The DOI matches its Crossref record; 259 of the 259 references it cites were found in a registry or an index.
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Open accessAbstract
Microfluidics is an emerging and promising interdisciplinary technology which offers powerful platforms for precise production of novel functional materials (e.g., emulsion droplets, microcapsules, and nanoparticles as drug delivery vehicles- and drug molecules) as well as high-throughput analyses (e.g., bioassays, detection, and diagnostics). In particular, multiphase microfluidics is a rapidly growing technology and has beneficial applications in various fields including biomedicals, chemicals, and foods. In this review, we first describe the fundamentals and latest developments in multiphase microfluidics for producing biocompatible materials that are precisely controlled in size, shape, internal morphology and composition. We next describe some microfluidic applications that synthesize drug molecules, handle biological substances and biological units, and imitate biological organs. We also highlight and discuss design, applications and scale up of droplet- and flow-based microfluidic devices used for drug discovery and delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review
Maeda, H., Wu, J., Sawa, T., Matsumura, Y., & Hori, K. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00248-5 · Cited by 6,565
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Rayleigh, L. (1878) · Proceedings of the London Mathematical Society · doi:10.1112/plms/s1-10.1.4 · Cited by 3,064
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Cited by
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Droplets and Bubbles in Microfluidic Devices
Anna, S. L. (2016) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122414-034425 · Cited by 582
PEG-PCL-based nanomedicines: A biodegradable drug delivery system and its application
Grossen, P., Witzigmann, D., Sieber, S., & Huwyler, J. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.05.028 · Cited by 496
Nanomedicine scale-up technologies: feasibilities and challenges
Paliwal, R., Babu, R. J., & Palakurthi, S. (2014) · AAPS PharmSciTech · doi:10.1208/s12249-014-0177-9 · Cited by 466
The Future of Pharmaceutical Manufacturing Sciences
Rantanen, J., & Khinast, J. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24594 · Cited by 442
Recent advances of controlled drug delivery using microfluidic platforms
Sanjay, S. T., Zhou, W., Dou, M., Tavakoli, H., Ma, L., Xu, F., & Li, X. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.09.013 · Cited by 365
Customizing poly(lactic-co-glycolic acid) particles for biomedical applications
Swider, E., Koshkina, O., Tel, J., Cruz, L. J., de Vries, I. J. M., & Srinivas, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.04.006 · Cited by 328
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
A review on microreactors: Reactor fabrication, design, and cutting-edge applications
Suryawanshi, P. L., Gumfekar, S. P., Bhanvase, B. A., Sonawane, S. H., & Pimplapure, M. S. (2018) · Chemical Engineering Science · doi:10.1016/j.ces.2018.03.026 · Cited by 305
Reactions and Polymerizations at the Liquid–Liquid Interface
Piradashvili, K., Alexandrino, E. M., Wurm, F. R., & Landfester, K. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00567 · Cited by 279
Microfluidic-assisted fabrication of carriers for controlled drug delivery
Liu, D., Zhang, H., Fontana, F., Hirvonen, J. T., & Santos, H. A. (2017) · Lab on a Chip · doi:10.1039/c7lc00242d · Cited by 254
Application of flash nanoprecipitation to fabricate poorly water-soluble drug nanoparticles
Tao, J., Chow, S. F., & Zheng, Y. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2018.11.001 · Cited by 232
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
A review of microfluidic approaches for investigating cancer extravasation during metastasis
Ma, Y.-H. V., Middleton, K., You, L., & Sun, Y. (2018) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.104 · Cited by 154
Testing Lab-on-a-Chip Technology for Culturing Human Melanoma Cells under Simulated Microgravity
Przystupski, D., Górska, A., Michel, O., Podwin, A., Śniadek, P., Łapczyński, R., Saczko, J., & Kulbacka, J. (2021) · Cancers · doi:10.3390/cancers13030402 · Cited by 29
Bhujel, R., Maharjan, R., Kim, N. A., & Jeong, S. H. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.102608 · Cited by 26
Metadata
- Authors
- Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 65
- Issue
- 11-12
- Pages
- 1626-1663
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2071680657
- Cited by
- 313
- References
- 259
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.