Re-usable electrochemical glucose sensors integrated into a smartphone platform
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This article demonstrates a new smartphone-based reusable glucose meter. The glucose meter includes a custom-built smartphone case that houses a permanent bare sensor strip, a stylus that is loaded with enzyme-carbon composite pellets, and sensor instrumentation circuits. A custom-designed Android-based software application was developed to enable easy and clear display of measured glucose concentration. A typical test involves the user loading the software, using the stylus to dispense an enzymatic pellet on top of the bare sensor strip affixed to the case, and then introducing the sample. The electronic module then acquires and wirelessly transmits the data to the application software to be displayed on the screen. The deployed pellet is then discarded to regain the fresh bare sensor surface. Such a unique working principle allows the system to overcome challenges faced by previously reported reusable sensors, such as enzyme degradation, leaching, and hysteresis effects. Studies reveal that the enzyme loaded in the pellets are stable for up to 8 months at ambient conditions, and generate reproducible sensor signals. The work illustrates the significance of the pellet-based sensing system towards realizing a reusable, point-of-care sensor that snugly fits around a smartphone and which does not face issues usually common to reusable sensors. The versatility of this system allows it to be easily modified to detect other analytes for application in a wide range of healthcare, environmental and defense domains.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · cited 1×
“Consequently, invasive, minimally invasive (Gilligan et al., 2004; ValdésRamírez et al., 2014; Wang et al., 2005; Zimmermann et al., 2003), and non-invasive (Vashist, 2012) glucose monitoring approaches have been a research topic for decades (Imani et al., 2016; Newman and Turner, 2005; Wang, 2008).”
BackgroundSelf-citationNon-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · cited 1×
“Hence, most prior-art solutions rely on screen-printing functionalized electrodes on paper strips that are inserted into the glucometer device (or smartphone dongle), and disposed of afterwards (Bandodkar and Wang, 2014; Kim et al., 2017; Ramchandani and Heptulla, 2012).”
BackgroundSelf-citationUS spending on personal health care and public health, 1996-2013.
Dieleman, J. L., Baral, R., Birger, M., Bui, A. L., Bulchis, A., Chapin, A., Hamavid, H., Horst, C., Johnson, E. K., Joseph, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.16885 · Cited by 1,044 · cited 1×
“The financial effect of this disease is immense, with most countries spending between 5–20% of total healthcare expenditure on diabetes and related health issues (Dieleman et al., 2016).”
BackgroundTattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700 · cited 3×
“…such sensors operate by measuring the output of electrochemical reactions catalyzed by glucose-specific enzymes via functionalized electrodes, and, unfortunately, such functionalization is destroyed after only a few uses due to gradual leaching of sensor reagents (Bandodkar et al., 2015a).”
BackgroundMethodSelf-citationNon-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390 · cited 1×
“In an ideal world, monitoring should be accomplished non-invasively; while there has been recent progress towards such an approach (Abellán-Llobregat et al., 2017; Alexeev et al., 2004; Bandodkar et al., 2015b; Tierney et al., 2001), challenges remain towards successful commercialization.”
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · cited 1×
“In an ideal world, monitoring should be accomplished non-invasively; while there has been recent progress towards such an approach (Abellán-Llobregat et al., 2017; Alexeev et al., 2004; Bandodkar et al., 2015b; Tierney et al., 2001), challenges remain towards successful commercialization.”
Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.058 · Cited by 348 · cited 1×
“In an ideal world, monitoring should be accomplished non-invasively; while there has been recent progress towards such an approach (Abellán-Llobregat et al., 2017; Alexeev et al., 2004; Bandodkar et al., 2015b; Tierney et al., 2001), challenges remain towards successful commercialization.”
Self-citationGuerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287 · cited 1×
“Unfortunately, there is no cure, and as a result, diabetic patients must carefully manage their disease via periodic measurement of blood glucose levels (Guerci et al., 2003; Kirk and Stegner, 2010; Sönksen et al., 1978).”
BackgroundFeasibility of Continuous Long-Term Glucose Monitoring from a Subcutaneous Glucose Sensor in Humans
Gilligan, B. C., Shults, M., Rhodes, R. K., Jacobs, P. G., Brauker, J. H., Pintar, T. J., & Updike, S. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198089 · Cited by 71 · cited 1×
“Consequently, invasive, minimally invasive (Gilligan et al., 2004; ValdésRamírez et al., 2014; Wang et al., 2005; Zimmermann et al., 2003), and non-invasive (Vashist, 2012) glucose monitoring approaches have been a research topic for decades (Imani et al., 2016; Newman and Turner, 2005; Wang, 2008).”
Background
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationElectrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Self-citationUmapathi, R., Ghoreishian, S. M., Sonwal, S., Rani, G. M., & Huh, Y. S. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214305 · Cited by 547
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Significance of nanomaterials in electrochemical glucose sensors: An updated review (2016-2020)
Sehit, E., & Altintas, Z. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112165 · Cited by 380
Metadata
- Authors
- Bandodkar, A. J., Imani, S., Nuñez-Flores, R., Kumar, R., Wang, C., Mohan, A. M. V., Wang, J., & Mercier, P. P.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-03
- Volume
- 101
- Pages
- 181-187
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2763804371
- Cited by
- 114
- References
- 10
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Re-usable electrochemical glucose sensors integrated into a smartphone platform. https://app.cochat.ai/papers/10.1016/j.bios.2017.10.019
- The paper
- Bandodkar, A. J., Imani, S., Nuñez-Flores, R., Kumar, R., Wang, C., Mohan, A. M. V., Wang, J., & Mercier, P. P. (2018). Re-usable electrochemical glucose sensors integrated into a smartphone platform. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2017.10.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.