Load shifting of nuclear power plants using cryogenic energy storage technology
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
To balance the demand and supply at off-peak hours, nuclear power plants often have to be down-regulated particularly when the installations exceed the base load requirements. Part-load operations not only increase the electricity cost but also impose a detrimental effect on the safety and life-time of the nuclear power plants. We propose a novel solution by integrating nuclear power generation with cryogenic energy storage (CES) technology to achieve an effective time shift of the electrical power output. CES stores excess electricity in the form of cryogen (liquid air/nitrogen) through an air liquefaction process at off-peak hours and recover the stored power by expanding the cryogen at peak hours. The combination of nuclear power generation and the CES technologies provides an efficient way to use thermal energy of nuclear power plants in the power extraction process, delivering around three times the rated electrical power of the nuclear power plant at peak hours, thus effectively shaving the peak. Simulations are carried out on the proposed process, which show that the round trip efficiency of the CES is higher than 70% due to the elevated topping temperature in the superheating process and thermal efficiency is also substantially increased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in electrical energy storage system: a critical review
Chen, H., Cong, T. N., Yang, W., Tan, C., Li, Y., & Ding, Y. (2009) · Progress in Natural Science · doi:10.1016/j.pnsc.2008.07.014 · Cited by 3,746
Self-citationStorage of electrical energy using supercritical liquid air
Smith, E. M. (1977) · Proceedings of the Institution of Mechanical Engineers · doi:10.1243/pime_proc_1977_191_035_02 · Cited by 176 · cited 1×
“The concept of CES was first proposed by University of Newcastle upon Tyne (UK) in 1977 as an alternative to compressed air energy storage (CAES) technology for peak shaving in an electricity grid [16].”
BackgroundSimulation of heat transfer in the cool storage unit of a liquid–air energy storage system
Araki, H., Nakabaru, M., & Chino, K. (2002) · Heat Transfer—Asian Research · doi:10.1002/htj.10035 · Cited by 26
Cited by
Electrical energy storage systems: A comparative life cycle cost analysis
Zakeri, B., & Syri, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.011 · Cited by 1,861
A review on compressed air energy storage: Basic principles, past milestones and recent developments
Budt, M., Wolf, D., Span, R., & Yan, J. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.02.108 · Cited by 1,185
Critical review of energy storage systems
Olabi, A. G., Onumaegbu, C., Wilberforce, T., Ramadan, M., Abdelkareem, M. A., & Al – Alami, A. H. (2021) · Energy · doi:10.1016/j.energy.2020.118987 · Cited by 793
Carnot battery technology: A state-of-the-art review
Dumont, O., Frate, G. F., Pillai, A., Lecompte, S., De paepe, M., & Lemort, V. (2020) · Journal of Energy Storage · doi:10.1016/j.est.2020.101756 · Cited by 448
A review of pumped hydro energy storage development in significant international electricity markets
Barbour, E., Wilson, I. A. G., Radcliffe, J., Ding, Y., & Li, Y. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.019 · Cited by 421
Self-citationUnderstanding the development trends of low-carbon energy technologies: A patent analysis
Albino, V., Ardito, L., Dangelico, R. M., & Messeni Petruzzelli, A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.08.012 · Cited by 390
Thermodynamic analysis of a liquid air energy storage system
Guizzi, G. L., Manno, M., Tolomei, L. M., & Vitali, R. M. (2015) · Energy · doi:10.1016/j.energy.2015.10.030 · Cited by 325
“The 103 cold fluids considered in this paper are the same as in [15], i.”
BackgroundMethodInfluentialShe, X., Peng, X., Nie, B., Leng, G., Zhang, X., Weng, L., Tong, L., Zheng, L., Wang, L., & Ding, Y. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.09.102 · Cited by 264
Self-citationNabat, M. H., Zeynalian, M., Razmi, A. R., Arabkoohsar, A., & Soltani, M. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.113486 · Cited by 245
Vecchi, A., Knobloch, K., Liang, T., Kildahl, H., Sciacovelli, A., Engelbrecht, K., Li, Y., & Ding, Y. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.105782 · Cited by 215
Self-citationA review on liquid air energy storage: History, state of the art and recent developments
Borri, E., Tafone, A., Romagnoli, A., & Comodi, G. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110572 · Cited by 210
Peng, X., She, X., Cong, L., Zhang, T., Li, C., Li, Y., Wang, L., Tong, L., & Ding, Y. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.03.151 · Cited by 195
Self-citationA review of marine renewable energy storage
Wang, Z., Carriveau, R., Ting, D. S. ‐., Xiong, W., & Wang, Z. (2019) · International Journal of Energy Research · doi:10.1002/er.4444 · Cited by 195
Damak, C., Leducq, D., Hoang, H. M., Negro, D., & Delahaye, A. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2019.11.009 · Cited by 175
She, X., Zhang, T., Cong, L., Peng, X., Li, C., Luo, Y., & Ding, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113355 · Cited by 174
Self-citationLiquid air energy storage flexibly coupled with LNG regasification for improving air liquefaction
Peng, X., She, X., Li, C., Luo, Y., Zhang, T., Li, Y., & Ding, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.05.040 · Cited by 173
Self-citationEnergy storage for grid-scale applications: Technology review and economic feasibility analysis
Frate, G. F., Ferrari, L., & Desideri, U. (2021) · Renewable Energy · doi:10.1016/j.renene.2020.10.070 · Cited by 170
A study on performance of a liquid air energy storage system with packed bed units
Peng, H., Shan, X., Yang, Y., & Ling, X. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.11.045 · Cited by 169
Zhang, T., Chen, L., Zhang, X., Mei, S., Xue, X., & Zhou, Y. (2018) · Energy · doi:10.1016/j.energy.2018.05.041 · Cited by 166
Liquid air energy storage: potential and challenges of hybrid power plants
Antonelli, M., Barsali, S., Desideri, U., Giglioli, R., Paganucci, F., & Pasini, G. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.11.091 · Cited by 155
Kim, J., Noh, Y., & Chang, D. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.092 · Cited by 146
Borri, E., Tafone, A., Romagnoli, A., & Comodi, G. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.03.079 · Cited by 108
Tafone, A., Borri, E., Comodi, G., van den Broek, M., & Romagnoli, A. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.06.133 · Cited by 104
Lee, I., Park, J., You, F., & Moon, I. (2019) · Energy · doi:10.1016/j.energy.2019.02.047 · Cited by 96
Cryogenics-based energy storage: Evaluation of cold exergy recovery cycles
Hamdy, S., Morosuk, T., & Tsatsaronis, G. (2017) · Energy · doi:10.1016/j.energy.2017.07.118 · Cited by 89
Performance evaluation of various cryogenic energy storage systems
Abdo, R. F., Pedro, H. T. C., Koury, R. N. N., Machado, L., Coimbra, C. F. M., & Porto, M. P. (2015) · Energy · doi:10.1016/j.energy.2015.08.008 · Cited by 87
Tafone, A., Romagnoli, A., Borri, E., & Comodi, G. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.04.171 · Cited by 82
Park, J., Lee, I., You, F., & Moon, I. (2019) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.9b00179 · Cited by 74
Exergy-Based and Economic Evaluation of Liquefaction Processes for Cryogenics Energy Storage
Hamdy, S., Moser, F., Morosuk, T., & Tsatsaronis, G. (2019) · Energies · doi:10.3390/en12030493 · Cited by 65
“The total revenue requirement (TRR) method was applied [22].”
BackgroundMethodHüttermann, L., & Span, R. (2019) · Energy · doi:10.1016/j.energy.2019.02.149 · Cited by 59
Liquid air energy storage – from theory to demonstration
Morgan, R. E. (2016) · International Journal of Environmental Studies · doi:10.1080/00207233.2016.1189741 · Cited by 22
“Looking further into the potential of integrating LAES into the energy system, Li proposed the integration of a LAES cycle with a nuclear facility to facilitate load following [18].”
Background
Metadata
- Authors
- Li, Y., Cao, H., Wang, S., Jin, Y., Li, D., Wang, X., & Ding, Y.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 113
- Pages
- 1710-1716
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2076843510
- Cited by
- 242
- References
- 3
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.