Multiplexed immunosensors for point-of-care diagnostic applications
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Accurate, reliable, and cost-effective immunosensors are clinically important for the early diagnosis and monitoring of progressive diseases, and multiplexed sensing is a promising strategy for the next generation of diagnostics. This strategy allows for the simultaneous detection and quantification of multiple biomarkers with significantly enhanced reproducibility and reliability, whilst requiring smaller sample volumes, fewer materials, and shorter average analysis time for individual biomarkers than individual tests. In this opinionated review, we compare different techniques for the development of multiplexed immunosensors. We review the state-of-the-art approaches in the field of multiplexed immunosensors using electrical, electrochemical, and optical methods. The barriers that prevent translating this sensing strategy into clinics are outlined together with the potential solutions. We also share our vision on how multiplexed immunosensors will continue their evolution in the coming years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Santos, A. G., da Rocha, G. O., & de Andrade, J. B. (2019) · Scientific Reports · doi:10.1038/s41598-018-37186-2 · Cited by 8,495
Re-epithelialization and immune cell behaviour in an ex vivo human skin model
Rakita, A., Nikolić, N., Mildner, M., Matiasek, J., & Elbe-Bürger, A. (2020) · Scientific Reports · doi:10.1038/s41598-019-56847-4 · Cited by 8,228
U1 snRNP regulates cancer cell migration and invasion in vitro
Oh, J.-M., Venters, C. C., Di, C., Pinto, A. M., Wan, L., Younis, I., Cai, Z., Arai, C., So, B. R., Duan, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13993-7 · Cited by 7,157
Advancing research diagnostic criteria for Alzheimer's disease: the IWG-2 criteria
Dubois, B., Feldman, H. H., Jacova, C., Hampel, H., Molinuevo, J. L., Blennow, K., DeKosky, S. T., Gauthier, S., Selkoe, D., Bateman, R., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70090-0 · Cited by 3,321
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436 · cited 1×
“An example of early milestone work in this area comes from Zheng et al. who developed an electrical multiplexed sensor for the detection of cancer biomarkers using silicon nanowires (Zheng et al., 2005).”
BackgroundMicrofluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222 · cited 1×
“Although this configuration of microfluidics can be further integrated for high-level multiplexing with more advanced fabrication techniques (Thorsen et al., 2002), it is not a practical application for POC diagnostic in the current set-up, due to its sensor complexity, bulky pneumatic control…”
BackgroundRissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119 · cited 1×
“In the 2010s, a single molecule assay (Simoa) was reported and became the state-of-the-art technology in simultaneously quantifying multiple biomarkers at extremely low concentrations, from sub-picograms to femtograms per millilitre (Rissin et al., 2010).”
MethodThree-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246 · cited 1×
“This μPAD platform allows the liquid sample to flow in all directions, and potentially distribute one single sample into hundreds of sensing points, enabling more sensing devices to be integrated within a limited footprint (Martinez et al., 2008).”
BackgroundKoczula, K. M., & Gallotta, A. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150012 · Cited by 1,147
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719 · cited 1×
“…is particularly evident in patients with progressive diseases (Dubois et al., 2014), including neurodegenerative diseases (Li et al., 2020), cancer (Chikkaveeraiah et al., 2012), cardiac diseases (Mohammed and Desmulliez, 2011), infectious diseases (Xu et al., 2020) and many other health…”
BackgroundBlood-based biomarkers for Alzheimer disease: mapping the road to the clinic
Hampel, H., O’Bryant, S. E., Molinuevo, J. L., Zetterberg, H., Masters, C. L., Lista, S., Kiddle, S. J., Batrla, R., & Blennow, K. (2018) · Nature Reviews Neurology · doi:10.1038/s41582-018-0079-7 · Cited by 716 · cited 1×
“These reasons limit their accessibility and availability as frontline diagnostic tools, especially for patients in lower-income regions and countries (Hampel et al., 2018).”
BackgroundMicrofluidic immunosensor systems
Bange, A. F., Halsall, H. B., & Heineman, W. R. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.016 · Cited by 609 · cited 2×
“Enzyme-linked immunosorbent assay (ELISA), the most commonly used method developed in the 1970s (Bange et al., 2005; Kadimisetty et al., 2015), offers sensitivity at picograms per millilitre for the detection of protein biomarkers, but long analysis times, the ability to detect only single…”
BackgroundMethodMultiplexed Point-of-Care Testing – xPOCT
Dincer, C., Bruch, R., Kling, A., Dittrich, P. S., & Urban, G. A. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.013 · Cited by 503 · cited 1×
“…information extracted from detection, simple patient intervention or operation, rapid sample-to-results turnover time ( 2 h), cost-effective and portable readout system, adequate long storage and shelf life and, most importantly, clinically relevant sensitivity and accuracy (Dincer et al., 2017).”
BackgroundLayqah, L. A., & Eissa, S. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3345-5 · Cited by 380 · cited 1×
“Simply by replacing the corresponding capture antibodies on the surface of working electrodes, this platform has also demonstrated its potential for the sensitive detection of coronavirus (Layqah and Eissa, 2019) and up to seven tumour biomarkers (Wilson and Nie, 2006b; Wu et al., 2007).”
A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing
Pollock, N. R., Rolland, J. P., Kumar, S., Beattie, P. D., Jain, S., Noubary, F., Wong, V. L., Pohlmann, R. A., Ryan, U. S., & Whitesides, G. M. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003981 · Cited by 326
duPont, N. C., Wang, K., Wadhwa, P. D., Culhane, J. F., & Nelson, E. L. (2005) · Journal of Reproductive Immunology · doi:10.1016/j.jri.2005.03.005 · Cited by 318
Mohammed, M.-I., & Desmulliez, M. P. Y. (2011) · Lab Chip · doi:10.1039/c0lc00204f · Cited by 304
A flexible multiplexed immunosensor for point-of-care in situ wound monitoring
Gao, Y., Nguyen, D. T., Yeo, T., Lim, S. B., Tan, W. X., Madden, L. E., Jin, L., Long, J. Y. K., Aloweni, F. A. B., Liew, Y. J. A., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg9614 · Cited by 283 · cited 1×
“The collector consists of an array of half-open, sawtooth-shaped capillary to guide the body fluid flow directionally towards the sensors (Gao et al., 2021).”
BackgroundLisowski, P., & Zarzycki, P. K. (2013) · Chromatographia · doi:10.1007/s10337-013-2413-y · Cited by 239 · cited 4×
“In contrast to standard LFAs, μPADs have not been widely commercialised for POC diagnostic applications yet; this could be due to the increased production cost, the increased complexity of the production mechanism (numerous steps), the inadequate (semiquantitative) sensitivity and reproducibility (due to the nature of…”
BackgroundInfluentialDevelopment of electrochemical immunosensors towards point of care diagnostics
Wan, Y., Su, Y., Zhu, X., Liu, G., & Fan, C. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.045 · Cited by 232 · cited 1×
“…detection (Kadimisetty et al., 2018), optical absorbance and colorimetry (Phillips et al., 2018)), magnetic and electrical (e.g., giant magnetoresistance (Gao et al., 2019), field effect transistor (Kim et al., 2020)), and electrochemical sensors (Jirakova et al., 2019; Wan et al., 2013).”
BackgroundLi, J., & Macdonald, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.021 · Cited by 223 · cited 2×
“LFAs are the most well-established paper based POC platforms (including nitrocellulose membranes, although it is not paper), due to their structural simplicity, fast detection, and low production cost (Li and Macdonald, 2016b).”
BackgroundMethodPortable Microfluidic Integrated Plasmonic Platform for Pathogen Detection
Tokel, O., Yildiz, U. H., Inci, F., Durmus, N. G., Ekiz, O. O., Turker, B., Cetin, C., Rao, S., Sridhar, K., Natarajan, N., et al. (2015) · Scientific Reports · doi:10.1038/srep09152 · Cited by 210 · cited 6×
“The optical measurement can also be performed in a label-free manner using the SPR technique on metallic sensor surfaces.”
MethodInfluentialLee, H. J., Nedelkov, D., & Corn, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac060881d · Cited by 193 · cited 1×
“As a successful demonstration, an SPR-based antibody microarray with spot sizes from 200 to 750 μm was created to simultaneously detect β2-microglobulin and cystatin C at a concentration of 1 nM–300 nM (Lee et al., 2006).”
MethodRoda, A., Cavalera, S., Di Nardo, F., Calabria, D., Rosati, S., Simoni, P., Colitti, B., Baggiani, C., Roda, M., & Anfossi, L. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112765 · Cited by 191 · cited 1×
“One representative example is the multiplexed lateral flow assays (LFA), which could utilise optical signal generated by colorimetric (Xu et al., 2020), fluorescent (Jin et al., 2021), or chemiluminescent mechanisms (Roda et al., 2021).”
BackgroundZhou, F., Lu, M., Wang, W., Bian, Z., Zhang, J., & Zhu, J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.147256 · Cited by 151 · cited 1×
“For example, the detection of multiple biomarkers can be achieved using different redox particles in a single microfluidic channel (Zhou et al., 2010).”
BackgroundContreras-Naranjo, J. E., & Aguilar, O. (2019) · Biosensors · doi:10.3390/bios9010015 · Cited by 151 · cited 1×
“This method suffers of poor specificity when applied in complex matrices as electrode surface conductivity can be affected by unspecific adsorption of sample species (Contreras-Naranjo and Aguilar, 2019).”
MethodElectrochemical Multianalyte Immunoassays Using an Array-Based Sensor
Wilson, M. S., & Nie, W. (2006) · Analytical Chemistry · doi:10.1021/ac0518452 · Cited by 144 · cited 3×
“This is specifically important for highly integrated devices (Wilson and Nie, 2006b).”
BackgroundSoler, M., Belushkin, A. A., Cavallini, A., Kebbi‐Beghdadi, C., Greub, G., & Altug, H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.047 · Cited by 142 · cited 1×
“3 (d) (Soler et al., 2017).”
Ultrasensitive high-resolution profiling of early seroconversion in patients with COVID-19
Norman, M., Gilboa, T., Ogata, A. F., Maley, A. M., Cohen, L., Busch, E. L., Lazarovits, R., Mao, C.-P., Cai, Y., Zhang, J., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00611-x · Cited by 142 · cited 1×
“…in spatially separated wells (one bead per well) and are labelled with up to four different capture antibodies (and fluorescence labels), this multiplexed technology offers LODs in the range of 10 fg/mL level in clinical body fluid samples (Lee et al., 2020; Norman et al., 2020), as shown in Fig.”
BackgroundLi, B., Pan, G., Avent, N. D., Lowry, R. B., Madgett, T. E., & Waines, P. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.034 · Cited by 134 · cited 4×
“To avoid the functionalisation of graphene through a harsh coupling reaction, the authors employed polyethyleneimine (PEI) functionalised reduced graphene oxide (rGO) for direct loading of thionine (Thi) and AuNPs to immobilise anti-CEA on ITO, whereas Prussian Blue (PB) and AuNPs were used to immobilise anti-AFP.”
MethodInfluentialSelf-citationJia, X., Liu, Z., Liu, N., & Ma, Z. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.050 · Cited by 132 · cited 1×
“Jia et al. developed a label-free immunosensor for simultaneous detection of CEA and α-fetoprotein (AFP) using indium tin oxide (ITO) sheets for the WEs and graphene nanocomposites as the supporting matrix involved in antibody-antigen immunocomplex detection (Jia et al., 2014).”
MethodAutomated Multiplexed ECL Immunoarrays for Cancer Biomarker Proteins
Kadimisetty, K., Malla, S., Sardesai, N. P., Joshi, A. A., Faria, R. C., Lee, N. H., & Rusling, J. F. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00421 · Cited by 125 · cited 2×
“…discussed in section 2 (Chen et al., 2018), by means of a scanning charge-coupled device or CMOS camera to measure the intensities of the laser-induced fluorescence (Chandra et al., 2011) or chemiluminescence (Kadimisetty et al., 2015) from the (differently) labelled secondary antibodies (Fig.”
BackgroundMethodWu, J., Yan, F., Tang, J., Zhai, C., & Ju, H. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.086975 · Cited by 124 · cited 1×
“Simply by replacing the corresponding capture antibodies on the surface of working electrodes, this platform has also demonstrated its potential for the sensitive detection of coronavirus (Layqah and Eissa, 2019) and up to seven tumour biomarkers (Wilson and Nie, 2006b; Wu et al., 2007).”
Amperometric Electrochemical Microsystem for a Miniaturized Protein Biosensor Array
Yang, C., Huang, Y., Hassler, B. L., Worden, R. M., & Mason, A. J. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2015650 · Cited by 121
Multiplex measurement of twelve tumor markers using a GMR multi-biomarker immunoassay biosensor
Gao, Y., Huo, W., Zhang, L., Lian, J., Tao, W., Song, C., Tang, J., Shi, S. D. ‐., & Gao, Y. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.060 · Cited by 116 · cited 3×
“…detection (Kadimisetty et al., 2018), optical absorbance and colorimetry (Phillips et al., 2018)), magnetic and electrical (e.g., giant magnetoresistance (Gao et al., 2019), field effect transistor (Kim et al., 2020)), and electrochemical sensors (Jirakova et al., 2019; Wan et al., 2013).”
BackgroundMethodRuan, X., Wang, Y., Kwon, E. Y., Wang, L., Cheng, N., Niu, X., Ding, S., Wie, B. V., Lin, Y., & Du, D. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113238 · Cited by 115 · cited 1×
“Multiplexed LFAs normally rely on the generation of optical signals as outputs (Taranova et al., 2015), but some recent approaches have explored the use of electrochemical detection to improve test sensitivity (Ruan et al., 2021).”
BackgroundYang, F., Zuo, X., Li, Z., Deng, W., Shi, J., Zhang, G., Huang, Q., Song, S., & Fan, C. (2014) · Advanced Materials · doi:10.1002/adma.201400451 · Cited by 106 · cited 1×
“Yang and Otieno separately reported their representative microfluidics based platforms for the multiplexed detection of biomarkers (Otieno et al., 2016; Yang et al., 2014).”
BackgroundSimultaneous immunoassays of dual prostate cancer markers using a SERS-based microdroplet channel
Gao, R., Cheng, Z., Wang, X., Yu, L., Guo, Z., Zhao, G., & Choo, J. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.015 · Cited by 106 · cited 1×
“…been published on the multiplexed microfluidic immunosensor using other optical methods, such as electrochemiluminescence (Kadimisetty et al., 2018), magnetic bead assisted detection (Gao et al., 2019), SERS detection (Gao et al., 2018), or localised surface plasmon resonance (Yavas et al., 2018).”
MethodPark, D., Kim, J., Kim, H. J., Lee, D., Lee, D. S., Yoon, D. S., & Hwang, K. S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112505 · Cited by 101 · cited 1×
“10 (a), such an immunosensor could include a single channel to direct the plasma sample perpendicularly flowing over the graphene FET array, where each device is functionalised by a different antibody for multiplexing purposes (Park et al., 2020).”
BackgroundLim, W. Y., Thevarajah, T. M., Goh, B. T., & Khor, S. M. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.12.049 · Cited by 99 · cited 1×
“Although efforts have been made to combine cell phones or portable scanners to improve the portability (Lim et al., 2019), μPADs, especially in relation to multiplexed immunosensing, need to be further developed.”
BackgroundYavas, O., Aćimović, S. S., García-Guirado, J., Berthelot, J., Dobosz, P., Sanz, V., & Quidant, R. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00305 · Cited by 98 · cited 1×
“…been published on the multiplexed microfluidic immunosensor using other optical methods, such as electrochemiluminescence (Kadimisetty et al., 2018), magnetic bead assisted detection (Gao et al., 2019), SERS detection (Gao et al., 2018), or localised surface plasmon resonance (Yavas et al., 2018).”
MethodXianyu, Y., Wu, J., Chen, Y., Zheng, W., Xie, M., & Jiang, X. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801815 · Cited by 98 · cited 1×
“…immunosensors have been developed in parallel, including electro-chemiluminescent sensors (Kadimisetty et al., 2018), chemiluminescence sensors (Xianyu et al., 2018), and surface-enhanced Raman scattering (Banaei et al., 2017), which all present promising sensing performance in simultaneous B.…”
BackgroundCarbon-Dot-Enhanced Graphene Field-Effect Transistors for Ultrasensitive Detection of Exosomes
Ramadan, S., Lobo, R., Zhang, Y., Xu, L., Shaforost, O., Tsang, D. K. H., Feng, J., Yin, T., Qiao, M., Rajeshirke, A., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c18293 · Cited by 97 · cited 1×
“Upon the binding between antibodies and their specific biomarkers, the detection can be achieved via monitoring the change of electrical resistance or the shift of the Dirac B. Gil Rosa et al. Biosensors and Bioelectronics 203 (2022) 114050 point (Ramadan et al., 2021).”
BackgroundNovel multiplex technology for diagnostic characterization of rheumatoid arthritis
Chandra, P. E., Sokolove, J. B., Hipp, B. G., Lindström, T. M., Elder, J. T., Reveille, J. D., Eberl, H., Klause, U., & Robinson, W. H. (2011) · Arthritis Research & Therapy · doi:10.1186/ar3383 · Cited by 97 · cited 1×
“…discussed in section 2 (Chen et al., 2018), by means of a scanning charge-coupled device or CMOS camera to measure the intensities of the laser-induced fluorescence (Chandra et al., 2011) or chemiluminescence (Kadimisetty et al., 2015) from the (differently) labelled secondary antibodies (Fig.”
BackgroundMultiplex detection of pancreatic cancer biomarkers using a SERS-based immunoassay
Banaei, N., Foley, A., Houghton, J. M., Sun, Y., & Kim, B. G. (2017) · Nanotechnology · doi:10.1088/1361-6528/aa8e8c · Cited by 83 · cited 1×
“…electro-chemiluminescent sensors (Kadimisetty et al., 2018), chemiluminescence sensors (Xianyu et al., 2018), and surface-enhanced Raman scattering (Banaei et al., 2017), which all present promising sensing performance in simultaneous B. Gil Rosa et al. Biosensors and Bioelectronics 203 (2022)…”
BackgroundJin, Y., Chen, Q., Luo, S., He, L., Fan, R., Zhang, S., Yang, C., & Chen, Y. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2020.127718 · Cited by 78 · cited 1×
“One representative example is the multiplexed lateral flow assays (LFA), which could utilise optical signal generated by colorimetric (Xu et al., 2020), fluorescent (Jin et al., 2021), or chemiluminescent mechanisms (Roda et al., 2021).”
BackgroundKadimisetty, K., Malla, S., Bhalerao, K. S., Mosa, I. M., Bhakta, S., Lee, N. H., & Rusling, J. F. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01198 · Cited by 75 · cited 3×
“…to surface plasmonic sensors, other multiplexed optical immunosensors have been developed in parallel, including electro-chemiluminescent sensors (Kadimisetty et al., 2018), chemiluminescence sensors (Xianyu et al., 2018), and surface-enhanced Raman scattering (Banaei et al., 2017), which all…”
BackgroundMethodInfluentialKhetani, S., Kollath, V. O., Kundra, V., Nguyen, M. D., Debert, C. T., Sen, A., Karan, K., & Sanati‐Nezhad, A. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00076 · Cited by 70 · cited 2×
“The latter B. Gil Rosa et al. Biosensors and Bioelectronics 203 (2022) 114050 mechanism is essentially measuring electroactive species within (Li et al., 2021) or associated to the captured antigens (Khetani et al., 2018).”
BackgroundMethodOtieno, B. A., Krause, C. E., Jones, A. L., Kremer, R. B., & Rusling, J. F. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02637 · Cited by 63 · cited 1×
“Yang and Otieno separately reported their representative microfluidics based platforms for the multiplexed detection of biomarkers (Otieno et al., 2016; Yang et al., 2014).”
Liu, R., Wang, N., Kamili, F., & Sarioglu, A. F. (2016) · Lab on a Chip · doi:10.1039/c6lc00209a · Cited by 59
A bio-inspired 3D micro-structure for graphene-based bacteria sensing
Li, B., Tan, H., Anastasova, S., Power, M., Seichepine, F., & Yang, G. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.087 · Cited by 56 · cited 1×
“Upon binding of the corresponding antigen on the sensing channel, the drain-source current can be modulated, from which the concentration of the target biomarker can be determined (Li et al., 2019).”
BackgroundSelf-citationSankhala, D., Muthukumar, S., & Prasad, S. (2018) · SLAS TECHNOLOGY · doi:10.1177/2472630318759257 · Cited by 55 · cited 1×
“Sankhala et al. developed a flexible 4-channel chemi-impedance sensor fabricated on polyamide substrate with gold electrodes deposited by e-beam cryo-evaporation (Sankhala et al., 2018).”
BackgroundMultiplexed immunoassay using post-synthesis functionalized hydrogel microparticles
Lee, H. J., Roh, Y. H., Kim, H. U., Kim, S. M., & Bong, K. W. (2019) · Lab on a Chip · doi:10.1039/c8lc01160e · Cited by 52
Hierarchically structured microchip for point-of-care immunoassays with dynamic detection ranges
Mou, L., Dong, R., Hu, B., Li, Z., Zhang, J., & Jiang, X. (2019) · Lab on a Chip · doi:10.1039/c9lc00517j · Cited by 46
Clinical detection of neurodegenerative blood biomarkers using graphene immunosensor
Li, B., Tan, H., Jenkins, D., Raghavan, V. S., Rosa, B. M. G., Güder, F., Pan, G., Yeatman, E. M., & Sharp, D. J. (2020) · Carbon · doi:10.1016/j.carbon.2020.06.048 · Cited by 45 · cited 7×
“To avoid the functionalisation of graphene through a harsh coupling reaction, the authors employed polyethyleneimine (PEI) functionalised reduced graphene oxide (rGO) for direct loading of thionine (Thi) and AuNPs to immobilise anti-CEA on ITO, whereas Prussian Blue (PB) and AuNPs were used to immobilise anti-AFP.”
BackgroundMethodInfluentialSelf-citationSoares, R. R. G., Santos, D. R. D., Pinto, I. F., Azevedo, A. M., Aires-Barros, M. R., Chu, V., & Conde, J. P. (2018) · Lab on a Chip · doi:10.1039/c8lc00259b · Cited by 45
A modular microarray imaging system for highly specific COVID-19 antibody testing
Hedde, P. N., Abram, T. J., Jain, A., Nakajima, R., de Assis, R. R., Pearce, T., Jasinskas, A., Toosky, M., Khan, S., Felgner, P. L., et al. (2020) · Lab on a Chip · doi:10.1039/d0lc00547a · Cited by 43
SERS and electrochemical impedance spectroscopy immunoassay for carcinoembryonic antigen
Castaño‐Guerrero, Y., Moreira, F. T. C., Sousa‐Castillo, A., Correa‐Duarte, M. A., & Sales, M. G. F. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.137377 · Cited by 43 · cited 1×
“Castano-Guerrero et al. proposed an innovative dual detection approach for carcinoembryonic antigen (CEA), combining EIS measurements and SERS in sequential time readings over the same sensing layer (Castaño-Guerrero et al., 2021).”
BackgroundNode-pore sensing: a robust, high-dynamic range method for detecting biological species
Balakrishnan, K. R., Anwar, G., Chapman, M. R., Nguyen, T., Kesavaraju, A., & Sohn, L. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41286e · Cited by 41 · cited 1×
“Other multiplexed frequency encoding schemes used the node pore sensing (NPS) approach generated by the passage of cells through pores with different spacing between them (Balakrishnan et al., 2013), allowing accurate measurement of particle/cell sizes with increased spectral dynamic range.”
MethodMoráňová, L., Hrstka, R., Campuzano, S., Pingarrón, J. M., & Bartošík, M. (2018) · Electroanalysis · doi:10.1002/elan.201800573 · Cited by 39
Molderez, T. R., Prévoteau, A., Ceyssens, F., Verhelst, M., & Rabaey, K. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112813 · Cited by 34 · cited 1×
“4 (a) (Molderez et al., 2021), time division multiplexing can be achieved with a single electronic channel that incorporates an analogue multiplexer where signals from different sensors are routed to the common acquisition channel.”
BackgroundSimultaneous multi-analyte urinary protein assay for bladder cancer detection
Rosser, C. J., Dai, Y. E., Miyake, M., Zhang, G., & Goodison, S. (2014) · BMC Biotechnology · doi:10.1186/1472-6750-14-24 · Cited by 33 · cited 5×
“But they are less sensitive than laboratory ELISAs and incapable of providing accurate quantitative diagnostic information, such as the concentration of biomarkers (Koczula and Gallotta, 2016).”
BackgroundInfluentialVaidyanathan, R., van Leeuwen, L. M., Rauf, S., Shiddiky, M. J. A., & Trau, M. (2015) · Scientific Reports · doi:10.1038/srep09756 · Cited by 32 · cited 1×
“5 (b) and functionalised with capture antibodies specific to human epidermal growth factor receptor 2 (HER2), prostate specific antigens (PSA) and immunoglobulin (Vaidyanathan et al., 2015).”
BackgroundSequentially multiplexed amperometry for electrochemical biosensors
Wu, D., Rios-Aguirre, D., Chounlakone, M., Camacho-León, S., & Voldman, J. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.049 · Cited by 30 · cited 3×
“Following this, Wu et al. proposed a sequential multiplexing methodology for detection of human interleukin-6 (IL-6) and procalcitonin (PCT) by means of 5-fold multiplexed biosensors in an amperometry topology with WE and CE fabricated by deposition of titanium and gold onto a Pyrex wafer, whereas Ag/AgCl ink was used…”
MethodInfluentialHarshavardhan, S., Rajadas, S. E., Vijayakumar, K. K., Durai, W. A., Ramu, A., & Mariappan, R. (2019) · Wiley eBooks · doi:10.1002/9781119611103.ch18 · Cited by 26
Label-Free Biomarker Assay in a Microresistive Pulse Sensor via Immunoaggregation
Han, Y., Wu, H., Liu, F., Cheng, G., & Zhe, J. (2014) · Analytical Chemistry · doi:10.1021/ac502270n · Cited by 26 · cited 1×
“…range of 0.01–300 mg/mL. Wu et al. developed a microparticle (MP)-based immunoaggregation assay for detection of goat anti-rabbit IgG and human ferritin as model macromolecular biomarkers by inducing the formation of aggregation in PBS and 10% FBS solutions (Han et al., 2014; Wu et al., 2015).”
BackgroundInfluentialEissa, S., Abdulkarim, H., Dasouki, M., Al‐Mousa, H., Arnout, R., Al‐Saud, B., Rahman, A. M. A., & Zourob, M. M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.058 · Cited by 23 · cited 1×
“Eissa et al. successfully demonstrated a microarray based immunosensor for the simultaneous detection of three immunodeficiency disorder biomarkers with LODs down to a few picograms per millilitre (Eissa et al., 2018), as shown in Fig.”
MethodFeasibility in the development of a multi-marker detection platform
Lin, C., Lindsey, R., Probst, D., Caplan, M. R., Spano, M. L., & Belle, J. T. L. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.073 · Cited by 23 · cited 1×
“With this in mind, Lin et al. employed EIS to detect the optimal frequencies of purified low- and high-density lipoproteins (LDL and HDL) co-immobilised on a multi-marked platform (Lin et al., 2017).”
MethodAlzheimer's Disease Diagnosis Using Misfolding Proteins in Blood
Lee, H., Ugay, D. A., Hong, S., & Kim, Y. S. (2020) · Dementia and Neurocognitive Disorders · doi:10.12779/dnd.2020.19.1.1 · Cited by 17 · cited 1×
“…in spatially separated wells (one bead per well) and are labelled with up to four different capture antibodies (and fluorescence labels), this multiplexed technology offers LODs in the range of 10 fg/mL level in clinical body fluid samples (Lee et al., 2020; Norman et al., 2020), as shown in Fig.”
BackgroundMonitoring amyloid-β 42 conformational change using a spray-printed graphene electrode
Li, B., Zhang, G., Tahirbegi, I. B., Morten, M. J., & Tan, H. (2021) · Electrochemistry Communications · doi:10.1016/j.elecom.2021.106927 · Cited by 16 · cited 1×
“The latter B. Gil Rosa et al. Biosensors and Bioelectronics 203 (2022) 114050 mechanism is essentially measuring electroactive species within (Li et al., 2021) or associated to the captured antigens (Khetani et al., 2018).”
BackgroundSelf-citationA multiplexed immunoaggregation biomarker assay using a two-stage micro resistive pulse sensor
Han, Y., Wu, H., Liu, F., Cheng, G., & Zhe, J. (2016) · Biomicrofluidics · doi:10.1063/1.4944456 · Cited by 11 · cited 2×
“One recent example presented a microfluidic electrochemical immunosensor for simultaneous detection of three different viruses (Han et al., 2016a).”
BackgroundMethodWang, N., Liu, R., Asmare, N., Chu, C., & Sarioglu, A. F. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112818 · Cited by 9 · cited 1×
“This barcode-based electrical platform can identify and measure the percentage of particles carrying target biomarkers, and the number of biomarkers to be measured can be easily increased by adding additional sections with the potential of error calibration (Wang et al., 2021).”
BackgroundA microfluidic competitive immuno-aggregation assay for high sensitivity cell secretome detection
Liu, F., Kc, P., Ni, L., Zhang, G., & Zhe, J. (2018) · Organogenesis · doi:10.1080/15476278.2018.1461306 · Cited by 8 · cited 11×
“…multiplexing, however, require advanced microfabrication techniques to tailor the geometry of the sensing substrate or units for the correct generation of the encoding frequency patterns, thus, proving exceedingly difficult to apply to nanopores and nanochannels biosensing (Liu et al., 2018c).”
BackgroundMethodInfluential
Cited by
Colorimetric sensing for translational applications: from colorants to mechanisms
Jin, Z., Yim, W., Retout, M., Housel, E., Zhong, W., Zhou, J., Strano, M. S., & Jokerst, J. V. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00328d · Cited by 206
Cutshaw, G., Uthaman, S., Hassan, N., Kothadiya, S., Wen, X., & Bardhan, R. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00897 · Cited by 199
Metadata
- Authors
- Gil Rosa, B., Akingbade, O. E., Guo, X., Gonzalez-Macia, L., Crone, M. A., Cameron, L. P., Freemont, P., Choy, K.-L., Güder, F., Yeatman, E., Sharp, D. J., & Li, B.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2022-05
- Volume
- 203
- Pages
- 114050
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W4210413514
- Cited by
- 184
- References
- 74
- FWCI
- 10.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.