utilizing different robust strategies, but it was not suitable with the increase in the uncertainty nonlinearities [8, 9].”
MethodRobust Sensors-Fault-Tolerance With Sliding Mode Estimation and Control for PMSM Drives
Kommuri, S. K., Lee, S. B., & Veluvolu, K. C. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2783888 · Cited by 140 · cited 1×
“In [18, 19], the authors suggested a sensor fault detection method based on one Luenberger observer and two higher-order sliding mode observers for a permanent magnet synchronous motor.”
MethodWon, D., Kim, W., & Tomizuka, M. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2985619 · Cited by 107 · cited 1×
“Remark 1 Note of the Assumption 1a, c: These are common assumptions that has been conducted in literature, for instance [1, 4, 12] to facilitate verifying the system stability.”
Background
Cited by
Truong, H. V. A., Nam, S., Kim, S., Kim, Y., & Chung, W. K. (2024) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2023.3323148 · Cited by 39
“The reason is because the modeling of g 3 mainly depends on the hydraulic dynamics [18], [19] such as pipeline length, gradient cross-section areas of two chambers, total volumes, pressure supply, valve coefficient, and other hydraulic setups which were not changed during two case studies.”
BackgroundResultAdaptive control of n-link hydraulic manipulators with gravity and friction identification
Liang, X., Yao, Z., Deng, W., & Yao, J. (2023) · Nonlinear Dynamics · doi:10.1007/s11071-023-08850-8 · Cited by 40
Liu, M., Xu, N., Wang, H., et al. (2025) · Nonlinear Dynamics · doi:10.1007/s11071-025-11011-8 · Cited by 30
“Subsequently, the authors in [25] proposed a fault-tolerant control scheme based on fault observer for a specific electro-hydraulic servo system with sensor faults.”
Jing, C., Zhang, H., Yan, B., Hui, Y., & Xu, H. (2024) · Nonlinear Dynamics · doi:10.1007/s11071-024-09935-8 · Cited by 29
Fault diagnosis and prognosis capabilities for wind turbine hydraulic pitch systems
Dallabona, A., Blanke, M., Pedersen, H. C., & Papageorgiou, D. (2024) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2024.111941 · Cited by 32
“The most recent and relevant results for detection/estimation and mitigation appear in [26, 60, 1, 4, 54, 12, 68, 40, 27, 64, 55, 58, 66, 16, 13, 56, 25, 59] and [43, 15, 50, 52, 51, 67].”
Background
Metadata
- Authors
- Phan, V. D., & Ahn, K. K.
- Affiliations
- University of Ulsan (KR)
- Corresponding author
- Ahn, Kyoung Kwan
- Venue
- Nonlinear Dynamics
- Published
- 2023-03-15
- Volume
- 111
- Issue
- 11
- Pages
- 10131-10146
- ISSN
- 0924-090X (ISSN-L)
- 1573-269X
- OpenAlex
- W4324353993
- Semantic Scholar
- f5c3203ec73fc85512d88817f5d530f30166d044
- Cited by
- 60
- References
- 38
- Citations by year
- 2026: 21 · 2025: 18 · 2024: 14 · 2023: 7
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nonlinear Dynamics (publishedVersion, cc-by)
- Funders
- National Research Foundation (2020R1A2B5B03001480)
- National Research Foundation of Korea (2021RIS-003)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Hydraulic and Pneumatic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Adaptive Control of Nonlinear Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- fault-tolerant control, electro-hydraulic servo system, fault detection and isolation, extended state observer, disturbance rejection, dynamic surface control, tracking control, explosion of complexity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault-tolerant control for an electro-hydraulic servo system with sensor fault compensation and disturbance rejection. https://app.cochat.ai/papers/10.1007/s11071-023-08364-3
- The paper
- Phan, V. D., & Ahn, K. K. (2023). Fault-tolerant control for an electro-hydraulic servo system with sensor fault compensation and disturbance rejection. Nonlinear Dynamics. https://doi.org/10.1007/s11071-023-08364-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.