Continuous blood pressure measurement from one-channel electrocardiogram signal using deep-learning techniques
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Continuous blood pressure (BP) measurement is crucial for reliable and timely hypertension detection. State-of-the-art continuous BP measurement methods based on pulse transit time or multiple parameters require simultaneous electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Compared with PPG signals, ECG signals are easy to collect using wearable devices. This study examined a novel continuous BP estimation approach using one-channel ECG signals for unobtrusive BP monitoring. A BP model is developed based on the fusion of a residual network and long short-term memory to obtain the spatial-temporal information of ECG signals. The public multiparameter intelligent monitoring waveform database, which contains ECG, PPG, and invasive BP data of patients in intensive care units, is used to develop and verify the model. Experimental results demonstrated that the proposed approach exhibited an estimation error of 0.07 ± 7.77 mmHg for mean arterial pressure (MAP) and 0.01 ± 6.29 for diastolic BP (DBP), which comply with the Association for the Advancement of Medical Instrumentation standard. According to the British Hypertension Society standards, the results achieved grade A for MAP and DBP estimation and grade B for systolic BP (SBP) estimation. Furthermore, we verified the model with an independent dataset for arrhythmia patients. The experimental results exhibited an estimation error of -0.22 ± 5.82 mmHg, -0.57 ± 4.39 mmHg, and -0.75 ± 5.62 mmHg for SBP, MAP, and DBP measurements, respectively. These results indicate the feasibility of estimating BP by using a one-channel ECG signal, thus enabling continuous BP measurement for ubiquitous health care applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Long short-term memory recurrent neural network architectures for large scale acoustic modeling
Sak, H., Senior, A., & Beaufays, F. (2014) · Interspeech 2014 · doi:10.21437/interspeech.2014-80 · Cited by 2,973
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Lu, J., Lu, Y., Wang, X., Li, X., Linderman, G. C., Wu, C., Cheng, X., Mu, L., Zhang, H., Liu, J., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32478-9 · Cited by 1,133
Self-citationToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
A wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418
Cited by
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Machine Learning for Healthcare Wearable Devices: The Big Picture
Sabry, F., Eltaras, T., Labda, W., Alzoubi, K., & Malluhi, Q. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/4653923 · Cited by 321
AI-Assisted Detection of Biomarkers by Sensors and Biosensors for Early Diagnosis and Monitoring
Wasilewski, T., Kamysz, W., & Gębicki, J. (2024) · Biosensors · doi:10.3390/bios14070356 · Cited by 290
PPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms
Ibtehaz, N., Mahmud, S., Chowdhury, M. E. H., Khandakar, A., Salman Khan, M., Ayari, M. A., Tahir, A. M., & Rahman, M. S. (2022) · Bioengineering · doi:10.3390/bioengineering9110692 · Cited by 133
Metadata
- Authors
- Miao, F., Wen, B., Hu, Z., Fortino, G., Wang, X.-P., Liu, Z.-D., Tang, M., & Li, Y.
- Venue
- Artificial Intelligence in Medicine
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 108
- Pages
- 101919
- ISSN
- 0933-3657 (ISSN-L)
- OpenAlex
- W3037304592
- Cited by
- 145
- References
- 13
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous blood pressure measurement from one-channel electrocardiogram signal using deep-learning techniques. https://app.cochat.ai/papers/10.1016/j.artmed.2020.101919
- The paper
- Miao, F., Wen, B., Hu, Z., Fortino, G., Wang, X.-P., Liu, Z.-D., Tang, M., & Li, Y. (2020). Continuous blood pressure measurement from one-channel electrocardiogram signal using deep-learning techniques. Artificial Intelligence in Medicine. https://doi.org/10.1016/j.artmed.2020.101919
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.