The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Detection of antibodies against SARS-CoV-2 spike protein by gold nanospikes in an opto-microfluidic chip
Open accessAbstract
The ongoing global pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has led to active research in its associated diagnostics and medical treatments. While quantitative reverse transcription polymerase chain reaction (qRT-PCR) is the most reliable method to detect viral genes of SARS-CoV-2, serological tests for specific antiviral antibodies are also important as they identify false negative qRT-PCR responses, track how effectively the patient’s immune system is fighting the infection, and are potentially helpful for plasma transfusion therapies. In this work, based on the principle of localized surface plasmon resonance (LSPR), we develop an opto-microfluidic sensing platform with gold nanospikes, fabricated by electrodeposition, to detect the presence and amount of antibodies specific to the SARS-CoV-2 spike protein in 1μL of human plasma diluted in 1mL of buffer solution, within ∼30min. The target antibody concentration can be correlated with the LSPR wavelength peak shift of gold nanospikes caused by the local refractive index change due to the antigen–antibody binding. This label-free microfluidic platform achieves a limit of detection of ∼0.08ng/mL (∼0.5pM), falling under the clinical relevant concentration range. We demonstrate that our opto-microfluidic platform offers a promising point-of-care testing tool to complement standard serological assays and make SARS-CoV-2 quantitative diagnostics easier, cheaper, and faster.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
A new coronavirus associated with human respiratory disease in China
Wu, F., Zhao, S., Yu, B., Chen, Y.-M., Wang, W., Song, Z.-G., Hu, Y., Tao, Z.-W., Tian, J.-H., Pei, Y.-Y., et al. (2020) · Nature · doi:10.1038/s41586-020-2008-3 · Cited by 11,688
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344
Localized Surface Plasmon Resonance Spectroscopy and Sensing
Willets, K. A., & Van Duyne, R. P. (2007) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.58.032806.104607 · Cited by 6,171
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
Li, R., Pei, S., Chen, B., Song, Y., Zhang, T., Yang, W., & Shaman, J. (2020) · Science · doi:10.1126/science.abb3221 · Cited by 3,633
Antibody responses to SARS-CoV-2 in patients with COVID-19
Long, Q.-X., Liu, B.-Z., Deng, H.-J., Wu, G.-C., Deng, K., Chen, Y.-K., Liao, P., Qiu, J.-F., Lin, Y., Cai, X.-F., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0897-1 · Cited by 2,876
Limit of detection. A closer look at the IUPAC definition
Long, G. L., & Winefordner, J. D. (1983) · Analytical Chemistry · doi:10.1021/ac00258a001 · Cited by 2,162
Covid-19 — Navigating the Uncharted
Fauci, A. S., Lane, H. C., & Redfield, R. R. (2020) · New England Journal of Medicine · doi:10.1056/nejme2002387 · Cited by 1,969
Effectiveness of convalescent plasma therapy in severe COVID-19 patients
Duan, K., Liu, B., Li, C., Zhang, H., Yu, T., Qu, J., Zhou, M., Chen, L., Meng, S., Hu, Y., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2004168117 · Cited by 1,960
Seo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837
A serological assay to detect SARS-CoV-2 seroconversion in humans
Amanat, F., Stadlbauer, D., Strohmeier, S., Nguyen, T. H. O., Chromikova, V., McMahon, M., Jiang, K., Arunkumar, G. A., Jurczyszak, D., Polanco, J., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0913-5 · Cited by 1,769
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Okba, N. M. A., Müller, M. A., Li, W., Wang, C., GeurtsvanKessel, C. H., Corman, V. M., Lamers, M. M., Sikkema, R. S., de Bruin, E., Chandler, F. D., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2607.200841 · Cited by 1,614
Ghaffari, S., Chandorkar, S. A., Wang, S., Ng, E. J., Ahn, C. H., Hong, V., Yang, Y., & Kenny, T. W. (2014) · Scientific Reports · doi:10.1038/srep04331 · Cited by 1,521
Shape- and Size-Dependent Refractive Index Sensitivity of Gold Nanoparticles
Chen, H., Kou, X., Yang, Z., Ni, W., & Wang, J. (2008) · Langmuir · doi:10.1021/la800305j · Cited by 1,334
Molecular Diagnosis of a Novel Coronavirus (2019-nCoV) Causing an Outbreak of Pneumonia
Chu, D. K. W., Pan, Y., Cheng, S. M. S., Hui, K. P. Y., Krishnan, P., Liu, Y., Ng, D. Y. M., Wan, C. K. C., Yang, P., Wang, Q., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa029 · Cited by 1,278
Qiu, G., Gai, Z., Tao, Y., Schmitt, J., Kullak-Ublick, G. A., & Wang, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c02439 · Cited by 1,059
The Hill equation revisited: uses and misuses
Weiss, J. N. (1997) · The FASEB Journal · doi:10.1096/fasebj.11.11.9285481 · Cited by 1,000
Assay Techniques and Test Development for COVID-19 Diagnosis
Carter, L. J., Garner, L. V., Smoot, J. W., Li, Y., Zhou, Q., Saveson, C. J., Sasso, J. M., Gregg, A. C., Soares, D. J., Beskid, T. R., et al. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00501 · Cited by 985
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Moitra, P., Alafeef, M., Dighe, K., Frieman, M. B., & Pan, D. (2020) · ACS Nano · doi:10.1021/acsnano.0c03822 · Cited by 745
Zhao, S., Musa, S. S., Lin, Q., Ran, J., Yang, G., Wang, W., Lou, Y., Yang, L., Gao, D., He, D., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020388 · Cited by 439
Covid-19: identifying and isolating asymptomatic people helped eliminate virus in Italian village
Day, M. (2020) · BMJ · doi:10.1136/bmj.m1165 · Cited by 409
La Marca, A., Capuzzo, M., Paglia, T., Roli, L., Trenti, T., & Nelson, S. M. (2020) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2020.06.001 · Cited by 389
Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19
Bhalla, N., Pan, Y., Yang, Z., & Payam, A. F. (2020) · ACS Nano · doi:10.1021/acsnano.0c04421 · Cited by 385
Diagnostic methods and potential portable biosensors for coronavirus disease 2019
Cui, F., & Zhou, H. S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112349 · Cited by 373
Ultra-sensitive and high-throughput CRISPR-p owered COVID-19 diagnosis
Huang, Z., Tian, D., Liu, Y., Lin, Z., Lyon, C. J., Lai, W., Fusco, D., Drouin, A., Yin, X., Hu, T., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112316 · Cited by 332
Serology assays to manage COVID-19
Krammer, F., & Simon, V. (2020) · Science · doi:10.1126/science.abc1227 · Cited by 325
A high-throughput neutralizing antibody assay for COVID-19 diagnosis and vaccine evaluation
Muruato, A. E., Fontes-Garfias, C. R., Ren, P., Garcia-Blanco, M. A., Menachery, V. D., Xie, X., & Shi, P.-Y. (2020) · Nature Communications · doi:10.1038/s41467-020-17892-0 · Cited by 319
Sensing using localised surface plasmon resonance sensors
Szunerits, S., & Boukherroub, R. (2012) · Chemical Communications · doi:10.1039/c2cc33266c · Cited by 318
Ahmadivand, A., Gerislioglu, B., Ramezani, Z., Kaushik, A., Manickam, P., & Ghoreishi, S. A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.112971 · Cited by 314
The impact of biosensing in a pandemic outbreak: COVID-19
Morales‐Narváez, E., & Dincer, C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112274 · Cited by 306
Convalescent Plasma to Treat COVID-19: Possibilities and Challenges
Roback, J. D., & Guarner, J. (2020) · JAMA · doi:10.1001/jama.2020.4940 · Cited by 299
Serological Approaches for COVID-19: Epidemiologic Perspective on Surveillance and Control
Lee, C. Y.-P., Lin, R. T. P., Renia, L., & Ng, L. F. P. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.00879 · Cited by 260
Recent advances in lab-on-a-chip technologies for viral diagnosis
Zhu, H., Fohlerová, Z., Pekárek, J., Basova, E., & Neužil, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112041 · Cited by 251
Development of Point-of-Care Biosensors for COVID-19
Choi, J. R. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00517 · Cited by 250
Mavrikou, S., Moschopoulou, G., Tsekouras, V., & Kintzios, S. (2020) · Sensors · doi:10.3390/s20113121 · Cited by 236
Zhang, S., Garcia-D'Angeli, A., Brennan, J. P., & Huo, Q. (2014) · The Analyst · doi:10.1039/c3an01835k · Cited by 219
The important role of serology for COVID-19 control
Winter, A. K., & Hegde, S. T. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30322-4 · Cited by 216
Direct electrodeposition of nanoporous gold with controlled multimodal pore size distribution
Cherevko, S., & Chung, C.-H. (2011) · Electrochemistry Communications · doi:10.1016/j.elecom.2010.11.001 · Cited by 186
Shape-Controlled Electrodeposition of Gold Nanostructures
Tian, Y., Liu, H., Zhao, G., & Tatsuma, T. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp065292q · Cited by 152
Trends and Innovations in Biosensors for COVID‐19 Mass Testing
Santiago, I. (2020) · ChemBioChem · doi:10.1002/cbic.202000250 · Cited by 140
Lopa, N. S., Rahman, M. M., Ahmed, F., Ryu, T., Sutradhar, S. C., Jin, L., Kim, J., Kim, D. H., Lee, Y. H., & Kim, W. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.012 · Cited by 87
Biosensor Applications of Electrodeposited Nanostructures
Stine, K. J. (2019) · Applied Sciences · doi:10.3390/app9040797 · Cited by 77
Surface plasmon resonance biosensor for direct detection of antibodies against human growth hormone
Kausaite‐Minkstimiene, A., Ramanavičienė, A., & Ramanavičius, A. (2009) · The Analyst · doi:10.1039/b907315a · Cited by 57
Recent Developments of Electrochemical and Optical Biosensors for Antibody Detection
Xu, W., Wang, D., Li, D., & Liu, C.-C. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms21010134 · Cited by 47
Validation and performance comparison of three SARS‐CoV‐2 antibody assays
Paiva, K. J., Grisson, R. D., Chan, P. A., Huard, R. C., Caliendo, A. M., Lonks, J. R., King, E., Tang, E. W., Pytel‐Parenteau, D. L., Nam, G. H., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.26341 · Cited by 43
Mohammadniaei, M., Go, A., Chavan, S. G., Koyappayil, A., Kim, S.-E., Yoo, H. J., Min, J., & Lee, M. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111468 · Cited by 31
Cited by
Ramesh, M., Janani, R., Deepa, C., & Rajeshkumar, L. (2022) · Biosensors · doi:10.3390/bios13010040 · Cited by 443
Zhang, M., Wang, P., Luo, R., Wang, Y., Li, Z., Guo, Y., Yao, Y., Li, M., Tao, T., Chen, W., et al. (2021) · Advanced Science · doi:10.1002/advs.202002928 · Cited by 236
Miranda, B., Rea, I., Dardano, P., De Stefano, L., & Forestiere, C. (2021) · Biosensors · doi:10.3390/bios11040107 · Cited by 63
Metadata
- Authors
- Funari, R., Chu, K.-Y., & Shen, A. Q.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 169
- Pages
- 112578
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3081977270
- Cited by
- 279
- References
- 49
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.