How accurate is pulse rate variability as an estimate of heart rate variability?
Abstract
Background The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV.Methods We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography).Results/conclusions Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A comparative review of photoplethysmography against ECG stated that photoplethysmography can be used during rest but not during stress (Schafer and Vagedes, 2013).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Schafer and Vagedes, 2013
In the citing paper
“However, it cannot yet be considered to be a surrogate during exercise or stress [17], [129].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
In the citing paper
“Nonetheless, reviews have concluded that PRV is a good surrogate of HRV for certain applications at rest.”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Flagged first, then by citations
2 of the 114 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Herzman, 1937, Observations on the finger volume pulse recorded photoelectrically, Am J Physiol, 119, 334
- Janssen, 1994, Methods in heart rate variability analysis: may the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm?, High Blood Pressure, 3, 23
- Khandoker, 2011, Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea, Med Eng Phys, 33, 204, 10.1016/j.medengphy.2010.09.020 · DOI
Cited by
Sorted by citations
Items 101–200 of 660
Transfer learning from ECG to PPG for improved sleep staging from wrist-worn wearables
Li, Q., Li, Q., Cakmak, A. S., Poian, G. D., Bliwise, D. L., Vaccarino, V., Shah, A. J., & Clifford, G. D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/abf1b0 · Cited by 55
“Schäfer and Vagedes (2013) stated that pulse rate variability (PRV) is proved to be sufficiently accurate as an estimate of HRV for healthy subjects at rest in their review paper.”
BackgroundLudwig, M., Hoffmann, K., Endler, S., Asteroth, A., & Wiemeyer, J. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00778 · Cited by 55
“Therefore, inconsistent findings regarding the reliability can be found depending on location of sensor, experimental condition and performed exercise (0.11–0.99; Schäfer and Vagedes, 2013).”
BackgroundInfluentialBlanchard, M., Gervès‐Pinquié, C., Feuilloy, M., Vaillant, M. L., Trzépizur, W., Meslier, N., Paris, A., Pigeanne, T., Racineux, J.-L., Balusson, F., et al. (2021) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202009-1202oc · Cited by 53
Functional Overreaching in Endurance Athletes: A Necessity or Cause for Concern?
Bellinger, P. (2020) · Sports Medicine · doi:10.1007/s40279-020-01269-w · Cited by 64
“However, not all photoplethysmography variables returned to baseline values following 2 weeks of recovery, and the error of measurement can be dependent on the photosensitivity of the skin [53].”
BackgroundMorelli, D., Bartoloni, L., Colombo, M., Plans, D., & Clifton, D. A. (2017) · Healthcare Technology Letters · doi:10.1049/htl.2017.0039 · Cited by 51
“That is, one first defines {NN50} as being that subset of {NN intervals} that exceed a duration of 50 ms, and where pNN50 is |NN50|/|NNintervals|, where | · | is set cardinality [4, 11, 13].”
BackgroundDavila, M. I., Lewis, G. F., & Porges, S. W. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00300 · Cited by 54
“A less invasive surrogate of HRV can be derived from the arterial pulse obtained using the photoplethysmogram (PPG), which provides sufficient accuracy to track individual HRV reactions to physical and mental challenges (11).”
MethodMethodological Shortcomings of Wrist-Worn Heart Rate Monitors Validations
Sartor, F., Papini, G. B., Cox, L. G. E., & Cleland, J. G. F. (2018) · Journal of Medical Internet Research · doi:10.2196/10108 · Cited by 51
Heart Rate Variability Applications in Strength and Conditioning: A Narrative Review
Addleman, J. S., Lackey, N. S., DeBlauw, J. A., & HAJDUCZOK, A. G. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9020093 · Cited by 60
“, many commercially available wearable devices measure HRV through photo-plethysmography (PPG) [22] and heart rate sensors.”
BackgroundInfluentialEsco, M. R., Flatt, A. A., & Nakamura, F. Y. (2016) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001519 · Cited by 50
“Although a number of studies are available to show pulse plethysmography to accurately reflect beat-to-beat cardiac cycles compared with ECG (27), limited evidence exists examining the accuracy of the ithlete pulse finger sensor.”
BackgroundMethodInfluentialImplicit Analysis of Perceptual Multimedia Experience Based on Physiological Response: A Review
Moon, S.-E., & Lee, J. (2016) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2016.2614880 · Cited by 52
“Heart rate, which is measured by plethysmography or electrocardiogram (ECG), is also a cue of the state of the sympathetic nervous system [86].”
Background\Accurate measurement of the pulse wave delay with imaging photoplethysmography
Kamshilin, A. A., Sidorov, I. S., Babayan, L., Volynsky, M. A., Giniatullin, R. A., & Mamontov, O. V. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.005138 · Cited by 51
SVR ensemble-based continuous blood pressure prediction using multi-channel photoplethysmogram
Fong, M. W. K., Ng, E. Y. K., Jian, K. E. Z., & Hong, T. J. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103392 · Cited by 50
Validity of the Wrist-Worn Polar Vantage V2 to Measure Heart Rate and Heart Rate Variability at Rest
Nuuttila, O., Korhonen, E., Laukkanen, J. A., & Kyröläinen, H. (2021) · Sensors · doi:10.3390/s22010137 · Cited by 47
Du, Y., Li, N., Zhou, L., Yongga, A., Jiang, Y., & He, Y. (2022) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.104133 · Cited by 48
Dehkordi, P., Garde, A., Karlen, W., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611059 · Cited by 52
“PRV has been shown to be sufficiently an accurate estimate of HRV in healthy subjects at rest [7].”
BackgroundPeralta, E., Lázaro, J. M., Bailón, R., Marozas, V., & Gil, E. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab009b · Cited by 48
Evaluation of the Possible Use of PPG Waveform Features Measured at Low Sampling Rate
Fujita, D., & Suzuki, A. (2019) · IEEE Access · doi:10.1109/access.2019.2914498 · Cited by 48
Wei, L., Chen, H., & Wu, G. (2017) · Brain Research · doi:10.1016/j.brainres.2017.12.024 · Cited by 47
“The short-term variability measures, like HF (high frequency) and RMSSD, tend to somewhat overestimate by using pulse rate variability (PRV) (Gil et al., 2010; Schäfer and Vagedes, 2013).”
InfluentialAndersson, L., Claeson, A., Dantoft, T. M., Skovbjerg, S., Lind, N., & Nordin, S. (2015) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-015-1053-y · Cited by 46
“, variability based on ECG) and is more prone to motion artifacts (Schäfer and Vagedes 2013).”
BackgroundMethodHRVCam: robust camera-based measurement of heart rate variability
Pai, A., Veeraraghavan, A., & Sabharwal, A. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.2.022707 · Cited by 47
“10 We propose to model p ð t Þ as a quasi-periodic signal given by EQ-TARGET;temp:intralink-;e005;116;301 p ð t Þ ¼ X a k ð t Þ cos ½ ϕ k ð t Þ(cid:2) : The instantaneous frequency of the PPG signal p ð t Þ captures the HRV. 11 The instantaneous frequency f ð t Þ is the derivative of the instantaneous phase ϕ ð t Þ of…”
BackgroundInfluentialChung, A. H., Gevirtz, R., Gharbo, R. S., Thiam, M. A., & Ginsberg, J. P. (2021) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-021-09519-x · Cited by 47
“A systematic review of HRVB for psychiatric disorders found that it significantly improved clinical symptoms (e.g., anxiety disorders, depression, panic disorder, and PTSD) in 70% of the studies reviewed (Schoenberg & David, 2014).”
BackgroundShen, Q., Yang, X. S., Zou, L., Wei, K., Wang, C., & Liu, G. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3195777 · Cited by 46
“The variation law of HRV signals can be obtained by analyzing PRV signals [13], [54].”
BackgroundMakovac, E., Venezia, A., Hohenschurz-Schmidt, D., Dipasquale, O., Jackson, J. B., Medina, S., O’Daly, O., Williams, S. C., McMahon, S. B., & Howard, M. A. (2021) · The Journal of Physiology · doi:10.1113/jp282013 · Cited by 44
Facial Video-Based Photoplethysmography to Detect HRV at Rest
Moreno, J., Ramos-Castro, J. J., Movellan, J. R., Parrado, E., Rodas, G., & Capdevila, L. (2015) · International Journal of Sports Medicine · doi:10.1055/s-0034-1398530 · Cited by 45
Alterations in electrodermal activity and cardiac parasympathetic tone during hypnosis
Kekecs, Z., Szekely, A., & Varga, K. (2016) · Psychophysiology · doi:10.1111/psyp.12570 · Cited by 47
“PRV is shown to be a good surrogate of HRV when used in a resting state with young participants (Charlot, Cornolo, Brugniaux, Richalet, & Pichon, 2009; Gil et al., 2010; G. Lu et al., 2009; Schäfer & Vagedes, 2013; Selvaraj, Jaryal, Santhosh, Deepak, & Anand, 2008).”
MethodGraham, S. A., Jeste, D. V., Lee, E., Wu, T., Tu, X. M., Kim, H., & Depp, C. A. (2019) · JMIR mhealth and uhealth · doi:10.2196/13757 · Cited by 43
“These blood volume changes allow the determination of a PPG-derived peak-to-peak (P-P) interval, which is a valid proxy measure of the R-R interval derived from ECG recordings [25-27].”
Nardelli, M., Vanello, N., Galperti, G., Greco, A., & Scilingo, E. P. (2020) · Sensors · doi:10.3390/s20113156 · Cited by 47
Photoplethysmographic Waveform Analysis for Autonomic Reactivity Assessment in Depression
Kontaxis, S., Gil, E., Marozas, V., Lázaro, J. M., Pagès, E. G., Miguel, M. P., Siddi, S., Bernal, M. L., Aguiló, J., Haro, J. M., et al. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3025908 · Cited by 41
“ological factors such as respiration [42].”
Mejía‐Mejía, E., May, J. M., Elgendi, M., & Kyriacou, P. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00447-y · Cited by 42
Thielmann, B., Pohl, R., & Böckelmann, I. (2021) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-021-00313-3 · Cited by 43
“Pulse oximeters are suitable for measuring RR intervals (named as pulse rate variability (PRV)) to a very limited degree only [34].”
BackgroundChand, T., Li, M., Jamalabadi, H., Wagner, G., Lord, A., Alizadeh, S., Danyeli, L., Herrmann, L., Walter, M., & Sen, Z. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00645 · Cited by 43
“…of the pulse oximeter in calculating HRV by peak detection algorithms was demonstrated (Chang and Glover, 2009; Verstynen and Deshpande, 2011; Nilsson, 2013; Schäfer and Vagedes, 2013; Caballero-Gaudes and Reynolds, 2017), pulse oximeter measurements are delayed due to the pulse transit time.”
MethodDeep convolutional neural network-based signal quality assessment for photoplethysmogram
Shin, H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105430 · Cited by 42
Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise?
Martín-Escudero, P., Cabanas, A. M., Dotor-Castilla, M. L., Galindo-Canales, M., Miguel‐Tobal, F., Fernández, C., Fuentes, M. E., & Giannetti, R. (2023) · Bioengineering · doi:10.3390/bioengineering10020254 · Cited by 41
The use of heart rate variability in esports: A systematic review
Welsh, M. R., Mosley, E., Laborde, S., Day, M. C., Sharpe, B. T., Burkill, R. A., & Birch, P. D. J. (2023) · Psychology of sport and exercise · doi:10.1016/j.psychsport.2023.102495 · Cited by 44
Type 2 Diabetes Screening Test by Means of a Pulse Oximeter
Monte, E., Luján, M. J. A., Rusiñol, M. T., Fernández, P. J., Manrique, P. N., Triviño, C. A., Miquel, M. P., Rodríguez, M. A., & Burguillos, M. J. G. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2554661 · Cited by 41
“Schäfer and Vagedes [14] provided a thorough summary of the literature referring to the use of the comparison between the PPG technology and the ECG.”
BackgroundInfluentialPeláez‐Coca, M. D., Hernando, A., Lázaro, J. M., & Gil, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3099208 · Cited by 41
“The relative error (efsr,HRV,yi) in PRM and SDNN were lower than for the rest of time indices (Table II).”
MethodResultInfluentialEvaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis
Barrios, L., Oldrati, P., Santini, S., & Lutterotti, A. (2019) · Proceedings of the 13th EAI International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1145/3329189.3329215 · Cited by 43
Fusing Partial Camera Signals for Noncontact Pulse Rate Variability Measurement
McDuff, D., Blackford, E. B., & Estepp, J. R. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2771518 · Cited by 40
“We need to acknowledge that PRV cannot be taken to be identical to HRV in every situation [31], rather surrogacy would ultimately need to be evaluated on an application-specific basis (e.”
BackgroundHeart rate variability over the decades: a scoping review
Sundas, A., Contreras, I., Navarro‐Otano, J., Soler, J., Beneyto, A., & Vehı́, J. (2025) · PeerJ · doi:10.7717/peerj.19347 · Cited by 47
“Many studies try to use PRV as a replacement for HRV ( Schäfer & Vagedes, 2013 ).”
InfluentialLo, J. C., Sehic, E., & Meijer, S. (2017) · Journal of Cognitive Engineering and Decision Making · doi:10.1177/1555343417716040 · Cited by 39
Dur, O., Rhoades, C. E., Ng, M. S., Elsayed, R., van Mourik, R. A., & Majmudar, M. D. (2018) · JMIR mhealth and uhealth · doi:10.2196/11040 · Cited by 38
Rutkowski, S., Szary, P., Sacha, J., & Casaburi, R. H. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.702266 · Cited by 40
Kiselev, A. R., Mironov, S. A., Karavaev, A. S., Kulminskiy, D. D., Skazkina, V. V., Borovkova, E. I., Shvartz, V. A., Пономаренко, В. И., & Prokhorov, M. D. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/580 · Cited by 38
A Proximity Coupling RF Sensor for Wrist Pulse Detection Based on Injection-Locked PLL
Kim, B., Hong, Y., An, Y., Kim, S., Lee, H., Kim, S.-W., Hong, S.-B., Yun, G., & Yook, J. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2549531 · Cited by 37
Impact of antidepressant use on the autonomic nervous system: A meta-analysis and systematic review
Fiani, D., Campbell, H. M., Solmi, M., Fiedorowicz, J. G., & Calarge, C. A. (2023) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2023.03.013 · Cited by 38
Kojori, E. S., Tomasi, D. G., & Volkow, N. D. (2018) · Cerebral Cortex · doi:10.1093/cercor/bhy144 · Cited by 41
“While physical activity and some mental stressors may affect the agreement between pulse rate variability and heart rate variability (Schäfer and Vagedes 2013), pulse rate variability is considered a sufficiently accurate estimate of heart rate variability at rest (Schäfer and Vagedes 2013) in healthy individuals (Bol…”
BackgroundHeart rate variability is associated with outcome in spontaneous intracerebral hemorrhage
Szabo, J., Smielewski, P. S., Czosnyka, M., Jakubíček, S., Krebs, S., Šiarnik, P., & Sykora, M. (2018) · Journal of Critical Care · doi:10.1016/j.jcrc.2018.08.033 · Cited by 36
“Review of the literature comparing HRV parameters derived from ECG and ABP signals indicates overall sufficient comparability [31].”
BackgroundBaldoumas, G., Peschos, D., Tatsis, G., Chronopoulos, S. K., Christofilakis, V., Kostarakis, P., Varotsos, P. A., Sarlis, N. V., Skordas, E. S., Bechlioulis, A., et al. (2019) · Electronics · doi:10.3390/electronics8111288 · Cited by 37
“It has been demonstrated that the PPG signal can replace the ECG recordings for the extraction of HRV indices, especially in monitoring healthy individuals at rest [52,53].”
BackgroundCorreia, B., Dias, N. S., Costa, P., & Pêgo, J. M. (2020) · Sensors · doi:10.3390/s20143905 · Cited by 36
Posada-Quintero, H. F., Delisle-Rodríguez, D., Cuadra, M. B., & Prieto, R. R. F. D. L. V. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/2/179 · Cited by 35
“…works have found that pulse rate variability (PRV), extracted from photoplethysmography (PPG), could be used as an alternative measurement of HRV (Hayano et al 2005, Lu et al 2008, Selvaraj et al 2008, Charlot et al 2009, Lu and Yang 2009, Lu et al 2009, Gil et al 2010, Schäfer and Vagedes 2012).”
MethodStress assessment by means of heart rate derived from functional near-infrared spectroscopy
Hakimi, N., & Setarehdan, S. K. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.11.115001 · Cited by 38
Liu, B., Zhang, Z., Di, X., Wang, X., Xie, L., Xie, W., & Zhang, J. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.733264 · Cited by 35
“Although studies vary considerably because of diverse experimental settings and/or analysis methods, a unifying result is that the spectrum power of PRV (especially the HF band) is always larger than that of HRV (Schafer and Vagedes, 2013), which was also evident in our study (Figure 2).”
BackgroundMethodPulse Oximetry: The Working Principle, Signal Formation, and Applications
Leppänen, T., Kainulainen, S., Korkalainen, H., Sillanmäki, S., Kulkas, A., Töyräs, J., & Nikkonen, S. (2022) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-06413-5_12 · Cited by 46
Chen, W., Yi, Z., Lim, L. J. R., Lim, R. Q. R., Zhang, A., Qian, Z., Huang, J., He, J., & Лю, Б. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1420100 · Cited by 40
Evaluating the accuracy of wearable heart rate monitors
Ge, Z., Prasad, P. W. C., Costadopoulos, N., Alsadoon, A., Singh, A. K., & Elchouemi, A. (2016) · International Conference on Advances in Computing, Communication & Automation (ICACCA) · doi:10.1109/icaccaf.2016.7748986 · Cited by 35
“Schafer and Vagedes [7] reviewed studies investigating the accuracy of pulse rate variability (PRV) as an estimate of HRV utilizing a PPG sensor.”
BackgroundHeart Rate Variability and Its Relation to Chronic Kidney Disease: Results From the PREVEND Study
Thio, C. H. L., van Roon, A. M., Lefrandt, J. D., Gansevoort, R. T., & Snieder, H. (2018) · Psychosomatic Medicine · doi:10.1097/psy.0000000000000556 · Cited by 35
“In individuals at rest, pulse rate variability is considered an accurate estimate of HRV (43).”
BackgroundAssessing Drivers’ Physiological Responses Using Consumer Grade Devices
Gruden, T., Stojmenova, K., Sodnik, J., & Jakus, G. (2019) · Applied Sciences · doi:10.3390/app9245353 · Cited by 34
Kumar, C. K., Manaswini, M., Maruthy, K. N., Kumar, A. V. S., & kumar, K. M. (2021) · Clinical Epidemiology and Global Health · doi:10.1016/j.cegh.2021.100698 · Cited by 34
Video pulse rate variability analysis in stationary and motion conditions
Rodríguez, A., & Ramos-Castro, J. J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0437-0 · Cited by 35
“Moreover, some authors have investigated the possibility of measuring pulse rate variability (PRV) as a surrogate of HRV showing close agreement [10, 11].”
BackgroundLam, E., Aratia, S., Wang, J., & Tung, J. Y. (2020) · JMIR Biomedical Engineering · doi:10.2196/17355 · Cited by 36
Jamieson, A., Chico, T., Jones, S. H., Chaturvedi, N., Hughes, A. D., & Orini, M. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-025-00082-6 · Cited by 41
“When measured using PPG, the most appropriate metric to use would be pulse rate variability 44,45 , which is derivedfromconsecutivepulsesrecordedinthewristor fi ngerandnotfrom consecutive R-R intervals on an ECG.”
InfluentialWang, H., Wang, L., Sun, N., Yao, Y., Hao, L., Xu, L., & Greenwald, S. E. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2019.01563 · Cited by 39
“Many types of sensors have been developed for the non-invasive detection of pulse waves (Schafer and Vagedes, 2013; Meidert et al., 2014; Stea et al., 2014; Boutry et al., 2015; Kamshilin et al., 2016).”
BackgroundKeller, M., Pelz, H., Perlitz, V., Zweerings, J., Roecher, E., Baqapuri, H. I., & Mathiak, K. (2020) · Psychophysiology · doi:10.1111/psyp.13594 · Cited by 33
Ushakov, N. A., Александрович, М. А., Kulik, D., & Борисович, Л. Л. (2021) · Photonics · doi:10.3390/photonics8050142 · Cited by 33
Sheridan, D. C., Baker, S. D., Dehart, R., Lin, A. L., Hansen, M. L., Tereshchenko, L. G., Le, N., Newgard, C. D., & Nagel, B. J. (2021) · Psychiatry Investigation · doi:10.30773/pi.2021.0057 · Cited by 33
Azulay, N., Olsen, R. B., Nielsen, C. S., Stubhaug, A., Jenssen, T. G., Schirmer, H., Frigessi, A., Rosseland, L. A., & Tronstad, C. (2022) · Scientific Reports · doi:10.1038/s41598-022-15824-0 · Cited by 33
Papini, G. B., Fonseca, P. M., Eerikäinen, L. M., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae7f8 · Cited by 32
Chen, X., HUANG, Y.-Y., Yun, F., Chen, T., & Li, J. (2015) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2015.2784 · Cited by 32
Reliability of Short-Term Heart Rate Variability Indexes Assessed through Photoplethysmography
Pernice, R., Javorka, M., Krohová, J., Czippelová, B., Turianiková, Z., Busacca, A., & Faes, L. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513634 · Cited by 31
“In the recent past, a number of studies have investigated the agreement between HRV and PRV, indicating that such an agreement varies depending on the considered descriptive measure of HRV and on the physiological condition (see [8] for a comprehensive review).”
BackgroundSpeckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge
Dunn, C. E., Monroe, D. C., Crouzet, C., Hicks, J. W., & Choi, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-50526-0 · Cited by 31
Validation of the Polar OH1 and M600 optical heart rate sensors during front crawl swim training
Olstad, B. H., & Zinner, C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0231522 · Cited by 34
Wei, K., Zou, L., Liu, G., & Wang, C. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106469 · Cited by 36
Düking, P., Zinner, C., Reed, J. L., Holmberg, H., & Sperlich, B. (2020) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13802 · Cited by 34
Wadehn, F., Carnal, D., & Loeliger, H. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319225 · Cited by 29
“Pulse oximetry is increasingly proving to be a useful tool for unobtrusive monitoring of essential physiological parameters such as the heart rate (HR) and the pulse rate variability (PRV), a surrogate measure for the heart rate variability (HRV), in both home-care and intensive care environments [1].”
BackgroundDon’t add or miss a beat: a guide to cleaner heart rate variability recordings.
Shaffer, F., & Combatalade, D. C. (2013) · Biofeedback · doi:10.5298/1081-5937-41.3.04 · Cited by 30
“The ECG allows a more accurate calculation of the interbeat interval, especially during psychological stressors (Schäfer & Vagedes, 2013).”
BackgroundHeart-brain synchronization breakdown in Parkinson’s disease
Iniguez, M., Jiménez-Marín, A., Erramuzpe, A., Acera, M., Tijero, B., Murueta‐Goyena, A., Pino, R. D., Fernández, T., Carmona‐Abellán, M., Cabrera‐Zubizarreta, A., et al. (2022) · npj Parkinson s Disease · doi:10.1038/s41531-022-00323-w · Cited by 35
Assessment of skin blood flow following spinal manual therapy: A systematic review
Zegarra-Parodi, R., Park, P. Y. S., Heath, D. M., Makin, I. R. S., Degenhardt, B. F., & Roustit, M. (2014) · Manual Therapy · doi:10.1016/j.math.2014.08.011 · Cited by 30
“The SSNA could be noninvasively assessed with pulse rate variability, a frequency-domain analysis of a PPG signal that is considered an accurate estimate of heart rate variability in quiet and controlled conditions (Schafer and Vagedes, 2013).”
BackgroundElstad, M., Walløe, L., Holme, N. L. A., Maes, E., & Thoresen, M. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-3042-3 · Cited by 30
“Pulse rate is in good–moderate accordance with HR in healthy subjects at rest (Schafer and Vagedes 2013).”
ResultMuñoz, J. E., Gouveia, É. R., Cameirão, M. S., & Badia, S. B. I. (2017) · Multimedia Tools and Applications · doi:10.1007/s11042-017-5069-z · Cited by 30
Heart rate response to cognitive load as a marker of depression and increased anxiety
Alshanskaia, E. I., Alexandrovna, Z. N., Поликанова, И. С., & Martynova, O. (2024) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2024.1355846 · Cited by 34
“Thus, despite ECG being considered a more reliable method for measuring HRV (56), and the relative scarcity of research into PPG signals in relation to depression and anxiety, our results suggest that PPG is an effective tool for gauging depression and trait anxiety through HR measurement.”
MethodPosada-Quintero, H. F., Reljin, N., Moutran, A., Georgopalis, D., Lee, E. C., Giersch, G. E. W., Casa, D. J., & Chon, K. H. (2019) · Nutrients · doi:10.3390/nu12010042 · Cited by 29
“[18–20], with the advantage that photoplethysmography is a low-cost optical technique [21] that is much simpler to use than the electrocardiogram and is easily deployed in smartphones and wearable devices [22–24].”
BackgroundSingstad, B.-J., Azulay, N., Bjurstedt, A., Bjørndal, S. S., Drageseth, M. F., Engeset, P., Eriksen, K., Gidey, M. Y., Granum, E. O., Greaker, M. G., et al. (2021) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2021-0012 · Cited by 29
“Several studies have compared HRV derived from PPG with ECG-based HRV as a reference [8-10] and good agreement has generally been demonstrated for healthy subjects at rest, but moderate physical, and sometimes mental stress, tends to diminish the agreement [8,11,12].”
BackgroundUsing imaging photoplethysmography for heart rate estimation in non-human primates
Михайлович, У. А., Moeller, S., Kagan, I., Gail, A., Treue, S., & Wolf, F. (2018) · PLoS ONE · doi:10.1371/journal.pone.0202581 · Cited by 29
Co-Located Multimodal Sensing: A Next Generation Solution for Wearable Health
Goverdovsky, V., Looney, D., Kidmose, P., Papavassiliou, C., & Mandic, D. P. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2338612 · Cited by 28
“PPG peaks is a good proxy for heart rate variability [21], and”
BackgroundEmotional metacognition: stimulus valence modulates cardiac arousal and metamemory
Legrand, N., Engen, S. S., Corrêa, C. M. C., Mathiasen, N. K., Nikolova, N. E., Fardo, F., & Allen, M. (2020) · Cognition & Emotion · doi:10.1080/02699931.2020.1859993 · Cited by 30
High natural killer cell number might identify stroke patients at risk of developing infections
Raedt, S. D., Vos, A. D., Vanbinst, A., Waele, M. D., Coomans, D. H., Buyl, R., & Keyser, J. D. (2015) · Neurology Neuroimmunology & Neuroinflammation · doi:10.1212/nxi.0000000000000071 · Cited by 28
“PRV derived from noninvasive blood pressure waveforms corresponds sufficiently with traditional HRV derived from ECG in subjects at rest.(10) PRV was calculated using Kubios software (University of Eastern Finland, Kuopio, Finland).”
MethodDias, D. P. M., Silva, L. E. V., Katayama, P. L., Silva, C. A. A., Salgado, H. C., & Fazan, R. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/7/1120 · Cited by 28
“Although RR has been considered the gold standard for HRV analysis (Russoniello et al 2013, Schäfer and Vagedes 2013), PI series are commonly used for this purpose (Di Rienzo et al 1996, Honzíková et al 2003, Silva et al 2015).”
MethodMontgomery, S. M., Nair, N., Chen, P., & Dikker, S. (2024) · Measurement Sensors · doi:10.1016/j.measen.2024.101075 · Cited by 28
PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Lapsa, D., Janeliukštis, R., Metshein, M., & Selavo, L. (2024) · Applied Sciences · doi:10.3390/app14177451 · Cited by 30
Fuse, S., Endo, T., Tanaka, R., Kuroiwa, M., Ando, A., Kume, A., Yamamoto, A., Kuribayashi, K., Somekawa, S., Takeshita, M., et al. (2020) · Nutrients · doi:10.3390/nu12092676 · Cited by 27
Konstantinou, P., Trigeorgi, A., Georgiou, C., Gloster, A. T., Panayiotou, G., & Karekla, M. (2020) · Psychophysiology · doi:10.1111/psyp.13551 · Cited by 27
“…recordings of only a few minutes are sufficient for the calculation of certain HRV parameters (Hamilton, Mckechnie, & Macfarlane, 2004; Migliaro, Canetti, Contreras, & Hakas, 2003; Schäfer & Vagedes, 2013) and this is why we decided to proceed with the HRV analysis during the experimental phase.”
BackgroundMaternal bonding in childhood moderates autonomic responses to distress stimuli in adult males
Dalsant, A., Truzzi, A., Setoh, P., & Esposito, G. (2015) · Behavioural Brain Research · doi:10.1016/j.bbr.2015.06.026 · Cited by 28
Solorzano, C. S., Violani, C., & Grano, C. (2022) · Journal of Affective Disorders · doi:10.1016/j.jad.2022.09.056 · Cited by 26
Heart Rate Variability Analysis: How Much Artifact Can We Remove?
Sheridan, D. C., Dehart, R., Lin, A. L., Sabbaj, M., & Baker, S. D. (2020) · Psychiatry Investigation · doi:10.30773/pi.2020.0168 · Cited by 26
Kimmel, M., Fransson, E., Cunningham, J. L., Bränn, E., Grewen, K., Boschiero, D., Chrousos, G. P., Meltzer-Brody, S. E., & Skalkidou, A. (2021) · Translational Psychiatry · doi:10.1038/s41398-021-01401-y · Cited by 27
Mejía‐Mejía, E., May, J. M., & Kyriacou, P. A. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106724 · Cited by 26
Effects of Missing Data on Heart Rate Variability Metrics
Cajal, D., Hernando, D., Lázaro, J. M., Laguna, P., Gil, E., & Bailón, R. (2022) · Sensors · doi:10.3390/s22155774 · Cited by 26
“Despite pulse rate variability being different from HRV, it can be used as a surrogate in many practical situations [8,9].”
BackgroundEnhancing the Robustness of Smartphone Photoplethysmography: A Signal Quality Index Approach
Liu, I., Ni, S., & Peng, K. (2020) · Sensors · doi:10.3390/s20071923 · Cited by 26
“The two measurements are considered to have a good or acceptable agreement when the BAR is less than 10% or 20% [40, 66] .”
BackgroundComparison of Wearable and Clinical Devices for Acquisition of Peripheral Nervous System Signals
Bizzego, A., Gabrieli, G., Furlanello, C., & Esposito, G. (2020) · Sensors · doi:10.3390/s20236778 · Cited by 25
“This result is expected as the beat detection in BVP signals is in general more difficult due to posture and individual physiological characteristics [26].”
BackgroundSato, S., Hiratsuka, T., Hasegawa, K., Watanabe, K., Obara, Y., Kariya, N., Shinba, T., & Matsui, T. (2023) · Sensors · doi:10.3390/s23083867 · Cited by 25
Metadata
- Authors
- Schäfer, A., & Vagedes, J.
- Affiliations
- Academic Research in Complementary and Integrative Medicine (DE)
- University Children's Hospital Tübingen (DE)
- Corresponding author
- Vagedes, Jan
- ORCID
- Vagedes, Jan
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 166
- Issue
- 1
- Pages
- 15-29
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W188715143
- Cited by
- 661
- References
- 114
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 56 · 2023: 52 · 2022: 57 · 2021: 72 · 2020: 67 · 2019: 49 · 2018: 59 · 2017: 40 · 2016: 40 · 2015: 29 · 2014: 19 · 2013: 9
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- pulse rate variability, heart rate variability, photoplethysmography, pulse oximetry, RR interval, measurement accuracy, physical activity, psychological stress, sensor position, detection algorithm, ambulatory monitoring
- MeSH terms
- Electrocardiography, Heart Rate, Humans, Motor Activity, Pulse, Rest, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review