Histopathologic evaluation of prolonged intracortical electrical stimulation
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Cell Damage in the Brain: A Speculative Synthesis
Siesjö, B. K. (1981) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1981.18 · Cited by 1,815
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227
Histological Evaluation of Neural Damage from Electrical Stimulation
Yuen, T. G. H., Agnew, W. F., Bullara, L. A., Jacques, S., & McCreery, D. B. (1981) · Neurosurgery · doi:10.1097/00006123-198109000-00013 · Cited by 160
Self-citationElectrical stimulation of the brain. III. The neural damage model.
Pudenz, R. H., Bullara, L. A., Jacques, S., & Hambrecht, F. T. (1975) · PubMed · Cited by 145
Self-citationRobblee, L. S., McHardy, J., Agnew, W. F., & Bullara, L. A. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90062-6 · Cited by 104
Self-citationTissue reactions to long-term electrical stimulation of the cerebellum in monkeys
Brown, W. J., Babb, T. L., Soper, H. V., Lieb, J. P., Ottino, C. A., & Crandall, P. H. (1977) · Journal of Neurosurgery · doi:10.3171/jns.1977.47.3.0366 · Cited by 98
Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (1983) · Experimental Neurology · doi:10.1016/0014-4886(83)90221-2 · Cited by 96
Self-citationElectrical stimulation of the brain. II. Effects on the blood-brain barrier.
Pudenz, R. H., Bullara, L. A., Dru, D., & Talalla, A. (1975) · PubMed · Cited by 83
Self-citationNeuronal activity evoked by chronically implanted intracortical microelectrodes
McCreery, D. B., Bullara, L. A., & Agnew, W. F. (1986) · Experimental Neurology · doi:10.1016/0014-4886(86)90131-7 · Cited by 75
Self-citation
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
“…response to chronically implanted electrodes is the presence of an encapsulating layer of reactive astrocytes surrounding the implant interface (Agnew et al., 1986; Carter and Houk, 1993; Edell et al., 1992; McCreery et al., 1997; Schmidt et al., 1976, 1993; Schultz and Willey, 1976; Szarowski…”
BackgroundResultBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Self-citationCerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
“…also found that the charge-density threshold for producing histological damage was lower when surface electrodes were used (Bernstein et al., 1977; Pudenz et al., 1975, 1977; Yuen et al., 1981; Robblee et al., 1983), than when depth electrodes were used (Agnew et al., 1986; McCreery et al., 1986).”
BackgroundMethodRetinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 341
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Chronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 262
Mapping Cortical Activity Elicited with Electrical Microstimulation Using fMRI in the Macaque
Tolias, A. S., Sultan, F., Augath, M., Oeltermann, A., Tehovnik, E. J., Schiller, P. H., & Logothetis, N. K. (2005) · Neuron · doi:10.1016/j.neuron.2005.11.034 · Cited by 250
“By contrast, platinum90-iridium10 has a lower corrosion value, which makes it less suitable for electrical microstimulation (Brummer et al., 1983; Agnew et al., 1986).”
BackgroundOver-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Self-citationWinslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Nolta, N. F., Christensen, M. B., Crane, P. D., Skousen, J. L., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.081 · Cited by 175
“This type of surface cavity has beenobserved at timepoints as short as sevendays [46] andas long asmultiple years [5],with a depth similar towhatwe observed in this study, althoughwith a shapemore closely matching the rectangular microelectrode array's base.”
A model for intracortical visual prosthesis research
Troyk, P., Bak, M., Berg, J., Bradley, D., Cogan, S., Erickson, R., Kufta, C., McCreery, D., Schmidt, E., & Towle, V. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07308.x · Cited by 166
“) in 1979 in which the feasibility of chronic intracortical stimulation of the sensorimotor cortex was established (19,20).”
BackgroundSelf-citationStimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wachtler, T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 161
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Mailley, S. C., Hyland, M., Mailley, P., McLaughlin, J. M., & McAdams, E. T. (2002) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(02)00098-x · Cited by 84
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1994) · Hearing Research · doi:10.1016/0378-5955(94)90258-5 · Cited by 80
Self-citationPostmortem investigation of a human cortical visual prosthesis that was implanted for 36 years
Towle, V. L., Pytel, P., Lane, F., Plass, J., Frim, D. M., & Troyk, P. R. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9d11 · Cited by 11
Metadata
- Authors
- Agnew, W. F., Yuen, T. G. H., McCreery, D. B., & Bullara, L. A.
- Venue
- Experimental Neurology
- Publisher
- Elsevier BV
- Published
- 1986-04
- Volume
- 92
- Issue
- 1
- Pages
- 162-185
- ISSN
- 0014-4886 (ISSN-L)
- OpenAlex
- W1988867892
- Cited by
- 173
- References
- 19
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.