A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastic properties of reinforced solids: Some theoretical principles
Hill, R. (1963) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(63)90036-x · Cited by 4,918
Non-Homogeneous Media and Vibration Theory
(1980) · Lecture Notes in Physics · doi:10.1007/3-540-10000-8 · Cited by 3,637
Analysis of Composite Materials—A Survey
Hashin, Z. (1983) · Journal of Applied Mechanics · doi:10.1115/1.3167081 · Cited by 2,405
Parfitt, A. M., Mathews, C. H., Villanueva, A. R., Kleerekoper, M., Frame, B., & Rao, D. S. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111096 · Cited by 1,545
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Kleerekoper, M., Villanueva, A. R., Stanciu, J., Rao, D. S., & Parfitt, A. M. (1985) · Calcified Tissue International · doi:10.1007/bf02554913 · Cited by 695
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718
Pistoia, W., van Rietbergen, B., Lochmüller, E.-M., Lill, C. A., Eckstein, F., & Rüegsegger, P. (2002) · Bone · doi:10.1016/s8756-3282(02)00736-6 · Cited by 643
MacNeil, J. A., & Boyd, S. K. (2008) · Bone · doi:10.1016/j.bone.2008.01.017 · Cited by 440
Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431
Scaffold Design and Manufacturing: From Concept to Clinic
Hollister, S. J. (2009) · Advanced Materials · doi:10.1002/adma.200802977 · Cited by 408
Self-citationMacNeil, J. A., & Boyd, S. K. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.002 · Cited by 386
Lin, C. Y., Kikuchi, N., & Hollister, S. J. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.029 · Cited by 384
Self-citationSystematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Silva, M. J., & Gibson, L. J. (1997) · Bone · doi:10.1016/s8756-3282(97)00100-2 · Cited by 355
Silva, M. J., Hayes, W. C., & Gibson, L. J. (1995) · International Journal of Mechanical Sciences · doi:10.1016/0020-7403(94)00018-f · Cited by 336
Fritsch, A., & Hellmich, C. (2007) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2006.09.013 · Cited by 321
Adachi, T., Osako, Y., Tanaka, M., Hojo, M., & Hollister, S. J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.02.039 · Cited by 316
Self-citationRubin, C., Turner, A. S., Mallinckrodt, C., Jerome, C., Mcleod, K., & Bain, S. (2002) · Bone · doi:10.1016/s8756-3282(01)00689-5 · Cited by 316
Single Cell Mechanotransduction and Its Modulation Analyzed by Atomic Force Microscope Indentation
Charras, G. T., & Horton, M. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75638-5 · Cited by 281
Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques
Ulrich, D., van Rietbergen, B., Weinans, H., & Rüegsegger, P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00118-3 · Cited by 279
Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur
Van Rietbergen, B., Huiskes, R., Eckstein, F., & Rüegsegger, P. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.10.1781 · Cited by 256
Finite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255
Computational Modeling of Ligament Mechanics
Weiss, J. A., & Gardiner, J. C. (2001) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v29.i3.20 · Cited by 244
Kivell, T. L. (2016) · Journal of Anatomy · doi:10.1111/joa.12446 · Cited by 239
“…has been used successfully in various ways to quantify and validate the mechanical properties and functional significance of trabecular bone (Hollister et al. 1994; van Rietbergen et al. 1995, 1999; Kabel et al. 1999; Ulrich et al. 1999; Homminga et al. 2004; Ryan & van Rietbergen, 2005;…”
MethodLiu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., Bevill, G., Keaveny, T. M., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.071009 · Cited by 239
“Using an element-by-element preconditioned conjugate gradient solver,((26)) six FEAs were performed for each model, representing three uniaxial compression tests along three imaging axes (x, y, and z) and three uniaxial shear tests.”
MethodLiu, X. S., Zhang, X. H., Sekhon, K. K., Adams, M. F., McMahon, D. J., Bilezikian, J. P., Shane, E., & Guo, X. E. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090822 · Cited by 231
“Using a customized element-byelement preconditioned conjugate gradient solver,((43)) six mFE analyses were performed for each model, representing three uniaxial compression tests along three imaging axes (x, y, and z) and three uniaxial shear tests.”
MethodScaffold Translation: Barriers Between Concept and Clinic
Hollister, S. J., & Murphy, W. L. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0251 · Cited by 224
“Homogenization theory 42,43 has been adopted by our group 44,45 and others 46,47 to compute effective scaffold and biologic tissue properties directly from 3D hierarchical morphology and scaffold architecture.”
Self-citationChandran, P. L., & Barocas, V. H. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2165699 · Cited by 214
Liu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., & Guo, X. E. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060716 · Cited by 207
“For each model, a linear FE analysis was applied to determine the apparent Young’s modulus E* using an element-by-element preconditioned conjugate gradient solver.((36)) The trabecular bone tissue was modeled as an isotropic, linear elastic material with a Young’s modulus Es of 15 GPa and a Poisson’s ratio of 0.”
MethodHuman vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S. M., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 197
“technology in three-dimensional imaging and computer hardware, it has become possible to estimate the stiffness of cancellous bone using large-scale finite element (LSFE) models at both the apparent and trabecular levels (Edidin et al., 1993; Fyhrie et al., 1992; Fyhrie and Hou, 1995a, b; Hollister and Riemer, 1993; H…”
BackgroundMechanical stress determines the configuration of TGFβ activation in articular cartilage
Zhen, G., Guo, Q., Li, Y., Wu, C., Zhu, S., Wang, R., Guo, X. E., Kim, B. C., Huang, J., Hu, Y., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-21948-0 · Cited by 189
Guo, X. E., & Kim, C. H. (2002) · Bone · doi:10.1016/s8756-3282(01)00673-1 · Cited by 180
Shefelbine, S. J., Simon, U., Claes, L., Gold, A., Gabet, Y., Bab, I., Müller, R., & Augat, P. (2005) · Bone · doi:10.1016/j.bone.2004.11.007 · Cited by 179
“Previous studies have used structural parameters [22] or finite element models [14] of unfractured trabecular bone to predict bone stiffness and obtained correlation coefficients with experimental measurements from 0.”
BackgroundMethodFinite Element Method (FEM), Mechanobiology and Biomimetic Scaffolds in Bone Tissue Engineering
Boccaccio, A., Ballini, A., Pappalettere, C., Tullo, D., Cantore, S., & Desiate, A. (2011) · International Journal of Biological Sciences · doi:10.7150/ijbs.7.112 · Cited by 178
Homminga, J., McCreadie, B. R., Ciarelli, T. E., Weinans, H., Goldstein, S. A., & Huiskes, R. (2002) · Bone · doi:10.1016/s8756-3282(02)00693-2 · Cited by 177
Cohen, A., Dempster, D. W., Müller, R., Guo, X. E., Nickolas, T. L., Liu, X. S., Zhang, X. H., Wirth, A. J., van Lenthe, G. H., Kohler, T., et al. (2010) · Osteoporosis International · doi:10.1007/s00198-009-0945-7 · Cited by 175
“Six μFE analyses, representing three uniaxial compressions and three uniaxial shears, were performed on each model using an element-byelement precondition conjugate gradient solver [19, 49].”
MethodStauber, M., & Müller, R. (2006) · Bone · doi:10.1016/j.bone.2005.09.019 · Cited by 174
“Using finite element models, the apparent stiffness, which is an important inherent attribute of trabecular bone samples, can be computed directly and very accurately [13,50].”
BackgroundVan Rietbergen, B., Müller, R., Ulrich, D., Rüegsegger, P., & Huiskes, R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00150-x · Cited by 170
“…studies, a homogenization sampling procedure, incorporating large-scale FE-models representing small samples of trabecular bone in detail, was applied to obtain the trabecular tissue stresses throughout larger pieces of bones or whole joints (Hollister et al., 1993; Hollister and Goldstein, 1993).”
MethodTsubota, K.-I., Suzuki, Y., Yamada, T., Hojo, M., Makinouchi, A., & Adachi, T. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.02.030 · Cited by 165
A Global Relationship Between Trabecular Bone Morphology and Homogenized Elastic Properties
Zysset, P. K., Goulet, R. W., & Hollister, S. J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834756 · Cited by 105
Self-citationZhang, X. H., Liu, X. S., Vasilic, B., Wehrli, F. W., Benito, M., Rajapakse, C. S., Snyder, P. J., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080405 · Cited by 79
Damage in trabecular bone at small strains
Morgan, E., Yeh, O., & Keaveny, T. (2005) · European Journal of Morphology · doi:10.1080/09243860500095273 · Cited by 59
Shi, X., Sherry Liu, X., Wang, X., Edward Guo, X., & Niebur, G. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.05.032 · Cited by 45
“N IH -PA Author M anuscript N IH -PA Author M anuscript N IH -PA Author M anuscript Microstructural finite element models were created for each specimen by directly converting bone voxels into eight-node finite elements (Hollister et al., 1994).”
Method
Metadata
- Authors
- Hollister, S. J., Brennan, J. M., & Kikuchi, N.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1994-04
- Volume
- 27
- Issue
- 4
- Pages
- 433-444
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2019404921
- Cited by
- 322
- References
- 30
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.