Retinal prostheses: Clinical results and future challenges
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Retinal prostheses aim at restoring visual perception in blind patients affected by retinal diseases leading to the loss of photoreceptors, such as age-related macular degeneration or retinitis pigmentosa. Recent clinical trials have demonstrated the feasibility of this approach for restoring useful vision. Despite a limited number of electrodes (60), and therefore of pixels, some patients were able to read words and to recognize high-contrast objects. Face recognition and independent locomotion in unknown urban environments imply technological breakthroughs to increase the number and density of electrodes. This review presents recent clinical results and discusses future solutions to answer the major technological challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 128$\times$128 120 dB 15 $\mu$s Latency Asynchronous Temporal Contrast Vision Sensor
Lichtsteiner, P., Posch, C., & Delbruck, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.914337 · Cited by 2,485
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 1×
“In the case of neural prostheses, capacitive stimuli are preferred because they limit pH changes at the electrode surface [45].”
BackgroundFunctional relevance of cross-modal plasticity in blind humans
Cohen, L. G., Celnik, P., Pascual-Leone, A., Corwell, B., Faiz, L., Dambrosia, J., Honda, M., Sadato, N., Gerloff, C., Catala´, M. D., et al. (1997) · Nature · doi:10.1038/38278 · Cited by 911 · cited 1×
“In blind patients, the visual cortex can in fact be recruited by other sensory modalities introducing a multi-modal plasticity; the visual cortex can also contributes to tactile Braille reading [53].”
BackgroundVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“The company, Second Sight Medical Products, Inc, had initially produced an implant with 16 electrodes (Argus I), which enabled blind patients to identify light targets, recognize white objects on a black background with a 20/ 3240 restored visual acuity [19,20].”
BackgroundSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Eye Smarter than Scientists Believed: Neural Computations in Circuits of the Retina
Gollisch, T., & Meister, M. (2010) · Neuron · doi:10.1016/j.neuron.2009.12.009 · Cited by 795 · cited 1×
“If newer models reproduce quite successfully the properties of ganglion cells, they cannot yet satisfactorily predict responses to complex natural stimuli [56].”
BackgroundInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 2×
“These various difficulties associated with epiretinal stimulation could explain the great variability in patient performances using Argus II, only 7 patients out of the 30 implanted were able to reliably perform complex tasks of visual acuity [21,22].”
MethodSelf-citationArtificial Vision for the Blind by Connecting a Television Camera to the Visual Cortex
Dobelle, W. H. (2000) · ASAIO Journal · doi:10.1097/00002480-200001000-00002 · Cited by 584
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 2×
“In addition to this identical stimulation of all retinal ganglion cell types, the epiretinal approach also activates fibres passing by from the periphery toward the optic disc [18,27].”
BackgroundRetinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
Dobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 2×
“Two of implanted patients were also able to perform reading tasks with a rate of up to 10 words per minute [22].”
BackgroundMethodSelf-citationMobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Cortical activity during tactile exploration of objects in blind and sighted humans
Amedi, A., Raz, N., Azulay, H., Malach, R., & Zohary, E. (2010) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2010-0503 · Cited by 125 · cited 1×
“The potential for plasticity of the visual system from blind patients is based on reported functional reorganizations after the onset of blindness [51,52].”
BackgroundSommerhalder, J., Rappaz, B., de Haller, R., Fornos, A. P., Safran, A. B., & Pelizzone, M. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.017 · Cited by 116
Simulation of artificial vision: I. Eccentric reading of isolated words, and perceptual learning
Sommerhalder, J., Oueghlani, E., Bagnoud, M., Leonards, U., Safran, A. B., & Pelizzone, M. (2003) · Vision Research · doi:10.1016/s0042-6989(02)00481-9 · Cited by 111
Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68 · cited 1×
“Three different configurations were examined: a distant common ground, a bipolar stimulation between a central and an annular return electrode, and a ground grid surrounding all stimulating electrodes [39].”
BackgroundReading visual braille with a retinal prosthesis
Lauritzen, T. Z., Harris, J., Mohand-Said, S., Sahel, J. A., Dorn, J. D., McClure, K., & Greenberg, R. J. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00168 · Cited by 22 · cited 1×
“Patients could also read Braille symbols with the device [23].”
BackgroundSelf-citation
Cited by
Graphene in the design and engineering of next‐generation neural interfaces
Kostarelos, K., Vincent, M., Hebert, C., & Garrido, J. A. (2017) · Advanced Materials · doi:10.1002/adma.201700909 · Cited by 206
Regenerating optic pathways from the eye to the brain
Laha, B., Stafford, B. K., & Huberman, A. D. (2017) · Science · doi:10.1126/science.aal5060 · Cited by 172
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Li, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59
Li, H., Han, T., Wang, J., Lu, Z., Cao, X., Chen, Y., Li, L., Zhou, C., & Chai, X. (2017) · Information Sciences · doi:10.1016/j.ins.2017.06.014 · Cited by 27
Metadata
- Authors
- Picaud, S., & Sahel, J.-A.
- Venue
- Comptes Rendus. Biologies
- Publisher
- MathDoc/Centre Mersenne
- Published
- 2014-02-26
- Volume
- 337
- Issue
- 3
- Pages
- 214-222
- ISSN
- 1631-0691 (ISSN-L)
- 1768-3238
- OpenAlex
- W2045553611
- Cited by
- 48
- References
- 19
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.