The DOI matches its Crossref record; 112 of the 114 references it cites were found in a registry or an index.
How accurate is pulse rate variability as an estimate of heart rate variability?
Abstract
Background The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV.Methods We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography).Results/conclusions Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A comparative review of photoplethysmography against ECG stated that photoplethysmography can be used during rest but not during stress (Schafer and Vagedes, 2013).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Schafer and Vagedes, 2013
In the citing paper
“However, it cannot yet be considered to be a surrogate during exercise or stress [17], [129].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
In the citing paper
“Nonetheless, reviews have concluded that PRV is a good surrogate of HRV for certain applications at rest.”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Flagged first, then by citations
2 of the 114 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Herzman, 1937, Observations on the finger volume pulse recorded photoelectrically, Am J Physiol, 119, 334
- Janssen, 1994, Methods in heart rate variability analysis: may the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm?, High Blood Pressure, 3, 23
- Khandoker, 2011, Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea, Med Eng Phys, 33, 204, 10.1016/j.medengphy.2010.09.020 · DOI
Cited by
Sorted by citations
Items 401–500 of 660
Tan, C., Xiao, C., & Wang, W. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340871 · Cited by 6
“Recent research has shown a sufficient accuracy of PRV compared to HRV for healthy subjects at rest [2].”
BackgroundCitherlet, T., Raberin, A., Manferdelli, G., Bourdillon, N., & Millet, G. P. (2024) · High Altitude Medicine & Biology · doi:10.1089/ham.2024.0048 · Cited by 6
“HRV was derived from continuous BP measurements, as pulse rate variability has been shown to provide reliable results comparable with traditional HRV assessments under resting conditions (Schäfer and Vagedes, 2013).”
Kumar, S., Tayade, A., Shrivastava, A., & Ravi, B. (2025) · Scientific Reports · doi:10.1038/s41598-025-98488-w · Cited by 6
Ear and Finger PPG Wearables for Night and Day Beat-to-Beat Interval Detection
Haddad, S., Boukhayma, A., & Caizzone, A. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629602 · Cited by 6
“[2], for healthy subjects or subjects with regular heartbeats and for subjects with arrhythmia, such as atrial fibrillation (AF) [3], or different types of ectopic heartbeats [4].”
BackgroundTroughton, J. G., Brige, P., & Ramuz, M. P. (2023) · Biomedical Materials & Devices · doi:10.1007/s44174-022-00057-6 · Cited by 7
“However, a more accurate method is to find the systolic point by looking for the maximum gradient in the signal [63].”
Iacovella, V., Faes, L., & Hasson, U. (2018) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2018.03.005 · Cited by 8
“As documented by Schafer et al. (Schafer & Vagedes, 2013), the extensive literature about the agreement between PPGand ECG-based measures of HRV is not unequivocal.”
ResultUnique Characteristics of Heart Rate Variability Obtained from Pulse Wave Signals during Work
Yuda, E., Hayano, J., Tanabiki, T., Iwata, S., & Abe, K. (2019) · Journal of Advances in Information Technology · doi:10.12720/jait.10.4.131-136 · Cited by 6
“Second, the shape of the peaks changes with stroke volume, blood pressure, pulse wave velocity and the pressure reflection from peripheral vasculatures, which are affected by body posture, respiration, and emotions [18].”
BackgroundPatron, E., Munafò, M., Benvenuti, S. M., Stegagno, L., & Palomba, D. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00855 · Cited by 6
“, 2016) during resting conditions in the absence of motion (Schäfer and Vagedes, 2013; Menghini et al., 2019).”
BackgroundLogier, R., Jonckheere, J. D., Dassonneville, A., & Jeanne, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590855 · Cited by 6
“Total power of the signal is estimated by adding HF and LF contents [10].”
BackgroundMethodAge-related alterations in the sign series entropy of short-term pulse rate variability
Chou, Y., Zhang, A., & Yang, B. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.09.094 · Cited by 6
“In addition, a wide range of studies have shown that PRV can be a surrogate of HRV when the subjects are sleeping or resting, as well as in some non-stationary states [6,7].”
BackgroundBizzego, A., & Furlanello, C. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/118943 · Cited by 6
“Regarding HRV indicators the results confirmed that the BVP signals provide unreliable estimates, in particular for frequency domain indicators, as found in other studies [15].”
BackgroundMethodResultInfluentialNakagawa, N., & Sato, N. (2023) · Hypertension Research · doi:10.1038/s41440-023-01186-1 · Cited by 6
“On a related topic, the term “heart rate variability” (HRV), which seems similar to PRV, refers to the fact that the duration of the cardiac cycle varies from one heart beat to the next and the extent of variability is determined by the ECG signal [7].”
BackgroundStøve, M. P., & Larsen, B. T. (2020) · European Journal of Physiotherapy · doi:10.1080/21679169.2019.1628300 · Cited by 5
Farmer, G., & Lloyd, J. (2024) · Healthcare · doi:10.3390/healthcare12070772 · Cited by 7
“Nevertheless, this should not be confused with pulse rate variability, which measures changes around the mean and is not an estimate of IPR [55].”
BackgroundMethodBrown, R. D., Bondy, E., Prim, J., Dichter, G. S., & Schiller, C. E. (2024) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2024.1448914 · Cited by 7
Khatib, S., Palgi, Y., Ashar, Y. K., Polyvyannaya, N., & Goldstein, P. (2024) · Journal of Medical Internet Research · doi:10.2196/55042 · Cited by 5
“The following tools and instruments were used in this study: • Blood pressure, heart rate, and blood oxygen saturation were measured using the “Welch Allyn” measuring instrument, a commonly used tool in clinical and research settings [24].”
Ganeshmurthy, M. S., Periyasamy, R., & Joshi, D. (2025) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-025-01582-6 · Cited by 5
“Wear-able PPG-based sensors offer a promising alternative, capturing blood volume changes influenced by heartbeats and respiration [5, 6].”
Impact of signal length and window size on heart rate variability and pulse rate variability metrics
Uryga, A., Olszewski, B., Pietroń, D., & Kasprowicz, M. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adece2 · Cited by 5
“…the literature, HRV analysis lasting around 5 min reflects interactions between the sympathetic and parasympathetic branches, respiratory sinus arrhythmia modulation, the baroreceptor reflex regulation of blood pressure, and rhythmic adjustments in blood vessel diameter (Schäfer and Vagedes 2013).”
Cassani, R., Tiwari, A., & Falk, T. H. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175396 · Cited by 6
“It has been reported that these differences between PRV and HRV are due to differences in the underlying physiological processes, rather than only in an inaccurate pulse location [4].”
BackgroundInfluentialSpectral analysis for pulse rate variability assessment from simulated photoplethysmographic signals
Mejía‐Mejía, E., & Kyriacou, P. A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.966130 · Cited by 5
“It has been observed that stress and diseases affect PRV in a different way than HRV (Giardino et al., 2002; Charlot et al., 2009; Khandoker et al., 2011; Mejía-Mejía et al., 2021), whereas other aspects such as pulse transit time, external forces on the arteries and the different nature of ECG and PPG have also been…”
BackgroundMethodInfluentialWiśniewska, M., Piejka, A., Wolak, T. P., Scheele, D., & Okruszek, Ł. (2025) · Social Neuroscience · doi:10.1080/17470919.2025.2498384 · Cited by 7
“Furthermore, while PPG is considered sufficient for reliable HRV measurement, it is also more susceptible to motion artifacts (Schäfer & Vagedes, 2013), hence, its use instead of ECG resulted in lower signal accuracy.”
Nardelli, M., Greco, A., Vanello, N., & Scilingo, E. P. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630550 · Cited by 5
Farhan, A., Mouhsen, A., Labakoum, B., Rattal, M., & Lyazidi, A. (2024) · Biomedical & Pharmacology Journal · doi:10.13005/bpj/2873 · Cited by 5
Reproducibility of photoplethysmography-based local pulse transit time measurement
Beckmann, N., Viga, R., Doğangün, A., & Grabmaier, A. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036808 · Cited by 5
“95) [8].”
MethodA Signal Processing Method for Respiratory Rate Estimation through Photoplethysmography
Moreno, S., Quintero-Parra, A., Ochoa, C., Villarreal, R., & Kuzmar, I. (2018) · International Journal of Signal Processing Image Processing and Pattern Recognition · doi:10.14257/ijsip.2018.11.2.01 · Cited by 5
Quintanar-Gómez, J., Robles-Camarillo, D., Trejo-Macotela, F. R., & Campero-Jurado, I. (2021) · IEEE Latin America Transactions · doi:10.1109/tla.2021.9461853 · Cited by 5
“Ası́ mismo, la comunidad cientı́fica ha reportado una correlación entre el uso de PRV y HRV para la determinación de la frecuencia cardiaca [20], [21], estableciendo un tiempo de adquisición estándar de 180 segundos para la determinación de la frecuencia cardiaca [22], [23].”
BackgroundBachler, M., Mayer, C. C., Hametner, B., & Wassertheurer, S. (2013) · EUROSIM Congress on Modelling and Simulation (EUROSIM) · doi:10.1109/eurosim.2013.18 · Cited by 5
A Smart Clothe for ECG Monitoring of Children with Autism Spectrum Disorders
Takahashi, K., Matsuda, S., & Suzuki, K. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-41264-1_75 · Cited by 5
A pilot study: Can heart rate variability (HRV) be determined using short-term photoplethysmograms?
Elgendi, M., Norton, I., Brearley, M. B., Dokos, S., Abbott, D., & Schuurmans, D. (2016) · F1000Research · doi:10.12688/f1000research.9556.1 · Cited by 5
“However, HRV calculated from PPG signal has been proved to be sufficiently accurate only for healthy (and mostly younger) subjects at rest [22].”
Emotional State Recognition with Micro-expressions and Pulse Rate Variability
Belaiche, R., Sabour, R. M., Migniot, C., Benezeth, Y., Dominique Ginhac, B., Nakamura, K., Gómez, R., & Yang, F. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-30642-7_3 · Cited by 5
“Both HRV and PRV describe changing heart beat rhythms, and multiple researches have demonstrated similarity between PRV and HRV [13, 14].”
Using Psychophysiological Parameters to Support Users in Setting Effective Activity Goals
Herrmanny, K., Beckmann, N., Nachbar, K., Sauer, H., Ziegler, J., & Doğangün, A. (2016) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/2851581.2892378 · Cited by 5
“However, particularly in rest conditions high correlation compared to the “gold standard” (Electrocardiography) can be achieved [13].”
Diehl, K. J., Scott, B. G., & McCullen, J. R. (2021) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.06.005 · Cited by 5
Regalia, G., Resnati, D., & Tognetti, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00130-8 · Cited by 9
Assessing Garmin’s Stress Level Score Against Heart Rate Variability MeasurementsPreprint
Rosenbach, H., Itzkovitch, A., Gidron, Y., & Schönberg, T. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.01.06.630177 · Cited by 6
Citherlet, T., Mota, G. R., Carletta, M., Hayoz, K., Pereira, D., & Millet, G. P. (2025) · Scientific Reports · doi:10.1038/s41598-025-10550-9 · Cited by 4
“HRV was derived from continuous blood pressure measurements, as pulse rate variability has demonstrated comparable reliability to traditional HRV assessments under resting conditions 28 .”
Sah, R. K., Rahman, M. M., Nathan, V., Zhu, L., Bae, J., Rosa, C., Mendes, W. B., Kuang, J., & Gao, A. J. (2024) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp48485.2024.10447778 · Cited by 4
“The IBI out-lier detection algorithm proposed in [7, 17] for ECG signals can be used for PPG signals because RR-intervals from ECG are found to align closely with PP-intervals from PPG signals [18, 19].”
MethodTiny ML-based Non-Invasive Approach of Cardiac Monitoring
Vivekanand, C. V., Purushothaman, R., Inbamalar, T. M., Kushbu, S. C., & Selvam, M. (2024) · International Conference on Contemporary Computing and Informatics (IC3I) · doi:10.1109/ic3i61595.2024.10828932 · Cited by 4
“One of the commonly used surrogate metrics is the pulse rate variability, which provides valuable insights into the autonomic nervous system and can be indicative of stress levels, physical exertion, and overall cardiovascular fitness [4].”
Pustovoit, V. I., Сергеевич, К. М., Nazaryan, S. E., Eroyan, I. A., & Samojlov, A. S. (2021) · Современные вопросы биомедицины · doi:10.51871/2588-0500_2021_05_02_4 · Cited by 4
Predicting Heart Rate Variability Parameters in Healthy Korean Adults: A Preliminary Study
Kim, S.-W., Park, H., Jung, W., & Lim, K. (2021) · INQUIRY The Journal of Health Care Organization Provision and Financing · doi:10.1177/00469580211056201 · Cited by 4
Learning Attention Level Prediction via Multimodal Physiological Data Using Wearable Wrist Devices
Gao, S., Lai, S., & Wu, F. (2022) · International Conference of Educational Innovation through Technology (EITT) · doi:10.1109/eitt57407.2022.00008 · Cited by 4
“As for the HRV measurement method, the heartbeat interval change and continuous pulse cycle change are generally measured [20].”
MethodHeart Rate Extraction From Neonatal Near-Infrared Spectroscopy Signals
Hakimi, N., Horschig, J. M., Alderliesten, T., Bronkhorst, M., Floor, M., van Bel, F., Colier, W. N. J. M., & Dudink, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3295015 · Cited by 4
Changes in beat-to-beat blood pressure and pulse rate variability following stroke
Abiri, A., Chou, E., Shen, W., Fisher, M., & Khine, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-45479-4 · Cited by 4
“…those of Wang et al. Furthermore, it is important to note that our analyses used PRV, which has been reported to behave differently than HRV in some clinical contexts and slightly overestimate short-term variability due to coupling effects between respiration and the cardiovascular system 39,66 .”
MethodDervishi, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-57971-6 · Cited by 4
Sakuragi, M., Shinagawa, K., Terasawa, Y., & Umeda, S. (2024) · Consciousness and Cognition · doi:10.1016/j.concog.2024.103770 · Cited by 6
Development and Optimisation of Textile-Based Optical Sensors for Cardiac Health Monitoring
Peiris, T., Shahidi, A. M., Koutsogeorgis, D. C., Hurley, W., de Oliveira, C. R. M., Dias, T., & Riley, T. H. (2024) · International Conference on the Challenges, Opportunities, Innovations and Applications in Electronic Textiles (E-Textiles) · doi:10.23919/e-textiles63767.2024.10914070 · Cited by 4
Masitoh, Y., Wuryandari, A. I., & Mardiono, T. (2015) · International Conference on Interactive Digital Media (ICIDM) · doi:10.1109/idm.2015.7516326 · Cited by 4
Comparing inter beat and inter pulse intervals from ECG and PPG signals
Nano, M.-M., Papini, G. B., Fonseca, P. P., Vullings, R., Overeem, S., Bergmans, J. J., & Aarts, R. M. (2017) · TU/e Research Portal · Cited by 4
Tochinai, R., Sekizawa, S., KOBAYASHI, H., & Kuwahara, M. (2021) · Translational and Regulatory Sciences · doi:10.33611/trs.2021-001 · Cited by 4
Alternative Devices for Heart Rate Variability Measures: A Comparative Test–Retest Reliability Study
Killian, J. M., Radin, R. M., Gardner, C. L., Kasuske, L., Bashirelahi, K., Nathan, D. E., Keyser, D. O., Cellucci, C. J., Darmon, D. M., & Rapp, P. E. (2021) · Behavioral Sciences · doi:10.3390/bs11050068 · Cited by 4
“The measurement reliability results of this investigation are concordant with published literature comparing methods of assessing HRV [4,22,23], and suggest that the assessed devices are equally capable of collecting valid measures in normal healthy subjects.”
ResultHeart Rate Variability as a Potential Non-invasive Marker of Blood Glucose Level
Jarman, L. R., Elliott, J. L., Lees, T., Clifton-Bligh, R. J., Simpson, A. M., Nassif, N. T., & Lal, S. (2021) · Human Physiology · doi:10.1134/s0362119721020031 · Cited by 4
Analysis and Comparison of Heart Rate Variability Signals Derived from PPG and ECG Sensors
Królak, A., & Pilecka, E. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-83704-4_2 · Cited by 4
Detection of Drowsiness Using the Pulse Rate Variability of Finger
Heydari, S., Ayatollahi, A., Najafi, A., & Poorjafari, M. (2022) · SN Computer Science · doi:10.1007/s42979-022-01247-1 · Cited by 4
“Some studies have been done to replace the HRV with the PRV since the pulse rate is more easily obtained compared to the heart rate [7, 10, 15].”
BackgroundLong- and short-term fluctuations compared for several organ systems across sleep stages
Zschocke, J., Bartsch, R. P., Glos, M., Penzel, T., Mikolajczyk, R., & Kantelhardt, J. W. (2022) · Frontiers in Network Physiology · doi:10.3389/fnetp.2022.937130 · Cited by 4
“Furthermore, we found a close similarity between HRV parameters (from RRI, top row in Figure 2) and pulse rate variability parameters (from PPI, second row in Figure 2), confirming our Hypothesis 3 from the Introduction.”
BackgroundResultInfluentialChannel Intensity and Edge-Based Estimation of Heart Rate via Smartphone Recordings
Krishnamoorthy, A., Bairy, G. M., Siddeshappa, N., Mayrose, H., Sampathila, N., & Chadaga, K. (2023) · Computers · doi:10.3390/computers12020043 · Cited by 4
Balaraman, K., & Claret, S. P. A. (2023) · International Conference on Circuit, Power and Computing Technologies · doi:10.1109/iccpct58313.2023.10245666 · Cited by 4
“Transmission-type PPG sensor [5] Examined existing research on Pulse rate variability (PRV) accuracy measurement Pulse Oximeter (PPG), [6] Wearable device-based PPG monitoring technologies are utilized to observe current advancements and problems.”
MethodAn improved algorithm for the detection of photoplethysmographic percussion peaks
Luo, F., Li, J., Yun, F., Chen, T., & Chen, X. C. (2014) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp.2014.7003906 · Cited by 4
“…of Life Science and Technology, Xi'an Jiaotong University, Xi’an, Shaanxi, P.R.China 2 Solid State Lighting Engineering Research Center, Xi'an Jiaotong University, Xi’an, Shaanxi, P.R.China 3 The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi’an,…”
BackgroundInfluentialThe factors influence compatibility of pulse-pulse intervals with R-R intervals
Liu, A., Wu, H., Liu, C.-C., Hsu, C.-H., & Chen, D.-Y. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609939 · Cited by 4
Real-time heart activity monitoring with optical illusion using a smartphone
Thap, T., Chung, H., Jeong, C., Ryu, J., Nam, Y., Yoon, K., & Lee, J. (2017) · Multimedia Tools and Applications · doi:10.1007/s11042-017-4530-3 · Cited by 4
“Many applications on smartphones for out-of-clinic patient use have been released with peripheral medical devices that plug into or arewirelessly connected to a smartphone [18, 20, 25, 30, 34, 36].”
BackgroundProkhorov, M. D., Kulminskiy, D. D., Borovkova, E. I., Karavaev, A. S., Пономаренко, В. И., Kiselev, A. R., & Bezruchko, B. P. (2018) · The Open Hypertension Journal · doi:10.2174/1876526201810010046 · Cited by 4
Shaffer, F. (2020) · Biofeedback · doi:10.5298/1081-5937-48.01.06 · Cited by 4
Pelz, H., Keller, M., Müller, G., Mathiak, K., Borik, Š., Mayer, J., & Perlitz, V. (2022) · Research Square · doi:10.21203/rs.3.rs-2409912/v1 · Cited by 4
Philippi, C. L., Weible, E., Ehlers, A., Walsh, E. C., Hoks, R. M., Birn, R. M., & Abercrombie, H. C. (2024) · Behavioural Brain Research · doi:10.1016/j.bbr.2024.114923 · Cited by 4
A lightGBM-based method for the signal quality assessment of wrist photoplethysmography
Wang, J., Hui, H., Yang, H., Pengfei, X., & Ji, Z. (2025) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-025-01616-z · Cited by 3
“Beyond fundamental pulse rate detection, pulse rate variability (PRV) serves as a valid surrogate for heart rate variability, reflecting autonomic nervous system activity [ 14, 15 ].”
The cardiac rhythm invariance Principle: A unified framework for multimodal cardiac signal analysis
Abdessalem, K. B. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.109148 · Cited by 4
Xu, D., & Albeaino, G. (2025) · Journal of Information Technology in Construction · doi:10.36680/j.itcon.2025.075 · Cited by 3
Biomedical Signal Processing: The Cornerstone of Artificial Intelligence in Healthcare Wearables
Valenza, G. (2022) · Biomedical Materials & Devices · doi:10.1007/s44174-022-00051-y · Cited by 4
Ajtay, B. E., Béres, S., & Hejjel, L. (2023) · Applied Sciences · doi:10.3390/app13095642 · Cited by 3
Saito, I., Maruyama, K., Yamauchi, K., Funakoshi, Y., Kato, T., Kawamura, R., Takata, Y., & Osawa, H. (2024) · Scientific Reports · doi:10.1038/s41598-024-54748-9 · Cited by 3
Krylova, M., Alizadeh, S., Jamalabadi, H., Izyurov, I., Chand, T., van der Meer, J. N., Vester, J., Naschold, B., Schultz, M., Engert, V., et al. (2025) · Human Psychopharmacology Clinical and Experimental · doi:10.1002/hup.70020 · Cited by 3
“PPG serves as a well‐ established alternative to ECG for HRV evaluations, particularly under resting state conditions (Lu et al. 2009; Podaru et al. 2018; Schäfer and Vagedes 2013).”
Accuracy of pulse interval timing in ambulatory blood pressure measurement
Kane, S., Blake, J. R., McArdle, F., Langley, P., & Sims, A. (2016) · Scientific Reports · doi:10.1038/srep37472 · Cited by 3
Evaluation of a real-time low-power cardiorespiratory sensor for the IoT
Gatouillat, A., Massot, B., Badr, Y., Sejdić, E., & Géhin, C. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513550 · Cited by 3
“This paper only focuses on the development and evaluation of ECG-based cardiac activity sensor systems, as the reliability of other techniques such as photoplethysmography are sometimes challenged by the medical community [4].”
MethodAmado-Fuentes, M., Delgado, M. G., Gómez, A. G., & My works are correct, B. M. I. A. A. I. S. R. L. M. T. I. D. A.-M. (2021) · Children · doi:10.3390/children8111073 · Cited by 4
“Concerning each participant: • Participant 1, who performed the EAIs without riding, showed a great magnitude of effect, with an increase in HRV before the session and lower stress levels after the EAI intervention.”
MethodInfluentialErnst, G. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4309-3_4 · Cited by 3
A wearable heart rate monitoring system based on over-ear headphones
Voropai, A., & Sarana, V. (2022) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2022.2080884 · Cited by 3
“These alternative methods are indirect ways of registering heart activity, they can’t provide ECG level accuracy [5].”
MethodCao, Y., Zhao, X., Yang, Y., Zhu, S., Zheng, L.-D., Ying, T., Sha, Z., Zhu, R., & Wu, T. (2023) · Geriatric Nursing · doi:10.1016/j.gerinurse.2023.02.007 · Cited by 3
Zhang, X., Long, K., Wang, N., Zhang, J., & Hao, L. (2023) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545823400059 · Cited by 3
Affective gaming using adaptive speed controlled by biofeedback
Frachi, Y., Chanel, G., & Barthet, M. (2023) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/3610661.3616124 · Cited by 3
“Results were confrmed by Schafer (2013) and his review of studies [22].”
BackgroundEvidence-Based Clinical Utility of Heart Rate Variability Across Populations, Including Long COVID
Steere, K. B. (2024) · Cardiopulmonary Physical Therapy Journal · doi:10.1097/cpt.0000000000000270 · Cited by 3
ECG changes in patients with opioid use disorder; P-QT wave dispersion: a retrospective study
Demir, B., Özsoy, F., Büyük, A., & Altındağ, A. (2020) · Journal of Addictive Diseases · doi:10.1080/10550887.2020.1848257 · Cited by 3
“In another study, it was found that the heart rate of patients with generalized anxiety disorder was higher than the healthy controls, but the result obtained did not show a statistically significant difference.(26) In a study conducted on patients diagnosed with heroin use disorder, it was shown that the heart rates…”
ResultMollura, M., Polo, E. M., Lehman, L.-W. H., & Barbieri, R. (2020) · Computing in cardiology · doi:10.22489/cinc.2020.423 · Cited by 3
“Previous studies [8, 9] have analyzed the possibility of using Pulse Rate Variability (PRV) to replace specific HRV features under different conditions.”
BackgroundResultTowards efficient heart rate variability estimation in artifact-induced Photoplethysmography signals
Alqaraawi, A., Alwosheel, A., & Alasaad, A. (2016) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2016.7726853 · Cited by 3
“Schfer et al. conducted a survey of methods used for detecting peaks [11].”
MethodNail tip sensor: Toward reliable daylong monitoring of heart rate
Ishii, K., & Hiraoka, N. (2020) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23132 · Cited by 3
Mejía‐Mejía, E., Budidha, K., Abay, T. Y., May, J. M., & Kyriacou, P. A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175856 · Cited by 3
“PRV has been found to be influenced by technical factors, such as the fiducial points used for measuring the cardiac cycles [8], and the sampling rate of the PPG signal [9]; as well as by physiological aspects, such as the variability of the pulse transit time [10], the nature of the PPG and ECG signals [7], and chang…”
BackgroundInfluentialExtremely Lightweight Skin Segmentation Networks to Improve Remote Photoplethysmography Measurement
Lee, K., You, H., Oh, J., & Lee, E. C. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-27199-1_45 · Cited by 3
Zawadzka, S., & Sondej, T. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108055 · Cited by 2
Sun, Y., Li, S. S., Sun, W., Jin, T., Guo, M., Fu, M., Liu, D., & Huang, X. M. (2025) · Measurement · doi:10.1016/j.measurement.2025.120051 · Cited by 2
Li, Z., Chen, S., Rietzschel, E. R., Kozusznik, M. W., Hoecke, S. V., Vanderhasselt, M., & Pulopulos, M. M. (2025) · Applied Psychology Health and Well-Being · doi:10.1111/aphw.70107 · Cited by 2
Younis, S. M. A., Awad, M. I., Katmah, R., Alskafi, F. A., Jelinek, H. F., & Khalaf, K. A. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3658402 · Cited by 2
“Following peak detection, the signals were down-sampled to 4 Hz to comply with conventional HRV analysis guidelines and reduce the computing load without eliminating key temporal information [42], [43].”
Woelk, S. P., Garfinkel, S. N., Mayiwar, L., & Knöferle, K. (2026) · Behavior Research Methods · doi:10.3758/s13428-026-02953-x · Cited by 2
“An alternative method for collecting cardiac data is photoplethysmography (PPG) (Gil et al., 2010; Schäfer & Vagedes, 2013).”
Slow breathing impacts inter-organ dynamics modulating brain function and risk behavior
Huang, W., Schmidt, M., Rebollo, I., Molter, F., Pu, M., Keweloh, B., Lam, L. Y., Mohr, P. N. C., Bellucci, G., Röttger, S., et al. (2026) · Neuron · doi:10.1016/j.neuron.2026.04.044 · Cited by 2
Wang, H., Jimison, H., & Misha Pavel, C. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630551 · Cited by 2
“In the case of PPG, beat by beat heart period data can be can be obtained by detecting systolic peaks of the PPG signal [9].”
Erkudov, V. O., Pugovkin, A., Rozumbetov, K. U., Матчанов, А. Т., Arachchi, S., & Rathnayake, U. (2024) · Case Studies in Chemical and Environmental Engineering · doi:10.1016/j.cscee.2024.100619 · Cited by 2
Klassen, S. A., Jabbar, J., Osborne, J., Iannarelli, N. J., Kirby, E. S., O’Leary, D. D., & Locke, S. (2024) · JMIR Formative Research · doi:10.2196/56921 · Cited by 2
“Accordingly, to extend HRV measures beyond laboratory and clinical environments, methods have been developed that rely on photoplethysmography (PPG) to measure pulse interval from the pulsatile changes in microcirculatory blood volume in an accessible anatomical location such as a finger [11].”
MethodInnovative Pulse Monitoring: Exploring Auscultation-Based Diagnostic Technique
Kumar, S., Tayade, A., Kumar, P., & Ravi, B. (2024) · International Conference on Biomedical and Bioinformatics Engineering (ICBBE) · doi:10.1145/3707127.3707146 · Cited by 2
“In recent years, Pulse Rate Variability (PRV) has been used as a surrogate for HRV, and studies have shown a high correlation between PRV and HRV when measurements are taken at rest [12].”
Adib, N., Setarehdan, S. K., Tondashti, S. A., & Yaghoubi, M. (2025) · Journal of Medical Signals & Sensors · doi:10.4103/jmss.jmss_48_24 · Cited by 2
“[17] Numerous studies have aimed to measure HR and HRV using fNIRS signals.”
InfluentialKhalili, M., Lingawi, S., Hutton, J., Christenson, J. M., Shadgan, B., Grunau, B. E., & Kuo, C. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253258 · Cited by 3
Autonomic Modulation During a Cognitive Task Using a Wearable Device
Bonomini, M. P., Val-Calvo, M., Díaz‐Morcillo, A., Vicente, J. M. F., & Fernández-Jover, E. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-19591-5_8 · Cited by 3
Comparison of Heart Rate Variability and Pulse Rate Variability of Respiratory Control
Han, Y., Lin, W., Huang, S., Tsai, C.-L., & Lin, K. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-4505-9_44 · Cited by 2
Effects of Astaxanthin on Pulse Rate Variability of Mice Under Chronic Stress
Escutia-Reyes, D., Oros‐Pantoja, R., Lagos, J. J. R., Pliego‐Carrillo, A. C., Ramírez, C. I. L., Rodríguez-Muñoz, D., & García, E. T. (2019) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-30648-9_95 · Cited by 2
Ilie, A. C., Costin, H. N., Pîslaru, A. I., Alexa‐Stratulat, T., Rotariu, C., Sandu, I. A., Costin, D., & Alexa, I. D. (2019) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb47216.2019.8970043 · Cited by 2
Metadata
- Authors
- Schäfer, A., & Vagedes, J.
- Affiliations
- Academic Research in Complementary and Integrative Medicine (DE)
- University Children's Hospital Tübingen (DE)
- Corresponding author
- Vagedes, Jan
- ORCID
- Vagedes, Jan
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 166
- Issue
- 1
- Pages
- 15-29
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W188715143
- Cited by
- 661
- References
- 114
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 56 · 2023: 52 · 2022: 57 · 2021: 72 · 2020: 67 · 2019: 49 · 2018: 59 · 2017: 40 · 2016: 40 · 2015: 29 · 2014: 19 · 2013: 9
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- pulse rate variability, heart rate variability, photoplethysmography, pulse oximetry, RR interval, measurement accuracy, physical activity, psychological stress, sensor position, detection algorithm, ambulatory monitoring
- MeSH terms
- Electrocardiography, Heart Rate, Humans, Motor Activity, Pulse, Rest, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review