The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A novel 3D paper-based microfluidic electrochemical glucose biosensor based on rGO-TEPA/PB sensitive film
Abstract
A novel 3D paper-based microfluidic screen-printed electrode (SPE) composed of two layers was constructed by photolithography and screen-printing technology. Aldehyde functionalized hydrophilic zone of the counter and reference electrodes layer was prepared for glucose oxidase immobilization. Highly conductive prussian blue deposited reduced graphene oxide-tetraethylene pentamine (rGO-TEPA/PB) modified paper working electrode layer can be used as an electrochemical sensitive membrane for quantitative detection of hydrogen peroxide (H2O2), which was the enzyme-catalyzed reaction product. Therefore, this 3D paper-based microfluidic electrochemical biosensor can be used for quantitative detection of glucose. Under optimum conditions, the proposed biosensor can be used for quantitative determination of glucose over a wide linear range of 0.1 mM-25 mM with detection limit of 25 μM. Finally, the 3D paper-based microfluidic electrochemical biosensor was applied to determine glucose in human sweat and blood, and the obtained results were in good consistency with values measured by Roche's blood glucose meter. In addition, the proposed 3D paper-based electrochemical device showed good repeatability, stability, and anti-interference, which would be of great potential to monitor glucose in complex biological fluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.058 · Cited by 348
Munje, R. D., Muthukumar, S., & Prasad, S. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.07.088 · Cited by 190
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Smartphone based non-invasive salivary glucose biosensor
Soni, A., & Jha, S. K. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.10.003 · Cited by 143
Cited by
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Li, S., Zhang, H., Zhu, M., Kuang, Z., Li, X., Xu, F., Miao, S., Zhang, Z., Lou, X., Li, H., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00759 · Cited by 309
Recent advances in flexible sweat glucose biosensors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac14ef · Cited by 40
Metadata
- Authors
- Cao, L., Han, G.-C., Xiao, H., Chen, Z., & Fang, C.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 1096
- Pages
- 34-43
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2981931690
- Cited by
- 160
- References
- 8
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.