Retinal prostheses: Clinical results and future challenges
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Retinal prostheses aim at restoring visual perception in blind patients affected by retinal diseases leading to the loss of photoreceptors, such as age-related macular degeneration or retinitis pigmentosa. Recent clinical trials have demonstrated the feasibility of this approach for restoring useful vision. Despite a limited number of electrodes (60), and therefore of pixels, some patients were able to read words and to recognize high-contrast objects. Face recognition and independent locomotion in unknown urban environments imply technological breakthroughs to increase the number and density of electrodes. This review presents recent clinical results and discusses future solutions to answer the major technological challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 128$\times$128 120 dB 15 $\mu$s Latency Asynchronous Temporal Contrast Vision Sensor
Lichtsteiner, P., Posch, C., & Delbruck, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.914337 · Cited by 2,485
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Functional relevance of cross-modal plasticity in blind humans
Cohen, L. G., Celnik, P., Pascual-Leone, A., Corwell, B., Faiz, L., Dambrosia, J., Honda, M., Sadato, N., Gerloff, C., Catala´, M. D., et al. (1997) · Nature · doi:10.1038/38278 · Cited by 911 · cited 1×
“In blind patients, the visual cortex can in fact be recruited by other sensory modalities introducing a multi-modal plasticity; the visual cortex can also contributes to tactile Braille reading [53].”
BackgroundVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“The company, Second Sight Medical Products, Inc, had initially produced an implant with 16 electrodes (Argus I), which enabled blind patients to identify light targets, recognize white objects on a black background with a 20/ 3240 restored visual acuity [19,20].”
BackgroundSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Eye Smarter than Scientists Believed: Neural Computations in Circuits of the Retina
Gollisch, T., & Meister, M. (2010) · Neuron · doi:10.1016/j.neuron.2009.12.009 · Cited by 795
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 2×
“These various difficulties associated with epiretinal stimulation could explain the great variability in patient performances using Argus II, only 7 patients out of the 30 implanted were able to reliably perform complex tasks of visual acuity [21,22].”
MethodSelf-citationRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 2×
“In addition to this identical stimulation of all retinal ganglion cell types, the epiretinal approach also activates fibres passing by from the periphery toward the optic disc [18,27].”
BackgroundRetinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
Dobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Cited by
Graphene in the design and engineering of next‐generation neural interfaces
Kostarelos, K., Vincent, M., Hebert, C., & Garrido, J. A. (2017) · Advanced Materials · doi:10.1002/adma.201700909 · Cited by 206
Regenerating optic pathways from the eye to the brain
Laha, B., Stafford, B. K., & Huberman, A. D. (2017) · Science · doi:10.1126/science.aal5060 · Cited by 172
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Li, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59
Li, H., Han, T., Wang, J., Lu, Z., Cao, X., Chen, Y., Li, L., Zhou, C., & Chai, X. (2017) · Information Sciences · doi:10.1016/j.ins.2017.06.014 · Cited by 27
Metadata
- Authors
- Picaud, S., & Sahel, J.-A.
- Venue
- Comptes Rendus. Biologies
- Publisher
- MathDoc/Centre Mersenne
- Published
- 2014-02-26
- Volume
- 337
- Issue
- 3
- Pages
- 214-222
- ISSN
- 1631-0691 (ISSN-L)
- 1768-3238
- OpenAlex
- W2045553611
- Cited by
- 48
- References
- 18
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal prostheses: Clinical results and future challenges. https://app.cochat.ai/papers/10.1016/j.crvi.2014.01.001
- The paper
- Picaud, S., & Sahel, J.-A. (2014). Retinal prostheses: Clinical results and future challenges. Comptes Rendus. Biologies. https://doi.org/10.1016/j.crvi.2014.01.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.