How accurate is pulse rate variability as an estimate of heart rate variability?
Abstract
Background The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV.Methods We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography).Results/conclusions Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A comparative review of photoplethysmography against ECG stated that photoplethysmography can be used during rest but not during stress (Schafer and Vagedes, 2013).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Schafer and Vagedes, 2013
In the citing paper
“However, it cannot yet be considered to be a surrogate during exercise or stress [17], [129].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
In the citing paper
“Nonetheless, reviews have concluded that PRV is a good surrogate of HRV for certain applications at rest.”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Flagged first, then by citations
2 of the 114 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Herzman, 1937, Observations on the finger volume pulse recorded photoelectrically, Am J Physiol, 119, 334
- Janssen, 1994, Methods in heart rate variability analysis: may the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm?, High Blood Pressure, 3, 23
- Khandoker, 2011, Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea, Med Eng Phys, 33, 204, 10.1016/j.medengphy.2010.09.020 · DOI
Cited by
Sorted by citations
Laborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336
“A comparative review of photoplethysmography against ECG stated that photoplethysmography can be used during rest but not during stress (Schafer and Vagedes, 2013).”
BackgroundShaffer, F., McCraty, R., & Zerr, C. L. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01040 · Cited by 1,866
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 589
“Regardless of how successful these systems has been in acquiring physiological parameters, e.g., HR/respiration rate (RR) and HRV, a number of key questions still remain regarding IPPG systems that utilize ambient light as the illumination source, such as the practical issue of how variations in ambient light intensit…”
InfluentialWearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Digital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity
Kourtis, L. C., Regele, O. B., Wright, J. M., & Jones, G. B. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0084-2 · Cited by 476
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 514
“However, it was reported that PRV could be differ from HRV under dynamic conditions, such as exercise or mental stress conditions (Schäfer and Vagedes, 2013; Mejía-Mejía et al., 2020).”
BackgroundAssociation between heart rate variability and fluctuations in resting-state functional connectivity
Chang, C., Metzger, C. D., Glover, G. H., Duyn, J. H., Heinze, H., & Walter, M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.038 · Cited by 368
A Review of Psychophysiological Measures to Assess Cognitive States in Real-World Driving
Lohani, M., Payne, B. R., & Strayer, D. L. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00057 · Cited by 347
“Such methodological differences between PPG and ECG can explain why PPG and ECG findings are comparable during rest, but are not comparable during stress, for example (Schäfer and Vagedes, 2013).”
Plews, D. J., Scott, B., Altini, M., Wood, M., Kilding, A. E., & Laursen, P. B. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0668 · Cited by 323
“When we contrast other studies that have compared HRV values measured through PPG against ECG it is currently difficult, as differences between experimental settings and/or methods of analysis are apparent.(19) Furthermore, many of these studies have been carried out using a variety of “clip-on” devices (e.”
Resultde Zambotti, M., Goldstein, C. A., Cook, J. D., Menghini, L., Altini, M., Cheng, P., & Robillard, R. (2023) · SLEEP · doi:10.1093/sleep/zsad325 · Cited by 276
A Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research
Shaffer, F., Meehan, Z. M., & Zerr, C. L. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594880 · Cited by 264
“The ECG method is more accurate than PPG during paced breathing (Jan et al., 2019) and when increased sympathetic tone results in vasoconstriction in monitored fingers (Giardino et al., 2002; Schafer and Vagedes, 2013).”
MethodWearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244
Physiological and Behavioral Responses Reveal 9-Month-Old Infants’ Sensitivity to Pleasant Touch
Fairhurst, M. T., Löken, L. S., & Großmann, T. (2014) · Psychological Science · doi:10.1177/0956797614527114 · Cited by 250
“In the absence of excessive movement, the signal from pulse oximetry is comparable to that from the ECG (Schäfer & Vagedes, 2013).”
MethodQuigley, K. S., Gianaros, P. J., Norman, G. J., Jennings, J. R., Berntson, G. G., & de Geus, E. J. C. (2024) · Psychophysiology · doi:10.1111/psyp.14604 · Cited by 281
Kim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 260
“Pulse rate variability (PRV) measurement is a commonly used parameter in addition to pulse rate measurement [51,52].”
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 233
Dobbs, W. C., Fedewa, M. V., MacDonald, H. V., Holmes, C. J., Cicone, Z. S., Plews, D. J., & Esco, M. R. (2019) · Sports Medicine · doi:10.1007/s40279-019-01061-5 · Cited by 194
Kinnunen, H., Rantanen, A., Kenttä, T., & Koskimäki, H. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab840a · Cited by 184
“The main challenge is sensitivity to motion, and studies have illustrated more noisy estimates of HRV with PPG than those measured with ECG, particularly in high-frequency parameters (Schäfer and Vagedes 2013).”
BackgroundDüking, P., Andreas Hotho, A., Holmberg, H., Fuss, F. K., & Sperlich, B. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00071 · Cited by 184
“However, it should be noted that such devices measure variations in pulse rate rather than HRV directly (Schäfer and Vagedes, 2013).”
BackgroundUBFC-Phys: A Multimodal Database For Psychophysiological Studies of Social Stress
Sabour, R. M., Benezeth, Y., Oliveira, P. D., Chappé, J., & Yang, F. (2021) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2021.3056960 · Cited by 192
“Several studies focused on the analogy between PRV and HRV, leading to the result that both are linked to the ANS activity, and that the same features can be extracted from the two signals [5].”
BackgroundMejía‐Mejía, E., Budidha, K., Abay, T. Y., May, J. M., & Kyriacou, P. A. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00779 · Cited by 178
“Nonetheless, although PRV has been treated as a valid surrogate of HRV, their relationship is not entirely clear, and PRV has been found to significantly differ from HRV under certain circumstances (Schäfer and Vagedes, 2013).”
BackgroundTeixeira, E., Fonseca, H., Diniz‐Sousa, F., Veras, L., Boppre, G., de Oliveira, J. J. F., Pinto, D., Alves, A. J., Barbosa, A., Mendes, R., et al. (2021) · Geriatrics · doi:10.3390/geriatrics6020038 · Cited by 179
“Most evidence supports PRV as a valid surrogate of HRV in healthy and younger adults at rest [67].”
BackgroundCan PPG be used for HRV analysis?
Pinheiro, N. C., Couceiro, R., Henriques, J. M. O., Muehlsteff, J., Quintal, I., Gonçalves, L. M. M., & Carvalho, P. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591347 · Cited by 172
“A major challenge for using PPG in HRV analysis is its sensitivity to motion artifacts [3, 5].”
BackgroundMethodInfluentialLi, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160
Reitz, S. C., Kluetsch, R. C., Niedtfeld, I., Knorz, T., Lis, S., Paret, C., Kirsch, P., Meyer‐Lindenberg, A., Treede, R., Baumgärtner, U., et al. (2015) · The British Journal of Psychiatry · doi:10.1192/bjp.bp.114.153379 · Cited by 160
Mejía‐Mejía, E., May, J. M., Torres, R., & Kyriacou, P. A. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab998c · Cited by 160
“…points (Constant et al 1999, Giardino et al 2002, Rauh et al 2003, Lu and Yang 2009, Charlot et al 2009, Khandoker et al 2011, Wong et al 2012, Schäfer and Vagedes 2013, Dehkordi et al 2013aa, Pellegrino et al 2014, Parasnis et al 2015, Chen et al 2015, Peng et al 2015, Shin 2016, Pinheiro…”
BackgroundResultInfluentialStressing the accuracy: Wrist‐worn wearable sensor validation over different conditions
Menghini, L., Gianfranchi, E., Cellini, N., Patron, E., Tagliabue, M., & Sarlo, M. (2019) · Psychophysiology · doi:10.1111/psyp.13441 · Cited by 157
Heart rate variability and self-control—A meta-analysis
Zahn, D., Adams, J., Krohn, J., Wenzel, M., Mann, C. G., Gomille, L. K., Jacobi-Scherbening, V., & Kubiak, T. (2015) · Biological Psychology · doi:10.1016/j.biopsycho.2015.12.007 · Cited by 177
Mulcahy, J. S., Larsson, D. E. O., Garfinkel, S. N., & Critchley, H. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116072 · Cited by 163
Extraction of Heart Rate Variability from Smartphone Photoplethysmograms
Peng, R., Zhou, X.-L., Lin, W.-H., & Zhang, Y. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/516826 · Cited by 157
“Agreements were ranked as good (BAR < 10%), moderate (10% ≤ BAR < 20%), or insufficient (BAR ≥ 20%) [28].”
BackgroundHidden Signals—The History and Methods of Heart Rate Variability
Ernst, G. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00265 · Cited by 174
“Smart-watches: a potential challenger to the implantable loop recorder? Europace (2016) 18(6):791–3.”
BackgroundMethodInfluentialQuandt, B. M., Scherer, L. J., Boesel, L. F., Wolf, M., Bona, G. L., & Rossi, R. M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400463 · Cited by 148
Evaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148
Mansi, S. A., Barone, G. B., Forzano, C., Pigliautile, I., Ferrara, M., Pisello, A. L., & Arnesano, M. (2021) · Measurement · doi:10.1016/j.measurement.2021.109872 · Cited by 153
Chow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140
Touch increases autonomic coupling between romantic partners
Chatel-Goldman, J., Congedo, M., Jutten, C., & Schwartz, J.-L. (2014) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2014.00095 · Cited by 135
“It has been demonstrated that PRV is an accurate estimator of HRV when applied to healthy subjects at rest (Schäfer and Vagedes, 2013), a requirement that is satisfied in our study.”
BackgroundMethodDirect and indirect effects of age on interoceptive accuracy and awareness across the adult lifespan
Murphy, J., Geary, H., Millgate, E., Catmur, C., & Bird, G. (2018) · Psychonomic Bulletin & Review · doi:10.3758/s13423-017-1339-z · Cited by 137
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
A Survey on Wearable Sensors for Mental Health Monitoring
Gomes, N., Pato, M. P. M., Lourenço, A., & Datia, N. (2023) · Sensors · doi:10.3390/s23031330 · Cited by 161
Wang, R., Mu, L., Bao, Y., Lin, H., Ji, T., Shi, Y., Zhu, J., & Wu, W. (2020) · Advanced Materials · doi:10.1002/adma.202002878 · Cited by 125
Autonomic dysfunction in acute ischemic stroke: An underexplored therapeutic area?
Raedt, S. D., Vos, A. D., & Keyser, J. D. (2014) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2014.12.007 · Cited by 125
“Alternatively, interbeat intervals (ibi) might be calculated from non-invasive blood pressure monitoring using plethysmography (eg NEXFIN HD®, WatchPAT®, POLAR®, Finometer®, CNAPTM®, Finapres®), which is called pulse rate variability [15–17].”
MethodGuo, C. C., Sturm, V. E., Zhou, J. H., Gennatas, E. D., Trujillo, A. J., Hua, A. Y., Crawford, R. K., Stables, L. A., Kramer, J. H., Rankin, K. P., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509184113 · Cited by 130
“Although few studies have assessed clinical and older populations, pulse rate variability offers an accurate estimate of HRV at rest in healthy adults (73).”
BackgroundMethodGraphene coated textile based highly flexible and washable sports bra for human health monitoring
Shathi, M. A., Chen, M., Khoso, N. A., Rahman, M. T., & Bhattacharjee, B. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.108792 · Cited by 126
A deep transfer learning approach for wearable sleep stage classification with photoplethysmography
Radha, M., Fonseca, P. M., Moreau, A., Ross, M., Cerny, A., Anderer, P., Long, X., & Aarts, R. M. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00510-8 · Cited by 136
“As mentioned before, these can be caused by, for example, the known discrepancy in hemodynamic or cardiovascular physiology between HRV data measured from ECG and PPG signals and for assessing autonomic responses 39,40 , and a higher sensitivity of wrist-worn PPG to motion artefacts than ECG 41 .”
BackgroundCardiovascular assessment by imaging photoplethysmography – a review
Zaunseder, S., Trumpp, A., Wedekind, D., & Malberg, H. (2018) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0119 · Cited by 121
Heart rate variability in bipolar disorder: A systematic review and meta-analysis
Faurholt‐Jepsen, M., Kessing, L. V., & Munkholm, K. (2016) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2016.12.007 · Cited by 120
Hettiarachchi, I. T., Hanoun, S., Nahavandi, D., & Nahavandi, S. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217288 · Cited by 132
A Practical Guide to Resonance Frequency Assessment for Heart Rate Variability Biofeedback
Shaffer, F., & Meehan, Z. M. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.570400 · Cited by 133
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 134
Estepp, J. R., Blackford, E. B., & Meier, C. M. (2014) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2014.6974121 · Cited by 118
“The difference between the ECG/IBI- and PPG/IPI-derived cardiac cycle rates served as a best-case baseline comparison to calculating heart rate from ECG using rates based on individual cycle identification to create IXI time series, as cardiac cycle rates derived from ECG and PPG should not a priori assumed to be equa…”
BackgroundMethodUmair, M., Chalabianloo, N., Sas, C., & Ersoy, C. (2021) · IEEE Access · doi:10.1109/access.2021.3052131 · Cited by 124
“Investigation of photoplethysmography (PPG) accuracy as an estimate of HRV and the possibility of employing it as a surrogate of electrocardiography (ECG) have been the topics of many experimental and survey studies [19], [21], [55], [56].”
BackgroundWearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113
A literature review of heart rate variability in depressive and bipolar disorders
Bassett, D. L. (2015) · Australian & New Zealand Journal of Psychiatry · doi:10.1177/0004867415622689 · Cited by 113
“HRV is also highly sensitive to respiration, including respiratory rate, respiratory depth and respiratory sinus arrhythmia (RSA) (Heathers, 2014; Perakakis et al., 2009; Quintana and Heathers, 2014; Schafer and Vagedes, 2013; Shaffer et al., 2014).”
BackgroundAn Open Framework for Remote-PPG Methods and Their Assessment
Boccignone, G., Conte, D., Cuculo, V., D’Amelio, A., Grossi, G., & Lanzarotti, R. (2020) · IEEE Access · doi:10.1109/access.2020.3040936 · Cited by 109
“This fact is witnessed by a number of publications reporting universally good agreement between PRV and HRV, even if this concordance may be susceptible of many variables such as experimental conditions and postures (see [48] and the citations thereof).”
BackgroundMethodZhang, Y., Liu, B., & Zhang, Z. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.05.006 · Cited by 109
Cho, Y., Julier, S., & Bianchi‐Berthouze, N. (2018) · JMIR Mental Health · doi:10.2196/10140 · Cited by 109
“In the case of PPG, the term Pulse Rate Variability (PRV) or PPG HRV are often used to clarify the different type (even if related) of event measured [26,29–31] with respect to ECG.”
MethodA Review of Deep Learning-Based Contactless Heart Rate Measurement Methods
Ni, A., Azarang, A., & Kehtarnavaz, N. (2021) · Sensors · doi:10.3390/s21113719 · Cited by 109
“Contact ECG and PPG [19] 2012 Accuracy of pulse rate variability (PRV) as an estimate of HRV”
BackgroundMethodRemote Healthcare for Elderly People Using Wearables: A Review
Olmedo-Aguirre, J. O., Reyes-Campos, J., Alor‐Hernández, G., Machorro-Cano, I., Rodríguez-Mazahua, L., & Sánchez-Cervantes, J. L. (2022) · Biosensors · doi:10.3390/bios12020073 · Cited by 121
Donker, M. H., van Gog, T., & Mainhard, T. (2018) · Frontline Learning Research · doi:10.14786/flr.v6i3.372 · Cited by 105
“Seven electrodes were placed on the teacher’s chest to minimize the influence of movement (Porges & Byrne, 1992) and to get a more reliable estimate of heart rate than with wristbands based on pulse plethysmography (PPG; Rohrbaugh, 2016; Schäfer & Vagedes, 2013).”
MethodEvaluation of the beat-to-beat detection accuracy of PulseOn wearable optical heart rate monitor
Parák, J., Tarniceriu, A., Renevey, P., Bertschi, M., Delgado-Gonzalo, R., & Korhonen, I. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320273 · Cited by 99
“However, it has been suggested that pulse rate variability (PRV) from PPG is sufficiently accurate only for healthy (and mostly younger) subjects at rest, HRV estimated from PRV tends to be overestimated against ECG based values, and motion artifacts lead to inaccurate PPGbased beat detection [15].”
BackgroundSammito, S., Thielmann, B., Klußmann, A., Deußen, A., Braumann, K.-M., & Böckelmann, I. (2024) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-024-00414-9 · Cited by 116
“A systematic review [24] showed that only in young, healthy subjects under resting conditions are there acceptable correspondences between NN intervals and pulse NN intervals, but HRV parameters based on the pulse NN intervals are sometimes significantly increased (e.g. in HF).”
BackgroundYe, Y., Cheng, Y., He, W., Hou, M., & Zhang, Z. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2597265 · Cited by 94
“Since rhythms of PPG signals correspond to heartbeats, estimated HR from PPG signals can be achieved by detecting instantaneous fundamental frequency of PPG signals [6], [7].”
MethodAn Ultra Low Power Personalizable Wrist Worn ECG Monitor Integrated With IoT Infrastructure
Beach, C., Krachunov, S., Pope, J., Fafoutis, X., Piechocki, R. J., Craddock, I., & Casson, A. J. (2018) · IEEE Access · doi:10.1109/access.2018.2864675 · Cited by 91
“For PPG signals, we note that variability measures are typically termed Pulse Rate Variability (PRV) [60] to account for the minor differences between HRV and PRV as the pulse transit time down the arm varies with posture and blood pressure.”
BackgroundMethodInfluentialPapini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90
Hohenschurz‐Schmidt, D., Calcagnini, G., Dipasquale, O., Jackson, J. B., Medina, S., O’Daly, O., O’Muircheartaigh, J., Rubio, A. D. L., Williams, S., McMahon, S. B., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00147 · Cited by 91
“Sufficient accuracy under stationary conditions has also been confirmed by a review on the topic (Schäfer and Vagedes, 2013).”
BackgroundMethodSarkar, P., & Etemad, A. (2021) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v35i1.16126 · Cited by 88
Zhang, X., Kou, W., Chang, E., Gao, H., Fan, Y., & Xu, Y. L. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.10.010 · Cited by 91
Sensors Capabilities, Performance, and Use of Consumer Sleep Technology
de Zambotti, M., Cellini, N., Menghini, L., Sarlo, M., & Baker, F. C. (2020) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2019.11.003 · Cited by 95
Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79
Михайлович, У. А. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aabd09 · Cited by 78
“…from electrocardiogram or assessed by pulse rate (number of pulse waves transmitted from heart to periphery per unit of time, usually highly correlated with heart rate (Schäfer and Vagedes 2013))which can be computed from indirect measurements such as photoplethysmogram (PPG, (Allen 2007).”
BackgroundMethodInfluentialWeiler, D. T., Villajuan, S. O., Edkins, L., Cleary, S., & Saleem, J. J. (2017) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1541931213601804 · Cited by 87
“In fact, the usefulness of heart rate variability as a clinical diagnostic and research tool has previously been verified (Schafer & Vagedes, 2013).”
MethodInfluentialMayo, O., Lavidor, M., & Gordon, I. (2021) · Physiology & Behavior · doi:10.1016/j.physbeh.2021.113391 · Cited by 73
Shilton, A. L., Laycock, R., & Crewther, S. G. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00567 · Cited by 76
Ding, Z., Li, W., Wang, W., Zhao, Z., Zhu, Y., Hou, B., Zhu, L., Chen, M., & Che, L. (2024) · Advanced Science · doi:10.1002/advs.202309407 · Cited by 76
A scoping review of heart rate variability in sport and exercise psychology
Mosley, E., & Laborde, S. (2022) · International Review of Sport and Exercise Psychology · doi:10.1080/1750984x.2022.2092884 · Cited by 85
Vescio, B., Salsone, M., Gambardella, A., & Quattrone, A. (2018) · Sensors · doi:10.3390/s18030844 · Cited by 73
Bruehl, S. P., Olsen, R. B., Tronstad, C., Sevre, K., Burns, J. W., Schirmer, H., Nielsen, C. S., Stubhaug, A., & Rosseland, L. A. (2017) · Pain · doi:10.1097/j.pain.0000000000001070 · Cited by 73
“intervals reflected in both measures, R-R intervals can be estimated using pulse wave data obtained by plethysmography in the course of acquiring continuous noninvasive beat-to-beat BPs.(50) A systematic review showed that most investigations demonstrated good agreement between HRV estimates based on”
BackgroundMethodInfluentialEffects of slow breathing rate on blood pressure and heart rate variabilities
Chang, Q., Liu, R., & Shen, Z. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.08.121 · Cited by 66
Scardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., & Bellavia, D. (2020) · Sensors · doi:10.3390/s20185052 · Cited by 72
Valenza, G., Passamonti, L., Duggento, A., Toschi, N., & Barbieri, R. (2020) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0878 · Cited by 77
Shilaih, M., Clerck, V. D., Falco, L., Kübler, F., & Leeners, B. (2017) · Scientific Reports · doi:10.1038/s41598-017-01433-9 · Cited by 69
Analysis of a Pulse Rate Variability Measurement Using a Smartphone Camera
Bánhalmi, A., Borbás, J., Fidrich, M., Bilicki, V., Gingl, Z., & Rudas, L. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/4038034 · Cited by 69
“PRV and HRV have good correlations, and it was con fi rmed by several previous publications [9 – 11].”
BackgroundResultSelf-Compassion and Psycho-Physiological Recovery From Recalled Sport Failure
Ceccarelli, L. A., Giuliano, R. J., Glazebrook, C. M., & Strachan, S. M. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.01564 · Cited by 85
“It should also be noted that here we used photoplethysmography as a proxy for electrocardiogram activity, and although these two measures may diverge under conditions of acute stress (Schäfer and Vagedes, 2013), photoplethysmography has been demonstrated to reliably assess acute stress reactivity (Charlton et al.”
MethodAccuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients
Antink, C. H., Mai, Y., Peltokangas, M., Leonhardt, S. K., Oksala, N., & Vehkaoja, A. T. (2021) · Scientific Reports · doi:10.1038/s41598-021-87489-0 · Cited by 66
Iozzia, L., Cerina, L., & Mainardi, L. T. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/11/1934 · Cited by 66
“[23] on the accuracy of PRV as an estimate of HRV.”
BackgroundResultMember, I., Pernice, R., Javorka, M., Krohová, J., Czippelová, B., Turianiková, Z., Busacca, A., & Faes, L. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-01957-4 · Cited by 66
Quantitative detection of sleep apnea with wearable watch device
Hayano, J., Yamamoto, H., Nonaka, I., Komazawa, M., Itao, K., Ueda, N., 田中, 春., & Yuda, E. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237279 · Cited by 67
Jan, H.-Y., Chen, M.-F., Fu, T., Lin, W., Tsai, C.-L., & Lin, K. (2019) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-019-00468-9 · Cited by 69
“We found that the PPGderived PR from either limb was an acceptable surrogate of ECG-derived HR, as reported in the literature [10, 11, 24, 33].”
BackgroundResultInfluentialReduction of Periodic Motion Artifacts in Photoplethysmography
Wijshoff, R. W. C. G. R., Mischi, M., & Aarts, R. M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2553060 · Cited by 66
“This may result from residual motion artifacts, or from physiological fluctuations in IBIs during walking caused by variations in pre-ejection time and pulse transit time [22].”
Shin, H. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9798-0 · Cited by 63
Lyu, Y., Luo, X., Zhou, J., Yu, C., Miao, C., Wang, T., Shi, Y., & Kameyama, K.-I. (2015) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702399 · Cited by 60
“The ECG was measured using a SMOTE PSG device (Compumedics Ltd., Australia) at a sampling rate of 200Hz [24].”
BackgroundMethodKoenig, N., Seeck, A., Eckstein, J., Mainka, A., Huebner, T. A., Voss, A., & Weber, S. (2016) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0212 · Cited by 60
“In the studies reviewed by Scha¨fer and Vagedes, 10 correlation values of R ‡ 0.9 were achieved for all HRV parameters when comparing HRV analysis by plethysmography with ECG recordings.”
InfluentialThe accuracy of heartbeat detection using photoplethysmography technology in cardiac patients
Blok, S., Piek, M. A., Tulevski, I. I., Somsen, G. A., & Winter, M. M. (2021) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2021.06.009 · Cited by 59
Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity
Jarchi, D., & Casson, A. J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668763 · Cited by 58
“have shown that despite these minor differences PRV can be a useful measure of instantaneous heart rate [19]–[21], but it has not been possible to extract measures of instantaneous heart”
BackgroundPietilä, J., Mehrang, S., Tolonen, J., Helander, E. E., Jimison, H. B., Misha Pavel, C., & Korhonen, I. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_37 · Cited by 59
Estimation of Mental Distress from Photoplethysmography
Zangróniz, R., Martínez‐Rodrigo, A., López, M. T., Pastor, J. M., & Fernández‐Caballero, A. (2018) · Applied Sciences · doi:10.3390/app8010069 · Cited by 59
“However, a high correlation between both metrics has been reported for subjects at rest [20].”
BackgroundTasmurzayev, N., Amangeldy, B., Иманбек, Б., Baigarayeva, Z., Imankulov, T., Dikhanbayeva, G., Amangeldi, I., & Sharipova, S. (2025) · Sensors · doi:10.3390/s25175272 · Cited by 62
“…strategies address this by first applying timestamp normalization to a common reference clock, often using the ECG R-wave peaks as temporal anchors for resampling lower-frequency signals such as PPG or respiration to physiologically relevant intervals (e.g., RR-interval alignment) [41].”
Blackford, E. B., & Estepp, J. R. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2083940 · Cited by 58
Weinschenk, S. W., Beise, R. D., & Lorenz, J. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3401-3 · Cited by 56
“In accordance with other studies [for review, see (Schafer and Vagedes 2013)], HRV parameters reflecting long-term variability, such as mean-HR, SD2, and SDNN, agreed better than parameters reflecting the highly dynamic short-term changes of the heart rate (e.g., SD1, Power HF band, and RMSSD).”
BackgroundMethodResultInfluential
Metadata
- Authors
- Schäfer, A., & Vagedes, J.
- Affiliations
- Academic Research in Complementary and Integrative Medicine (DE)
- University Children's Hospital Tübingen (DE)
- Corresponding author
- Vagedes, Jan
- ORCID
- Vagedes, Jan
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 166
- Issue
- 1
- Pages
- 15-29
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W188715143
- Cited by
- 661
- References
- 114
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 56 · 2023: 52 · 2022: 57 · 2021: 72 · 2020: 67 · 2019: 49 · 2018: 59 · 2017: 40 · 2016: 40 · 2015: 29 · 2014: 19 · 2013: 9
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- pulse rate variability, heart rate variability, photoplethysmography, pulse oximetry, RR interval, measurement accuracy, physical activity, psychological stress, sensor position, detection algorithm, ambulatory monitoring
- MeSH terms
- Electrocardiography, Heart Rate, Humans, Motor Activity, Pulse, Rest, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review