First in vivo assessment of “Outwalk”: a novel protocol for clinical gait analysis based on inertial and magnetic sensors
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
A protocol named “Outwalk” was recently proposed to measure the thorax–pelvis and lower-limb kinematics during gait in free-living conditions, by means of an inertial and magnetic measurement system (IMMS). The aim of this study was to validate Outwalk on four healthy subjects when it is used in combination with a specific IMMS (Xsens Technologies, NL), against a reference protocol (CAST) and measurement system (optoelectronic system; Vicon, Oxford Metrics Group, UK). For this purpose, we developed an original approach based on three tests, which allowed to separately investigate: (1) the consequences on joint kinematics of the differences between protocols (Outwalk vs. CAST), (2) the accuracy of the hardware (Xsens vs. Vicon), and (3) the summation of protocols’ differences and hardware accuracy (Outwalk + Xsens vs. CAST + Vicon). In order to assess joint-angles similarity, the coefficient of multiple correlation (CMC) was used. For test 3, the CMC showed that Outwalk + Xsens and CAST + Vicon kinematics can be interchanged, offset included, for hip, knee and ankle flexion–extension, and hip ab-adduction (CMC > 0.88). The other joint-angles can be interchanged offset excluded (CMC > 0.85). Tests 1 and 2 also showed that differences in offset between joint-angles were predominantly induced by differences in the protocols; differences in correlation by both hardware and protocols; differences in range of motion by the Xsens accuracy. Results thus support the commencement of a clinical trial of Outwalk on transtibial amputees.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242 · cited 1×
“Since IMMSs do not provide any information about the position of the SUs, Outwalk does not define the anatomical/functional CSs based on the identification of single anatomical landmarks, as done in most of the protocols for clinical gait analysis [8, 23].”
BackgroundA gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677 · cited 3×
“(2) its performances are widely tested and documented [1, 2, 8]; (3) it was the reference protocol used in [17]; (4) it requires the use of clusters of markers, which can be thought as SU, and the definition of technical frames, which are analog to the local CS of a SU.”
MethodRepeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070611 · Cited by 1,476 · cited 4×
“Taken into account that each O(t) must be compared only with its synchronous C(t), we developed a new formula for the CMC, which is a variation of the Kadaba within-day CMC [11], and removes all other sources of gait-cycle-to-gait-cycle variability.”
MethodInfluentialAccelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617 · cited 1×
“tings, in a continuous modality, for long periods; therefore, they might allowed to collect a great number of consecutive gait cycles during spontaneous walking in daily life environments [12].”
BackgroundRobot sensor calibration: solving AX=XB on the Euclidean group
Park, F. C., & Martin, B. J. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.326576 · Cited by 570 · cited 1×
“Through a hand-eye calibration [3, 15], the local CS of each cluster was defined in such a way that its axes were overlapped with those of the CS of the SU in static conditions.”
MethodGait patterns in spastic hemiplegia in children and young adults
(1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769030-00016 · Cited by 524 · cited 1×
“classification [22] and diplegic belonging to the II–IV of the Ferrari et al.”
BackgroundA new method for estimating joint parameters from motion data
Schwartz, M. H., & Rozumalski, A. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.009 · Cited by 512 · cited 1×
“Since a non-invasive gold-standard for the lower limb kinematics is missing [ 20 ], we compared the new protocol (Outwalk) based on the new system (IMMS) with respect to a reference protocol (CAST; [1, 2]) and system (optoelectronic).”
MethodA new anatomically based protocol for gait analysis in children
Leardini, A., Sawacha, Z., Paolini, G., Ingrosso, S., Nativo, R., & Benedetti, M. G. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.12.018 · Cited by 491 · cited 1×
“1a, 3a: to which extent Outwalk and CAST kinematics can be interchanged; 1b, 3b: if Outwalk and CAST kinematics are as similar as the kinematics measured by CAST and other four popular protocols for clinical gait analysis, namely Total3DGait (Total3Dg) [13], Plug-in Gait (PiG) [5], SAFLo [9], and LAMB [18], using [8]…”
MethodQuantitative comparison of five current protocols in gait analysis
Ferrari, A., Benedetti, M. G., Pavan, E., Frigo, C., Bettinelli, D., Rabuffetti, M., Crenna, P., & Leardini, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.11.009 · Cited by 334 · cited 10×
“• y(t)P is a waveform obtained by appending one after the other the waveforms of all the trials performed by AF (4 in [8]), obtained applying the protocol P (with P = CAST, Total3Dg, PiG, SAFLo, and LAMB) for the specific joint-angle; • M(t), m(t) indicate the maximum and minimum values of y(t)P among the five protoco…”
BackgroundMethodResultInfluentialSelf-citation
Cited by
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329
“[12] reported excellent CMC values between 0.”
BackgroundMethodResultInfluentialConcurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318
“CMC is reported only for joints and planes where all values are real numbers [10].”
InfluentialWearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263
Picerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237
Role of Body-Worn Movement Monitor Technology for Balance and Gait Rehabilitation
Horak, F., King, L., & Mancini, M. (2015) · Physical Therapy · doi:10.2522/ptj.20140253 · Cited by 227
‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0545-x · Cited by 218
“As this was used in [12] for the validation of Outwalk, herein we will only explicitly refer to this IMMS.”
MethodSelf-citationBenjaminse, A., Gokeler, A., Dowling, A. V., Faigenbaum, A., Ford, K. R., Hewett, T. E., Onate, J. A., Otten, B., & Myer, G. D. (2015) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2015.4986 · Cited by 182
Palermo, E., Rossi, S., Marini, F., Patanè, F., & Cappa, P. (2014) · Measurement · doi:10.1016/j.measurement.2014.03.004 · Cited by 182
“The values of r were interpreted as follows [31]:”
MethodMundt, M., Koeppe, A., David, S., Witter, T., Bamer, F., Potthast, W., & Markert, B. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00041 · Cited by 165
“Several approaches have been suggested to overcome this problem: calibration postures or movements (Favre et al., 2009; Ferrari et al., 2010; Palermo et al., 2014), anatomical calibrations (Picerno et al., 2008; Bisi et al., 2015), post-trial calibration procedures (Hamacher et al., 2014; Li and…”
MethodBlair, S., Duthie, G., Robertson, S., Hopkins, W., & Ball, K. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.031 · Cited by 117
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
Cereatti, A., Gurchiek, R., Mündermann, A., Fantozzi, S., Horak, F., Delp, S., & Aminian, K. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112225 · Cited by 79
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65
“were used to interpret the agreement between the curves [19]:”
de Ruiter, C. J., Wilmes, E., Brouwers, S. A. J., Jagers, E. C., & van Dieën, J. H. (2024) · Sports Biomechanics · doi:10.1080/14763141.2022.2056076 · Cited by 22
“RMSEs are presented in Table 1A which also shows that CMC values were excellent (Ferrari, Cutti, Garofalo et al., 2010) for the angles and angular velocities of the thigh and the shank.”
InfluentialReliability and validity of instrumented soccer equipment
Akins, J. S., Heebner, N. R., Lovalekar, M., & Sell, T. C. (2015) · Journal of Applied Biomechanics · doi:10.1123/jab.2014-0191 · Cited by 17
Metadata
- Authors
- Ferrari, A., Cutti, A. G., Garofalo, P., Raggi, M., Heijboer, M., Cappello, A., & Davalli, A.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2009-11-13
- Volume
- 48
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W1982405225
- Cited by
- 181
- References
- 22
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.