CoChat

The heart rate discrimination task: A psychophysical method to estimate the accuracy and precision of interoceptive beliefs

Open access
Legrand, Nicolas, Nikolova, Niia, Correa, Camile, Brændholt, Malthe, Stuckert, Anna, Kildahl, Nanna, Vejlø, Melina, Fardo, Francesca, Allen, Micah · 2022 · Biological Psychology

Published version of a preprint

Cited by 152

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

Abstract Interoception - the physiological sense of our inner bodies - has risen to the forefront of psychological and psychiatric research. Much of this research utilizes tasks that attempt to measure the ability to accurately detect cardiac signals. Unfortunately, these approaches are confounded by well-known issues limiting their validity and interpretation. At the core of this controversy is the role of subjective beliefs about the heart rate in confounding measures of interoceptive accuracy. Here, we recast these beliefs as an important part of the causal machinery of interoception, and offer a novel psychophysical “heart rate discrimination“ method to estimate their accuracy and precision. By applying this task in 223 healthy participants, we demonstrate that cardiac interoceptive beliefs are more biased, less precise, and are associated with poorer metacognitive insight relative to an exteroceptive control condition. Our task, provided as an open-source python package, offers a robust approach to quantifying cardiac beliefs. Highlights Current interoception tasks conflate cardiac beliefs with accuracy. We introduce a Bayesian method for estimating cardiac belief accuracy and precision. Individuals underestimate their heart rate by -7 BPM (95% CI [-8.6 -5.3]) on average. Cardiac beliefs are associated with reduced precision and metacognitive insight. The task and modelling tools are provided in the Python Cardioception Package.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biopsycho.2021.108239

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Research works printed but not linked: 43

  1. Allen, 2020, Thinking through prior bodies: Autonomic uncertainty and interoceptive self-inference, Behavioral and Brain Sciences, 43, 10.1017/S0140525X19002899 · DOI
  2. Allen, 2021, Raincloud plots: A multi-platform tool for robust data visualization, Wellcome Open Research, 4, 63, 10.12688/wellcomeopenres.15191.2 · DOI · Paper page
  3. Allen, 2018, Vol. 1
  4. Beck, 2019, Metacognition across sensory modalities: Vision, warmth, and nociceptive pain, Cognition, 186, 32, 10.1016/j.cognition.2019.01.018 · DOI
  5. Brener, 1993, A method of constant stimuli for examining heartbeat detection: Comparison with the Brener-Kluvitse and Whitehead methods, Psychophysiology, 30, 657, 10.1111/j.1469-8986.1993.tb02091.x · DOI · Paper page
  6. Brener Jasper, 2016, Towards a psychophysics of interoceptive processes: The measurement of heartbeat detection, Philosophical Transactions of the Royal Society B: Biological Sciences, 371
  7. Clemens, 1979, Assessment, learning, and retention of heart beat discrimination, Psychophysiology, 16, 333, 10.1111/j.1469-8986.1979.tb01472.x · DOI · Paper page
  8. Cornsweet, 1962, The staircase-method in psychophysics, The American Journal of Psychology, 75, 485, 10.2307/1419876 · DOI · Paper page
  9. Dale, 1978, Information variables in voluntary control and classical conditioning of heart rate: Field dependence and heart-rate perception, Perceptual and Motor Skills, 47, 79, 10.2466/pms.1978.47.1.79 · DOI · Paper page
  10. Desmedt, 2020, A systematic review and meta-analysis on the association between heartbeat counting task performance and mental disorders and their risk factors among adults, OSF Preprints
  11. Desmedt, 2018, The heartbeat counting task largely involves non-interoceptive processes: Evidence from both the original and an adapted counting task, Biological Psychology, 138, 185, 10.1016/j.biopsycho.2018.09.004 · DOI · Paper page
  12. Desmedt, 2020, What if the heartbeat counting task required no measure of cardiac activity, PsyArXiv
  13. Dixon, 1948, A method for obtaining and analyzing sensitivity data, Journal of the American Statistical Association, 43, 109, 10.1080/01621459.1948.10483254 · DOI · Paper page
  14. Eggart, 2019, Major depressive disorder is associated with impaired interoceptive accuracy: A systematic review, Brain Sciences, 9, 131, 10.3390/brainsci9060131 · DOI · Paper page
  15. Fleming, 2017, HMeta-d: Hierarchical Bayesian estimation of metacognitive efficiency from confidence ratings, Neuroscience of Consciousness, 2017, 007, 10.1093/nc/nix007 · DOI · Paper page
  16. Flynn, 1988, On the validity of heartbeat tracking tasks, Psychophysiology, 25, 92, 10.1111/j.1469-8986.1988.tb00965.x · DOI · Paper page
  17. Forkmann, 2019, Sense it and use it: Interoceptive accuracy and sensibility in suicide ideators, BMC Psychiatry, 19, 334, 10.1186/s12888-019-2322-1 · DOI
  18. García-Pérez, 2014, Adaptive psychophysical methods for nonmonotonic psychometric functions, Attention, Perception, & Psychophysics, 76, 621, 10.3758/s13414-013-0574-2 · DOI
  19. Hart, 2013, Emotional regulation and bodily sensation: Interoceptive awareness is intact in borderline personality disorder, Journal of Personality Disorders, 27, 506, 10.1521/pedi_2012_26_049 · DOI · Paper page
  20. Hénaff, 2020, Representation of visual uncertainty through neural gain variability, Nature Communications, 11, 2513, 10.1038/s41467-020-15533-0 · DOI
  21. Hoffman, 2011, The No-U-Turn sampler: Adaptively setting path lengths in Hamiltonian Monte Carlo, ArXiv
  22. Kontsevich, 1999, Bayesian adaptive estimation of psychometric slope and threshold, Vision Research, 39, 2729, 10.1016/S0042-6989(98)00285-5 · DOI · Paper page
  23. Kumar, 2019, ArviZ a unified library for exploratory analysis of Bayesian models in Python, Journal of Open Source Software, 4, 1143, 10.21105/joss.01143 · DOI · Paper page
  24. Lee, 2018, Cross-domain association in metacognitive efficiency depends on first-order task types, Frontiers in Psychology, 9
  25. Legrand, 2022, Systole: A python package for cardiac signal synchrony and analysis., Journal of Open Source Software, 7, 3832, 10.21105/joss.03832 · DOI
  26. Lipponen, 2019, A robust algorithm for heart rate variability time series artefact correction using novel beat classification, Journal of Medical Engineering & Technology, 43, 173, 10.1080/03091902.2019.1640306 · DOI · Paper page
  27. Maniscalco, 2012, A signal detection theoretic approach for estimating metacognitive sensitivity from confidence ratings, Consciousness and Cognition, 21, 422, 10.1016/j.concog.2011.09.021 · DOI · Paper page
  28. Murphy, 2018, Knowledge of resting heart rate mediates the relationship between intelligence and the heartbeat counting task, Biological Psychology, 133, 1, 10.1016/j.biopsycho.2018.01.012 · DOI · Paper page
  29. Palmer, C., Ainley, V., & Tsakiris, M. (2019). Fine Tuning Your Heart: A novel method for measuring interoceptive accuracy . · DOI
  30. Peirce, 2019, PsychoPy2: Experiments in behavior made easy, Behavior Research Methods, 51, 195, 10.3758/s13428-018-01193-y · DOI · Paper page
  31. Pennebaker, 1984, Visceral perception versus visceral detection: Disentangling methods and assumptions, Biofeedback and Self-Regulation, 9, 339, 10.1007/BF00998977 · DOI
  32. Prins, 2012, The psychometric function: The lapse rate revisited, Journal of Vision, 12, 10.1167/12.6.25 · DOI · Paper page
  33. Prins, 2018, Applying the model-comparison approach to test specific research hypotheses in psychophysical research using the Palamedes toolbox, Frontiers in Psychology, 9, 1250, 10.3389/fpsyg.2018.01250 · DOI · Paper page
  34. Salvatier, 2016, Probabilistic programming in Python using PyMC3, PeerJ Computer Science, 2, 10.7717/peerj-cs.55 · DOI · Paper page
  35. Smith, 2020, A Bayesian computational model reveals a failure to adapt interoceptive precision estimates across depression, anxiety, eating, and substance use disorders, PLoS Computational Biology, 16, 10.1371/journal.pcbi.1008484 · DOI · Paper page
  36. Smith, 2021, Gut inference: A computational modelling approach, Biological Psychology, 164, 10.1016/j.biopsycho.2021.108152 · DOI · Paper page
  37. Valton, V., Wise, T., & Robinson, O. J. (2020). Recommendations for Bayesian hierarchical model specifications for case-control studies in mental health. ArXiv:2011.01725 [Cs, Stat]. 〈http://arxiv.org/abs/2011.01725〉. · arXiv
  38. van Bergen, 2015, Sensory uncertainty decoded from visual cortex predicts behavior, Nature Neuroscience, 18, 1728, 10.1038/nn.4150 · DOI · Paper page
  39. Warren, 2016, Catecholamine-mediated increases in gain enhance the precision of cortical representations, Journal of Neuroscience, 36, 5699, 10.1523/JNEUROSCI.3475-15.2016 · DOI · Paper page
  40. Whitehead, 1977, Relation of heart rate control to heartbeat perception, Biofeedback and Self-Regulation, 2, 371, 10.1007/BF00998623 · DOI · Paper page
  41. Windmann, 1999, Dissociating beliefs about heart rates and actual heart rates in patients with cardiac pacemakers, Psychophysiology, 36, 339, 10.1017/S0048577299980381 · DOI · Paper page
  42. Zamariola, 2018, Interoceptive accuracy scores from the heartbeat counting task are problematic: Evidence from simple bivariate correlations, Biological Psychology, 137, 12, 10.1016/j.biopsycho.2018.06.006 · DOI · Paper page
  43. Zimprich, 2020, Are interoceptive accuracy scores from the heartbeat counting task problematic? A comment on Zamariola et al. (2018), Biological Psychology, 152, 10.1016/j.biopsycho.2020.107868 · DOI

Cited by

See all 152

Metadata

Authors
Legrand, N., Nikolova, N., Correa, C., Brændholt, M., Stuckert, A., Kildahl, N., Vejlø, M., Fardo, F., & Allen, M.
Venue
Biological Psychology
Publisher
Elsevier BV
Published
2022-02
Volume
168
Pages
108239
ISSN
0301-0511 (ISSN-L)
OpenAlex
W4226030869
Cited by
152
References
47
FWCI
15.55
Type
journal article
Language
en
Open access
hybrid
Licence
Funders
  • H2020 Marie Skłodowska-Curie Actions
  • Horizon 2020 (948838)
  • European Commission (754513)
  • European Research Council
  • Aarhus Universitets Forskningsfond
  • Centro Euro-Mediterraneo sui Cambiamenti Climatici
  • Horizon 2020 Framework Programme
  • Lundbeckfonden (R272-2017-4345)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The heart rate discrimination task: A psychophysical method to estimate the accuracy and precision of interoceptive beliefs. https://app.cochat.ai/papers/10.1016/j.biopsycho.2021.108239
The paper
Legrand, N., Nikolova, N., Correa, C., Brændholt, M., Stuckert, A., Kildahl, N., Vejlø, M., Fardo, F., & Allen, M. (2022). The heart rate discrimination task: A psychophysical method to estimate the accuracy and precision of interoceptive beliefs. Biological Psychology. https://doi.org/10.1016/j.biopsycho.2021.108239

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.