Protein interactions with subcutaneously implanted biosensors
Abstract
Biofouling of in vivo glucose sensors has been indicated as the primary reason for sensitivity losses observed during the first 24 h after implant [Wisniewski N, Moussy F, Reichert WM. Characterization of implantable biosensor membrane biofouling. Fresen J Anal Chem 2000; 366(6-7): 611-621]. Identification of the biomolecules that contribute to these sensitivity perturbations is the primary objective of the research presented. Active needle-type glucose sensors were implanted in Sprague-Dawley rats for 24h, and then a proteomics approach was used to identify the substances absorbed to the sensors. MALDI-TOF mass spectrometry was the primary tool utilized to identify the biomolecules in sensor leachate samples and species absorbed directly on sensor membranes excised from explanted in vivo sensors. Not surprisingly serum albumin was identified as the primary biomolecule present, however, predominantly as endogenous fragments of the protein. In addition, several other biomolecule fragments, mainly less than 15 kD, were identified. Based on these findings, it is concluded that fragments of larger biomolecules infiltrate the sensor membranes causing diminished glucose diffusivity, thus decreasing in vivo sensitivity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A layer of inflammatory tissue forms around each CSII cannula that contains plasma proteins, platelets, red blood cells, white blood cells, and cellular debris.”
From Detailed Analysis of Insulin Absorption Variability and the Tissue Response to Continuous Subcutaneous Insulin Infusion Catheter Implantation in Swine (2017) · cites this paper as [15]
In the citing paper
“the majority of the biofouling proteins on the sensor membrane were fragments <15 kDa.102–103”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [102]
Citations
Cites
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M. S., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,996
ExPASy: the proteomics server for in-depth protein knowledge and analysis
Gasteiger, E. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg563 · Cited by 5,602
Rosenfeld, J., Capdevielle, J., Guillemot, J. C., & Ferrara, P. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90061-b · Cited by 1,239
Surveying for Surfaces that Resist the Adsorption of Proteins
Chapman, R., Ostuni, E., Takayama, S., Holmlin, R. E., Yan, L., & Whitesides, G. M. (2000) · Journal of the American Chemical Society · doi:10.1021/ja000774f · Cited by 600
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Self-citationIdentification of rapid changes at plasma–solid interfaces
Vroman, L., & Adams, A. L. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030106 · Cited by 422
Polyurethanes in Biomedical Applications
Lamba, N. M. K., Woodhouse, K. A., & Cooper, S. L. (2017) · Routledge eBooks · doi:10.1201/9780203742785-9 · Cited by 413
Characterization of implantable biosensor membrane biofouling
Wisniewski, N. A., Moussy, F. G., & Reichert, W. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 351
Flagged first, then by citations
1 of the 40 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Dudley, 1993, Coatings for the prevention of fouling of microfiltration membranes, Chem Eng Res Des, 71, 327
- Ishihara, 1997, Prevention of protein adsorption by the phospholipid polymers, Polym Mater Sci Eng, 77, 574
- Zhang, 1993, Application of biosensors to in-vivo measurements, Proc. Electrochem. Soc., 93–97, 781
Cited by
Sorted by citations
Items 101–117 of 117
Tathireddy, P., Solzbacher, F., Hitchcock, R., & Hoffmann, K. (2011) · Springer eBooks · doi:10.1007/978-3-540-74658-4_40 · Cited by 2
Sokolov, A. (2012) · NORA - Norwegian Open Research Archives · Cited by 2
Microelectrode Biosensors for In Vivo Functional Monitoring of Biological Molecules
Marinesco, S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.13879-x · Cited by 2
Mathematical Model and Fabrication of Multi-Layer Electrochemical Glucose Sensors
Croce, R. A., Vaddiraju, S., Legassey, A., Papadimitrakopoulos, F., & Jain, F. (2015) · International Journal of High Speed Electronics and Systems · doi:10.1142/s0129156415500123 · Cited by 1
Turner, A. P. F., & Gifford, R. (2012) · Springer series on chemical sensors and biosensors · doi:10.1007/5346_2012_37 · Cited by 1
Self-citationImproving Biocompatibility of Implantable Bioelectronics using Zwitterionic Cysteine
Lin, P. H. (2017) · UWSpace (University of Waterloo) · Cited by 1
Nitric Oxide Generating Polymers (NOGPs).
Hwang, S. (2007) · Deep Blue (University of Michigan)
Modern Electrochemistry in Nanobiology and Sensorics
Sołoducho, J., & Cabaj, J. (2014) · InTech eBooks · doi:10.5772/58335
Batzias, F. A., & Siontorou, C. G. (2012)
Christopher, C., Heath, D., & Connolly, P. (2011) · InTech eBooks · doi:10.5772/19340
An implantable sensor for disease detection and treatment
Ngoepe, M. P. (2014) · University of the Witwatersrand, Johannesburg Institutional Repository on DSpace (University of the Witwatersrand, Johannesburg)
Implantable Electrochemical Biosensors: A Perspective
Joseph, I. (2012) · doi:10.1201/b13721-13
The Effects of Implant-Associated Tissue Reactions on Implantable Glucose Sensor Performance
Novak, M. T. (2014) · DukeSpace (Duke University)
Biocapteurs implantables pour un monitorage intracérébral minimalement invasif
Chatard, C. (2018) · theses.fr (ABES) · doi:10.70675/1880b7a0z30d6z4a12za2b9za72ac2b0053b
Nogler, M. E., Kumar, R. U., Morgan, L., Schaefer, C. J., El-Ahmad, H., Reinhard, S. J., Ramrattan, T. D., Picciotti, S. L., Wallet, S. M., Nichols, T. C., et al. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140435
Requirements for an Invasive Sensor
Córcoles, E. P., & Boutelle, M. G. (2013) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-00360-3_3
Metadata
- Authors
- Gifford, R., Kehoe, J. J., Barnes, S. L., Kornilayev, B. A., Alterman, M. A., & Wilson, G. S.
- Affiliations
- University of Kansas (US)
- Corresponding author
- Wilson, George S.
- ORCID
- Alterman, Michail A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2006-04
- Volume
- 27
- Issue
- 12
- Pages
- 2587-2598
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2026455723
- Cited by
- 117
- References
- 40
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 5 · 2018: 7 · 2017: 9 · 2016: 9 · 2015: 9 · 2014: 7 · 2013: 7 · 2012: 13
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk055297-03)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK55297)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- subcutaneous glucose sensor, implantable biosensors, biofouling, protein adsorption, serum albumin, sensor membranes, proteomics, MALDI-TOF mass spectrometry
- MeSH terms
- Adsorption, Animals, Biocompatible Materials, Glucose, Male, Monitoring, Physiologic, Proteins, Biosensing Techniques, Rats, Sprague-Dawley, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Prostheses and Implants, Proteomics, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review