Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study
Open accessPublished version of a preprint
Abstract
BACKGROUND: Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings including more recently in medical applications. The use of real-time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured, including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady-state aerobic exercise. OBJECTIVE: The objective of this study was to validate the accuracy of both HR and EE for 2 common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. METHODS: ; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using an HR chest strap (Polar) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. RESULTS: Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (RE, %) of -3.3% (SD 16.7), whereas Fitbit estimated HR with an RE of -4.7% (SD 19.6) across all activities. The highest error was observed during high-intensity intervals on bike (Fitbit: -11.4% [SD 35.7]; Garmin: -14.3% [SD 20.5]) and lowest error during high-intensity intervals on treadmill (Fitbit: -1.7% [SD 11.5]; Garmin: -0.5% [SD 9.4]). Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: -19.3% [SD 28.9], Garmin: -1.6% [SD 30.6], P<.001) across all activities, and with both correlating poorly with indirect calorimetry measures. CONCLUSIONS: Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.
AI snapshot
Written from the paper’s full text.
TL;DR
In 20 healthy adults, Fitbit Charge 2 and Garmin vívosmart HR+ showed reasonable heart rate (HR) accuracy with a small negative bias, but accuracy worsened during high-intensity activities, cycling, and when Garmin’s activity mode was not indicated. Energy expenditure (EE) estimates were less accurate, especially for Fitbit during cycling activities.
Key findings
- HR across all activities: Garmin mean relative error (RE) −3.3% (SD 16.7); Fitbit −4.7% (SD 19.6). Garmin without activity mode was worse: −5.47% (SD 22.79; P<.001 vs activity mode indicated). MAPE was 10.79% (SD 13.14) for Garmin and 11.33% (SD 16.71) for Fitbit.
- Highest HR error occurred during high-intensity intervals on bike: Fitbit −11.4% (SD 35.7), Garmin −14.3% (SD 20.5); lowest during high-intensity intervals on treadmill: Fitbit −1.7% (SD 11.5), Garmin −0.5% (SD 9.4). Activities with repetitive upper-torso motion had lower error (−1.6%, SD 9.6) than those without (−12.25%, SD 19.3; P<.001).
- EE estimates differed significantly: Fitbit −19.3% (SD 28.9) vs Garmin −1.6% (SD 30.6; P<.001), and both correlated poorly with indirect calorimetry. MAPE was 27.0% (SD 21.8) for Garmin and 25.1% (SD 17.3) for Fitbit. Highest EE error was Fitbit during MAX-C (−39.1%, SD 30.6) and HIIT-C (−41.9%, SD 31.3); Garmin had positive bias during resistance exercise (+21.0%, SD 35.7).
- Both devices produced spurious HR measurements when not worn on the wrist, confirmed by a bench-top nutator experiment at 22 rpm.
Methods
- Twenty healthy adults (11 females; mean age 27.5 [SD 6.0] years; mean BMI 22.5 [SD 2.3] kg/m²; 10 at OHSU, 10 at York University) completed two laboratory visits 24 hours apart. Activities included maximal oxygen uptake tests on treadmill or cycle ergometer, free-weight resistance circuit, activities of daily living, and high-intensity interval training on treadmill or cycle ergometer.
- Fitbit Charge 2 and Garmin vívosmart HR+ were tested simultaneously on randomized/counterbalanced wrists. HR criterion was Polar H7 chest strap; EE criterion was portable indirect calorimetry (Cosmed K4b2 or K5). Garmin was tested with and without activity mode indicated.
- Analysis used Bland-Altman, Pearson correlation, mean relative error, mean absolute percent error, paired t tests, one-way ANOVA with Tukey post hoc, and concordance class correlation in R and GraphPad Prism.
Limitations
- Stated: only two consumer-grade devices were tested; skin color was not accounted for, and future studies should report Fitzpatrick skin tone; exercise was conducted in a laboratory rather than real-world setting; HR was not compared against a true gold standard such as ECG.
- Evident from the text: Fitbit data could not be exported reliably without the exercise type selected, preventing a no-button comparison for Fitbit; Garmin EE data could only be compared at low resolution as an average across each activity; proprietary algorithms can change without warning, limiting integration into medical systems.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
17 of 38 cited sources checked · 7 supported · 0 flagged · accuracy not yet measured
- Findingown data
The two devices showed reasonable accuracy in HR and EE estimations under certain exercise conditions.
“Similar to previous studies [13,28,30-32], we found reasonable accuracy in HR and EE estimations for these 2 devices under certain exercise conditions.”
Quote in the paperSubstantial claim5 of 5 sources checked- cites [13] source
The Results (Laboratory validation; page unavailable) report activity-specific energy-expenditure errors for the Apple Watch and Fitbit Charge HR, supporting reasonable EE accuracy under some exercise conditions. The Methods (Statistical analysis; page unavailable) compare device EE estimates with criterion EE measurements, but our copy does not report a validation of the devices’ HR-estimation accuracy. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [28] source
The Results and Discussion (Abstract; page unavailable) report that wrist-worn monitors’ HR accuracy varied with exercise intensity and was generally best at rest, supporting only the qualified HR portion. The study assessed four monitors, not the citing authors’ two devices, and our copy reports no evaluation of energy-expenditure (EE) accuracy. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [30] source
The Discussion’s Principal Findings (page unavailable) describe reasonably accurate heart-rate readings for the Fitbit Charge HR under some conditions and accurate readings for the Garmin Forerunner 225 during vigorous activity. But the same section says energy-expenditure measurements were not accurate; the Results’ Energy Expenditure Overview reports an overestimation bias even where Fitbit estimates did not differ significantly from the criterion. The source studied three devices, so it cannot establish accuracy for the citing sentence’s unspecified ‘2 devices.’ (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [31] source
The Discussion reports that six monitors measured heart rate comparably to the criterion measure during resting, walking, and running. The Methods describe heart-rate readings and analyses, but the paper does not assess the accuracy of energy-expenditure (EE) estimates. Its introductory mention of EE does not establish that part of the claim. (LLM, conf=0.90)
Experimental — accuracy not yet measured - cites [32] source
The Discussion reports satisfactory heart-rate monitoring during exercise, with estimates within 1–9% of reference measurements. But the Results report larger energy-expenditure errors (9–43%), and the Discussion identifies inaccurate energy-expenditure estimation as a limitation. The paper tested four devices, not the citing sentence’s unspecified two, so it does not establish reasonable accuracy for both measures in those two devices under particular exercise conditions. (LLM, conf=0.87)
Experimental — accuracy not yet measured
- Findingown data
Considerable energy expenditure error was noted for resistance activities for Garmin.
“but considerable error was noted for some of the activities, particularly with cycling activities for Fitbit and resistance activities for Garmin.”
Quote in the paperNot a substantial claim- Rests on an assumption: The selected activities of daily living and structured exercises represent common daily physical activities and types of structured exercise relevant to users of wrist-worn activity monitors.
- Findingown data
Overall heart rate performance was significantly worse when activity mode was not indicated on the Garmin device compared with when activity mode was indicated (P<.001).
“The overall performance was significantly worse if the activity mode was not indicated on the Garmin device compared with when activity mode was indicated (P<.001).”
Quote in the paperSubstantial claim - Findingown data
For resistance exercise, error was higher on the left hand versus the right hand (15.0% vs 13.5%, P<.001).
“whereas the error was higher on the left hand versus the right hand for resistance (15.0% vs 13.5%, P<.001) and MAX-C (9.53 vs 2.97%, P<.001).”
Quote in the paperNot a substantial claim - Findingown data
When the activity mode is not initiated, the Garmin no-button trace appears shifted in time relative to the Polar.
“Both panels show that when the activity mode is not initiated on the wearable, there is less accuracy and also a distinct phase shift whereby the Garmin with no button trace appears to be shifted in time relative to the Polar.”
Quote in the paperNot a substantial claim
- Findingown data
For MAX-T, error was higher on the right hand versus the left hand (6.6% vs 5.1%, P<.001).
“the error was shown to be higher on the right hand versus the left hand for the MAX-T (6.6% vs 5.1%, P<.001), HIIT-T (6.72% vs 5.85%, P=.002), and ADLs (13.33% vs 11.17%, P<.001)”
Quote in the paperNot a substantial claim - Findingown data
The wearable devices tended to have significantly higher error when the heart rate signal transitioned quickly and at higher intensity.
“However, the wearable devices tended to have significantly higher error when the HR signal transitioned quickly and at higher intensity.”
Quote in the paperSubstantial claim - Findingown data
There was no difference in heart rate accuracy between the two devices when the activity mode was indicated.
“There was no difference in accuracy between the 2 devices when the activity mode was indicated.”
Quote in the paperSubstantial claim - Findingown data
Considerable energy expenditure error was noted for cycling activities for Fitbit.
“but considerable error was noted for some of the activities, particularly with cycling activities for Fitbit and resistance activities for Garmin.”
Quote in the paperSubstantial claim- Rests on an assumption: The selected activities of daily living and structured exercises represent common daily physical activities and types of structured exercise relevant to users of wrist-worn activity monitors.
- Findingown data
For MAX-C, error was higher on the left hand versus the right hand (9.53% vs 2.97%, P<.001).
“whereas the error was higher on the left hand versus the right hand for resistance (15.0% vs 13.5%, P<.001) and MAX-C (9.53 vs 2.97%, P<.001).”
Quote in the paperNot a substantial claim - Findingown data
Garmin heart rate error during high-intensity intervals on bike was −14.3% (SD 20.5).
“The highest error was observed during high-intensity intervals on bike (Fitbit: −11.4% [SD 35.7]; Garmin: −14.3% [SD 20.5])”
Quote in the paperNot a substantial claim - Findingown data
The relative error across collapsed data for activities with repetitive motion of the upper torso was significantly lower at −1.6% (SD 9.6) compared with activities with no repetitive motion of the upper torso at −12.25% (SD 19.3; P<.001).
“The relative error across the collapsed data for the activities with repetitive motion of the upper torso (ie, treadmill tests) was observed to be significantly lower at −1.6% (SD 9.6) when compared with activities with no repetitive motion of the upper torso (ie, cycle ergometer tests) at −12.25% (SD 19.3; P<.001).”
Quote in the paperSubstantial claim - Findingown data
Garmin energy expenditure mean relative error across all activities was −1.6% (SD 30.6).
“Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: −19.3% [SD 28.9], Garmin: −1.6% [SD 30.6], P<.001) across all activities”
Quote in the paperSubstantial claim - Findingown data
The time shift was a minor contributor to the inaccuracy within the high-intensity interval training activities.
“This shift in time is a minor contributor to the inaccuracy within the HIIT activities.”
Quote in the paperNot a substantial claim - Findingown data
Fitbit heart rate error during high-intensity intervals on treadmill was −1.7% (SD 11.5).
“lowest error during high-intensity intervals on treadmill (Fitbit: −1.7% [SD 11.5]; Garmin: −0.5% [SD 9.4])”
Quote in the paperNot a substantial claim - Findingown data
Garmin had significantly less negative energy expenditure bias than Fitbit across all activities (P<.001).
“Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: −19.3% [SD 28.9], Garmin: −1.6% [SD 30.6], P<.001) across all activities”
Quote in the paperSubstantial claim - Findingown data
Garmin heart rate error during high-intensity intervals on treadmill was −0.5% (SD 9.4).
“lowest error during high-intensity intervals on treadmill (Fitbit: −1.7% [SD 11.5]; Garmin: −0.5% [SD 9.4])”
Quote in the paperNot a substantial claim - Findingown data
More heart rate error was observed during high-intensity activities when there was a lack of repetitive wrist motion.
“There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used.”
Quote in the paperSubstantial claim - Findingown data
The correlation between heart rate values on the wearables and the gold standard chest band sensor was best during MAX-T (Fitbit: 0.94, Garmin: 0.94).
“The correlation between the HR values on the wearables and our gold standard chest band sensor was best during MAX-T (Fitbit: 0.94, Garmin: 0.94)”
Quote in the paperNot a substantial claim - Findingown data
Garmin heart rate mean absolute percent error was 10.79% (SD 13.14).
“MAPE (SD) for the Garmin and Fitbit was 10.79 % (13.14) and 11.33% (16.71), respectively.”
Quote in the paperSubstantial claim - Findingown data
When the activity mode of the wearables was activated, median percent relative errors were within the 5% error threshold for both devices.
“When the activity mode of the wearables are activated (panels A and B), median % relative errors are within the 5% error threshold for both devices.”
Quote in the paperSubstantial claim - Findingown data
Both Fitbit and Garmin performed reasonably well in estimating task-specific energy expenditure when looking at the group as a whole.
“Both Fitbit and Garmin performed reasonably well in estimating task-specific EE, when looking at the group as a whole”
Quote in the paperSubstantial claim- Rests on an assumption: The selected activities of daily living and structured exercises represent common daily physical activities and types of structured exercise relevant to users of wrist-worn activity monitors.
- Rests on an assumption: The 20 healthy adults studied are representative of the broader population of wrist-worn activity monitor users.
- Findingown data
There was a generally small but significant impact of the wrist side worn on the percent absolute relative error.
“There was a generally small but significant impact of the wrist side worn (ie, left vs right) on the percent absolute relative error.”
Quote in the paperNot a substantial claim - Findingown data
Bland-Altman plots indicated that all three devices underestimated heart rate compared with the reference standard.
“Bland-Altman plots indicated that all 3 devices underestimated the HR when compared with the reference standard”
Quote in the paperSubstantial claim - Findingnone given
The variability between the devices was comparable.
“The variability between these devices was comparable.”
Quote in the paperNot a substantial claim - Findingown data
When the activity mode was not activated, the median percent relative error significantly exceeded the 5% threshold across many activities.
“When the activity mode is not activated, as observed in panel C, the median % relative error significantly exceeds the 5% threshold across many of the activities.”
Quote in the paperSubstantial claim - Findingown data
Both Fitbit and Garmin energy expenditure estimates correlated poorly with indirect calorimetry measures.
“with both correlating poorly with indirect calorimetry measures.”
Quote in the paperSubstantial claim - Findingown data
Fitbit heart rate error during high-intensity intervals on bike was −11.4% (SD 35.7).
“The highest error was observed during high-intensity intervals on bike (Fitbit: −11.4% [SD 35.7]; Garmin: −14.3% [SD 20.5])”
Quote in the paperSubstantial claim - Findingown data
Poor correlation between heart rate values was observed during HIIT-C (Fitbit: 0.46, Garmin: 0.71).
“whereas poor correlation between the HR values was observed during the HIIT-C (Fitbit: 0.46, Garmin: 0.71).”
Quote in the paperSubstantial claim - Findingown data
Fitbit estimated heart rate with a mean relative error of −4.7% (SD 19.6) across all activities.
“Fitbit estimated HR with an RE of −4.7% (SD 19.6) across all activities.”
Quote in the paperSubstantial claim - Findingown data
When the activity mode is not initiated on the wearable, there is less heart rate accuracy.
“Both panels show that when the activity mode is not initiated on the wearable, there is less accuracy and also a distinct phase shift whereby the Garmin with no button trace appears to be shifted in time relative to the Polar.”
Quote in the paperSubstantial claim - Findingown data
Fitbit energy expenditure mean relative error across all activities was −19.3% (SD 28.9).
“Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: −19.3% [SD 28.9], Garmin: −1.6% [SD 30.6], P<.001) across all activities”
Quote in the paperSubstantial claim - Findingown data
Garmin estimated heart rate with a mean relative error of −3.3% (SD 16.7) across all activities.
“The Garmin estimated HR with a mean relative error (RE, %) of −3.3% (SD 16.7)”
Quote in the paperSubstantial claim - Findingown data
Fitbit heart rate mean absolute percent error was 11.33% (SD 16.71).
“MAPE (SD) for the Garmin and Fitbit was 10.79 % (13.14) and 11.33% (16.71), respectively.”
Quote in the paperSubstantial claim - Findingown data
For HIIT-T, error was higher on the right hand versus the left hand (6.72% vs 5.85%, P=.002).
“the error was shown to be higher on the right hand versus the left hand for the MAX-T (6.6% vs 5.1%, P<.001), HIIT-T (6.72% vs 5.85%, P=.002), and ADLs (13.33% vs 11.17%, P<.001)”
Quote in the paperNot a substantial claim - Findingown data
For ADLs, error was higher on the right hand versus the left hand (13.33% vs 11.17%, P<.001).
“the error was shown to be higher on the right hand versus the left hand for the MAX-T (6.6% vs 5.1%, P<.001), HIIT-T (6.72% vs 5.85%, P=.002), and ADLs (13.33% vs 11.17%, P<.001)”
Quote in the paperNot a substantial claim - Findingown data
For activities performed on the cycle ergometer, Fitbit had significantly higher mean error than Garmin.
“For activities performed on the cycle ergometer, both devices displayed negative bias, but there was significantly higher mean error for Fitbit compared with Garmin (Fitbit: −40.5% [SD 30.2], Garmin: −7.9% [SD 27.6]; P<.001).”
Quote in the paperSubstantial claim - Findingown data
Both Fitbit and Garmin demonstrated negative bias when activities were performed on the treadmill.
“Both Fitbit and Garmin demonstrated negative bias when activities were performed on the treadmill (Fitbit: −15.1% [SD 13.5], Garmin: −7.4% [SD 30.1]; P=.18).”
Quote in the paperNot a substantial claim - Findingown data
Garmin was significantly more accurate than Fitbit at estimating EE during all cycle ergometer activities.
“Garmin was significantly more accurate than Fitbit at estimating EE during MAX (Fitbit: 31.5% [SD 21.5], Garmin: 22.9% [SD 16.8]; P=.047) and all cycle ergometer activities (Fitbit: 42.7% [SD 26.8], Garmin: 22.8% [SD 16.6]; P=.03).”
Quote in the paperSubstantial claim - Findingown data
For Fitbit, the highest error in measuring EE was observed during MAX-C (−39.1% [SD 30.6]) and HIIT-C (−41.9% [SD 31.3]).
“The highest error was observed during MAX-C (−39.1% [SD 30.6]) and HIIT-C (−41.9% [SD 31.3]) for Fitbit and resistance (21.0% [SD 35.7]) for Garmin.”
Quote in the paperNot a substantial claim - Findingcitation
HR and EE measured by both the Garmin and Fitbit devices during the resistance exercise were similar to the measurements reported by Boudreaux et al.
“In results presented in this paper, HR and EE measured by both the Garmin and Fitbit devices during the resistance exercise were similar to the measurements reported by Boudreaux et al [24].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [24] source
- Findingown data
For activities performed on the cycle ergometer, both devices displayed negative bias.
“For activities performed on the cycle ergometer, both devices displayed negative bias, but there was significantly higher mean error for Fitbit compared with Garmin (Fitbit: −40.5% [SD 30.2], Garmin: −7.9% [SD 27.6]; P<.001).”
Quote in the paperNot a substantial claim - Findingown data
HR, as measured by the Garmin, is significantly improved when the device is in the activity mode setting.
“Third, we show that HR, as measured by the Garmin, is significantly improved when the device is in the activity mode setting.”
- Also stated in: § Principal Findings · plain
“The Garmin device performed better when the exercise type was indicated through a button press on the watch.”
Quote in the paperSubstantial claim - Also stated in: § Principal Findings · plain
- Findingown data
Garmin was significantly more accurate than Fitbit at estimating EE during MAX.
“Garmin was significantly more accurate than Fitbit at estimating EE during MAX (Fitbit: 31.5% [SD 21.5], Garmin: 22.9% [SD 16.8]; P=.047) and all cycle ergometer activities (Fitbit: 42.7% [SD 26.8], Garmin: 22.8% [SD 16.6]; P=.03).”
Quote in the paperSubstantial claim - Findingown data
Both activity monitors showed reasonable accuracy in HR.
“Although both activity monitors showed reasonable accuracy in HR, we did see differences between the 2 activity monitors in EE estimates across all activities, and both activity monitors correlated poorly with indirect calorimetry measures of EE.”
Quote in the paperSubstantial claim - Findingown data
For Garmin, the lowest mean error in measuring EE was observed during MAX-C (−4.5% [SD 25.3]) and HIIT-T (−4.7% [SD 29.3]).
“The lowest mean error in measuring EE was observed during ADL (−8.8% [SD 29.2]) for Fitbit and MAX-C (−4.5% [SD 25.3]) and HIIT-T (−4.7% [SD 29.3]) for Garmin.”
Quote in the paperNot a substantial claim - Findingown data
Both Garmin and Fitbit devices produce spurious heart rate (HR) measurements during periods of nonwrist use.
“During the early-phase testing of these devices, it was discovered that both devices would produce spurious HR measurements during periods of nonwrist use, such as when devices were stored in a backpack during commute.”
- Also stated in: § Spurious Heart Rate Measurements · plain
“Using a standard bench-top variable speed laboratory nutator (Fisher Sci # S06622), we simulated 3D wrist rotating motion at a fixed speed (22 rpm), and we recorded spurious HR results from both Garmin and Fitbit devices.”
Quote in the paperSubstantial claim - Also stated in: § Spurious Heart Rate Measurements · plain
- Findingown data
Fitbit was significantly more accurate than Garmin at estimating EE during ADL.
“Fitbit was significantly more accurate than Garmin at estimating EE during ADL (ADL: 20.9% [SD 21.8], ergometer: 42.7% [SD 26.8]; P=.02) and all treadmill activities (Treadmill: 16.9% [SD 10.9], ergometer: 42.7% [SD 26.8]; P=.003) compared with all activities performed on the cycle ergometer.”
Quote in the paperNot a substantial claim - Findingown data
For Fitbit, the lowest mean error in measuring energy expenditure (EE) was observed during activities of daily living (ADL) (−8.8% [SD 29.2]).
“The lowest mean error in measuring EE was observed during ADL (−8.8% [SD 29.2]) for Fitbit and MAX-C (−4.5% [SD 25.3]) and HIIT-T (−4.7% [SD 29.3]) for Garmin.”
Quote in the paperNot a substantial claim - Findingown data
There were differences between the 2 activity monitors in EE estimates across all activities.
“Although both activity monitors showed reasonable accuracy in HR, we did see differences between the 2 activity monitors in EE estimates across all activities, and both activity monitors correlated poorly with indirect calorimetry measures of EE.”
Quote in the paperSubstantial claim - Findingown data
Even with the inclusion of BMR in EE estimates, Fitbit still displayed a greater negative bias during most activities compared with Garmin.
“Even with the inclusion of BMR in EE estimates, Fitbit still displayed a greater negative bias during most activities compared with Garmin.”
Quote in the paperSubstantial claim - Findingown data
Both activity monitors correlated poorly with indirect calorimetry measures of EE.
“Although both activity monitors showed reasonable accuracy in HR, we did see differences between the 2 activity monitors in EE estimates across all activities, and both activity monitors correlated poorly with indirect calorimetry measures of EE.”
Quote in the paperSubstantial claim - Findingown data
For Garmin, the highest error in measuring EE was observed during resistance exercise (21.0% [SD 35.7]).
“The highest error was observed during MAX-C (−39.1% [SD 30.6]) and HIIT-C (−41.9% [SD 31.3]) for Fitbit and resistance (21.0% [SD 35.7]) for Garmin.”
Quote in the paperNot a substantial claim - Findingnone given
The EE estimates provided by these devices were inaccurate during all activities.
“The EE estimates provided by these devices were inaccurate during all activities.”
Quote in the paperSubstantial claim - Findingown data
During steady-state activities and during low-intensity activities, the HR measurements were within an acceptable error range (5%).
“We found that during steady-state activities and during low-intensity activities, the HR measurements were within an acceptable error range (5%) but less accurate during higher intensity more dynamic activities that do not involve wrist motion.”
Quote in the paperSubstantial claim - Findingown data
The mean error of the HR measurement was within the acceptable range for both devices.
“Although the mean error of the HR measurement was within the acceptable range for both devices, the range of the error was wider than anticipated.”
Quote in the paperSubstantial claim - Findingown data
HR measurements were less accurate during higher intensity more dynamic activities that do not involve wrist motion.
“We found that during steady-state activities and during low-intensity activities, the HR measurements were within an acceptable error range (5%) but less accurate during higher intensity more dynamic activities that do not involve wrist motion.”
Quote in the paperSubstantial claim - Interpretationown data
Accuracy of the two devices was compromised markedly when activities involving less wrist motion such as cycle ergometry were done.
“or when activities involving less wrist motion such as cycle ergometry were done.”
Quote in the paperSubstantial claim - Interpretationown data
Accuracy of the two devices was compromised markedly when the activity indicator was not used on the watch.
“Accuracy was compromised markedly when the activity indicator was not used on the watch”
Quote in the paperSubstantial claim - Interpretationown data
The majority of heart rate error was from devices failing to track during dynamic activities.
“The majority of error was from devices failing to track during dynamic activities.”
Quote in the paperSubstantial claim - Premisecitation
EE values are dependent on many anthropometric characteristics of the subject as well as the HR measurements.
“EE values are dependent on many anthropometric characteristics of the subject as well as the HR measurements [14].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [14] source
- Premisenone given
On-wrist/off-wrist detection algorithms are currently not a part of the activity monitors evaluated.
“Integration of these devices into a life-supporting drug delivery system must account for an on-wrist/off-wrist detection algorithms, which are currently not a part of the activity monitors evaluated.”
Quote in the paperNot a substantial claim - Interpretationreasoning
This issue and the inaccuracies associated with the EE data could lead to issues with estimating the intensity of the activity accurately.
“This issue and the inaccuracies associated with the EE data could lead to issues with estimating the intensity of the activity accurately.”
Quote in the paperSubstantial claim - Interpretationown data
The range of the error of HR measurement was wider than anticipated.
“Although the mean error of the HR measurement was within the acceptable range for both devices, the range of the error was wider than anticipated.”
Quote in the paperSubstantial claim - Study design and conductnone given
Our study only tested 2 popular consumer-grade devices.
“Our study has a limitation in that we only tested 2 popular consumer-grade devices.”
Quote in the paperNot a substantial claim - Interpretationown data
Findings from this study indicate that detecting quick nonsteady exercises might be challenging for activity monitors to capture.
“Additionally, short nonsteady state exercises such as a 10-second maximal sprint have been shown to influence the rapid change in glucose response to aerobic exercise [39], but findings from this study indicate that detecting these quick nonsteady exercises might be challenging for activity monitors to capture.”
Quote in the paperSubstantial claim - Study design and conductnone given
HR measurements from the wearable devices were not compared against a true gold standard such as ECG.
“Another limitation was that HR measurements from the wearable devices were not compared against a true gold standard such as ECG.”
Quote in the paperNot a substantial claim
- Classified as probably not a substantial claim. 31
- May combine two claims. 18
- The quote only partly states this claim. 4
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationIn people with type 1 diabetes, aerobic exercise is known to cause steep drops in blood glucose levels, whereas anaerobic exercise can cause glucose levels to rise.
“For example, in people with type 1 diabetes, aerobic exercise is known to cause steep drops in blood glucose levels, whereas anaerobic exercise can cause glucose levels to rise [3].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [3] source
Classified as probably not a substantial claim.
PremisecitationA 5% level of accuracy was adopted as the widely accepted acceptable limit.
“We adopted the widely accepted level of accuracy of 5% to be within the acceptable limits [16].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [16] source
The Methods (§2.5, Error) set 5% error as within acceptable limits. But the paper calls statistical significance—not 5% measurement accuracy—a widely accepted standard, and the Discussion (§4) describes its clinically acceptable error threshold as a proposed standard. It therefore supports adopting the 5% limit, but not calling that accuracy limit widely accepted. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Classified as probably not a substantial claim.
PremisecitationMonitoring of patient physical activity levels may be helpful in implementing insulin and/or nutritional strategies to optimize glucose control in type 1 diabetes.
“Monitoring of patient physical activity levels may be helpful in implementing insulin and/or nutritional strategies to optimize glucose control in type 1 diabetes [4].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [4] source
The Introduction (page unavailable) says exercise type affects blood glucose in type 1 diabetes and that insulin adjustments or carbohydrate intake can affect the response. The Discussion (page unavailable) also reports different glucose responses to continuous and circuit-based exercise. The paper does not establish that monitoring patients’ physical activity levels helps implement insulin or nutritional strategies; its monitoring recommendation concerns blood glucose. (LLM, conf=0.78)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationActivity monitors can be used in conjunction with on-body continuous glucose monitors, an insulin pump and a control algorithm to adjust insulin delivery, and perhaps glucagon delivery in real time.
“In theory, activity monitors can be used in conjunction with on-body continuous glucose monitors, an insulin pump and a control algorithm to adjust insulin delivery, and perhaps glucagon delivery in real time [5,6].”
Quote in the paperNot a substantial claim1 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationA recent review by Bunn et al showed that EE was generally underestimated by physical activity devices and that HR measurements were generally more accurate at rest or on a cycle ergometer as compared with treadmill.
“A recent review by Bunn et al [33] showed that EE was generally underestimated by physical activity devices and that HR measurements were generally more accurate at rest or on a cycle ergometer as compared with treadmill.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [33] Bunn, JA, 2018, Int J Exerc Sci source
Classified as probably not a substantial claim.
PremisecitationAutomated insulin delivery systems can potentially modify insulin dosing in response to activity monitors to reduce the risk or severity of exercise-induced hypoglycemia in people living with type 1 diabetes.
“Automated insulin delivery systems can potentially modify insulin dosing in response to activity monitors to reduce the risk (or severity) of exercise-induced hypoglycemia in people living with type 1 diabetes [7-10].”
Quote in the paperSubstantial claim3 of 4 sources checked- cites [7] source
The Discussion reports that the system reduced or suspended insulin delivery during or after exercise, supporting the potential to respond to exercise-related hypoglycemia. But the Results explicitly state that there was no activity measurement: the controller responded to continuous glucose monitor readings, not activity monitors. Our copy provides no page number for these passages. (LLM, conf=0.91)
Experimental — accuracy not yet measured - cites [8] source
- cites [9] source
- cites [10] source
May combine two claims.
PremisecitationIn recent studies involving predominantly steady-state aerobic activities, wrist-worn activity monitors have been shown to have reasonable accuracy in heart rate estimation (approximately 5% error) but a poor estimate of energy expenditure, where the error was found to be closer to approximately 30% with a negative bias.
“In recent studies involving predominantly steady-state aerobic activities, wrist-worn activity monitors have been shown to have reasonable accuracy in HR estimation (approximately 5% error) but a poor estimate of EE, where the error was found to be closer to approximately 30% with a negative bias [16,17].”
Quote in the paperSubstantial claim2 of 2 sources checked- cites [16] source
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured - cites [17] source
The Discussion (Principal Findings; page not available) says the Apple Watch does not substantially overestimate or underestimate heart rate, supporting the qualitative heart-rate point. It gives no approximately 5% heart-rate error or approximately 30% negatively biased energy-expenditure error. The Results report a 10-percentage-point underestimation of the moderate-intensity exercise threshold, which is a different measure. (LLM, conf=0.83)
Experimental — accuracy not yet measured
Classified as probably not a substantial claim.
PremisecitationShort nonsteady state exercises such as a 10-second maximal sprint have been shown to influence the rapid change in glucose response to aerobic exercise.
“Additionally, short nonsteady state exercises such as a 10-second maximal sprint have been shown to influence the rapid change in glucose response to aerobic exercise [39], but findings from this study indicate that detecting these quick nonsteady exercises might be challenging for activity monitors to capture.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [39] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSkin color could influence the accuracy of the HR measurement.
“It has been reported that skin color could influence the accuracy of the HR measurement [16], and future studies should report the Fitzpatrick skin tone scale to account for this limitation.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [16] source
The quote only partly states this claim.
Findingown dataMore heart rate error was observed when the exercise mode indicator was not used.
“There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used.”
Quote in the paperSubstantial claimThe quote only partly states this claim.
Findingown dataFitbit Charge 2 and Garmin vívosmart HR+ were reasonably accurate at measuring heart rate across all activities.
“Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias.”
Quote in the paperSubstantial claimThe quote only partly states this claim.
Findingown dataFitbit and Garmin showed an overall systematic negative bias in heart rate measurement across all activities.
“For HR data collected with the activity mode indicated, a systematic negative bias was observed in both Fitbit and Garmin devices.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe mean absolute percentage error (MAPE) for Garmin and Fitbit was 27.0% (SD 21.8) and 25.1% (SD 17.3), respectively.
“MAPE (SD) for Garmin and Fitbit was 27.0% (SD 21.8) and 25.1% (SD 17.3), respectively.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S1 (asserted), S3 (load-bearing), S4 (based). The quote only partly states this claim.
Findingown dataFitbit was significantly more accurate than Garmin at estimating EE during all treadmill activities.
“Fitbit was significantly more accurate than Garmin at estimating EE during ADL (ADL: 20.9% [SD 21.8], ergometer: 42.7% [SD 26.8]; P=.02) and all treadmill activities (Treadmill: 16.9% [SD 10.9], ergometer: 42.7% [SD 26.8]; P=.003) compared with all activities performed on the cycle ergometer.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataHR accuracy as measured by these activity monitors is acceptable during low-intensity activities and high-intensity activities with repetitive wrist motion but is poorer when there is no repetitive wrist motion and when any activity is at a high intensity (≥70% of maximal aerobic capacity).
“Second, we show that HR accuracy as measured by these activity monitors is acceptable during low-intensity activities and high-intensity activities with repetitive wrist motion but that HR accuracy is poorer when there is no repetitive wrist motion and when any activity is at a high intensity (ie, ≥70% of maximal aerobic capacity).”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown dataTwo common wrist-worn devices show good heart rate accuracy, with a small negative bias, and reasonable energy expenditure estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise.
“Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise.”
Quote in the paperSubstantial claim- Rests on an assumption: The selected activities of daily living and structured exercises represent common daily physical activities and types of structured exercise relevant to users of wrist-worn activity monitors.
- Rests on an assumption: The 20 healthy adults studied are representative of the broader population of wrist-worn activity monitor users.
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductcitationParticipants were screened for cardiovascular complications using the Physical Activity Readiness Questionnaire.
“Participants were screened for any cardiovascular complications using a Physical Activity Readiness Questionnaire [25].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [25] Eparmedx2018-10-31Physical Activity Readiness Questionnaire http://eparmedx.com/wp-content/uploads/2013/01/January2018PARQPlus.pdf
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone givenTwo wearable devices, one of each brand, were tested at the same time on all participants using a randomized and counterbalanced method.
“Two wearable devices (one of each brand) were tested at the same time on all participants (one on each wrist as per manufacturer’s instructions) using a randomized and counterbalanced method.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenAll 20 participants recruited for the study completed the procedures.
“All 20 participants recruited for the study completed the procedures.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Study design and conductnone givenData from the Polar heart rate monitor served as the reference standard for heart rate in beats per minute.
“Data from the Polar HR monitor served as the as the reference standard for HR (beats per minute, bpm).”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone givenThe experimental protocol conformed to the Declaration of Helsinki and was approved by the institutional review board at Oregon Health and Science University and by the research ethics board at York University.
“The experimental protocol conformed to the standards set by the Declaration of Helsinki and was approved by the institutional review board at the Oregon Health and Science University (OHSU, Portland Oregon) and by the research ethics board at York University (Toronto, Canada).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductown dataDue to a limitation on the Garmin Connect application, energy expenditure data could only be compared at a low resolution, namely an average across each activity mode.
“Due to the limitation on the Garmin Connect application, EE data could only be compared at a low resolution, namely an average across each activity mode (eg, ADL, HIIT-C, or HIIT-T).”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Study design and conductnone givenData from indirect calorimetry served as the reference standard measurement for calculations of energy expenditure in kcal/min.
“Data from the indirect calorimetry (VO2 and carbon dioxide consumption [VCO2]) served as the reference standard measurement for calculations of EE (kcal/min).”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenAll devices were synchronized to a single clock before the exercise protocol commenced.
“synchronization of all the devices to a single clock before the exercise protocol commenced.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationPPG sensors used to measure HR are liable to poor accuracy during activities with increased physical exertion or activities involving repetitive contractions of forearm skeletal muscles.
“Prior research has suggested that PPG sensors used to measure the HR are liable to poor accuracy during activities with increased physical exertion or activities involving repetitive contractions of forearm skeletal muscles [36-38].”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationBourdreaux et al demonstrated that heart rate measured by nonwrist worn devices was relatively accurate, whereas wrist-worn devices showed poor correlations (R<.8) and higher error during resistance exercises (mean absolute percent error >9%).
“Results from this study demonstrated that HR measured by nonwrist worn devices were relatively accurate, whereas wrist-worn devices showed poor correlations (R<.8) and higher error during resistance exercises (mean absolute percent error [MAPE] >9%).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [24] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
InterpretationreasoningIf EE estimates by Garmin included BMR, there would likely be greater accuracy in the EE values reported by these devices.
“If EE estimates by Garmin included BMR, there would likely be greater accuracy in the EE values reported by these devices.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim. May combine two claims.
PremisecitationDuring activities involving sustained muscle contractions or higher intensity exercises, the contact between the device's PPG sensor and skin is decreased, leading to a disruption in the signal quality and causing poor quality data.
“It has been suggested that during activities involving sustained muscle contractions or higher intensity exercises, the contact between the device’s PPG sensor and skin is decreased, leading to a disruption in the signal quality and causing poor quality data [36,37].”
Quote in the paperSubstantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationBai et al reported that energy expenditure measured during an unstructured resistance exercise protocol in which participants selected exercises and loads was inaccurate across numerous devices.
“Bai et al [21] reported that EE measured during an unstructured resistance exercise protocol in which participants selected exercises and loads was inaccurate across numerous devices.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [21] source
May combine two claims.
PremisecitationPresently, there are at least four studies that have investigated the accuracy of wearable devices during resistance exercises and none during high-intensity interval training.
“Presently, there are at least 4 studies [21-24] that have investigated the accuracy of wearable devices during resistance exercises and none during HIIT training.”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [21] source
- cites [22] source
- cites [23] Jo, E, 2016, J Sports Sci Med
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [24] source
- Rests on an assumption: In free-living conditions, many individuals often perform resistance exercise using free weights or their own body weight, followed by some form of high-intensity interval training within the same session.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationJo E et al reported poor correlation and heart rate accuracy in the Fitbit Charge HR device.
“Jo E et al [23] reported poor correlation and HR accuracy in the Fitbit Charge HR device.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [23] Jo, E, 2016, J Sports Sci Med
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationDondzila et al found that with aerobic exercise under laboratory conditions, the Fitbit Charge HR underestimated the HR compared with a Polar chest strap, with higher error at slower speeds.
“Dondzila et al [34] also looked at the Fitbit Charge HR and found that with aerobic exercise under laboratory conditions, the Fitbit Charge HR underestimated the HR compared with a Polar chest strap, with higher error at slower speeds.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [34] Dondzila, C, 2018, Int J Exerc Sci source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationBourdreaux et al showed that energy expenditure measured by the devices was poor, with mean absolute percent error values ranging between 43% and 57%.
“They also showed that the EE measured by the devices was poor, with MAPE values ranging between 43% and 57%.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [24] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationJo et al found a negative bias of HR with respect to ECG measurements for the Basis Peak and the Fitbit Charge HR.
“Jo et al [35] compared the Basis Peak and the Fitbit Charge HR with ECG and also found a negative bias of HR with respect to ECG measurements (−4.9 bpm for the Basis and −12.7 bpm for the Fitbit).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [35] Jo, E, 2016, J Sports Sci Med
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S2 (checkable), S4 (based).
PremisereasoningFor any medical system utilizing an activity monitor, the accuracy of the heart rate and energy expenditure estimates by the activity monitor is critical as it can influence medical dosing decisions and patient outcomes.
“For any medical system utilizing an activity monitor, the accuracy of the HR and EE estimates by the activity monitor is critical as it can influence medical dosing decisions and patient outcomes.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationHorton et al assessed the validity of heart rate only using the Polar M600 when compared with a 3-lead electrocardiogram during both aerobic and resistance exercises, and the accuracy of the wearable device was reported to be better during aerobic exercise (92%) than during resistance exercises (35%).
“Horton et al [22] assessed the validity of HR only using the Polar M600 when compared with a 3-lead electrocardiogram (ECG) during both aerobic and resistance exercises. The accuracy of the wearable device was reported to be better during aerobic exercise (92%) as compared with only 35% accurate during the resistance exercises.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [22] source
Probably not a substantial claim: may not pass S4 (based). May combine two claims.
Premisenone givenAccording to the manufacturers, Fitbit's EE estimate includes both active calories and the basal metabolic rate (BMR), whereas Garmin only reports active calories without BMR.
“According to the manufacturers, Fitbit’s EE estimate includes both active calories and the basal metabolic rate (BMR), whereas Garmin only reports active calories without BMR.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationown dataThe findings from this study point to shortcomings that could arise in both detecting activity and distinguishing the type of activity based on the HR signal.
“The findings from this study point to shortcomings that could arise in both detecting activity and distinguishing the type of activity based on the HR signal.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Study design and conductnone givenExercise was conducted in a laboratory setting as opposed to the real world.
“Another limitation of our study is that exercise was conducted in a laboratory setting as opposed to the real world.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone givenWe attempted to capture several real-world ADLs to minimize the laboratory setting limitation, though these activities were also recorded within a lab.
“However, we attempted to capture several real-world ADLs to minimize this limitation, though these activities were also recorded within a lab.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductcitationOur current data and interpretations may be limited as we did not account for the skin color in our study.
“Our current data and interpretations may be limited as we did not account for the skin color in our study.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Premisenone givenNeither of these watches provide real-time access to their data streams.
“Currently, neither of these watches provide real-time access to their data streams.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing).
InterpretationreasoningIntegrating these activity monitors into medical systems such as type 1 diabetes decision support systems or automated drug delivery systems in the future will require high fidelity data both from the HR signal and the EE estimates.
“Integrating these activity monitors into medical systems such as type 1 diabetes decision support systems or automated drug delivery systems in the future will require high fidelity data both from the HR signal and the EE estimates.”
Quote in the paperNot a substantial claim
The paper relies on this without support.
The selected activities of daily living and structured exercises represent common daily physical activities and types of structured exercise relevant to users of wrist-worn activity monitors.
“Six ADLs were performed to simulate daily chores.”
The paper relies on this without support.
The 20 healthy adults studied are representative of the broader population of wrist-worn activity monitor users.
“This study recruited 20 healthy adults (11 females; 10 subjects at OHSU; 10 at York University) who all provided informed consent before taking part in the study.”
The paper relies on this without support.
In the diabetes population, patients are encouraged to perform both resistance and aerobic training all in one session.
“In fact, in the diabetes population, patients are encouraged to perform both resistance and aerobic training all in one session.”
The paper relies on this without support.
In free-living conditions, many individuals often perform resistance exercise using free weights or their own body weight, followed by some form of high-intensity interval training within the same session.
“For example, in free-living conditions, many individuals often perform resistance exercise using free weights or their own body weight, followed by some form of high-intensity interval training (HIIT) within the same session.”
The authors state this as an assumption.
The EE estimations provided by these devices utilize anthropometric characteristics and HR measurements.
“We assume that the EE estimations provided by these devices are also utilizing this information, but these calculations are proprietary.”
The paper relies on this without support.
The algorithms running on these wearables that estimate HR and EE are proprietary and can change without warning from the manufacturers.
“Clearly, the algorithms running on these wearables that estimate HR and EE are proprietary and can change without warning from the manufacturers, which poses further challenges for those wanting to integrate these devices into medical products.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Apple and Fitbit's proprietary algorithms outperform smaller-brand or open-source counterparts, largely because of superior noise filtering and adaptive calibration.
“Comparative evaluations indicate that Apple and Fitbit’s proprietary algorithms outperform smaller-brand or open-source counterparts, largely because of superior noise filtering and adaptive calibration [9,11].”
From Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring (2025) · cites this paper as [11]
The Results (Heart Rate Accuracy; page unavailable) report no accuracy difference between Fitbit and Garmin when activity mode was indicated. The Results (Energy Expenditure Accuracy; page unavailable) report less overall bias for Garmin and significantly better Garmin accuracy in some activities, contrary to the claimed general superiority of Fitbit. The study did not compare Apple or open-source algorithms, or establish noise filtering and adaptive calibration as explanations. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredCyclical motion can affect the accuracy of heart rate in wearable sensors.
“Several research groups and manufacturers have identified that cyclical motion can affect accuracy of HR in wearable sensors.”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
HIIT cycling heart-rate correlations are assigned the wrong values
MajorThe text gives Fitbit and Garmin correlations of 0.46 and 0.71 for HIIT cycling, but the HIIT cycling row of Table 2 gives 0.56 and 0.47. The stated values instead match the table's maximal cycling test.
“poor correlation between the HR values was observed during the HIIT-C (Fitbit: 0.46, Garmin: 0.71).”
“| | Pearson correlation | .56 | .56 | .47 | .47 | .42 | .42 |”
HIIT cycling is not Fitbit's highest heart-rate error
MinorThe abstract identifies HIIT cycling as having the highest error, but the paper reports a larger-magnitude mean error for Fitbit during maximal cycling: −16.4% versus −11.4%.
“The highest error was observed during high-intensity intervals on bike (Fitbit: −11.4% [SD 35.7]; Garmin: −14.3% [SD 20.5])”
“during MAX-C (Fitbit: −16.4% [SD 21.6], Garmin: −9.3% [SD 17.0]).”
Conflicting SDs for Fitbit's HIIT cycling EE relative error
MinorTable 3 reports an SD of 1.3 for Fitbit's −41.9% relative error during HIIT cycling, while the results text reports an SD of 31.3 for the same value.
“| | % mean relative error (SD) | % mean relative error (SD) | −41.9 (1.3) | −41.9 (1.3) | −11.2 (30.8) |”
“HIIT-C (−41.9% [SD 31.3]) for Fitbit”
Fitbit is called more accurate for daily activities despite higher absolute error
MinorThe text says Fitbit was more accurate than Garmin during activities of daily living, whereas Table 3 reports a higher mean absolute EE error for Fitbit (20.9%) than for Garmin (17.0%).
“Fitbit was significantly more accurate than Garmin at estimating EE during ADL”
“| | % mean absolute error (SD) | % mean absolute error (SD) | 20.9 (21.8) | 20.9 (21.8) | 17.0 (13.7) |”
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Exercise management in type 1 diabetes: a consensus statement
Riddell, M. C., Gallen, I. W., Smart, C. E., Taplin, C. E., Adolfsson, P., Lumb, A. N., Kowalski, A., Rabasa-Lhoret, R., McCrimmon, R. J., Hume, C., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30014-1 · Cited by 903 · see citing works
Self-citationShcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625 · see citing works
Jelleyman, C., Yates, T., O'Donovan, G., Gray, L. J., King, J. A., Khunti, K., & Davies, M. J. (2015) · Obesity Reviews · doi:10.1111/obr.12317 · Cited by 588 · see citing works
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542 · see citing works
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 1× · see citing works
“In the earlier models of activity monitors, only accelerometers were used to estimate EE [11], but in more recent multisensor models, photoplethysmography (PPG) is being used to estimate HR [12] and, potentially, to improve the accuracy in estimating EE [13].”
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
Stahl, S. E., An, H.-S., Dinkel, D. M., Noble, J. M., & Lee, J.-M. (2016) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000106 · Cited by 276 · see citing works
Dooley, E. E., Golaszewski, N. M., & Bartholomew, J. B. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7043 · Cited by 242 · see citing works
Validity of Wearable Activity Monitors during Cycling and Resistance Exercise
BOUDREAUX, B. D., HEBERT, E. P., HOLLANDER, D. B., WILLIAMS, B. M., CORMIER, C. L., NAQUIN, M. R., GILLAN, W. W., GUSEW, E. E., & KRAEMER, R. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001471 · Cited by 205 · see citing works
Current State of Commercial Wearable Technology in Physical Activity Monitoring 2015-2017
Bunn, J., Navalta, J. W., Fountaine, C. J., & Reece, J. (2018) · International Journal of Exercise Science · doi:10.70252/njqx2719 · Cited by 194 · see citing works
Breton, M. D., Cherñavvsky, D. R., Forlenza, G. P., DeBoer, M. D., Robic, J., Wadwa, R. P., Messer, L. H., Kovatchev, B. P., & Maahs, D. M. (2017) · Diabetes Care · doi:10.2337/dc17-0883 · Cited by 179 · see citing works
Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.
(2016) · PubMed Central · Cited by 150 · see citing works
Comparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149 · see citing works
Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR
Bai, Y., Hibbing, P. R., Mantis, K., & Welk, G. J. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1412235 · Cited by 147 · see citing works
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139 · see citing works
Breton, M. D., Brown, S. A., Karvetski, C. H., Kollar, L., Topchyan, K. A., Anderson, S. M., & Kovatchev, B. P. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0333 · Cited by 128 · see citing works
Chowdhury, E. A., Western, M. J., Nightingale, T. E., Peacock, O. J., & Thompson, D. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171720 · Cited by 118 · see citing works
Jacobs, P. G., El Youssef, J., Reddy, R., Resalat, N., Branigan, D., Condon, J., Preiser, N., Ramsey, K., Jones, M., Edwards, C., et al. (2016) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12707 · Cited by 116 · see citing works
Self-citationJacobs, P. G., Resalat, N., El Youssef, J., Reddy, R., Branigan, D., Preiser, N., Condon, J., & Castle, J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815609371 · Cited by 105 · see citing works
Self-citationGarcía-García, F., Kumareswaran, K., Hovorka, R., & Hernando, M. E. (2015) · Sports Medicine · doi:10.1007/s40279-015-0302-2 · Cited by 101 · see citing works
Zakeri, I., Adolph, A. L., Puyau, M. R., Vohra, F. A., & Butte, N. F. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01163.2007 · Cited by 80 · see citing works
Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79 · see citing works
An Integrated Multivariable Artificial Pancreas Control System
Turksoy, K., Quinn, L. T., Littlejohn, E., & Cinar, A. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524862 · Cited by 77 · see citing works
Huyett, L. M., Ly, T. T., Forlenza, G. P., Reuschel-DiVirgilio, S., Messer, L. H., Wadwa, R. P., Gondhalekar, R., Doyle, F. J., Pinsker, J. E., Maahs, D. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0399 · Cited by 64 · see citing works
Self-citationZaharieva, D., Yavelberg, L., Jamnik, V., Cinar, A., Turksoy, K., & Riddell, M. C. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0010 · Cited by 61 · see citing works
Self-citationWormgoor, S. G., Dalleck, L. C., Zinn, C., & Harris, N. K. (2017) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2016.12.004 · Cited by 53 · see citing works
Early detection of physical activity for people with type 1 diabetes mellitus
Dasanayake, I. S., Bevier, W. C., Castorino, K., Pinsker, J. E., Seborg, D. E., Doyle, F. J., & Dassau, E. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815592409 · Cited by 40 · see citing works
Self-citationRooijackers, H. M. M., Wiegers, E. C., van der Graaf, M., Thijssen, D. H. J., Kessels, R. P. C., Tack, C. J., & de Galan, B. E. (2017) · Diabetes · doi:10.2337/db16-1535 · Cited by 39 · see citing works
Davey, R. J., Bussau, V. A., Paramalingam, N., Ferreira, L. D., Lim, E. M., Davis, E. A., Jones, T. W., & Fournier, P. A. (2013) · Diabetes Care · doi:10.2337/dc12-2198 · Cited by 21 · see citing works
Measuring Moderate-Intensity Exercise with the Apple Watch: Validation Study
Abt, G., Bray, J., & Benson, A. C. (2018) · JMIR Cardio · doi:10.2196/cardio.8574 · Cited by 21 · see citing works
Rafolt, D., & Gallasch, E. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.005 · Cited by 19 · see citing works
Congruent Accuracy of Wrist-worn Activity Trackers during Controlled and Free-living Conditions
Dondzila, C. J., Lewis, C., Lopez, J. R., & Parker, T. (2018) · International Journal of Exercise Science · doi:10.70252/ubbt6886 · Cited by 16 · cited 1× · see citing works
“Dondzila et al [34] also looked at the Fitbit Charge HR and found that with aerobic exercise under laboratory conditions, the Fitbit Charge HR underestimated the HR compared with a Polar chest strap, with higher error at slower speeds.”
Helal, L. C. A. S., Umpierre, D., & Moraes, R. S. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3682-1 · Cited by 2 · see citing works
Flagged first, then by citations
Research works printed but not linked: 3
- Jo, E, 2016, J Sports Sci Med, 15, 540
- Borg, GA, 1982, Med Sci Sports Exerc, 14, 377
- Jo, E, 2016, J Sports Sci Med, 15, 540
Cited by
Sorted by citations
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673 · see citing works
“Several research groups and manufacturers have identified that cyclical motion can affect accuracy of HR in wearable sensors.(9,10,15) The cyclical motion challenge has been described as a “signal crossover” effect wherein the optical HR sensors on wearables tend to lock on to the periodic signal stemming from the”
BackgroundZhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
The role of wearables in heart failure
Singhal, A., & Cowie, M. R. (2020) · Current Heart Failure Reports · doi:10.1007/s11897-020-00467-x · Cited by 85 · see citing works
Ajmal, Boonya-Ananta, T., Rodriguez, A. J., Du Le, V. N., & Ramella-Roman, J. C. (2021) · Biomedical Optics Express · doi:10.1364/boe.439893 · Cited by 79 · see citing works
Skin tone, confidence, and data quality of heart rate sensing in WearOS smartwatches
Ray, I., Liaqat, D., Gabel, M., & de Lara, E. (2021) · 2021 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) · doi:10.1109/percomworkshops51409.2021.9431120 · Cited by 23 · see citing works
Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring
Asif, S., AlSaafeen, A., Nadar, S., Nambiar, S., Dannawi, J., Korrapati, H., & Wilkhoo, H. S. (2025) · Cureus · doi:10.7759/cureus.94074 · Cited by 9 · see citing works
- Authors
- Reddy, R. K., Pooni, R., Zaharieva, D. P., Senf, B., El Youssef, J., Dassau, E., Doyle III, F. J., Clements, M. A., Rickels, M. R., Patton, S. R., Castle, J. R., Riddell, M. C., & Jacobs, P. G.
- Affiliations
- York University (CA)
- Oregon Health & Science University (US)
- Harvard University (US)
- Children's Mercy Hospital (US)
- University of Pennsylvania (US)
- University of Kansas Medical Center (US)
- Corresponding author
- Jacobs, Peter G
- ORCID
- Venue
- JMIR mHealth and uHealth
- Publisher
- JMIR Publications Inc.
- Published
- 2018-12-10
- Volume
- 6
- Issue
- 12
- Pages
- e10338
- ISSN
- 2291-5222 (ISSN-L)
- PMC
- PMC6305876
- OpenAlex
- W2889730139
- Semantic Scholar
- 13b617c10b60392edf8a861866c771c62c517ddd
- Cited by
- 157
- References
- 36
- Citations by year
- 2026: 11 · 2025: 11 · 2024: 20 · 2023: 24 · 2022: 26 · 2021: 27 · 2020: 22 · 2019: 15 · 2016: 1
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR mhealth and uhealth (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (submittedVersion, cc-by)
- PubMed Central (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Leona M. and Harry B. Helmsley Charitable Trust
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- wrist-worn activity monitors, heart rate monitoring, energy expenditure estimation, Fitbit, Garmin, interval training, activities of daily living, VO2max, indirect calorimetry, high-intensity exercise, measurement bias, real-time physiological monitoring, wearable medical devices, clinical decision support systems, smartwatches
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review