How accurate is pulse rate variability as an estimate of heart rate variability?
Abstract
Background The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV.Methods We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography).Results/conclusions Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A comparative review of photoplethysmography against ECG stated that photoplethysmography can be used during rest but not during stress (Schafer and Vagedes, 2013).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Schafer and Vagedes, 2013
In the citing paper
“However, it cannot yet be considered to be a surrogate during exercise or stress [17], [129].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
In the citing paper
“Nonetheless, reviews have concluded that PRV is a good surrogate of HRV for certain applications at rest.”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Flagged first, then by citations
2 of the 114 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Herzman, 1937, Observations on the finger volume pulse recorded photoelectrically, Am J Physiol, 119, 334
- Janssen, 1994, Methods in heart rate variability analysis: may the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm?, High Blood Pressure, 3, 23
- Khandoker, 2011, Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea, Med Eng Phys, 33, 204, 10.1016/j.medengphy.2010.09.020 · DOI
Cited by
Sorted by citations
Items 301–400 of 660
Brun, R., Girsberger, J., Rothenbühler, M., Argyle, C., Hutmacher, J., Haslinger, C., & Leeners, B. (2022) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-022-06753-4 · Cited by 13
Holper, L., Seifritz, E., & Scholkmann, F. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091308 · Cited by 13
“Previous studies comparing PRV derived from PPG and ECG under optimal rest conditions did not report significant differences in PRVassessment.6,45,46 However, studies that compared PPG and ECG under less optimal conditions have shown that PRVPPG assessed the parameters of short-term variability (HF, RMSSD, and SD1) co…”
ResultInfluentialThe Physiological Response to Drawing and Its Relation to Attention and Relaxation
Loudon, G. H., & Deininger, G. M. (2017) · Journal of Behavioral and Brain Science · doi:10.4236/jbbs.2017.73011 · Cited by 13
“The motivation behind this last objective was because these new HR sensors, using techniques such as Photoplethysmography, are becoming commonly available on the market and provide a simpler and more convenient way of estimating HRV.”
MethodA Learning Attention Monitoring System via Photoplethysmogram Using Wearable Wrist Devices
Li, Q., Ren, Y., Wei, T., Wang, C., Liu, Z., & Yue, J. (2020) · Advances in analytics for learning and teaching · doi:10.1007/978-3-030-41099-5_8 · Cited by 13
Heart rate entropy is associated with mortality after intracereberal hemorrhage.
Sykora, M., Szabó, J., Šiarnik, P., Turčáni, P., Krebs, S., Lang, W., Czosnyka, M., & Smielewski, P. (2020) · Journal of Neurological Sciences · doi:10.1016/j.jns.2020.117033 · Cited by 11
Alquadan, K. F., Singhania, G., Koratala, A., & Ejaz, A. A. (2017) · Clinical Hypertension · doi:10.1186/s40885-016-0059-4 · Cited by 13
“Although comprehensive investigations of all heart rate variability indices in large populations have yet to be performed, recent report suggests sufficient accuracy between them [28].”
BackgroundStøve, M. P., Holm, R. S., Kjaersgaard, A. S., Duncker, K., Jensen, M. R., & Larsen, B. T. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1753836 · Cited by 12
“However, wearable devices are also increasingly used to monitor elderly or disabled patients in rehabilitation conditions [34,35] to ensure that the exercise activity is safe, attainable and adequate to elicit a training effect [36].”
BackgroundBrief induction of loneliness decreases vagal regulation during social information processing
Piejka, A., Wiśniewska, M., Thayer, J. F., & Okruszek, Ł. (2021) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.03.002 · Cited by 13
Tracking white-matter brain modifications in chronic non-bothersome acoustic trauma tinnitus
Jaroszynski, C., Attyé, A., Job, A., & Delon‐Martin, C. (2021) · NeuroImage Clinical · doi:10.1016/j.nicl.2021.102696 · Cited by 10
Simons, R., Koordeman, R., de Looff, P. C., & Otten, R. (2021) · JMIR Research Protocols · doi:10.2196/24911 · Cited by 12
A video-game-based method to induce states of high and low flow
Joëssel, F., Pichon, S., & Bavelier, D. (2023) · Behavior Research Methods · doi:10.3758/s13428-023-02251-w · Cited by 16
“…of heart rate variability has shown that measures from PPG can be used as surrogates for measures derived from an ECG with sufficient reliability in contexts that do not involve exercise or participants with cardiovascular diseases, i.e., such as in the present study (Schäfer & Vagedes, 2013).”
Iovino, M., Lazić, I., Lončar-Turukalo, T., Javorka, M., Pernice, R., & Faes, L. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad9234 · Cited by 12
“…the robustness and reliability of the analysis and demonstrates the viability of substituting features derived from HRV by the ones from PRV, confirming previous findings obtained in other works with classical statistical analyses (Schäfer and Vagedes 2013, Hernando et al 2018, Pernice et al 2019).”
Tigges, T., Büchler, T., Pielmuş, A., Klum, M., Feldheiser, A., Hunsicker, O., & Orglmeister, R. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9038-7_54 · Cited by 12
A Real-Time Analysis Method for Pulse Rate Variability Based on Improved Basic Scale Entropy
Chou, Y., Zhang, R., Feng, Y., Lu, M., Lu, Z., & Xu, B. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/7406896 · Cited by 12
Towards pulse rate parametrization during free-living activities using smart wristband
Rapalis, A., Petrėnas, A., Šimaitytė, M., Bailón, R., & Marozas, V. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac24a · Cited by 11
Pulse Wave Analysis During Sleep
Grote, L., & Zou, D. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-24288-2.00167-7 · Cited by 12
Herzfrequenzvariabilität – Stand der Forschung und klinische Anwendbarkeit
Fouradoulas, M., von Känel, R., & Schmid, J. (2019) · Praxis · doi:10.1024/1661-8157/a003206 · Cited by 12
Pulse Rate Variability in Emergency Physicians During Shifts: Pilot Cross-Sectional Study
Peters, G. A., Wong, M. L., Joseph, J. W., & Sánchez, L. D. (2019) · JMIR mhealth and uhealth · doi:10.2196/13909 · Cited by 12
“The adequacy of PRV as a surrogate for HRV remains controversial [26-31], and to the knowledge of this author’s group, no studies have been published to evaluate the suitability of PRV analysis to study physician wellness.”
BackgroundComparison of Pulse Rate Variability and Heart Rate Variability for Hypoglycemia Syndrome
Çelik, G., Yıldırım, M., Ilhan, M., Karaman, Ö., Taşan, E., Kara, S., & Okkesim, Ş. (2016) · Methods of Information in Medicine · doi:10.3414/me15-01-0088 · Cited by 11
Zhang, J., Li, W., Braithwaite, G. R., & Blundell, J. (2024) · Stress · doi:10.1080/10253890.2024.2361253 · Cited by 14
“…2016). however, an increasing number of studies further investigated the agreement between hRV taken by ecG and PPG (e.g., Morelli et al., 2018; schäfer & Vagedes, 2013); the results demonstrated sufficient accuracy of using PPG to measure short-term hRV reflecting coupling effects between…”
A wireless, low-power, smart sensor of cardiac activity for clinical remote monitoring
Massot, B., Risset, T., Michelet, G., & McAdams, E. T. (2015) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2015.7454552 · Cited by 11
“Most of these systems suffers from a lack of accuracy, depending on the sensing method used (for example, plethysmography which appears to be still questionable for instantaneous HR and short-term HRV and also suffers from many motion artefacts in ambulatory conditions [9]), and on the calculation methods (for example…”
BackgroundBeckers, A. B., Oudenhove, L. V., Weerts, Z. Z. R. M., Jacobs, H. I. L., Priovoulos, N., Poser, B. A., Ivanov, D., Gholamrezaei, A., Aziz, Q., Elsenbruch, S., et al. (2021) · Pain · doi:10.1097/j.pain.0000000000002538 · Cited by 11
“Although the RMSSD is generally calculated from electrocardiogram data, it can also be calculated accurately from PPG data in healthy subjects at rest.(30)Marginal linear mixedmodels (SAS procmixed) were used to compare RMSSD change from baseline between conditions using SAS 9.”
MethodDanilin, L. K., Spindler, M., Sörös, P., & Bantel, C. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05009-1 · Cited by 10
Can accelerometry data improve estimates of heart rate variability from wrist pulse PPG sensors?
Kos, M., Li, X., Far, I. K., Gordon, C. M., Misha Pavel, C., & Jimison, H. B. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037141 · Cited by 11
“Following previous research [30], we used the concordance correlation coefficient [31], which we computed over a 1minute rolling window, because it accounts for systematic bias in HR and the lack of linear correlation.”
MethodA low-complexity photoplethysmographic systolic peak detector for compressed sensed data
Poian, G. D., Letizia, N. A., Rinaldo, R., & Clifford, G. D. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab254b · Cited by 11
“As reported in Schäfer and Vagedes (2013), PRV is typically sufficiently accurate, although coupling effects between respiration and the cardiovascular system leads to an overestimation of the short-term variability.”
BackgroundResultKoskimäki, H., Kinnunen, H. O., Rönkä, S., & Smarr, B. L. (2019) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3341162.3344836 · Cited by 11
Sahroni, A., Hassya, I. A., Rifaldi, R., Jannah, N. U., Irawan, A. F., & Rahayu, A. W. (2019) · Procedia Computer Science · doi:10.1016/j.procs.2019.11.153 · Cited by 11
Sternal pulse rate variability compared with heart rate variabilit on healthy subjects
Chreiteh, S. S., Belhage, B., Hoppe, K., Branebjerg, J., & Thomsen, E. V. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944351 · Cited by 11
“[12] reported that an approach to place a PPG sensor on a more central location could be beneficial for the assessment of the cardiac autonomic tone.”
BackgroundMethodInfluentialEstimating Resting HRV during fMRI: A Comparison between Laboratory and Scanner Environment
Schumann, A., Suttkus, S., & Bär, K. (2021) · Sensors · doi:10.3390/s21227663 · Cited by 10
“A meta-analysis by Schäfer and Vagedes (2013) concluded on the ‘sufficient accuracy’ of HRV derived from the finger pulse, especially during the resting condition [24].”
BackgroundMethodVenezia, A., Fawsitt‐Jones, H., Hohenschurz‐Schmidt, D., Mancini, M., Howard, M. A., & Makovac, E. (2024) · The Journal of Physiology · doi:10.1113/jp286375 · Cited by 10
“Some studies have shown that, under certain conditions, PPG can serve as a suitable alternative to ECG (Bolanos et al., 2006; Schäfer & Vagedes, 2013).”
Maniaci, G., Daino, M., Iapichino, M., Giammanco, A., Taormina, C., Bonura, G., Sardella, Z., Carolla, G., Cammareri, P., Sberna, E., et al. (2024) · Stress and Health · doi:10.1002/smi.3503 · Cited by 14
Beat-to-Beat Detection Accuracy Using the Ultra Low Power Senbiosys PPG Sensor
Haddad, S., Boukhayma, A., & Caizzone, A. (2020) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-64610-3_21 · Cited by 10
Elshafei, M., Costa, D. E., & Shihab, E. (2022) · Sensors · doi:10.3390/s22041454 · Cited by 15
Sabil, A., Blanchard, M., Annweiler, C., Bailly, S., Goupil, F., Pigeanne, T., Trzépizur, W., Gervès‐Pinquié, C., Gagnadoux, F., & the Pays de la Loire Sleep Cohort study group (2022) · Journal of the American Geriatrics Society · doi:10.1111/jgs.17933 · Cited by 10
“PRV is an accurate estimation of HRV in subjects at rest or in non-stationary conditions as well as during sleep.(36,37) Contrary to data obtained in the general population where a lower HRV was associated with MND regardless of recording time (day or night),(38,39) the risk of MND increased in our OSA cohort along wi…”
ResultFuadah, Y. N., & Lim, K. M. (2022) · Diagnostics · doi:10.3390/diagnostics12112886 · Cited by 13
Sinha, M. K., Vaishali, K., Maiya, A. G., Shivashankar, K. N., & Shashikiran, U. (2023) · F1000Research · doi:10.12688/f1000research.139283.1 · Cited by 10
“The term compatibility between PRV and HRV characteristics is a subject of interest for current research, due to its frequent use in clinical and everyday situations, researchers have tried to extract as much information as possible from pulse signals to understand the similarity between PRV and HRV characteristics.(1…”
ResultRespiratory muscle training positively affects vasomotor response in young healthy women
Bisconti, A. V., Devoto, M., Venturelli, M., Bryner, R. W., Olfert, I. M., Chantler, P. D., & Esposito, F. (2018) · PLoS ONE · doi:10.1371/journal.pone.0203347 · Cited by 10
Antink, C. H., Leonhardt, S. K., & Walter, M. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512908 · Cited by 10
“If the usage of CLIE is not possible or desired, T2T will give the most accurate results for high-quality signals, outperforming P2P, which is often used [5].”
BackgroundMethodEffects of R-R time series accuracy on heart rate variability indexes
Cassirame, J., Chevrolat, S., & Mourot, L. (2019) · Movement & Sport Sciences - Science & Motricité · doi:10.1051/sm/2019006 · Cited by 10
Georgiou, K. E., Dimov, R. K., Boyanov, N. B., Zografos, K. G., Larentzakis, A. V., & Marinov, B. I. (2019) · Folia Medica · doi:10.2478/folmed-2019-0001 · Cited by 10
Rubaltelli, E., Priolo, G., Scrimin, S., & Moscardino, U. M. M. (2020) · Risk Analysis · doi:10.1111/risa.13498 · Cited by 11
“To obtain a measure of HRV, we registered HR, through photoplethysmography, a simple and noninvasive technique used to detect blood volume pulse (BVP) (Schäfer & Vagedes, 2013).”
MethodPratap, A., Steinhubl, S. R., Neto, E. C., Wegerich, S., Peterson, C. T., Weiss, L., Patel, S., Chopra, D., & Mills, P. J. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00120 · Cited by 11
Meeuwsen, K. D., Groeneveld, K. M., Walker, L. A., Mennenga, A. M., Tittle, R. K., & White, E. K. (2020) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-201053 · Cited by 14
Wearable photoplethysmography devices
Charlton, P. H., & Marozas, V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00011-6 · Cited by 10
Pulse rate variability in children with disordered breathing during different sleep stages
Dehkordi, P., Garde, A., Karlen, W., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2013) · Cited by 10
Insomnia and Autonomic Function Predict Well-Being in Patients Receiving Palliative Care
Warth, M., Keßler, J., & Bardenheuer, H. J. (2017) · Journal of Palliative Medicine · doi:10.1089/jpm.2017.0032 · Cited by 10
Comparing Real-Time Self-Tracking and Device-Recorded Exercise Data in Subjects with Type 1 Diabetes
Groat, D., Kwon, H.-R., Grando, M., Cook, C., & Thompson, B. M. (2018) · Applied Clinical Informatics · doi:10.1055/s-0038-1676458 · Cited by 10
“13,40 However, from a glucose management perspective, there was not a signi fi cant difference on Δ G/min.”
Signal Quality Analysis of Single-Arm Electrocardiography
Wang, J.-J., Liu, S.-H., Tsai, C.-H., Manousakas, I., Zhu, X., & Lee, T. (2023) · Sensors · doi:10.3390/s23135818 · Cited by 9
Boumann, H., Hamann, A., Biella, M., Carstengerdes, N., & Sammito, S. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-35392-5_1 · Cited by 9
How to properly evaluate cardiac vagal tone in oncology studies: a state-of-the-art review
Martinez, P., Grinand, M., Cheggour, S., Taieb, J., & Gourjon, G. (2024) · Journal of the National Cancer Center · doi:10.1016/j.jncc.2024.02.002 · Cited by 9
Wang, J., Wang, Z., Zhang, Z., Li, P., Pan, H., Ren, Y., Hou, T., Wang, C., Kwong, C. F., Zhang, B., et al. (2024) · Micromachines · doi:10.3390/mi15040507 · Cited by 9
Paccione, C. E., Bruehl, S. P., Diep, L. M., Rosseland, L. A., Stubhaug, A., & Jacobsen, H. B. (2021) · PAIN Reports · doi:10.1097/pr9.0000000000000970 · Cited by 9
“Furthermore, reliance on pulse wave-derived HRV values, rather than ECG-derived HRV values, canpotentially lead to overestimation.(8,56)Not accounting for caffeine consumption, physical exercise intensity, specific cardioactive medication use, and nicotine intake immediately before HRV participant recording sessions m…”
MethodResultSleep Quality Evaluation Based on Single-Lead Wearable Cardiac Cycle Acquisition Device
Li, Y., Li, J., Yan, C., Dong, K., Kang, Z., Zhang, H., & Liu, C. (2022) · Sensors · doi:10.3390/s23010328 · Cited by 9
“Researchers Sensors 2023, 23, 328 13 of 20 have pointed out the good coincidence of HR & pulse rate (PR), HRV & pulse rate variability (PRV) [13]; thus, we can also obtain pulse intervals as a replacement of cardiac intervals.”
MethodChen, X. C., Liu, N., Huang, Y., Yun, F., Wang, J., & Jin, L. (2014) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9641-z · Cited by 9
“First, although fluctuations in pulse period and heart beat period are not exactly the same due to the variability of pulse transit time (PTT) [16], a few studies [17, 18] have verified that the variability of the PPG period parameter has a high correlation with HRV.”
BackgroundMultifunctional Photoplethysmography Sensor Design for Respiratory and Cardiovascular Diagnosis
Uguz, D. U., Venema, B., Leonhardt, S. K., & Teichmann, D. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9038-7_167 · Cited by 9
Liu, A., Sun, C., Liu, C.-C., Liu, W., Wu, H., & Huang, R.-M. (2019) · Tzu Chi Medical Journal · doi:10.4103/tcmj.tcmj_68_18 · Cited by 9
“Recently, a comprehensive review article claimed that the results of HRV analysis using PPI and RRI may differ in a short-term recording [4].”
BackgroundMethodSimulation and in vivo investigation of light-emitting diode, near infrared Gaussian beam profiles
Mirbagheri, M., Hakimi, N., Ebrahimzadeh, E., & Setarehdan, S. K. (2019) · Journal of Near Infrared Spectroscopy · doi:10.1177/0967033519884209 · Cited by 9
“It has been shown that there is a direct relation between this number and the Bland Altman ratio (BAR) value calculated between the HRV extracted from NIR spectroscopy and the reference HRV signal.(68) So, the number of the IBIs outside of the permissible range in the correction process can be considered as a metric t…”
MethodAlaerts, K., Taillieu, A., Prinsen, J., & Daniëls, N. (2021) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2021.105397 · Cited by 9
Ministro, G., Castaño, J. B., Barboza, C. D. A., Moura, E. G., Ferreira‐Melo, S. E., Mostarda, C. T., Fattori, A., Moreno, H., & Rodrigues, B. (2021) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2021.103830 · Cited by 9
Examining weekly heart rate variability changes: a comparison between monitoring methods
Ruiz‐Alias, S. A., Marcos‐Blanco, A., Clavero‐Jimeno, A., & García‐Pinillos, F. (2022) · Sports Engineering · doi:10.1007/s12283-022-00371-8 · Cited by 12
Workload management through glanceable feedback: The role of heart rate variability
Muñoz, J. E., Pereira, F., & Karapanos, E. (2016) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2016.7749477 · Cited by 8
Real-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Vila, G., Godin, C., Charbonnier, S., & Campagne, A. (2021) · Sensors · doi:10.3390/s21165357 · Cited by 8
“However, HRV parameters have also shown substantial deviations between PPG and ECG under the influence of moderate mental effort or wrist activity [14].”
MethodCamera-Based Heart Rate Variability for Estimating the Maturity of Neonatal Autonomic Nervous System
Liao, C., Zeng, Y., Tan, C., Yu, D., Song, X., Pan, L., He, C., Wang, Y., Yang, J., Lu, H., et al. (2024) · IEEE Internet of Things Journal · doi:10.1109/jiot.2024.3439524 · Cited by 8
“Besides, some studies found that short-term variability is also more susceptible to the disagreement between HRV measured by ECG and PPG, due to the fact that PPG estimates cardiac status through peripheral circulation [60].”
BackgroundRogers, D. W., Himariotis, A. T., Sherriff, T. J., Proulx, Q. J., Duong, M. T., Noel, S. E., & Cornell, D. J. (2025) · Sports · doi:10.3390/sports13020029 · Cited by 9
Design of Emotion-Driven Game Interaction Using Biosignals
Frachi, Y., Takahashi, T., Wang, F., & Barthet, M. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-05637-6_10 · Cited by 9
Jia, Z., Bekö, G., Zhang, Z., Zhong, L., & Ai, Z. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111862 · Cited by 8
A multispectral testbed for cardiovascular sensing using imaging photoplethysmography
Blackford, E. B., & Estepp, J. R. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253447 · Cited by 8
Gatouillat, A., Massot, B., Badr, Y., Sejdić, E., & Géhin, C. (2018) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0006729101090118 · Cited by 8
“Although widely used, the accuracy of other popular methods such as plethysmography is still questioned by the community (Schäfer and Vagedes, 2013) and suffer from heavy movement artifact.”
Initialization of Pulse Transit Time-Based Blood Pressure Monitors
Mukkamala, R., & Hahn, J. (2019) · Springer eBooks · doi:10.1007/978-3-030-24701-0_10 · Cited by 8
The effect of using activity workstations on heart rate variability during complex cognitive tasks
Pilcher, J. J., Morris, D. M., Limyansky, S. E., & Bryant, S. A. (2020) · Journal of American College Health · doi:10.1080/07448481.2020.1782919 · Cited by 9
“Although this method is commonly seen in the literature, it is an indirect measure linked to the sympathovagal balance.(69) LF HRV has been the center of several debates about the use of HRV, albeit it is often the best method available for the noninvasive measure of cardio sympathetic reactivity and autonomic balance.”
MethodA New Sleep Staging System for Type III Sleep Studies Equipped With a Tracheal Sound Sensor
Vanbuis, J., Feuilloy, M., Baffet, G., Meslier, N., Gagnadoux, F., & Girault, J. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3120927 · Cited by 8
Pulse rate variability: An alternative to heart rate variability in adults with spinal cord injury
Schoffl, J., Pozzato, I., Rodrigues, D., Arora, M., & Craig, A. R. (2023) · Psychophysiology · doi:10.1111/psyp.14356 · Cited by 8
Validity of the polar verity sense during swimming at different locations and intensities
López‐Belmonte, Ó., Febles‐Castro, A., Gay, A., Cuenca‐Fernández, F., Arellano, R., & Ruiz-Navarro, J. J. (2023) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14494 · Cited by 8
“6 The different results are likely related to environmental influences rather than device malfunction, 7,8 as several issues could arise due to the aquatic environment.”
BackgroundEvaluation of agreement between temporal series obtained from electrocardiogram and pulse wave.
Leikan, G. M., Rossi, E., Sanz, M., Delisle-Rodríguez, D., Mantaras, M. C., Nicolet, J., Zapata, D., Lapyckyj, I., Siri, L. N., & Perrone, M. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/705/1/012038 · Cited by 8
Garcia-Gonzalez, M. A., Fernández-Chimeno, M., Guede-Fernández, F., Ferrer-Mileo, V., Argelagos-Palau, A., Álvarez-Gómez, L., Parrado, E., Moreno, J., Capdevila, L., & Ramos-Castro, J. J. (2015) · Physiological Measurement · doi:10.1088/0967-3334/37/1/128 · Cited by 8
Use of photoplethysmography to predict mortality in intensive care units
Kock, K. D. S., & Marques, J. L. B. (2018) · Vascular Health and Risk Management · doi:10.2147/vhrm.s172643 · Cited by 8
“36,37 In this study, this measure was taken excluding the ectopic beats and signal noises, for only 1 minute.”
van Es, V. A. A., Lathauwer, I. L. J. D., Lopata, R. G. P., Kemperman, A. D. A. M., Dongen, R. P. V., Brouwers, R. W. M., Funk, M., & Kemps, H. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae050 · Cited by 8
“20,21 The automatic beat correction algorithm within the Kubios HRV tool was utilized to correct beats.”
MethodA Multi-Layered Origami Tactile Sensory Ring for Wearable Biomechanical Monitoring
Karmakar, R. S., Lin, H.-F., Huang, J., Chao, J., Liao, Y., & Lu, Y. (2024) · Biosensors · doi:10.3390/bios15010008 · Cited by 8
Hardon, H. J., Kerkhof, Y. N. V., Bartelds, B., Kammeraad, J. A. E., & van Deutekom, A. W. (2025) · JMIR Formative Research · doi:10.2196/70835 · Cited by 9
Mejía‐Mejía, E., & Kyriacou, P. A. (2022) · Applied Sciences · doi:10.3390/app12147238 · Cited by 7
Rudstam, G., Elofsson, U. O. E., Söndergaard, H. P., & Beck, B. D. (2023) · European Journal of Trauma & Dissociation · doi:10.1016/j.ejtd.2023.100353 · Cited by 8
Chen, H., Tse, M. Y. M., Chung, J. W. Y., Yau, S. Y., & Wong, T. K. S. (2023) · BMC Geriatrics · doi:10.1186/s12877-023-04585-8 · Cited by 9
Higgins, T. R., Lloyd, T., Manalansan, K., McDonald, S., & Thomas, B. (2018) · Journal of Human Sport and Exercise · doi:10.14198/jhse.2018.133.05 · Cited by 7
“The results of this study further demonstrate PPG as a technological advancement which delivers accurate HR monitoring, which Schafer and Vagedes (2013) have previously highlighted as a valid form of measuring HR.”
MethodChou, Y., Zhu, P., Huang, X., Lin, J., Liu, J., & Gu, Y. (2018) · International Conference on Control, Automation and Information Sciences (ICCAIS) · doi:10.1109/iccais.2018.8570697 · Cited by 7
Compliance of self-measured HRV using smartphone applications in collegiate athletes
Holmes, C. J., Sherman, S. R., Hornikel, B., Cicone, Z. S., Wind, S. A., & Esco, M. R. (2020) · The Journal of High Technology Management Research · doi:10.1016/j.hitech.2020.100376 · Cited by 7
Herzfrequenzvariabilitätsanalyse in der betriebsärztlichen Praxis
Böckelmann, I., & Sammito, S. (2020) · Zentralblatt für Arbeitsmedizin Arbeitsschutz und Ergonomie · doi:10.1007/s40664-020-00401-x · Cited by 7
Bassiouni, M. M., Hegazy, I., Rizk, N. J., El-Dahshan, E.-S. A., & Salem, A.-B. M. (2021) · International Conference on Intelligent Computing and Information Systems (ICICIS) · doi:10.1109/icicis52592.2021.9694241 · Cited by 7
Combination of ECG and PPG Signals for Healthcare Applications: A Survey
Bassiouni, M. M., Hegazy, I., Rizk, N. J., El-Dahshan, S. A., & Salem, A.-B. M. (2021) · Advances in Modelling and Analysis B · doi:10.18280/ama_b.641-409 · Cited by 7
“It is considered to be the nearest alternative to the ECG signal as it holds essential cardiovascular information [5, 6].”
BackgroundValidation of a smart shirt for heart rate variability measurements at rest and during exercise
Schams, P., Feodoroff, B., Zacher, J., Eibl, A., & Froböse, I. (2022) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12746 · Cited by 8
“We excluded record segments from further statistical analysis with more than 10% of beat errors (Schäfer & Vagedes, 2013) as well as their paired record segment obtained by the other device.”
MethodPires, N. F., Coelho‐Júnior, H. J., Gambassi, B. B., de Faria, A. P., Ritter, A. M. V., Gasparetti, C. S., Pioli, M. R., Ruberti, O. M., Ferreira‐Melo, S. E., Moreno, H., et al. (2022) · BioMed Research International · doi:10.1155/2022/8202610 · Cited by 8
“Although the PI variability assessment may be considered less accurate than measuring heart rate variability by electrocardiogram, some studies have demonstrated the agreement between heart rate variability and PI variability [26, 27].”
Collard, D., Westerhof, B. E., Karemaker, J. M., Stok, W. J., Postema, P. G., Krediet, C. T. P., Vogt, L., & van den Born, B. H. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02768-4 · Cited by 9
Towards a physiology based difficulty control system for serious games
Köles, M., Szegletes, L., & Forstner, B. (2015) · IEEE International Conference on Cognitive Infocommunications · doi:10.1109/coginfocom.2015.7390612 · Cited by 7
“Data quality will be an issue, as it is with current photoplethysmography based technologies [26], but the potential of widespread application in everyday life make cardiac measures ideal candidates for our system.”
BackgroundRemote detection of photoplethysmographic signal and SVM based classification
Kalkhaire, S. D., & Puranik, V. G. (2016) · IEEE International Conference on Advances in Electronics, Communication and Computer Technology (ICAECCT) · doi:10.1109/icaecct.2016.7942568 · Cited by 7
Lekkala, R. G. R., & Kuntamalla, S. (2017) · IEEE Healthcare Innovations and Point of Care Technologies Conference (HI-POCT) · doi:10.1109/hic.2017.8227599 · Cited by 7
Parasnis, R., Pawar, A. B., & Manivannan, M. (2015) · International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS) · doi:10.1109/iciibms.2015.7439531 · Cited by 7
“As for MSE, none of the 105 studies that were reviewed in [14] includes any entropy measure computed over multiple temporal scales.”
BackgroundKuntamalla, S., & Lekkala, R. G. R. (2018) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2018.1513578 · Cited by 7
Detection of Daily Emotions by Wearable Biometric Sensors
Yuda, E., Tanabiki, T., Iwata, S., Abe, K., & Hayano, J. (2019) · IEEE Global Conference on Life Sciences and Technologies (LifeTech) · doi:10.1109/lifetech.2019.8883968 · Cited by 7
“Second, the shape of the peaks changes with stroke volume, blood pressure, pulse wave velocity and the pressure reflection from peripheral vasculatures, which are affected by body posture, respiration, and emotions [3].”
BackgroundVorreuther, A., Tagalidou, N., & Vukelić, M. (2025) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2025.1585469 · Cited by 10
Assessing pedestrian stress with biometric sensing and survey responses
Ma, S., Zhang, W., Noland, R. B., Andrews, C. J., Younes, H., & Hagen, L. A. V. (2025) · Transportation Research Part F Traffic Psychology and Behaviour · doi:10.1016/j.trf.2025.103347 · Cited by 7
Zhao, Y., Chen, P., Zhang, Y., Huo, S., Yu, D., Zeng, X., & Zhang, W. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1654796 · Cited by 6
Metadata
- Authors
- Schäfer, A., & Vagedes, J.
- Affiliations
- Academic Research in Complementary and Integrative Medicine (DE)
- University Children's Hospital Tübingen (DE)
- Corresponding author
- Vagedes, Jan
- ORCID
- Vagedes, Jan
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 166
- Issue
- 1
- Pages
- 15-29
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W188715143
- Cited by
- 661
- References
- 114
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 56 · 2023: 52 · 2022: 57 · 2021: 72 · 2020: 67 · 2019: 49 · 2018: 59 · 2017: 40 · 2016: 40 · 2015: 29 · 2014: 19 · 2013: 9
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- pulse rate variability, heart rate variability, photoplethysmography, pulse oximetry, RR interval, measurement accuracy, physical activity, psychological stress, sensor position, detection algorithm, ambulatory monitoring
- MeSH terms
- Electrocardiography, Heart Rate, Humans, Motor Activity, Pulse, Rest, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review