The DOI matches its Crossref record.
Preliminary development of emissivity measurement system at low temperature based on radiometric method
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A stepper-motor-driven rotating sample stage in the Zhao et al. system enables automated switching between samples and efficient data acquisition.
“Furthermore, a stepper-motor-driven rotating sample stage enables automated switching between samples and efficient data acquisition.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [54]
The Zhao et al. system employs a Gifford-McMahon (G-M) cryostat as the cooling source, allowing the sample to reach a minimum temperature of 9.2 K.
“The system employs a Gifford-McMahon (G-M) cryostat as the cooling source, allowing the sample to reach a minimum temperature of 9.2 K.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [54]
The optical system of Zhao et al., incorporating an MCT detector, is completely enclosed within a vacuum chamber, thereby eliminating the influence of windows and atmospheric radiation and significantly improving measurement accuracy.
“The optical system, incorporating an MCT detector, is completely enclosed within a vacuum chamber, thereby eliminating the influence of windows and atmospheric radiation and significantly improving measurement accuracy.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [54]
Zhao et al. (2023) from the Institute of Physics and Chemistry, Chinese Academy of Sciences developed a low-temperature emissivity measurement system based on the energy method.
“In 2023, Zhao et al. [54] from the Institute of Physics and Chemistry, Chinese Academy of Sciences developed a low-temperature emissivity measurement system based on the energy method.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [54]
The evolution of radiometric methods reveals a trend in cooling methods from reliance on external cryogenic liquids (such as liquid nitrogen and liquid helium) to integrated refrigeration systems.
“Initially, cooling methods evolved from reliance on external cryogenic liquids [17,44,49,55], such as liquid nitrogen and liquid helium, to integrated refrigeration system [37,54].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [54]
There has been a transition in the arrangement of key optical paths from external detectors to fully integrated designs.
“Secondly, there has been a transition in the arrangement of key optical paths from external detectors [17,37,49,55] to fully integrated designs [54].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [54]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 13
- Králík, 2016, Method for measurement of emissivity and absorptivity of highly reflective surfaces from 20 K to room temperatures, Metrologia, 53, 743, 10.1088/0026-1394/53/2/743 · DOI · Paper page
- Herve, 2008, Direct measurement of total emissivities at cryogenic temperatures: application to satellite coatings, Cryogenics, 48, 463, 10.1016/j.cryogenics.2008.07.007 · DOI · Paper page
- Tuttle, 2016, Cryogenic thermal absorptance measurements on small-diameter stainless steel tubing, Cryogenics, 74, 166, 10.1016/j.cryogenics.2015.09.003 · DOI
- Ando, 2019, Emissivity of black plated open honeycomb and black coatings at cryogenic temperatures, IOP Conf Ser: Mater Sci Eng, 502, 10.1088/1757-899X/502/1/012071 · DOI · Paper page
- Musilova, 2005, Low temperature radiative properties of materials used in cryogenics, Cryogenics, 45, 529, 10.1016/j.cryogenics.2004.11.010 · DOI · Paper page
- Cao, 2012, Spectral emissivity measurements of candidate materials for very high temperature reactors, Nucl Eng Des, 251, 78, 10.1016/j.nucengdes.2011.10.067 · DOI
- Hao, 2018, Vacuum radiance-temperature standard facility for infrared remote sensing at NIM, Int J Thermophys, 39, 78, 10.1007/s10765-018-2396-x · DOI · Paper page
- Woods, 2012, Broadband emissivity calibration of highly reflective samples at cryogenic temperatures, Metrologia, 49, 737, 10.1088/0026-1394/49/6/737 · DOI · Paper page
- Palchetti, 2008, Design and characterisation of black-body sources for infrared wide-band Fourier transform spectroscopy, Infrared Phys Technol, 51, 207, 10.1016/j.infrared.2007.06.001 · DOI
- Yenni, 2019, Emissivity estimation of spacecraft thermal control surfaces at cryogenic temperatures – a novel experimental approach, Heat Mass Transfer, 55, 1465, 10.1007/s00231-018-2513-1 · DOI
- Adibekyan, 2017, High-Accuracy Emissivity Data on the Coatings Nextel 811–21, Herberts 1534, Aeroglaze Z306 and Acktar Fractal Black, Int J Thermophys, 38, 89, 10.1007/s10765-017-2212-z · DOI
- Tang-Kwor, 2001, Emissivity measurements for Nextel Velvet Coating 811–21 between -36 °C and 82 °C, High Temp-High Press, 33, 551, 10.1068/htwu385 · DOI
- Woods, 2014, Emissivity of silver and stainless steel from 80K to 300K: Application to ITER thermal shields, Cryogenics, 60, 44, 10.1016/j.cryogenics.2014.01.002 · DOI · Paper page
Cited by
Sorted by citations
Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review
Li, B., & Shen, F. (2026) · Cryo · doi:10.3390/cryo2010004 · Cited by 1
Self-citation
Metadata
- Authors
- Zhao, Y., Li, X., Zhang, H., Shen, F., Huang, C., Liu, H., Qi, H., Huang, Z., Geng, Z., Xin, J., Wang, W., & Li, L.
- Venue
- Cryogenics
- Publisher
- Elsevier BV
- Published
- 2023-06
- Volume
- 132
- Pages
- 103671
- ISSN
- 0011-2275
- Cited by
- 9
- References
- 0
- Language
- en
- Licence
- Funders
- National Key Research and Development Program of China (2022YFB3804003)
- National Natural Science Foundation of China (52007186)
- Chinese Academy of Sciences (ZDRW-CN-2021-4-1, YJKYYQ20200070)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review