Experimental study on the melted frost influence on the metal energy storage during an air source heat pump defrosting
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
When an air source heat pump works at reverse cycle defrosting mode, the metal temperature of its indoor coil decreases and that of outdoor coil increases. The energy storage of two coils’ metal at heating mode would influence the system defrosting efficiency. For a vertically installed outdoor coil having multiple circuits, meanwhile, the melted frost downwards flowing from upside circuit(s) also delay the defrosting process of downside circuit(s). To quantitatively evaluate the influence from two parameters, metal energy storage and melted frost, four experimental cases were designed and carried out in this study, based on a specially made three-circuit outdoor coil. Three circuits are working at the frosting mode, while two and three are used at the defrosting mode in four cases. As concluded, the melted frost influence on defrosting efficiency and metal energy storage effect would be increased from 4.87% to 10.45% and from 0.77% to 1.49%, respectively, after the outdoor coil changed from two- to three-working circuit. Outcomes of this study are meaningful for the structure optimization and energy saving of air source heat pump units at defrosting mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A one-dimensional model for frost formation on a cold flat surface
Lee, K.-S., Kim, W.-S., & Lee, T.-H. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(97)00074-4 · Cited by 296
Review on the measurement and calculation of frost characteristics
Song, M., & Dang, C. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.03.094 · Cited by 212
Self-citationYao, Y., Jiang, Y., Deng, S., & Ma, Z. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.03.013 · Cited by 196
Experimental study on frost growth and dynamic performance of air source heat pump system
Guo, X.-M., Chen, Y.-G., Wang, W.-H., & Chen, C.-Z. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2008.01.007 · Cited by 173
Frosting model for predicting macroscopic and local frost behaviors on a cold plate
Kim, D., Kim, C., & Lee, K.-S. (2015) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.11.048 · Cited by 103
State-of-the-art review of frost deposition on flat surfaces
Léoni, A., Mondot, M., Durier, F., Revellin, R., & Haberschill, P. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.04.004 · Cited by 103
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86
Liu, P., Rafati Nasr, M., Ge, G., Justo Alonso, M., Mathisen, H. M., Fathieh, F., & Simonson, C. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.007 · Cited by 81
Brèque, F., & Nemer, M. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.06.010 · Cited by 70
Modelling and experimental validation of the hot-gas defrost process of an air-cooled evaporator
Dopazo, J. A., Fernandez-Seara, J., Uhía, F. J., & Diz, R. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.12.027 · Cited by 55
Cited by
Zheng, H., Chang, S., Ma, G., & Wang, S. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110175 · Cited by 52
Xiong, T., Ying, Y., Han, B., Yan, G., & Yu, J. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.09.003 · Cited by 35
Menglong, L., Mengjie, S., Zhenjun, M., Xiaotao, W., & Long, Z. (2021) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2021.103749 · Cited by 25
Xiong, T., Chen, Q., Xu, S., Liu, G., Gao, Q., & Yan, G. (2024) · Energy · doi:10.1016/j.energy.2023.129968 · Cited by 21
Metadata
- Authors
- SONG, M., & MAO, N.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 214
- Pages
- 109809
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W3004574801
- Cited by
- 26
- References
- 11
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental study on the melted frost influence on the metal energy storage during an air source heat pump defrosting. https://app.cochat.ai/papers/10.1016/j.enbuild.2020.109809
- The paper
- SONG, M., & MAO, N. (2020). Experimental study on the melted frost influence on the metal energy storage during an air source heat pump defrosting. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2020.109809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.