Muscle Oximetry in Sports Science: A Systematic Review
Open accessThe DOI matches its Crossref record; 93 of the 95 references it cites were found in a registry or an index.
Abstract
Background Since the introduction (in 2006) of commercially available portable wireless muscle oximeters, the use of muscle near-infrared spectroscopy (NIRS) technology is gaining in popularity as an application to observe changes in muscle metabolism and muscle oxygenation during and after exercise or training interventions in both laboratory and applied sports settings. Objectives The objectives of this systematic review were to highlight the application of muscle oximetry in evaluating oxidative skeletal muscle performance to sport activities and emphasize how this technology has been applied to exercise and training. Methods Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed in a systematic fashion to search, assess and synthesize existing literature on this topic. The Scopus and MEDLINE/PubMed electronic databases were searched to 1 March 2017. Potential inclusions were screened against eligibility criteria relating to recreationally trained to elite athletes, with or without training programs, who must have assessed physiological variables monitored by commercial oximeters or NIRS instrumentation. Results Of the 14,609 identified records, only 57 studies met the eligibility criteria. This systematic review highlighted a number of key findings in 16 sporting activities. Overall, NIRS information can be used as a marker of skeletal muscle oxidative capacity and for analyzing muscle performance factors. Conclusions Although NIRS ins…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This is explained by the fact that both variables are affected by different external factors, such as muscle contractions or thermoregulation/dehydration (Perrey and Ferrari, 2018).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Perrey and Ferrari, 2018
In the citing paper
“SmO2 is being increasingly measured in exercise as a non-invasive index of muscle metabolism thanks to the development of small wearable devices that use near-infrared spectroscopy to distinguish between oxygenated and deoxygenated heme [1].”
From A Comparison of Leg Muscle Oxygenation, Cardiorespiratory Responses, and Blood Lactate between Walking and Running at the Same Speed (2024) · cites this paper as [1]
In the citing paper
“The muscles analyzed with NIRS portable had previously been studied by Perrey & Ferrari19, who showed that SmO2 was determined among different muscles (vastus lateralis, gastrocnemius medialis, intercostal, triceps brachii) and many sports (swimming, strength, skiing, speed skating, sailing, running, rugby, climbing, handball, cycling, kayak, judo, rowing, football, alpine skiing).”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [19]
In the citing paper
“Commercial muscle NIRS devices with larger source -detection distances are widely available. 6”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [6]
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042 · cited 1×
“1 Literature Search Methodology A thorough systematic search of the research literature was performed, conforming to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement [14].”
MethodPreferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Wang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 1×
“[9], utilizing the first wearable NIRS instrument dedicated to studying muscle metabolism.”
MethodFerrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450 · cited 3×
“It is well known that the relatively high attenuation of the near-infrared light in muscle measurements is due to (i) the two main chromophores (Hb and Mb); (ii) light scattering; and (iii) other molecules (mainly skin melanin, water, lipids of the adipose tissue, intramuscular lipids, and cytochrome c oxidase) [5].”
BackgroundMethodSelf-citationQuaresima, V., & Ferrari, M. (2019) · Organizational Research Methods · doi:10.1177/1094428116658959 · Cited by 419
Self-citationGrassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345 · cited 3×
“More recently, the review by Grassi and Quaresima [8], from an ‘exercise physiology point of view’, was devoted to discussing some of the main issues relating to the role of NIRS in the functional assessment of oxidative metabolism in skeletal muscles during exercise, with specific attention to integrative aspects and…”
BackgroundMethodHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Research works printed but not linked: 1
- McCully KK, Hamaoka T. Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle? Exerc Sport Sci Rev. 2000;28(3):123–7.
Cited by
Pinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
International Journal of Sports Medicine
(2026) · International Journal of Sports Medicine · doi:10.1055/s-00000028 · Cited by 966
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
“The application of this technology in athletic settings is expanding, as fundamental questions are being addressed.(1) One of the major concerns in the application of NIRS in athletic settings is that common limitations of NIRS are not well understood and need to be properly addressed, while still allowing the technol…”
BackgroundVan Hooren, B., Goudsmit, J., Restrepo, J., & Vos, S. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1690960 · Cited by 141
Muscle Oximetry in Sports Science: An Updated Systematic Review
Perrey, S., Quaresima, V., & Ferrari, M. (2024) · Sports Medicine · doi:10.1007/s40279-023-01987-x · Cited by 100
Self-citationHamaoka, T., & McCully, K. K. (2019) · The Journal of Physiological Sciences · doi:10.1007/s12576-019-00697-2 · Cited by 92
Farzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Lutz, J., Memmert, D., Raabe, D., Dornberger, R., & Donath, L. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17010059 · Cited by 114
“Because of its novelty, the only review of scientific studies stated that the current quality of research is rather low, due to the low number of available studies and asks for further research to increase the state of knowledge [80].”
BackgroundInfluentialEmerging Technologies to Image Tissue Metabolism
Ntziachristos, V., Pleitez, M. A., Aime, S., & Brindle, K. M. (2018) · Cell Metabolism · doi:10.1016/j.cmet.2018.09.004 · Cited by 82
Non-invasive Techniques for Muscle Fatigue Monitoring: A Comprehensive Survey
Li, N., Zhou, R., Krishna, B., Pradhan, A., Lee, H., He, J., & Jiang, N. (2024) · ACM Computing Surveys · doi:10.1145/3648679 · Cited by 96
Muscle Oxygenation Rather Than VO2max as a Strong Predictor of Performance in Sprint Canoe–Kayak
Paquette, M., Bieuzen, F., & Billaut, F. (2018) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0077 · Cited by 54
Tissue Oxygenation in Response to Different Relative Levels of Blood-Flow Restricted Exercise
Reis, J. F., Fatela, P., Mendonça, G. V., Vaz, J. R., Valamatos, M. J., Infante, J., Mil-Homens, P. V., & Alves, F. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00407 · Cited by 59
“NIRS Signal Near-infrared spectroscopy provides non-invasive information about the changes in oxygenation and hemodynamics in muscle tissue based on the oxygen-dependent characteristics of nearinfrared light (Perrey and Ferrari, 2018) and has been validated for multiple forms of resistance exercise (Pereira et al.”
BackgroundResultSendra-Pérez, C., Sanchez-Jimenez, J. L., Marzano-Felisatti, J. M., Encarnación-Martínez, A., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Scientific Reports · doi:10.1038/s41598-023-39651-z · Cited by 52
“NIRS technology in the sports field is being used to observe changes in the muscle metabolism of different muscles 19 .”
MethodReview of recent advances in frequency-domain near-infrared spectroscopy technologies [Invited]
Zhou, X., Xia, Y., Uchitel, J., Collins-Jones, L. H., Yang, S., Loureiro, R. C. V., Cooper, R. J., & Zhao, H. (2023) · Biomedical Optics Express · doi:10.1364/boe.484044 · Cited by 53
“NIRS has been applied in a variety of research and clinical care settings, including neonatal care [5,6], breast cancer imaging [7], muscle training [8], and neurocritical care, among others [9,10].”
BackgroundYogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49
Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise
Contreras-Briceño, F., Espinosa-Ramirez, M., Hevia, G., Llambias, D., Carrasco, M., Cerda, F., López-Fuenzalida, A., García, P., Gabrielli, L., & Viscor, G. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1653422 · Cited by 40
Miranda‐Fuentes, C., Ríos, L. J. C., Guisado-Requena, I. M., Delgado‐Floody, P., & Jerez‐Mayorga, D. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18084293 · Cited by 51
“(Fortiori Design, LLC, Hutchinson, MN, USA), BSX Insight (BSX Athletics, Austin, TX, USA) [10] and Humon Hex (Humon Beta, Dynometrics, Inc.”
BackgroundMethodInfluentialPerrey, S. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.864825 · Cited by 53
“Current wearable NIRS monitors (e.g., Moxy, BSI Insight, and Portamon devices) growing in availability, offer promising approaches but formal longitudinal and cohort studies are still needed to assess their use-case for sports (Perrey and Ferrari, 2018).”
BackgroundInfluentialSelf-citationCerebral and muscle tissue oxygenation during exercise in healthy adults: A systematic review
Orcioli‐Silva, D., Beretta, V. S., dos Santos, P. C. R., Rasteiro, F. M., Marostegan, A. B., Vitório, R., Gobatto, C. A., & Manchado-Gobatto, F. D. B. (2024) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.03.003 · Cited by 48
“Moreover, existing evidence has reported the validity of muscle NIRS measurements (e.g., [HbO 2 ] and [HHb]) in humans by comparing these measures with venous blood because NIRS signals are related to changes in venous saturation under varying oxygenation statuses of human muscles.”
BackgroundMethodInfluentialMuscle oxygen saturation rates coincide with lactate-based exercise thresholds
Batterson, P. M., Kirby, B. S., Hasselmann, G., & Feldmann, A. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05238-9 · Cited by 45
“1 3 NIRS is considered a valid estimation of oxygen supply and demand to the muscle site under investigation (Perrey and Ferrari 2018).”
BackgroundTuesta, M., Yáñez-Sepúlveda, R., Verdugo-Marchese, H., Mateluna, C., & Alvear-Ordenes, I. (2022) · Biology · doi:10.3390/biology11071073 · Cited by 37
“A recent review demonstrated that NIRS has remarkable potential for use in the assessment of acute and chronic exercise response [18].”
BackgroundInfluentialYogev, A., Arnold, J., Clarke, D., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.818733 · Cited by 35
Giminiani, R. D., Cardinale, M., Ferrari, M., & Quaresima, V. (2020) · Sensors · doi:10.3390/s20174664 · Cited by 43
“Both are considered “gold standards” for assessing NIRS-oximetry and EMG related parameters, because they have been validated and have been extensively used in basic research and clinics [9,22].”
BackgroundMethodSelf-citationScano, A., Pirovano, I., Manunza, M. E., Spinelli, L., Contini, D., Torricelli, A. M., & Re, R. (2020) · Biomedical Optics Express · doi:10.1364/boe.403976 · Cited by 36
Pirovano, I., Porcelli, S., Re, R., Spinelli, L., Contini, D., Marzorati, M., & Torricelli, A. M. (2020) · Biomedical Optics Express · doi:10.1364/boe.412447 · Cited by 42
Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running
Feldmann, A., Ammann, L., Gächter, F., Zibung, M., & Erlacher, D. (2022) · Journal of Human Kinetics · doi:10.2478/hukin-2022-0054 · Cited by 41
“, continuous-wave (Perrey and Ferrari, 2018), provides arbitrary values for concentrations of oxyhemoglobin and oxymyoglobin, and deoxyhemoglobin and deoxymyoglobin, both of which are often identified with differing acronyms.”
BackgroundCritical oxygenation: Can muscle oxygenation inform us about critical power?
Feldmann, A., & Erlacher, D. (2021) · Medical Hypotheses · doi:10.1016/j.mehy.2021.110575 · Cited by 34
Espinosa‐Ramírez, M., Moya, E., Araya-Román, F., Riquelme-Sánchez, S., Rodriguez-García, G., Reid, W. D., Viscor, G., Araneda, O. F., Gabrielli, L., & Briceño, F. A. C. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.738063 · Cited by 32
“This can be determined using continuous-wave near-infrared spectroscopy (NIRS, 630– 850 nm) that measures changes in oxygenated hemoglobin (O2 Hb) and myoglobin (mHb) at a microvascular level (Perrey and Ferrari, 2018; Alvares et al., 2020).”
Dual-Slope Diffuse Reflectance Instrument for Calibration-Free Broadband Spectroscopy
Blaney, G. P., Donaldson, R., Mushtak, S., Nguyen, H. T. N., Vignale, L., Fernandez, C. M., Pham, T., Sassaroli, A., & Fantini, S. (2021) · Applied Sciences · doi:10.3390/app11041757 · Cited by 33
“Examples include clinical brain monitoring [12], the study of brain activation [13], breast imaging [14], and muscle measurements in sports science [15].”
BackgroundMulti-laboratory performance assessment of diffuse optics instruments: the BitMap exercise
Lanka, P., Yang, L., Orive-Miguel, D., Veesa, J. D., Tagliabue, S., Sudakou, A., Samaei, S., Forcione, M., Kovácsová, Z., Behera, A., et al. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.7.074716 · Cited by 29
“20 This is confirmed from the results since all the instruments which have a hybrid PMT or MCP-based detection system (i.e., # 11, 3, 13, 14, and 15) are clustered at the top right corner of the plot suggestive of better contrast and CNR values.”
BackgroundNIRS-EMG for Clinical Applications: A Systematic Review
Scano, A., Zanoletti, M., Pirovano, I., Spinelli, L., Contini, D., Torricelli, A. M., & Re, R. (2019) · Applied Sciences · doi:10.3390/app9152952 · Cited by 30
“This includes a variety of applications, which range from the monitoring of personal health and sports performance in athletes [32] to the detection of muscular fatigue [33], or to their combination, in smart sensors, for sports and brain computer interface (BCI) applications [34].”
BackgroundDiagnosis, Pathophysiology and Management of Microvascular Dysfunction in Diabetes Mellitus
Jan, Y., Kelhofer, N. C., Tu, T., Mansuri, O., Onyemere, K. U., Dave, S. D., & Pappu, S. (2024) · Diagnostics · doi:10.3390/diagnostics14242830 · Cited by 45
“NIRS can also be used to investigate the muscle oxygen metabolism after exercise and the first study was conducted in the early 1990s [25].”
Quaresima, V., Farzam, P., Anderson, P. G., Farzam, P. Y., Wiese, D., Carp, S. A., Ferrari, M., & Franceschini, M. A. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00324.2019 · Cited by 34
Self-citationManchado-Gobatto, F. D. B., Marostegan, A. B., Rasteiro, F. M., Cirino, C., da Cruz, J. P., Moreno, M. A., & Gobatto, C. A. (2020) · Scientific Reports · doi:10.1038/s41598-020-63297-w · Cited by 36
Determination of Second Lactate Threshold Using Near-infrared Spectroscopy in Elite Cyclists
Salas-Montoro, J.-A., Mateo-March, M., Sánchez-Muñoz, C., & Zabala, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1738-0252 · Cited by 27
“Although NIRS technology has been around for decades [17], the first wearable muscle oximeter device appeared in 2006 and provided only oxygenation changes expressed in arbitrary units or concentration changes in oxy-hemoglobin and deoxy-hemoglobin (HHb) to determine the muscle’s oxygen use [18].”
BackgroundMethodRaberin, A., Elmer, J., Willis, S. J., Richard, T., Vernillo, G., Iaia, F. M., Girard, O., Malatesta, D., & Millet, G. P. (2022) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003042 · Cited by 35
“This NIRS technique has been extensively described and validated in the literature (26).”
MethodMuscle mitochondrial capacity in high‐ and low‐fitness females using near‐infrared spectroscopy
Lagerwaard, B., Janssen, J. J. E., Cuijpers, I., Keijer, J., de Boer, V. C. J., & Nieuwenhuizen, A. G. (2021) · Physiological Reports · doi:10.14814/phy2.14838 · Cited by 26
Walters, J., Kottke, M. A., Hargens, A. R., & Ryan, K. L. (2019) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000002284 · Cited by 26
Theodorou, A. A., Zinelis, P. T., Malliou, V. J., Chatzinikolaou, P. N., Margaritelis, N. V., Mandalidis, D. G., Geladas, N. D., & Paschalis, V. (2021) · Nutrients · doi:10.3390/nu13103311 · Cited by 33
Manfredini, F., Lamberti, N., Ficarra, V., Tsolaki, E., Straudi, S., Zamboni, P., Basaglia, N., & Gasbarro, V. (2020) · Diagnostics · doi:10.3390/diagnostics10050312 · Cited by 27
“The technique has also been applied to monitor oxygenation during treadmill test [22,23], in response to endovascular revascularization [24] or home-based walking programs [25] Finally, NIRS was used to determine the perfusion of several muscular district in response to motor tasks [7] or use of devices as intermitten…”
MethodUnderwater near-infrared spectroscopy can measure training adaptations in adolescent swimmers
Jones, B. L., Parry, D. A., & Cooper, C. E. (2018) · PeerJ · doi:10.7717/peerj.4393 · Cited by 29
“The growing use of portable NIRS in an applied sport setting has been well documented (Ferrari, Muthalib & Quaresima, 2011; Hamaoka, 2013) and NIRS has provided important insights into the hemodynamic responses that occur during and in response to exercise (Hamaoka, 2013; Perrey & Ferrari, 2017).”
MethodKlusiewicz, A., Rębiś, K., Ozimek, M., & Czaplicki, A. (2021) · Biology of Sport · doi:10.5114/biolsport.2021.103571 · Cited by 24
Dunst, A. K., Manunzio, C., Feldmann, A., & Hesse, C. (2023) · Biology of Sport · doi:10.5114/biolsport.2023.122481 · Cited by 29
“…continuous-wave NIRS device was used (Moxy Monitor; Fortiori Designs LLC, MN, USA) to continuously mea - sure SmO 2 and tHb (total mass of haemoglobin and myoglobin) of the vastus lateralis muscle (VL), as this muscle has been used most commonly in recent studies using NIRS in cyclists [1].”
BackgroundMethodUsing a Portable Near-infrared Spectroscopy Device to Estimate The Second Ventilatory Threshold
Rodrigo-Carranza, V., González-Mohíno, F., Turner, A. P., Rodriguez-Barbero, S., & González-Ravé, J. M. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1343-2127 · Cited by 24
“Near-infrared spectroscopy (NIRS) has recently been used to determine total muscle oxygen saturation at rest and during exercise in a variety of anatomical positions and contexts [7, 8].”
MethodSeparate and combined effects of local and systemic hypoxia in resistance exercise
Girard, O., Willis, S. J., Purnelle, M., Scott, B. R., & Millet, G. P. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04217-3 · Cited by 29
Exercise intolerance in cystic fibrosis-the role of CFTR modulator therapies
Caterini, J. E., Ratjen, F. A., BARKER, A. R., Williams, C. A., Rendall, K., Schneiderman, J. E., & Wells, G. D. (2021) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2021.11.011 · Cited by 26
Relationship between EMG and fNIRS during Dynamic Movements
Daniel, N., Sybilski, K., Kaczmarek, W., Siemiaszko, D., & Małąchowski, J. (2023) · Sensors · doi:10.3390/s23115004 · Cited by 26
“fNIRS technology allows changes in muscle metabolism and muscle oxygenation to be observed during and after exercise or training interventions, both in the laboratory and during competition [13].”
BackgroundVasquez Bonilla, A., González-Custodio, A., Timón, R., Cardenosa, A., Camacho-Cardenosa, M., & Olcina, G. (2023) · Biology of Sport · doi:10.5114/biolsport.2023.114288 · Cited by 22
“Likewise, in the latest re - views on the use of NIRS as a research tool in sports settings, it has been shown that portable NIRS has good sensitivity to detect skeletal muscle oxygen supply and use during static and dynamic muscle work in response to interventions in exercise and training [8].”
Olcina, G. J., Pérez-Sousa, M. Á., Álvarez, J. A. E., & Timón, R. (2019) · Sports · doi:10.3390/sports7050115 · Cited by 31
“NIRS has been suggested as a sensitive measure to assess local muscle oxygen delivery and utilisation during dynamic muscle work in response to exercise and training [18].”
BackgroundClinical translation of biomedical sensors for sports medicine
Seshadri, D. R., Magliato, S. N., Voos, J. E., & Drummond, C. K. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1612474 · Cited by 24
“intense exercise leading to the production of lactic acid [79].”
BackgroundBriceño, F. A. C., Espinosa‐Ramírez, M., Moya-Gallardo, E., Fuentes-Kloss, R., Gabrielli, L., Araneda, O. F., & Viscor, G. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18168287 · Cited by 20
“Measurement of SmO2 During the protocol, muscle oxygen saturation (SmO2) was non-invasively evaluated using the monitor MOXY® (Fortiori Design LLC, Hutchinson, MN, USA), which emits light waves close to the infrared range (near-infrared spectroscopy, NIRS (630–850 nm)) from diodes to the surrounding tissue and records…”
MethodSendra‐Pérez, C., Priego‐Quesada, J. I., Palmer, R. S., Murias, J. M., & Martínez, A. E. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00420.2023 · Cited by 24
Side differences and reproducibility of the Moxy muscle oximeter during cycling in trained men
Skotzke, P., Schwindling, S., & Meyer, T. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05514-2 · Cited by 25
“Apart from lab-graded NIRS devices primarily developed to measure brain oxygenation, commercially available and less expensive portable NIRS devices dedicated to measure muscle oxygen allow the use in real-world settings and everyday training (Perrey and Ferrari 2018).”
BackgroundMethodIntroduction to the theme issue: Measuring physiology in free-living animals
Hawkes, L. A., Fahlman, A., & Sato, K. (2021) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2020.0210 · Cited by 21
Kriel, Y., Askew, C. D., & Solomon, C. (2018) · PeerJ · doi:10.7717/peerj.5026 · Cited by 18
“…recommendations for performing muscle NIRS measurements and NIRS data analysis are available (Ferrari, Muthalib & Quaresima, 2011; Grassi & Quaresima, 2016; Perrey & Ferrari, 2018), there is no accepted standard for the method of calculating, analysing and presenting individual and group NIRS data.”
BackgroundMethodContreras-Briceño, F., Espinosa-Ramirez, M., Keim-Bagnara, V., Carreño-Román, M., Rodríguez-Villagra, R., Villegas-Belmar, F., Viscor, G., Gabrielli, L., Andía, M. E., Araneda, O. F., et al. (2022) · Life · doi:10.3390/life12030444 · Cited by 17
“intercostales) were non-invasively assessed using the monitor MOXY® (Fortiori Design LLC, Hutchinso , MN, USA), which emits ligh waves close to the infrared range (NearInfrared Spectroscopy, NIRS (630–850 nm)) from diodes to the surrounding tissue and records total haemoglobin (THb) and myoglob n (mHb) concentrations…”
BackgroundMethodResultInfluentialMaterials and System Design for Self‐Decision Bioelectronic Systems
Zeng, Q., Liu, H., Zhang, Y., Zheng, Y., Ding, X., Zhu, M., Shi, G., Wang, Y., Haick, H., & Zhang, M. (2026) · Advanced Materials · doi:10.1002/adma.202521164 · Cited by 33
Manchado-Gobatto, F. D. B., Torres, R. S., Marostegan, A. B., Rasteiro, F. M., Hartz, C. S., Moreno, M. A., Pinto, A. D. S., & Gobatto, C. A. (2022) · Biology · doi:10.3390/biology11070963 · Cited by 17
“In these sections, the subjects were equipped with two NIRS devices (one in BB and the other in VL) to acquire muscle oxygenation signals and with the HR monitor.”
BackgroundResultInfluentialIntra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
Desanlis, J., Gordon, D. A., Calveyrac, C., Cottin, F., & Gernigon, M. (2022) · Sensors · doi:10.3390/s22145165 · Cited by 19
“By using NIRS-derived reoxygenation rate parameters, it is possible to differentiate between trained and untrained participants [8], as well as healthy participants and diseased patients [18].”
BackgroundMethodSendra-Pérez, C., Encarnacion-Martinez, A., Salvador-Palmer, R., Murias, J. M., & Priego-Quesada, J. I. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05593-1 · Cited by 16
“…in blood lactate concentrations or gas exchange data to interpret changes/ disruptions to metabolic homeostasis within the exercising muscles, the determination of breakpoints by NIRS allows for a more specific evaluation of the changes taking place within active muscles (Perrey & Ferrari 2018).”
Muscle oxygenation maintained during repeated-sprints despite inspiratory muscle loading
Rodriguez, R. F., Townsend, N., Aughey, R. J., & Billaut, F. (2019) · PLoS ONE · doi:10.1371/journal.pone.0222487 · Cited by 20
Espinosa‐Ramírez, M., Riquelme-Sánchez, S., Araya, F., Rodríguez, G., Figueroa-Martínez, F., Gabrielli, L., Viscor, G., Reid, W. D., & Briceño, F. A. C. (2023) · Biology · doi:10.3390/biology12020219 · Cited by 21
“vastus lateralis) [21] and recently in respiratory muscles (m.”
BackgroundThe effect of severe intensity bouts on muscle oxygen saturation responses in trained cyclists
Yogev, A., Arnold, J. I., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1086227 · Cited by 19
A Surface Electromyography (sEMG) System Applied for Grip Force Monitoring
Wu, D., Tian, P., Zhang, S., Wang, Q., Yu, K., Wang, Y., Gao, Z., Huang, L., Li, X., Zhai, X., et al. (2024) · Sensors · doi:10.3390/s24123818 · Cited by 17
Broadband absorption spectroscopy of heterogeneous biological tissue
Blaney, G. P., Curtsmith, P., Sassaroli, A., Fernandez, C. M., & Fantini, S. (2021) · Applied Optics · doi:10.1364/ao.431013 · Cited by 19
Dalamitros, A. A., Semaltianou, E., Toubekis, A. G., & Kabasakalis, A. (2021) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2021.759925 · Cited by 19
“Overall, NIRS method is presented as an appropriate solution for quick and continuous field-based evaluation in a variety of sports, thus, assessing both acute and chronic adaptations, while characterized by high sensitivity in different exercise demands and good reproducibility values (Perrey and Ferrari, 2018).”
MethodMiranda‐Fuentes, C., Guisado-Requena, I. M., Delgado‐Floody, P., Poblete, L. A., Pérez‐Castilla, A., Jerez‐Mayorga, D., & Ríos, L. J. C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17238824 · Cited by 21
“The result achieved will be the weighted average of hemoglobin oxygen saturations in the vascular bed (small arteries, arterioles, capillaries, venules and small veins) and the myoglobin heme group in muscle fibers [6].”
BackgroundInfluentialBehrendt, T., Bielitzki, R., Behrens, M., & Schega, L. (2023) · Physiology & Behavior · doi:10.1016/j.physbeh.2023.114217 · Cited by 16
Reinpõld, K., & Rannama, I. (2023) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk8020064 · Cited by 15
“Nevertheless, NIRS devices are not without limitations, which need to be addressed, such as adipose tissue thickness and other methodological considerations [17].”
BackgroundMethodInfluentialDellinger, J. R., Figueroa, A., & Gonzales, J. U. (2023) · Microvascular Research · doi:10.1016/j.mvr.2023.104569 · Cited by 14
Santarém, D., Machado, I., Sampaio, J. E., & Abrantes, C. G. (2023) · PLoS ONE · doi:10.1371/journal.pone.0281885 · Cited by 14
“Muscle oxygen saturation (SmO2) has been gaining emphasis as a local muscle measurement at rest and during exercise [12], not only in terms of sports performance [13] but also in terms of health [14, 15].”
BackgroundPerlet, M. R., Hosick, P. A., Licameli, N. M., & Matthews, E. L. (2024) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004873 · Cited by 13
“Near-infrared spectroscopy (NIRS) is commonly used in sport science to assess responses in skeletal muscle oxygen (SmO 2 ) and total heme (TH) (1,39).”
Rębiś, K., Sadowska, D., Starczewski, M., & Klusiewicz, A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.809864 · Cited by 12
“…few years, the introduction of mobile oximeters to measure the oxygenation level of myoglobin in the muscle cytoplasm and hemoglobin in the blood vessels of the muscle microcirculation (muscle oxygen saturation, SmO2) has been particularly relevant to training practice (Perrey and Ferrari, 2018).”
BackgroundGiminiani, R. D., Lancia, S., Ferrari, M., Quaresima, V., Vistisen, H. T., Kliltgaard, A., Heick, R. A., Oestergard, K., Soerensen, K. Y., & Cardinale, M. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438785 · Cited by 14
“Similar commercial oximeters (Portamon, Artinis, Netherlands; Moxy, Fortiori Design, LCC, USA) have been largely utilized successfully in sports science for similar applications[16], [17].”
BackgroundSelf-citationStuer, L., Teso, M., Colosio, A. L., Loi, M., Mucci, P., Pogliaghi, S., Boone, J., & Caen, K. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05654-5 · Cited by 13
“NIRS is therefore considered a valid tool for the functional evaluation of oxygenation at the level of tissues (Quaresima et al. 2003; Hamaoka et al. 2011; Ferrari et al. 2011; Grassi and Quaresima 2016; Hamaoka and McCully 2019; Perrey and Ferrari 2018; Neary 2004; Roldan and Kyriacou 2021).”
Dutta, A., Zhao, F., Cheung, M., Das, A., Tomita, M., & Chatterjee, K. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629721 · Cited by 11
“response during tip-toe exercise in young and healthy humans [3], as shown in Fig.”
MethodGasser, B. A., Franchi, M. V., Ruoss, S., Frei, A., Popp, W., Niederseer, D., Catuogno, S., Frey, W. O., & Flück, M. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.814975 · Cited by 12
“Furthermore, within our investigation, we also identify considerable reductions for the computed levels of oxygen saturation that are in line with the reported larger degrees for muscle deoxygenation and reoxygenation between the aerobically fit and unfit subjects (Brizendine et al., 2013; Perrey and Ferrari, 2018).”
BackgroundResultInfluentialGandía-Soriano, A., Salas-Montoro, J.-A., Javaloyes, A., Lorente-Casaus, C., Zabala, M., Priego‐Quesada, J. I., & Mateo‐March, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1828-8499 · Cited by 18
Zhong, Z., Dong, H., Wu, Y. Q., Zhou, S., Li, H., Huang, P., Tian, H., Li, X., Xiao, H., Yang, T., et al. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.950086 · Cited by 15
“SmO2 change can be used to evaluate oxygenation capacity and is correlated with exercise performance (Perrey and Ferrari, 2018; Feldmann et al., 2020).”
BackgroundPaulauskas, R., Nekriošius, R., Dadelienė, R., Sousa, A., & Figueira, B. (2022) · Sensors · doi:10.3390/s22218238 · Cited by 16
“For that reason, the popularity of the NIRS method in sports research and real-world scenarios has been growing in recent years [2].”
MethodUsher, A., & Babraj, J. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05305-1 · Cited by 11
Blaney, G. P., Sassaroli, A., & Fantini, S. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s3.s33313 · Cited by 12
“NIRS has been broadly applied to various human tissues, including the brain, 8 skeletal muscle, 9 and breast.”
Matzka, M., Zinner, C., Kunz, P., Holmberg, H., & Sperlich, B. (2021) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2019-0912 · Cited by 13
Frailty influences the vascular responsiveness of elderly individuals with chronic heart failure
Rech, D. A., da Silveira, L. S., Martins, E. M., Roque, A. B. A. D. O., Althoff, A., Maiorana, A., Vieira, A. M., & Karsten, M. (2022) · Microvascular Research · doi:10.1016/j.mvr.2022.104316 · Cited by 11
Vasquez-Bonilla, A. A., Rojas‐Valverde, D., Timón, R., & Olcina, G. J. (2022) · Apunts Sports Medicine · doi:10.1016/j.apunsm.2022.100395 · Cited by 18
Maliszewski, K., Feldmann, A., McCully, K. K., & Julian, R. (2024) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-024-00809-5 · Cited by 13
“Perrey & Ferrari [21] previously conducted a systematic review on muscle oximetry in sports science, presenting the development of the application of oximetry in sports during the past 35 years.”
BackgroundResultInfluentialDesanlis, J., Gordon, D. A., French, C., Calveyrac, C., Cottin, F., & Gernigon, M. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1441239 · Cited by 11
“NIRS provides non-invasive estimations of haemoglobin concentration changes, giving information on muscular tissue oxygenation (Ferrari et al., 2011; Perrey and Ferrari, 2018).”
BackgroundMethodCortese, L., Esteberena, P. F., Zanoletti, M., Presti, G. L., Velazquez, G. B. A., Ruiz, S., Buttafava, M., Renna, M., Sieno, L. D., Tosi, A., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad133a · Cited by 10
“…et al. 2016, Katayama et al. 2015, Rodrigues et al. 2020, Reid et al. 2016, Guenette et al. 2011, Shadgan et al. 2011, Tanaka et al. 2018, Istfan et al. 2021, Perrey & Ferrari 2018, Quaresima et al. 2019, Giovannella et al. 2021, Yu et al. 2005, Gurley et al. 2012, Shang et al. 2013).”
BackgroundSendra-Pérez, C., Encarnación-Martínez, A., Oficial-Casado, F., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad1457 · Cited by 9
Reliability of near-infrared spectroscopy in measuring muscle oxygenation during squat exercise
Corral‐Pérez, J., Marín-Galindo, A., Costilla, M., Casals, C., Muñoz‐López, A., Sixto, A. S., Sañudo, B., & Ponce‐González, J. G. (2024) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2024.07.006 · Cited by 14
Kamandulis, S., Werasirirat, P., Namsawang, J., Ubolnuar, N., Sniečkus, A., & Muanjai, P. (2024) · Journal of Human Kinetics · doi:10.5114/jhk/187026 · Cited by 10
“The increase in SmO 2 implies that the oxygen supply exceeded the oxygen demand within the muscle (Perrey and Ferrari, 2018), which may be indicative of the favorable facilitation effect of the warm-up.”
BackgroundMuscular and Prefrontal Cortex Activity during Dual-Task Performing in Young Adults
Saraiva, M., Castro, M. A., & Vilas‐Boas, J. P. (2023) · European Journal of Investigation in Health Psychology and Education · doi:10.3390/ejihpe13040055 · Cited by 15
“Furthermore, fNIRS can also be used to investigate muscle physiology, evaluating oxidative skeletal muscle performance [50].”
BackgroundRaberin, A., Méric, H., Mucci, P., Ayerbe, J. L., & Durand, F. (2019) · European Journal of Sport Science · doi:10.1080/17461391.2019.1669717 · Cited by 12
Gasser, B. A., Frei, A., Niederseer, D., Catuogno, S., Frey, W. O., & Flück, M. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.814974 · Cited by 10
“To come over this limiting fact, we carried out the ramp exercise in the mere absence of a warm-up, respectively no activation ofmitochondrial respiration, nevertheless some bias remains (Nioka et al., 1998; Boone et al., 2012; Perrey and Ferrari, 2018).”
BackgroundMethodEfforts toward the continuous monitoring of molecular markers of performance
Flatebo, C., Conkright, W. R., Beckner, M. E., Batchelor, R. H., Kippin, T. E., Heikenfeld, J. C., & Plaxco, K. W. (2023) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2023.01.010 · Cited by 8
“1 By providing real-time information on blood sugar levels, wearable continuous glucose monitors have similarly revolutionized the treatment of diabetes, and are making rapid inroads into performance monitoring.”
Reinpõld, K., Rannama, I., & Port, K. (2024) · Sports · doi:10.3390/sports12020040 · Cited by 8
“The wearable industry is stepping rapidly forward, and one of the applications, among other performance-related technologies, is portable NIRS [3].”
BackgroundCalculating Load and Intensity Using Muscle Oxygen Saturation Data
Vasquez-Bonilla, A. A., Sepulveda, R. A. Y., Gómez‐Carmona, C. D., Olcina, G. J., Arancibia, J. E. O., & Rojas‐Valverde, D. (2024) · Sports · doi:10.3390/sports12040113 · Cited by 10
“…criteria based on muscle oxygen physiology ; Fitness coaches and strength and conditioning trainers can Finally, as stated by Perrey and Ferrari [13], SmO 2 is characterized by faster feedback 2 a more precise parameter than HR, which underestimates the internal response in short duration and…”
BackgroundMethodJeskanen, T., Ylinen, V. P., Valtonen, R. I. P., & Tulppo, M. P. (2024) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12886 · Cited by 13
“In addition, NIRS has been utilized to study athletes' oxygen levels and exercise responses (Perrey & Ferrari, 2018).”
Metadata
- Authors
- Perrey, S., & Ferrari, M.
- Affiliations
- University of L'Aquila (IT)
- Venue
- Sports Medicine
- Published
- 2017-11-25
- Volume
- 48
- Issue
- 3
- Pages
- 597-616
- ISSN
- 0112-1642 (ISSN-L)
- 1179-2035
- OpenAlex
- W2770126250
- Semantic Scholar
- 29269d1dace5bdee7b1774aca037386a7492a619
- Cited by
- 220
- References
- 95
- Citations by year
- 2026: 17 · 2025: 18 · 2024: 40 · 2023: 38 · 2022: 36 · 2021: 27 · 2020: 13 · 2019: 17 · 2018: 14
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- public-domain
- www.springer.com/tdm (unspecified)
- Locations
- Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion, public-domain)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- near-infrared spectroscopy, muscle oxygenation, skeletal muscle metabolism, oxidative capacity, exercise training, athletic performance, athletes
- MeSH terms
- Adolescent, Adult, Exercise Test, Heart Rate, Humans, Infant, Newborn, Male, Oximetry, Oxygen, Oxygen Consumption, Running, Sports, Exercise, Muscle, Skeletal, Hand Strength, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.