Deep eutectic solvent dependent carbon dioxide switching as a homogeneous extracting solvent in liquid-liquid microextraction
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A miscible-immiscible deep eutectic solvent (DES) containing monoethanolamine/4-methoxyphenol was used as an extraction solvent in a homogeneous liquid-liquid microextraction (HLLME). The method was used to preconcentrate chlorobenzenes in water samples followed by separating and analyzing them by gas chromatography-mass spectroscopy (GC-MS). A special feature of the new extraction method is that a green miscible solvent was used as an extractant in the HLLME method. The developed extraction technique provided enrichment factors in the range of 13.1-42.1 for extraction from only 1.0 mL of the aqueous sample solution. The effects of various experimental parameters were investigated and optimized. The optimal conditions were as follows: vortex time: 30.0 s, bubbling CO2 gas: 1.0 min, salt concentration: 5.0% w/v, rate and time of centrifuge: 4000.0 rpm and 3.0 min, respectively, and DES volume: 30.0 µL. The limit of detections and the limit of quantifications for the four targeted analytes varied from 0.01-0.15 and 0.025-0.5 µg L-1, respectively. The precision and long-term precision tests for the developed method were found to be less than 11.0%. Two real samples, including toilet air freshener and car perfume, were analyzed. The applied DES in the HLLME method provides a fast means of sample preparation for environmental aqueous sample solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radošević, K., Ćurko, N., Gaurina Srček, V., Cvjetko Bubalo, M., Tomašević, M., Kovačević Ganić, K., & Radojčić Redovniković, I. (2016) · LWT · doi:10.1016/j.lwt.2016.05.037 · Cited by 404
Zhu, S., Zhou, J., Jia, H., & Zhang, H. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2017.09.141 · Cited by 166
Jia, L., Huang, X., Zhao, W., Wang, H., & Jing, X. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2020.126424 · Cited by 96
Research works printed but not linked: 26
- Smith, 2014, Deep eutectic solvents (DESs) and their applications, Chem. Rev., 114, 11060, 10.1021/cr300162p · DOI · Paper page
- Onwukamike, 2018, Detailed understanding of the DBU/CO2 switchable solvent system for cellulose solubilization and derivatization, ACS Sustain. Chem. Eng., 6, 1496, 10.1021/acssuschemeng.7b04053 · DOI
- Darabi, 2016, CO-responsive polymeric materials: synthesis, self-assembly, and functional applications, Chem. Soc. Rev., 45, 4391, 10.1039/C5CS00873E · DOI · Paper page
- Pollet, 2011, Switchable solvents, Chem. Sci., 2, 609, 10.1039/c0sc00568a · DOI
- Jessop, 2012, CO-triggered switchable solvents, surfactants, and other materials, Energy Environ. Sci., 5, 7240, 10.1039/c2ee02912j · DOI · Paper page
- Wang, 2019, Solidification of a switchable solvent-based QuEChERS method for detection of 16 pesticides in some fruits and vegetables, J. Agric. Food Chem., 67, 8045, 10.1021/acs.jafc.9b00686 · DOI
- Wang, 2018, Development of CO2-mediated switchable hydrophilicity solvent-based microextraction combined with HPLC-UV for the determination of bisphenols in foods and drinks, Food Anal. Methods, 11, 2093, 10.1007/s12161-018-1187-0 · DOI
- Ahmar, 2018, Switchable hydrophilicity solvent-based homogenous liquid-liquid microextraction (SHS-HLLME) combined with GC-FID for the quantification of methadone and tramadol, Chromatographia, 81, 1063, 10.1007/s10337-018-3528-y · DOI
- Wan, 2019, Miscible-immiscible transition of deep eutectic solvents in water switched by CO2, ACS Sustain. Chem. Eng., 7, 17882, 10.1021/acssuschemeng.9b04430 · DOI
- He, 1997, Liquid-phase microextraction in a single drop of organic solvent by using a conventional microsyringe, Anal. Chem., 69, 4634, 10.1021/ac970242q · DOI · Paper page
- Yazdanfar, 2014, Homogeneous liquid-liquid microextraction for determination of organochlorine pesticides in water and fruit samples, Chromatographia, 77, 329, 10.1007/s10337-013-2604-6 · DOI
- Malaei, 2018, Analysis of malondialdehyde in human plasma samples through derivatization with 2,4-dinitrophenylhydrazine by ultrasound-assisted dispersive liquid-liquid microextraction-GC-FID approach, J. Chromatogr. B, 1089, 60, 10.1016/j.jchromb.2018.05.001 · DOI · Paper page
- Hammond, 2017, The effect of water upon deep eutectic solvent nanostructure: an unusual transition from ionic mixture to aqueous solution, Angew. Chem. Int. Ed., 56, 9782, 10.1002/anie.201702486 · DOI · Paper page
- Faraji, 2019, Determination of some red dyes in food samples using a hydrophobic deep eutectic solvent-based vortex assisted dispersive liquid-liquid microextraction coupled with high performance liquid chromatography, J. Chromatogr. A, 1591, 15, 10.1016/j.chroma.2019.01.022 · DOI · Paper page
- Kamarei, 2010, Optimization of temperature-controlled ionic liquid dispersive liquid phase microextraction combined with high performance liquid chromatography for analysis of chlorobenzenes in water samples, Talanta, 83, 36, 10.1016/j.talanta.2010.08.035 · DOI
- Lu, 2013, Determination of chlorobenzenes in textiles by pressurized hot water extraction followed by vortex-assisted liquid-liquid microextraction and gas chromatography-mass spectrometry, J. Chromatogr. A, 1319, 27, 10.1016/j.chroma.2013.10.050 · DOI
- Zhao, 2009, Ionic liquid-based headspace single-drop microextraction coupled to gas chromatography for the determination of chlorobenzene derivatives, Microchim. Acta, 165, 29, 10.1007/s00604-008-0092-4 · DOI
- Ebrahimpour, 2014, Homogeneous liquid-phase microextraction followed by filtration-based phase separation coupled to high-performance liquid chromatography, J. Sep. Sci., 37, 2002, 10.1002/jssc.201400257 · DOI
- Khajeh, 2006, Trace analysis of chlorobenzenes in water samples using headspace solvent microextraction and gas chromatography/electron capture detection, Talanta, 69, 1088, 10.1016/j.talanta.2005.12.020 · DOI
- Vidal, 2007, An ionic liquid as a solvent for headspace single drop microextraction of chlorobenzenes from water samples, Anal. Chim. Acta, 584, 189, 10.1016/j.aca.2006.10.053 · DOI · Paper page
- Zhang, 2014, Gas chromatographic determination of three chlorophenols in toilet paper by ultrasonic assisted extraction and synchronous derivative dispersive liquid-liquid microextraction, Anal. Methods, 6, 207, 10.1039/C3AY40797G · DOI
- Zhang, 2014, Solid-phase microextraction with a graphene-composite-coated fiber coupled with GC for the determination of some halogenated aromatic hydrocarbons in water samples, J. Sep. Sci., 37, 440, 10.1002/jssc.201301183 · DOI
- Kozani, 2007, Part-per-trillion determination of chlorobenzenes in water using dispersive liquid-liquid microextraction combined gas chromatography-electron capture detection, Talanta, 72, 387, 10.1016/j.talanta.2006.10.039 · DOI · Paper page
- Alonso, 2011, Headspace needle-trap analysis of priority volatile organic compounds from aqueous samples: application to the analysis of natural and waste waters, J. Chromatogr. A, 1218, 8131, 10.1016/j.chroma.2011.09.042 · DOI
- Malaei, 2018, Analysis of malondialdehyde in human plasma samples through derivatization with 2,4-dinitrophenylhydrazine by ultrasound-assisted dispersive liquid-liquid microextraction-GC-FID approach, J. Chromatogr. B, 1089, 60, 10.1016/j.jchromb.2018.05.001 · DOI · Paper page
- Cortada, 2014, Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry, Talanta, 120, 191, 10.1016/j.talanta.2013.11.042 · DOI
Cited by
Responsive switchable deep eutectic solvents: A review
Zhang, J., Li, S., Yao, L., Yi, Y., Shen, L., Li, Z., & Qiu, H. (2023) · Chinese Chemical Letters · doi:10.1016/j.cclet.2022.107750 · Cited by 126
Shaaban, H., Mostafa, A., Alqarni, A. M., Alsultan, R., shehab, Z. A., Aljarrash, Z., Al-Zawad, W., Al-Kahlah, S., & Amir, M. (2023) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2023.105137 · Cited by 57
Atypical Deep Eutectic Solvents: New Opportunities for Chemical Analysis
Shishov, A., El-Deen, A. K., Godunov, P., & Bulatov, A. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117752 · Cited by 51
Zhang, K., Wang, J., Guo, R., Nie, Q., & Zhu, G. (2024) · Food Chemistry · doi:10.1016/j.foodchem.2024.138425 · Cited by 40
Abdi, K., Ezoddin, M., Novasari, V., & Lamei, N. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300878 · Cited by 6
Metadata
- Authors
- Nazraz, M., Yamini, Y., Ramezani, A. M., & Dinmohammadpour, Z.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 1636
- Pages
- 461756
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W3110859324
- Cited by
- 43
- References
- 3
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- Tarbiat Modares University
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep eutectic solvent dependent carbon dioxide switching as a homogeneous extracting solvent in liquid-liquid microextraction. https://app.cochat.ai/papers/10.1016/j.chroma.2020.461756
- The paper
- Nazraz, M., Yamini, Y., Ramezani, A. M., & Dinmohammadpour, Z. (2021). Deep eutectic solvent dependent carbon dioxide switching as a homogeneous extracting solvent in liquid-liquid microextraction. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2020.461756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.