Cited by 9

The DOI matches its Crossref record.

Preliminary development of emissivity measurement system at low temperature based on radiometric method

Zhao, Yuchen, Li, Xu, Zhang, Hengcheng, Shen, Fuzhi, Huang, Chuanjun, Liu, Huiming, Qi, Haoying, Huang, Zichun, Geng, Zhen, Xin, Jijun, Wang, Wei, Li, Laifeng·2023·Cryogenics

Overview

Integrity signals

Registry

Crossref · 10.1016/j.cryogenics.2023.103671

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A stepper-motor-driven rotating sample stage in the Zhao et al. system enables automated switching between samples and efficient data acquisition.

    “Furthermore, a stepper-motor-driven rotating sample stage enables automated switching between samples and efficient data acquisition.”
  • The Zhao et al. system employs a Gifford-McMahon (G-M) cryostat as the cooling source, allowing the sample to reach a minimum temperature of 9.2 K.

    “The system employs a Gifford-McMahon (G-M) cryostat as the cooling source, allowing the sample to reach a minimum temperature of 9.2 K.”
  • The optical system of Zhao et al., incorporating an MCT detector, is completely enclosed within a vacuum chamber, thereby eliminating the influence of windows and atmospheric radiation and significantly improving measurement accuracy.

    “The optical system, incorporating an MCT detector, is completely enclosed within a vacuum chamber, thereby eliminating the influence of windows and atmospheric radiation and significantly improving measurement accuracy.”
  • Zhao et al. (2023) from the Institute of Physics and Chemistry, Chinese Academy of Sciences developed a low-temperature emissivity measurement system based on the energy method.

    “In 2023, Zhao et al. [54] from the Institute of Physics and Chemistry, Chinese Academy of Sciences developed a low-temperature emissivity measurement system based on the energy method.”
  • The evolution of radiometric methods reveals a trend in cooling methods from reliance on external cryogenic liquids (such as liquid nitrogen and liquid helium) to integrated refrigeration systems.

    “Initially, cooling methods evolved from reliance on external cryogenic liquids [17,44,49,55], such as liquid nitrogen and liquid helium, to integrated refrigeration system [37,54].”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 13

  1. Králík, 2016, Method for measurement of emissivity and absorptivity of highly reflective surfaces from 20 K to room temperatures, Metrologia, 53, 743, 10.1088/0026-1394/53/2/743 · DOI · Paper page
  2. Herve, 2008, Direct measurement of total emissivities at cryogenic temperatures: application to satellite coatings, Cryogenics, 48, 463, 10.1016/j.cryogenics.2008.07.007 · DOI · Paper page
  3. Tuttle, 2016, Cryogenic thermal absorptance measurements on small-diameter stainless steel tubing, Cryogenics, 74, 166, 10.1016/j.cryogenics.2015.09.003 · DOI
  4. Ando, 2019, Emissivity of black plated open honeycomb and black coatings at cryogenic temperatures, IOP Conf Ser: Mater Sci Eng, 502, 10.1088/1757-899X/502/1/012071 · DOI · Paper page
  5. Musilova, 2005, Low temperature radiative properties of materials used in cryogenics, Cryogenics, 45, 529, 10.1016/j.cryogenics.2004.11.010 · DOI · Paper page
  6. Cao, 2012, Spectral emissivity measurements of candidate materials for very high temperature reactors, Nucl Eng Des, 251, 78, 10.1016/j.nucengdes.2011.10.067 · DOI
  7. Hao, 2018, Vacuum radiance-temperature standard facility for infrared remote sensing at NIM, Int J Thermophys, 39, 78, 10.1007/s10765-018-2396-x · DOI · Paper page
  8. Woods, 2012, Broadband emissivity calibration of highly reflective samples at cryogenic temperatures, Metrologia, 49, 737, 10.1088/0026-1394/49/6/737 · DOI · Paper page
  9. Palchetti, 2008, Design and characterisation of black-body sources for infrared wide-band Fourier transform spectroscopy, Infrared Phys Technol, 51, 207, 10.1016/j.infrared.2007.06.001 · DOI
  10. Yenni, 2019, Emissivity estimation of spacecraft thermal control surfaces at cryogenic temperatures – a novel experimental approach, Heat Mass Transfer, 55, 1465, 10.1007/s00231-018-2513-1 · DOI
  11. Adibekyan, 2017, High-Accuracy Emissivity Data on the Coatings Nextel 811–21, Herberts 1534, Aeroglaze Z306 and Acktar Fractal Black, Int J Thermophys, 38, 89, 10.1007/s10765-017-2212-z · DOI
  12. Tang-Kwor, 2001, Emissivity measurements for Nextel Velvet Coating 811–21 between -36 °C and 82 °C, High Temp-High Press, 33, 551, 10.1068/htwu385 · DOI
  13. Woods, 2014, Emissivity of silver and stainless steel from 80K to 300K: Application to ITER thermal shields, Cryogenics, 60, 44, 10.1016/j.cryogenics.2014.01.002 · DOI · Paper page

Cited by

Sorted by citations

Metadata

Authors
Zhao, Y., Li, X., Zhang, H., Shen, F., Huang, C., Liu, H., Qi, H., Huang, Z., Geng, Z., Xin, J., Wang, W., & Li, L.
Venue
Cryogenics
Publisher
Elsevier BV
Published
2023-06
Volume
132
Pages
103671
ISSN
0011-2275
Cited by
9
References
0
Language
en
Funders
  • National Key Research and Development Program of China (2022YFB3804003)
  • National Natural Science Foundation of China (52007186)
  • Chinese Academy of Sciences (ZDRW-CN-2021-4-1, YJKYYQ20200070)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review