Inertial measurements of upper limb motion
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We present an inertial sensor based monitoring system for measuring upper limb movements in real time. The purpose of this study is to develop a motion tracking device that can be integrated within a home-based rehabilitation system for stroke patients. Human upper limbs are represented by a kinematic chain in which there are four joint variables to be considered: three for the shoulder joint and one for the elbow joint. Kinematic models are built to estimate upper limb motion in 3-D, based on the inertial measurements of the wrist motion. An efficient simulated annealing optimisation method is proposed to reduce errors in estimates. Experimental results demonstrate the proposed system has less than 5% errors in most motion manners, compared to a standard motion tracker.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Flexible angular sensors are commonly used in rehabilitation and sports, but have not been disseminated at a large scale for studies of tremor [8,31,32].”
From Neurological Tremor: Sensors, Signal Processing and Emerging Applications (2010) · cites this paper as [32]
Citations
Cites
Optimization by Simulated Annealing
Kirkpatrick, S., Gelatt, C. D., & Vecchi, M. P. (1983) · Science · doi:10.1126/science.220.4598.671 · Cited by 45,134 · cited 1×
“The search of a global minima involves the comparison of the energies of two consecutive random conformations [6].”
BackgroundIntroduction to Robotics mechanics and Control
Craig, J. (1986) · Cited by 5,024
Billinger, S. A., Arena, R., Bernhardt, J., Eng, J. J., Franklin, B. A., Johnson, C. M., MacKay-Lyons, M., Macko, R. F., Mead, G. E., Roth, E. J., et al. (2014) · Stroke · doi:10.1161/str.0000000000000022 · Cited by 1,529
Introduction to robotics: Mechanics and control
Rodd, M. G. (1987) · Automatica · doi:10.1016/0005-1098(87)90105-1 · Cited by 1,505
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425 · cited 1×
“This releases the constraint of the classical robot-assisted systems, where robotic arms were physically attached with the upper limbs of the stroke patients in order to locate the latter in motion exercises [8].”
BackgroundReal-Time Inverse Kinematics Techniques for Anthropomorphic Limbs
Tolani, D., Goswami, A., & Badler, N. I. (2000) · Graphical Models · doi:10.1006/gmod.2000.0528 · Cited by 591 · cited 1×
“[11].”
Motion tracking: no silver bullet, but a respectable arsenal
Welch, G., & Foxlin, E. (2002) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2002.1046626 · Cited by 535 · cited 1×
“Successful examples have existed in literature for the applications of inertial sensor based systems in the measurements of upper limb movements [12, 14].”
BackgroundGordon, N. F., Gulanick, M., Costa, F., Fletcher, G., Franklin, B. A., Roth, E. J., & Shephard, T. (2004) · Circulation · doi:10.1161/01.cir.0000126280.65777.a4 · Cited by 505
A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package
Zhu, R., & Zhou, Z. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827825 · Cited by 390
Time resolved optical tomography of the human forearm
Hillman, E. M. C., Hebden, J. C., Schweiger, M., Dehghani, H., Schmidt, F. E. W., Delpy, D. T., & Arridge, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/315 · Cited by 146 · cited 1×
“Since upper limbs are frequently used to contact and manipulate objects [5], stroke recovery of functional use of upper limbs is a primary goal of rehabilitation.”
Background
Research works printed but not linked: 1
- Zhou H, Hu H (2005) Inertial motion tracking of human arm movements in home-based rehabilitation. In: Proceedings of IEEE international conference on mechatronics and automation, Niagara Falls, Ontario, Canada, pp 1306–1311
Cited by
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311
“In a future perspective, the integration of the protocol presented here with (1) the measure of wrist, elbow and shoulder position presented in [ 31 , 32], and (2) the functional indexes presented in [5], could result in an effective and comprehensive tool for the clinical assessment of patients with shoulder disorder…”
MethodShoulder and Elbow Joint Angle Tracking With Inertial Sensors
El-Gohary, M., & McNames, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208750 · Cited by 264
“orientations of wrist and elbow were estimated by fusion of the signals from MARG modules mounted on the wrist and elbow joints [19], [20].”
MethodI am a Smartwatch and I can Track my User's Arm
Shen, S., Wang, H., & Roy Choudhury, R. (2016) · Proceedings of the 14th Annual International Conference on Mobile Systems, Applications, and Services · doi:10.1145/2906388.2906407 · Cited by 184
“As a follow up to this work, the authors published a subsequent paper with multiple sensors on the arm to scale to a larger vocabulary of gestures [38, 39].”
BackgroundAn Open-Source and Wearable System for Measuring 3D Human Motion in Real-Time
Slade, P., Habib, A., Hicks, J. L., & Delp, S. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3103201 · Cited by 158
Neurological Tremor: Sensors, Signal Processing and Emerging Applications
Grimaldi, G., & Manto, M. (2010) · Sensors · doi:10.3390/s100201399 · Cited by 138
“Flexible angular sensors are commonly used in rehabilitation and sports, but have not been disseminated at a large scale for studies of tremor [8,31,32].”
BackgroundClosing the Gaps in Inertial Motion Tracking
Shen, S., Gowda, M., & Roy Choudhury, R. (2018) · Proceedings of the 24th Annual International Conference on Mobile Computing and Networking · doi:10.1145/3241539.3241582 · Cited by 123
“[14, 30–32] have proposed to track locations of IMUs attached to human limbs.”
BackgroundReducing Drifts in the Inertial Measurements of Wrist and Elbow Positions
Zhou, H., & Hu, H. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2025065 · Cited by 120
“To register the estimates of these two systems, we applied a static calibration method, as reported in [21].”
MethodSelf-citationAccuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Godwin, A., Agnew, M., & Stevenson, J. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000109 · Cited by 107
Pérez, R., Costa, Ú., Torrent, M., Solana, J., Opisso, E., Cáceres, C., Tormos, J. M., Medina, J., & Gómez, E. J. (2010) · Sensors · doi:10.3390/s101210733 · Cited by 97
Development of a real-time three-dimensional spinal motion measurement system for clinical practice
Goodvin, C., Park, E. J., Huang, K. I., & Sakaki, K. D. R. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0132-3 · Cited by 116
“The feasibility of estimating orientation with gyroscopes and accelerometers, specifically of the lower limb joints has been examined in previous research [16, 13, 18].”
BackgroundSchall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
“2006; Zhou, Hu, and Tao 2006; Bachmann, Yun, and Brumfield 2007; Wong and Wong 2008; Bergamini et al. 2014).”
BackgroundA method to qualitatively assess arm use in stroke survivors in the home environment
Leuenberger, K., Gonzenbach, R., Wachter, S., Luft, A., & Gassert, R. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1496-7 · Cited by 86
“In contrast to accelerometers only, inertial measurement units (IMUs) comprising accelerometers and gyroscopes (angular rate sensors) can be used to precisely measure and monitor movements of body segments and have been proposed for portable motion capture of gait [6, 13] or arm movements [35, 36].”
Bergmann, J. H., Mayagoitia, R. E., & Smith, I. C. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-3 · Cited by 88
“Zhou et al (2006) showed that inertial measurement units (IMUs) consisting of gyroscopes, accelerometers and magnetometers used to measure upper limb motion can accurately estimate arm position [12].”
BackgroundMotion capture sensing techniques used in human upper limb motion: a review
Yahya, M., Shah, J. A., Kadir, K. A., Yusof, Z. M., Khan, S., & Warsi, A. (2019) · Sensor Review · doi:10.1108/sr-10-2018-0270 · Cited by 82
A spot check for assessing static orientation consistency of inertial and magnetic sensing units
Picerno, P., Cereatti, A., & Cappozzo, A. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2010.12.006 · Cited by 90
Douphrate, D. I., Fethke, N. B., Nonnenmann, M. W., Rosecrance, J. C., & Reynolds, S. J. (2011) · Applied Ergonomics · doi:10.1016/j.apergo.2011.09.007 · Cited by 81
“Zhou et al. (2006) demonstrated that IMUs consisting of accelerometers, gyroscopes and magnetometers used to measure upper limb motion can accurately estimate arm position.”
BackgroundA Methodology for the Performance Evaluation of Inertial Measurement Units
Sessa, S., Zecca, M., Lin, Z., Bartolomeo, L. D., Ishii, H., & Takanishi, A. (2012) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-012-9772-8 · Cited by 68
“The size, the sensor bandwidth and range of WB-3 are compatible with the normal requirements of the human motion analysis both for the upper limbs [33],[34], and the lower limbs [35],[36] .”
BackgroundAncillao, A., Savastano, B., Galli, M., & Albertini, G. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.07.005 · Cited by 60
Inertial sensors for motion detection of human upper limbs
Zhou, H., & Hu, H. (2007) · Sensor Review · doi:10.1108/02602280710731713 · Cited by 56
“The main concern of our motion detection analysis is the orientation estimate that can be fed into the proposed kinematic model (Zhou et al., 2006c).”
BackgroundMethodInfluentialSelf-citationDevelopment of a real-time IMU-based motion capture system for gait rehabilitation
Kong, W., Sessa, S., Cosentino, S., Zecca, M., Saito, K., Wang, C., Imtiaz, U., Lin, Z., Bartolomeo, L. D., Ishii, H., et al. (2013) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2013.6739779 · Cited by 50
Pfau, T., Ferrari, M., Parsons, K. J., & Wilson, A. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.08.004 · Cited by 49
Redkar, S. (2017) · International Robotics & Automation Journal · doi:10.15406/iratj.2017.03.00080 · Cited by 46
“Series of tasks were performed on the subjects and results showed high correlation between estimates obtained from inertial and optical tracking system [60,61].”
MethodBirkfellner, W., Hummel, J. B., Wilson, E., & Cleary, K. (2008) · Springer eBooks · doi:10.1007/978-0-387-73858-1_2 · Cited by 52
Design of a Wearable Sensing System for Human Motion Monitoring in Physical Rehabilitation
González-Villanueva, L., Cagnoni, S., & Ascari, L. (2013) · Sensors · doi:10.3390/s130607735 · Cited by 50
Upper limb motion estimation from inertial measurements
Zhou, H., & Hu, H. (2007) · Research Portal (Queen's University Belfast) · Cited by 40
Self-citationAn interactive Internet-based system for tracking upper limb motion in home-based rehabilitation
Zhang, S., Hu, H., & Zhou, H. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0295-6 · Cited by 39
“Work in [15, 21] also show that the inertial sensor integrates the measurements from the accelerometers and gyroscopes, the sensor fusion strategy can successfully handle the drift problem.”
Self-citationAirContour: Building Contour-based Model for In-Air Writing Gesture Recognition
Yin, Y., Xie, L., Gu, T., Lu, Y., & Lu, S. (2019) · ACM Transactions on Sensor Networks · doi:10.1145/3343855 · Cited by 35
A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs.
Gil-Agudo, A. M., Reyes-Guzmán, A. D. L., Dimbwadyo-Terrer, I., Peñasco-Martín, B., Bernal-Sahún, A., López-Monteagudo, P., del‐Ama, A. J., & Pons, J. L. (2013) · 中国神经再生研究:英文版 · doi:10.3969/j.issn.1673-5374.2013.19.005 · Cited by 39
“Unlike previous studies [3, 8, 12] , nine degrees of freedom (two in the head, three in the shoulder, two in the elbow and two in the wrist) were involved in the use of the inertial measurement unit-based system for the analysis of head movements in this study.”
Designing inclusive interactions
Langdon, P., Clarkson, P. J., & Robinson, P. (2013) · Universal Access in the Information Society · doi:10.1007/s10209-013-0289-0 · Cited by 35
Comparing daily shoulder motion and frequency after anatomic and reverse shoulder arthroplasty
Langohr, G. D. G., Haverstock, J. P., Johnson, J. A., & Athwal, G. S. (2017) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2017.09.023 · Cited by 34
Posture estimation for a canine machine interface based training system
Brugarolas, R., Roberts, D. L., Sherman, B. L., & Bozkurt, A. Y. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346964 · Cited by 31
ViFin: Harness Passive Vibration to Continuous Micro Finger Writing with a Commodity Smartwatch
Chen, W., Chen, L., Ma, M., Parizi, F. S., Patel, S., & Stankovic, J. A. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3448119 · Cited by 30
“Zhou et al. [71] utilize a kinematic chain to track human upper limb motion by placing multiple devices on the arm.”
BackgroundJoint angle tracking with inertial sensors
El‐Gohary, M., Pearson, S., & McNames, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649344 · Cited by 31
ANFIS-based Sensor Fusion System of Sit- to- stand for Elderly People Assistive Device Protocols
Salah, O., Ramadan, A. A., Sessa, S., Ismail, A., Fujie, M. G., & Takanishi, A. (2013) · Machine Intelligence Research · doi:10.1007/s11633-013-0737-6 · Cited by 29
“That is quite different from [16], which uses two wearable inertial sensors with equality constrained optimization technique to find an optimal solution for the human arm tracking.”
BackgroundHuman Motion Analysis with Wearable Inertial Sensors
Chen, X. (2013) · Cited by 40
Li, H.-T., Huang, J.-J., Pan, C.-W., Chi, H.-I., & Pan, M. (2015) · Sensors · doi:10.3390/s150716196 · Cited by 29
Bravi, R., Caputo, S., Jayousi, S., Martinelli, A., Biotti, L., Nannini, I., Cohen, E. J., Quarta, E., Grasso, S., Lucchesi, G., et al. (2021) · Sensors · doi:10.3390/s21041057 · Cited by 28
Bending Angle Sensor Based on Double-Layer Capacitance Suitable for Human Joint
Goto, D., Sakaue, Y., Kobayashi, T., Kawamura, K., Okada, S., & Shiozawa, N. (2023) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2023.3289318 · Cited by 26
“However, depending on the experience and subjectivity of the therapist, SIAS and FMA-LE may not be used to quantitatively and objectively evaluate the joint functions of a stroke patient [6].”
BackgroundSynergistic control of forearm based on accelerometer data and artificial neural networks
Mijović, B., Popović, M. B., & Popović, D. B. (2008) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2008005000019 · Cited by 24
“To observe segment movements, micro-electro-mechanical systems-based accelerometers may be used (26-28); however, thus far, accelerometers were never used efficiently for the assessment of joint angles with sufficient precision in upper extremities.”
MethodCervical Spine Motion during Transfer and Stabilization Techniques
Shrier, I., Boissy, P., Lebel, K., Boulay, J., Segal, E., Delaney, J. S., Vacon, L. C., & Steele, R. J. (2014) · Prehospital Emergency Care · doi:10.3109/10903127.2014.936634 · Cited by 23
“IMUs are used in aerospace, marine and automotive fields and are now increasingly used for human motion tracking in several clinical applications.(29-43) We used IMUs from Xsens Technologies (XSens MTx, www.”
MethodMilliBack: Real-Time Plug-n-Play Millimeter Level Tracking Using Wireless Backscattering
Xiao, N., Yang, P., Li, X., Zhang, Y., Yan, Y., & Zhou, H. (2019) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3351270 · Cited by 23
“[12, 13, 61, 62] have proposed to track locations of IMUs attached to human limbs, but they attach multiple IMUs, one for each rigid-body component, essentially tracking the orientation (rather than location) of the IMUs.”
BackgroundSelf-citationThe reliability of side to side measurements of upper extremity activity levels in healthy subjects
Acuna, M., Amasay, T., & Karduna, A. R. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-168 · Cited by 27
“Other sensors have been developed that combine accelerometers, gyroscopes and magnetometers in order to collect three dimensional kinematics [1,21,48-50].”
BackgroundMethodDevelopment of a Wearable IMU System for Automatically Assessing Lifting Risk Factors
Lu, M., Barim, M. S., Feng, S., Hughes, G., Hayden, M. A., & Werren, D. M. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-49904-4_15 · Cited by 22
Closing the Loop Between Body Compensations and Upper Limb Prosthetic Movements: A Feasibility Study
Legrand, M. L., Jarrassé, N., de Montalivet, É., Richer, F., & Morel, G. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.3048251 · Cited by 19
“angle of the prosthetic joints obtained through the encoder and some anatomical data of the user, the current positions of the end-effector and the acromion in the user’s trunk frame can be derived [38], [39].”
A calibration process for tracking upper limb motion with inertial sensors
Yang, H., & Ye, J. (2011) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2011.5985732 · Cited by 16
“Thus, inertial tracking technology has currently attracted many interests [7,8,9].”
BackgroundDevelopment and testing of a stitched stretch sensor with the potential to measure human movement
Greenspan, B., Hall, M. L., Cao, H., & Lobo, M. A. (2018) · Journal of the Textile Institute · doi:10.1080/00405000.2018.1432189 · Cited by 15
“The sensors are rigid, can be difficult to integrate into clothing (Papi et al., 2015; Patel, Park, Bonato, Chan, & Rodgers, 2012; Zhou et al., 2006), and often result in uncomfortable user experience (Chan, Estève, Fourniols, Escriba, & Campo, 2012; Dunne, Ashdown, & Smyth, 2005).”
BackgroundPortaz, M., Corbí, A., Casas-Ortiz, A., & Santos, O. C. (2024) · User Modeling and User-Adapted Interaction · doi:10.1007/s11257-024-09393-2 · Cited by 16
“The complete MTS can be analysed, as Zhou et al. (2006) did for estimating the upper limb motion registered, although a time series feature extraction workflow (i.e. preprocessing, segmentation, feature extraction, dimensionality reduction and classification) is a more efficient and effective process…”
Studying upper-limb kinematics using inertial sensors: a cross-sectional study
Roldán‐Jiménez, C., & Vargas, A. I. C. (2015) · BMC Research Notes · doi:10.1186/s13104-015-1517-x · Cited by 13
“Focusing on stroke patients and their rehabilitation, inertial sensors have been included in a motion tracking device [34] as well as part of a hybrid tracking system integrating additionally vision for arm motion [35].”
MethodAbbasi, J., Salarieh, H., & Alasty, A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102290 · Cited by 12
AUTOMATIC CALIBRATION OF A MOTION CAPTURE SYSTEM BASED ON INERTIAL SENSORS FOR TELE-MANIPULATION
Hoffmann, J., Brüggemann, B., & Krüger, B. (2010) · International Conference on Informatics in Control, Automation and Robotics (ICINCO) · doi:10.5220/0002880301210128 · Cited by 11
“In this area applications like home rehabilitation systems (Zhou et al., 2006; Zhou and Hu, 2007; Tao et al., 2007) or robot controllers (Miller et al., 2004) have been developed.”
BackgroundMethodBiomechanical motion capture methods focused on tele-physiotherapy
Callejas-Cuervo, M., Ruiz-Olaya, A. F., & Salamanca, R. M. G. (2013) · Pan American Health Care Exchanges · doi:10.1109/pahce.2013.6568264 · Cited by 11
“En el trabajo presentado en [28], se describe un sistema inercial de seguimiento basado en la medición de los movimientos de las extremidades superiores en tiempo real.”
BackgroundNourollahi‐Darabad, M., Afshari, D., Dianat, I., & Jodakinia, L. (2020) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2020.103029 · Cited by 9
Sensing and Characterization of the Wrist Using Dart Thrower’s Movement
Nguyen, N. D., Pham, T. H., Pathirana, P. N., Babazadeh, S., Page, R. S., & Seneviratne, A. P. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2821243 · Cited by 8
“They can provide continuous monitoring over a long duration, and hence subjects or patients would be able to perform prescribed movement patterns not only in medical clinics but also in home-based environments [19].”
BackgroundFischer, G., Wirth, M. A., Balocco, S., & Calcagni, M. (2021) · Sensors · doi:10.3390/s21165623 · Cited by 8
Quantifying forearm and wrist joint power during unconstrained movements in healthy individuals
Flores, D., Laurendeau, S., Teasdale, N., & Simoneau, M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-157 · Cited by 8
“These sensors have been used to assess the efficiency of human movement such as upper arm reaching movements [3,4].”
MethodCoupled Human-machine Tele-manipulation
Brüggemann, B., Röhling, T., & Welle, J. (2015) · Procedia Manufacturing · doi:10.1016/j.promfg.2015.07.157 · Cited by 8
A measurement system for wrist movements in biomedical applications
Borbély, B. J., Tihanyi, A., & Szolgay, P. (2015) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2015.7300047 · Cited by 7
“As a main difference, inertial sensors give orientation information more accurately than position compared to marker-based methods, providing intersegmental angles of measured body parts [5]–[7].”
BackgroundKim, W., Beom, J., Park, C., Koh, S., Kim, Y. J., Kim, Y., Chung, S. G., & Kim, S. (2018) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-017-0315-4 · Cited by 7
Greenspan, B., & Lobo, M. A. (2020) · Multimodal Technologies and Interaction · doi:10.3390/mti4030045 · Cited by 7
Mixture Model Segmentation for Gait Recognition
Field, M., Stirling, D. A., Naghdy, F., & Pan, Z. S. (2008) · ECSIS Symposium on Learning and Adaptive Behaviors for Robotic Systems (LAB-RS) · doi:10.1109/lab-rs.2008.26 · Cited by 7
Human Leg Motion Tracking by Fusing IMUs and RGB Camera Data Using Extended Kalman FilterPreprint
Taheri, O., Salarieh, H., & Alasty, A. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2011.00574 · Cited by 7
“[14] to fuse IMU and Kinect data for human upper limb motion tracking.”
MethodZhou, Y., Cheng, Z., Jing, L., & Hasegawa, T. (2015) · Applied Intelligence · doi:10.1007/s10489-015-0649-y · Cited by 6
The effect of elbow joint centre displacement on force generation and neural excitation
Doheny, E. P., Lowery, M. M., O’Malley, M., & FitzPatrick, D. P. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0488-2 · Cited by 6
“The X and Y axes correspond to the anatomical anterior–posterior axis (aligned along the radioulnar link when the elbow is flexed to 90 ) and the proximal–distal axis (aligned along the humerus in this model), respectively, similar coordinate systems were used by [4] and [42].”
MethodWalking assessment in the phase space by using ultra-miniaturized Inertial Measurement Units
Sessa, S., Saito, K., Zecca, M., Bartolomeo, L. D., Lin, Z., Cosentino, S., Ishii, H., Ikai, T., & Takanishi, A. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6618035 · Cited by 6
“The size, the sensor bandwidth and range of WB-4R IMUs are compatible with the normal requirements of the human motion analysis both for the upper limbs [17],[18], and the lower limbs [19],[20].”
MethodSchall, M. C., Fethke, N., Thomas, G. W., Gerr, F., Wilder, D. G., & Pennathur, P. (2014) · doi:10.17077/etd.orlp9g1i · Cited by 9
“For example, gyroscopic drift may be compensated for by fusing accelerometer-based orientation information resulting from the constant acceleration of gravity (Bachman et al., 2007; Favre et al., 2006; Luinge and Veltink, 2004; Wong and Wong, 2008; Zhou et al., 2006; Zhu and Zhou, 2004).”
The Nightingale Prize for the best scientific paper published in MBEC 2006
Spaan, J. A. E. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0287-6 · Cited by 5
Joint Angle Tracking with Inertial Sensors
El‐Gohary, M. (2000) · doi:10.15760/etd.661 · Cited by 6
An Investigation into Stroke Patients’ Utilisation of Feedback from Computer-based Technology
Parker, J., Mountain, G. A., & Hammerton, J. (2010) · Springer eBooks · doi:10.1007/978-1-84996-166-0_16 · Cited by 4
“Advantageously, this feedback allows the patient and therapist to analyse and record the movements performed in the absence of a therapist ( Zhou et al., 2006 ).”
BackgroundAkintade, O. O., & Kehinde, L. O. (2017) · International Journal of Electronics and Electrical Engineering · doi:10.18178/ijeee.5.2.127-134 · Cited by 4
“Reference [5] integrated data from both accelerometer and gyroscope for better angle estimates of the shoulder and elbow joints.”
MethodReal-time measurement of radiocarpal joint angle during dart-thrower's movement
Nguyen, N. D., Pham, T. H., Pathirana, P. N., Babazadeh, S., & Page, R. S. (2015) · Biomedical Engineering International Conference · doi:10.1109/bmeicon.2015.7399543 · Cited by 3
Validation of custom wearable sensors to measure angle kinematics: A technical report
Walmsley, C. P., Xu, W., Ortega-Sánchez, C., Campbell, A., Imms, C., Elliott, C. M., & Williams, S. A. (2019) · Health and Technology · doi:10.1007/s12553-019-00360-1 · Cited by 3
Use of motion trackers for equine locomotion analysis to implement a horse simulator
Mager-Maury, S., Biau, S., & Deslandes, S. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.713609 · Cited by 3
“Many studies requiring accelerometer sensors were conducted for both human activities (Scapelllato et al. 2005; Zhou et al. 2006) and riders (Biau et al. 2002; Biau and Barrey 2004; Pfau et al. 2005).”
BackgroundGodwin, A. A. (2009) · QSpace (Queen's University Library) · Cited by 3
Hasan, D. S., & Hamarash, I. I. (2017) · Journal of Applied and Physical Sciences · doi:10.20474/japs-3.2.3 · Cited by 3
wearable sensors systems for human motion analysis: sports and rehabilitation
Silva, A. S. M. (2014) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/6jzw-2n88 · Cited by 12
Baklouti, S., Rezgui, T., Chaker, A., Sahbani, A., & Bennour, S. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.10003 · Cited by 2
Remote Sensing Technologies for Indoor Applications
Won, S.-H. P., Melek, W., & Golnaraghi, F. (2011) · Wiley eBooks · doi:10.1002/9781118104750.ch20 · Cited by 2
Balance analysis of one leg stance for older adults with Inertial Measurement Units
Kong, W., Sessa, S., Magistro, D., Zhang, D., Imtiaz, U., Cosentino, S., Zecca, M., Ishii, H., Takeuchi, H., Kawashima, R., et al. (2014) · IEEE Healthcare Innovation Conference (HIC) · doi:10.1109/hic.2014.7038936 · Cited by 2
Tajdinan, S., Afshari, D., Mohammadi, A., & Tabesh, H. (2014) · Cited by 2
Effects of wrist kinematic coupling movements during dart-thrower's motion
Nguyen, N. D., Pham, T. H., Mahani, T., Pathirana, P. N., Babazadeh, S., Ling, F., & Page, R. M. (2016) · International Conference on Wireless Networks and Embedded Systems (WECON) · doi:10.1109/wecon.2016.7993486 · Cited by 2
“The availability of such equipment that could be used in non-clinical settings which can provide a continuous monitoring in long duration when a trial subject performs prescribed movement patterns regardless in medical clinics or home-base environment [16], [17].”
BackgroundRestricted dart throwing movement for the assessment of wrist functionality
Nguyen, N. D., Pham, T. H., Pathirana, P. N., Babazadeh, S., Ling, F., Page, R. S., & Seneviratne, A. P. (2017) · Biomedical Engineering International Conference · doi:10.1109/bmeicon.2017.8229167 · Cited by 2
“Hence, healthy subjects or patients could have more beneficial and convenient when performing prescribed movement patterns regardless in medical clinics or home based environment [16], [17].”
BackgroundExploring Energy Efficiency of Hardware-Architectures for IMU Based Orientation Estimation
Brückner, H.-P., Spindeldreier, C., & Blume, H. (2014) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-10948-0_8 · Cited by 2
Neuromotor Evaluation of the Upper Limb During Activities of Daily Living: A Pilot Study
Santos, P., Quaresma, C., Garcia, I., & Quintão, C. (2022) · IFIP advances in information and communication technology · doi:10.1007/978-3-031-07520-9_11 · Cited by 2
Ergonomic Portable Measuring System Designed to Assist Patients with Metacarpal Injuries
Marrugo, D. A., Romero-Mercado, C. D., Mendoza-Vanegas, K., Magre, L. A., & Ríos, Y. Y. (2020) · International Congress of Engineering Mechatronics and Automation (CIIMA) · doi:10.1109/ciima50553.2020.9290299 · Cited by 1
“An interesting solution is proposed by Zhou [11], this consists of a portable motion tracking system.”
MethodActive Vision for Tremor Disease Monitoring
Halawani, A., Réhman, S. U., & Li, H. (2015) · Procedia Manufacturing · doi:10.1016/j.promfg.2015.07.252 · Cited by 1
“Inertial measurement units (IMUs)were also used [4,5].”
Birkfellner, W., Hummel, J. B., Wilson, E., & Cleary, K. (2008) · Cited by 2
Langohr, G. D. G. (2015) · Scholarship@Western (Western University) · Cited by 1
Development of a Bilateral Assistance and Coordination Rehabilitation Training System
Guo, S., & Song, Z. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-559-9.ch036 · Cited by 1
A study on the impact of cement type and heat stimulation on performance of superplasticizers
Tahery, Z., & Date, S. (2017) · Journal of Applied and Physical Sciences · doi:10.20474/japs-3.2.4 · Cited by 1
Empirical modelling of human gaits for bipedal robots
Field, M., Stirling, D. A., Naghdy, F., & Pan, Z. S. (2007) · Research Online (University of Wollongong) · Cited by 1
Pérez‐Rodríguez, R. (2012) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.14737 · Cited by 5
Intelligent Fastening Tool Tracking Systems Using Hybrid Remote Sensing Technologies
Won, P. (2010) · UWSpace (University of Waterloo) · Cited by 1
Short-Term Tracking of Orientation with Inertial Sensors
Sedaghat, G. (2000) · doi:10.15760/etd.6351 · Cited by 1
Optimization of passive cantilever-type tuned mass damper to reduce the hand postural tremor
Gebai, S. (2020) · theses.fr (ABES) · doi:10.70675/994e0848ze136z4e48z8db8z9981215dcb5b · Cited by 6
Annegarn, J. (2012) · Research Publications (Maastricht University) · doi:10.26481/dis.20121107ja
Halawani, A., Réhman, S. U., & Li, H. (2015)
Ambulatory Fall Event Detection with Integrative Ambulatory Measurement (IAM) Framework
Liu, J. (2008) · VTechWorks (Virginia Tech)
Estudio de la cinemática del miembro superior e inferior mediante sensores inerciales.
Jiménez, C. R. (2017) · Repositorio Institucional de la Universidad de Málaga (University of Málaga) · Cited by 4
Garnett, R. F., Davis, G. A., Sesek, R. F., Gallagher, S., Schall, M. C., & Chen, H. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-94619-1_14
Metadata
- Authors
- Zhou, H., Hu, H., & Tao, Y.
- Affiliations
- University of Essex (GB)
- Corresponding author
- Zhou, Huiyu
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2006-05-31
- Volume
- 44
- Issue
- 6
- Pages
- 479-487
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2126821206
- Semantic Scholar
- cb31b9bd56f513195312fc65e8a835c3f875937b
- Cited by
- 106
- References
- 15
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 10 · 2019: 6 · 2018: 5 · 2017: 7 · 2016: 4 · 2015: 9 · 2014: 7 · 2013: 8 · 2012: 6
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Research Portal (Queen's University Belfast) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (GR/S29089/01)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Keywords
- inertial sensors, stroke rehabilitation, home-based rehabilitation, kinematic modeling, wrist kinematics, shoulder joint, elbow, simulated annealing, 3D motion estimation, real-time motion monitoring
- MeSH terms
- Stroke Rehabilitation, Biomechanical Phenomena, Elbow Joint, Equipment Design, Humans, Male, Models, Biological, Motion, Wrist Joint, Range of Motion, Articular, Stroke, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.