The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Towards a redefinition of the second based on optical atomic clocks
Open accessAbstract
The rapid increase in accuracy and stability of optical atomic clocks compared to the caesium atomic clock as the primary standard of time and frequency asks for a future redefinition of the second in the International System of Units (SI). The status of the optical clocks based on either single ions in radio-frequency traps or on neutral atoms stored in an optical lattice is described, with special emphasis on the current work at the Physikalisch-Technische Bundesanstalt (PTB, Braunschweig, Germany). Besides the development and operation of different optical clocks with estimated fractional uncertainties in the 10 − 18 range, the supporting work on ultra-stable lasers as core elements and the means to compare remote optical clocks with transportable standards, optical fibres, or frequency ratios is reported. Finally, the conditions, methods and next steps are discussed, which are the prerequisites for a future redefinition of the second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Our work not only enables the above mentioned applications, but also clears the path towards a redefinition of the unit of time, the SI second2425 through regular and practical international comparisons of optical clocks.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2023) · doi:10.1126/science · Cited by 6,063
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B · doi:10.1007/bf00702605 · Cited by 3,821
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 1×
“storage of a chain of multiple ions. To use a transition with a small natural line width often a quadrupole transition (e.g. 2S 1=2 - D 5=2) is employed like in the Ca +[14, 15, 16], Sr [17, 18], Hg+ [19], or Yb [20, 21] clocks (Fig. 2). All these transitions have a natural lifetime that supports a line width on the o…”
MethodAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Keßler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 755
Self-citationCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 580
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Nuclear laser spectroscopy of the 3.5 eV transition in Th-229
Peik, E., & Tamm, C. (2003) · Europhysics Letters (EPL) · doi:10.1209/epl/i2003-00210-x · Cited by 435
Prospects for a Millihertz-Linewidth Laser
Meiser, D., Ye, J., Carlson, D. R., & Holland, M. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.163601 · Cited by 378
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Ionic crystals in a linear Paul trap
Raizen, M. G., Gilligan, J. M., Bergquist, J., Itano, W. M., & Wineland, D. J. (1992) · Physical Review A · doi:10.1103/physreva.45.6493 · Cited by 330
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. R. (2004) · Science · doi:10.1126/science.1105497 · Cited by 302
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Ultrastable lasers based on vibration insensitive cavities
Millo, J., Magalhães, D. V., Mandache, C., Coq, Y. L., English, E., Westergaard, P. G., Lodewyck, J., Bize, S., Lemonde, P., & Santarelli, G. (2009) · Physical Review A · doi:10.1103/physreva.79.053829 · Cited by 244
High-Accuracy Optical Clock Based on the Octupole Transition in Yb+171
Huntemann, N., Okhapkin, M. V., Lipphardt, B., Weyers, S., Tamm, C., & Peik, E. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.090801 · Cited by 241
Sr87 Lattice Clock with Inaccuracy below 10−15
Boyd, M. M., Ludlow, A. D., Blatt, S., Foreman, S. M., Ido, T., Zelevinsky, T., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.083002 · Cited by 187
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Bjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165
Madej, A. A., Dubé, P., Zhou, Z., Bernard, J. E., & Gertsvolf, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203002 · Cited by 155
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 153
The absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 153
Schrama, C. A., Peik, E., Smith, W. W., & WALTHER, H. (1993) · Optics Communications · doi:10.1016/0030-4018(93)90318-y · Cited by 151
Hyper-Ramsey spectroscopy of optical clock transitions
Yudin, V. I., Тайченачев, А. В., Oates, C. W., Barber, Z. W., Lemke, N., Ludlow, A. D., Sterr, U., Lisdat, C., & Riehle, F. (2010) · Physical Review A · doi:10.1103/physreva.82.011804 · Cited by 139
Self-citationThermal noise in optical cavities revisited
Kessler, T., Legero, T., & Sterr, U. (2011) · Journal of the Optical Society of America B · doi:10.1364/josab.29.000178 · Cited by 130
The87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Self-citationExcitation of the Isomeric Th229m Nuclear State via an Electronic Bridge Process in Th+229
Porsev, S. G., Flambaum, V. V., Peik, E., & Tamm, C. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.182501 · Cited by 128
Nuclear clocks based on resonant excitation of γ-transitions
Peik, E., & Okhapkin, M. V. (2015) · Comptes Rendus Physique · doi:10.1016/j.crhy.2015.02.007 · Cited by 118
A transportable strontium optical lattice clock
Poli, N., Schioppo, M., Vogt, S., Falke, S., Sterr, U., Lisdat, C., & Tino, G. M. (2014) · Applied Physics B · doi:10.1007/s00340-014-5932-9 · Cited by 114
Measuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer
Hong, F.-L., Musha, M., Takamoto, M., Inaba, H., Yanagimachi, S., Takamizawa, A., Watabe, K.-I., Ikegami, T., Imae, M., Fujii, Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000692 · Cited by 113
An optical lattice clock with spin-polarized 87Sr atoms
Baillard, X., Fouché, M., Targat, R. L., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, D., Laurent, P., Rosenbusch, P., et al. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00330-3 · Cited by 112
Precision Calculation of Blackbody Radiation Shifts for Optical Frequency Metrology
Safronova, M. S., Kozlov, M. G., & Clark, C. W. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.143006 · Cited by 111
Sympathetic cooling of mixed-species two-ion crystals for precision spectroscopy
Wübbena, J. B., Amairi‐Pyka, S., Mandel, O., & Schmidt, P. O. (2012) · Physical Review A · doi:10.1103/physreva.85.043412 · Cited by 108
Direct Comparison of Distant Optical Lattice Clocks at the $10^{-16}$ Uncertainty
Yamaguchi, A., Fujieda, M., Kumagai, M., Hachisu, H., Nagano, S., Li, Y., Ido, T., Takano, T., Takamoto, M., & Katori, H. (2011) · Applied Physics Express · doi:10.1143/apex.4.082203 · Cited by 106
Optical atomic clocksPreprint
Poli, N., Oates, C. W., Gill, P. R., & Tino, G. M. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1401.2378 · Cited by 104
When should we change the definition of the second?
Gill, P. R. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0237 · Cited by 102
Development of a strontium optical lattice clock for the SOC mission on the ISS
Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., et al. (2015) · Comptes Rendus Physique · doi:10.1016/j.crhy.2015.03.009 · Cited by 97
Matsubara, K., Hachisu, H., Li, Y., Nagano, S., Locke, C., Nogami, A., Kajita, M., Hayasaka, K., Ido, T., & Hosokawa, M. (2012) · Optics Express · doi:10.1364/oe.20.022034 · Cited by 87
Linear Paul trap design for an optical clock with Coulomb crystals
Herschbach, N., Pyka, K., Keller, J., & Mehlstäubler, T. E. (2011) · Applied Physics B · doi:10.1007/s00340-011-4790-y · Cited by 81
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Frequency Measurement of the Optical Clock Transition of40Ca+Ions with an Uncertainty of 10-14Level
Matsubara, K., Hayasaka, K., Li, Y., Ito, H., Nagano, S., Kajita, M., & Hosokawa, M. (2008) · Applied Physics Express · doi:10.1143/apex.1.067011 · Cited by 65
Huang, Y., Cao, J. Z., Liu, P., Liang, K., Ou, B.-Q., Guan, H., Huang, X., Li, T., & Gao, K. (2012) · Physical Review A · doi:10.1103/physreva.85.030503 · Cited by 61
Yamaguchi, A., Shiga, N., Nagano, S., Li, Y., Ishijima, H., Hachisu, H., Kumagai, M., & Ido, T. (2012) · Applied Physics Express · doi:10.1143/apex.5.022701 · Cited by 60
Cavity-stabilized laser with acceleration sensitivity below 10−12 g −1
Leibrandt, D. R., Bergquist, J. C., & Rosenband, T. (2013) · Physical Review A · doi:10.1103/physreva.87.023829 · Cited by 59
Atomic clock ensemble in space
Cacciapuoti, L., & Salomon, C. (2011) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/327/1/012049 · Cited by 56
Time-Domain Measurement of Spontaneous Vibrational Decay of Magnetically Trapped NH
Campbell, W. C., Groenenboom, G. C., Lu, H.-I., Tsikata, E., & Doyle, J. M. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.083003 · Cited by 56
Direct comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53
Providing $10^{-16}$ Short-Term Stability of a 1.5-$\mu\hbox{m}$ Laser to Optical Clocks
Hagemann, C., Grebing, C., Keßler, T., Falke, S., Lemke, N., Lisdat, C., Schnatz, H., Riehle, F., & Sterr, U. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2242597 · Cited by 52
Self-citationAkamatsu, D., Inaba, H., Hosaka, K., Yasuda, M., Onae, A., Suzuyama, T., Amemiya, M., & Hong, F.-L. (2013) · Applied Physics Express · doi:10.7567/apex.7.012401 · Cited by 50
Time transfer by laser link (T2L2): characterization and calibration of the flight instrument
Samain, É., Vrancken, P., Guillemot, P., Fridelance, P., & Exertier, P. (2014) · Metrologia · doi:10.1088/0026-1394/51/5/503 · Cited by 45
A transportable strontium optical lattice clock
Poli, N., Vogt, S., Falke, S., Sterr, U., Lisdat, C., & Tino, G. M. (2014) · Cited by 45
Linear Paul trap design for an optical clock with Coulomb crystalsPreprint
Herschbach, N., Pyka, K., Keller, J., & Mehlstäubler, T. E. (2016) · Cited by 43
Shifts of optical frequency references based on spectral-hole burning in Eu3+:Y2SiO5
Thorpe, M. J., Leibrandt, D. R., & Rosenband, T. (2013) · New Journal of Physics · doi:10.1088/1367-2630/15/3/033006 · Cited by 38
Chen, Q., Troshyn, A., Ernsting, I., Kayser, S. A., Vasilyev, S., Nevsky, A. Y., & Schiller, S. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.223202 · Cited by 33
Time and frequency comparisons using radiofrequency signals from satellites
Bauch, A. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.02.006 · Cited by 27
Leibrandt, D. R., Thorpe, M. J., Chou, C. W., Fortier, T. M., Diddams, S. A., & Rosenband, T. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.237402 · Cited by 26
Spectral parameters of reference-cavity-stabilised lasers
Matveev, A., Kolachevsky, N., Alnis, J., & Hänsch, T. W. (2008) · Quantum Electronics · doi:10.1070/qe2008v038n04abeh013680 · Cited by 12
On secondary representations of the second
Gill, P. R., & Riehle, F. (2006) · European Frequency and Time Forum · Cited by 12
Self-citationCryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$Preprint
Das, M., Katori, H., Ushijima, I., Takamoto, M., & Ohkubo, T. (2014) · arXiv (Cornell University) · Cited by 10
Optical lattice clock with spin-polarized87Sr atoms
Baillard, X., Fouché, M., Targat, R. L., Westergaard, P. G., Lecallier, A., Lodewyck, J., Chapelet, F., Abgrall, M., Rovera, D., Laurent, P., et al. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.768810 · Cited by 2
Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$Preprint
Ushijima, I., Takamoto, M., Das, M., et al. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1405.4071
Research works printed but not linked: 1
- [63] Wolf, P.; Petit, G.; Peik, E.; Tamm, C.; Schnatz, H.; Lipphardt, B.; Weyers, S.; Wynands, R.; Richard, J.-Y.; Bize, S.; Chapelet, F.; Pereira dos Santos, F.; Clairon, A. Comparing high accuracy frequency standards via TAI, Braunschweig (2006), pp. 476-485 www.eftf.org/proceedings/proceedingsEFTF2006.pdf (ISBN: 978-1-4673-2642-1)
Cited by
Sorted by citations
Architecture for the photonic integration of an optical atomic clock
Newman, Z. L., Maurice, V. N., Drake, T. E., Stone, J. R., Briles, T. C., Spencer, D. T., Fredrick, C. D., Li, Q., Westly, D., Ilic, B., et al. (2019) · Optica · doi:10.1364/optica.6.000680 · Cited by 638
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
“This clears the path towards a redefinition of the unit of time, the SI second (20,21).”
BackgroundFrequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Metadata
- Authors
- Riehle, F.
- Corresponding author
- Riehle, Fritz
- ORCID
- Riehle, Fritz
- Venue
- Comptes Rendus. Physique
- Publisher
- MathDoc/Centre Mersenne
- Published
- 2015-06-01
- Volume
- 16
- Issue
- 5
- Pages
- 506-515
- ISSN
- 1631-0705 (ISSN-L)
- 1878-1535
- OpenAlex
- W1512386837
- Cited by
- 174
- References
- 65
- Citations by year
- 2026: 11 · 2025: 12 · 2024: 13 · 2023: 21 · 2022: 13 · 2021: 11 · 2020: 12 · 2019: 26 · 2018: 16 · 2017: 20 · 2016: 19
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Comptes Rendus Physique (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Physical Reports (submittedVersion)
- arXiv (Cornell University)
- Funders
- DFG (RTG 1729)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- redefinition of the second, optical atomic clocks, SI units, radio-frequency trap, optical lattice clock, neutral atoms, fractional frequency uncertainty, ultra-stable lasers, frequency transfer, frequency ratio, cesium atomic clock, time and frequency standards
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review