How accurate is pulse rate variability as an estimate of heart rate variability?
Abstract
Background The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV.Methods We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography).Results/conclusions Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A comparative review of photoplethysmography against ECG stated that photoplethysmography can be used during rest but not during stress (Schafer and Vagedes, 2013).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Schafer and Vagedes, 2013
In the citing paper
“However, it cannot yet be considered to be a surrogate during exercise or stress [17], [129].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
In the citing paper
“Nonetheless, reviews have concluded that PRV is a good surrogate of HRV for certain applications at rest.”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Flagged first, then by citations
2 of the 114 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Herzman, 1937, Observations on the finger volume pulse recorded photoelectrically, Am J Physiol, 119, 334
- Janssen, 1994, Methods in heart rate variability analysis: may the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm?, High Blood Pressure, 3, 23
- Khandoker, 2011, Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea, Med Eng Phys, 33, 204, 10.1016/j.medengphy.2010.09.020 · DOI
Cited by
Sorted by citations
Items 501–600 of 660
Li, F., & Jackson, T. (2021) · Psychophysiology · doi:10.1111/psyp.13962 · Cited by 2
Poincaré plots to analyze photoplethysmography signal between non-smokers and smokers
Haryadi, B., Chang, P.-H., Akrom, A., Raharjo, A. Q., & Prakoso, G. (2022) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijece.v12i2.pp1565-1570 · Cited by 2
A Modified Mask for Continuous Cardiac Monitoring during Positive Airway Pressure Therapy
Gardner, M., Randhawa, S., Malouf, G., & Reynolds, K. J. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513399 · Cited by 2
Sustained Attention Detection System in Learning Environments
da Costa, B. N., Postolache, O. A., & Araujo, J. (2020) · International Conference and Exposition on Electrical and Power Engineering (EPE) · doi:10.1109/epe50722.2020.9305027 · Cited by 2
Relevant Errors Relating to the Measuring Method
Sammito, S., & Böckelmann, I. (2016) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2016.0374a · Cited by 2
Instant Automated Inference of Perceived Mental Stress through Smartphone PPG and Thermal ImagingPreprint
Cho, Y., Julier, S., & Bianchi‐Berthouze, N. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/326157 · Cited by 2
Ferrer-Mileo, V. (2019) · doi:10.5821/dissertation-2117-170437 · Cited by 2
“Finalmente, es importante destacar que con los métodos expuestos anteriormente se puede medir el ciclo cardíaco completo pero que pueden aparecer diferencias en la estimación de diversos parámetros como, por ejemplo, la duración del ciclo cardíaco [37-40].”
BackgroundInfluentialRudstam, G. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau611841551 · Cited by 4
Sinichi, M., Gevonden, M. J., & Krabbendam, L. (2024) · Journal of Open Source Software · doi:10.21105/joss.06240 · Cited by 2
Kechris, C., & Delopoulos, A. N. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629595 · Cited by 1
“According to [8], although PPG motion artifact reduction methods exist, they have not been employed on HRV estimation applications.”
MethodZhu, S., Liu, S., Jing, X., Li, B., Liu, H., Yang, Y., & She, C. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad3dbf · Cited by 1
Yang, K.-Y., Yoo, G., Kim, C. H., Lim, S., & Jeon, J. (2024) · The Korean Journal of Community Living Science · doi:10.7856/kjcls.2024.35.3.497 · Cited by 1
Bai, Z., Wu, P., Geng, F., Zhang, H., Chen, X., Du, L., Wang, P., Li, X., Fang, Z., & Wu, Y. (2024) · Bioengineering · doi:10.3390/bioengineering11121219 · Cited by 1
Spontaneous motor tempo modulates the effect of music tempo on arousal levels
Hine, K., Abe, K., & Nakauchi, S. (2025) · Psychology of Music · doi:10.1177/03057356241311288 · Cited by 1
“It has been reported that PR is a sufficiently accurate estimate of heart rate in healthy participants at rest (Schäfer & Vagedes, 2013).”
Liu, Q., Ling, B. W., & Ding, J. (2025) · Signal Image and Video Processing · doi:10.1007/s11760-025-03946-7 · Cited by 1
“From here, there are more advantages of using the PPGs compared to using the ECGs or the other forms of the sig - nals for performing the heart rate measurement [ 9].”
Ultra-Short Term Heart Rate Variability Estimation Using PPG and End-to-End Deep Learning
Wang, W., & Najafizadeh, L. (2024) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/ieeeconf60004.2024.10943067 · Cited by 1
A Novel Nonlinear Method for Cardiovascular Data Synchronization
Padovano, D., Martínez‐Rodrigo, A., Marwan, N., Muñoz, S. M., Rieta, J. J., & Alcaraz, R. (2025) · IEEE Access · doi:10.1109/access.2025.3571070 · Cited by 2
“Schäfer and Vagedes [23] reviewed numerous studies, consistently finding high concordance between PRV and HRV through LC. Elgendi et al. [24] also demonstrated reliable PRV using LC in automatic peak detection in PPG signals.”
Wiśniewska, M., Piejka, A., Wolak, T. P., & Okruszek, Ł. (2025) · Cerebral Cortex · doi:10.1093/cercor/bhaf206 · Cited by 1
Salsano, I., Giulietti, G., Ottaviani, C., Tain, R., Williams, D. P., Antonucci, G., Santangelo, V., & Thayer, J. F. (2025) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2025.113249 · Cited by 1
Wearable Devices Methodology: Opportunities and Challenges in Human Resource Management
Massaro, S., Yang, T. Y. K., & Christopoulos, G. I. (2025) · Human Resource Management Journal · doi:10.1111/1748-8583.70014 · Cited by 3
Abdrasulova, N., Aleksanyan, M., Kim, M. J., & Ahn, J. M. (2025) · Sensors · doi:10.3390/s25227091 · Cited by 1
Ardaillon, H., Dubois, A., Ndocko, K.-M., Etienne, J., Tallon-Baudry, C., & Luauté, J. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.2111469 · Cited by 1
Oropesa, P. T., Sánchez-Pay, A., Conesa‐Ros, E., Bianco, A., Ruiz-Navarro, J. J., & Martínez-Cava, A. (2025) · Applied Sciences · doi:10.3390/app16010126 · Cited by 1
Rominger, C., Koschutnig, K., Fink, A., & Schwerdtfeger, A. R. (2026) · Autonomic Neuroscience · doi:10.1016/j.autneu.2026.103389 · Cited by 1
Digital biomarkers and ambulatory seizure detection in epilepsy clinical trials
Russo, E. E., Simmatis, L. E. R., Wu, T., Kadak, K., Harmsen, I. E., & Samuel, N. (2026) · Discover Neuroscience · doi:10.1186/s13064-026-00244-x · Cited by 1
Azam, M. B., & Singh, S. I. (2026) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-026-03455-8 · Cited by 1
“…PRV and HRV show a high correlation in resting states, PPG signals are prone to artifacts from motion, vasoconstriction, and skin pigmentation, which can reduce the accuracy of PRV, and discrepancies between PRV and HRV tend to be higher during physiological stress and in clinical settings [10].”
Wearable ECG and PPG for anxiety detection: a translational digital medicine perspective
Elgendi, M., Elkhalifa, A., Alhashmi, N., Aldahmani, A., Aljneibi, N., Alamro, D., Jelinek, H. F., Khandoker, A. H., & Ward, R. K. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02620-7 · Cited by 2
Rho, G., Carbonaro, N., Laurino, M., Tognetti, A., & Greco, A. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110531 · Cited by 1
Tayade, A., Kumar, S., Shrivastava, A., & Ravi, B. (2026) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2026.111835 · Cited by 1
Аbzaliyev, K., Bugibayeva, A., Abzaliyeva, S., Akhmetova, G., Balkanay, G., Omarbayeva, A., Anartayev, S., Zarubekova, N., & Сулейменова, М. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15135141 · Cited by 1
Hu, J., Xiao, Y., Ma, G., Yao, B., Li, J., An, H., Wang, G., & Chen, Y. (2026) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-026-09797-3 · Cited by 1
Xu, S., Liu, H., Liu, Z., Su, P., & Gu, Z. (2026) · Sensors · doi:10.3390/s26165192 · Cited by 1
Yuda, E., Morikawa, N., & Hayano, J. (2026) · Clocks & Sleep · doi:10.3390/clockssleep8030054 · Cited by 1
Schamber, G., Meinicke, E., & Schäfer, T. (2015) · Zeitschrift für Neuropsychologie · doi:10.1024/1016-264x/a000155 · Cited by 1
Thomashow, M. A., & Goldschlager, N. (2018) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.2095 · Cited by 1
Prediction of Menstrual Cycle Phase by Wearable Heart Rate Sensor
Hayano, J., & Yuda, E. (2020) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-7998-3970-5.ch001 · Cited by 1
An effective Branch-and-Bound algorithm to solve the k-longest common subsequence problem
Huang, G., & Lim, A. E. B. (2004) · European Conference on Artificial Intelligence · Cited by 1
Interbeat Interval Detection from Synthetic Photoplethysmography Signals
Aguet, C., Jeanningros, L., Braun, F., Zaen, J. V., & Lemay, M. (2021) · Computing in cardiology · doi:10.23919/cinc53138.2021.9662897 · Cited by 1
“By analogy, the interbeat intervals (IBIs) can be extracted from PPG signals to retrieve pulse rate variability information as surrogate of HRV [2].”
MethodValenti, S., Volpes, G., Parisi, A., Pernice, R., Stivala, S. S., Faes, L., & Busacca, A. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856478 · Cited by 1
López-Galán, E., Vitón-Castillo, A. A., Carrazana‐Escalona, R., Planas‐Rodríguez, M., Fernández-García, A., Cutiño‐Clavel, I., Pascau-Simón, A., Connes, P., Sánchez-Hechavarría, M. E., & Muñoz-Bustos, G. A. (2023) · Medicina · doi:10.3390/medicina59061141 · Cited by 1
A non-invasive, concealed electrocardiogram and bioimpedance measurement system for captive primates
Serrano‐Finetti, E., Hornero, G., Álvarez, S. M., López, F. N., Crailsheim, D., Feliu, O., & Casas, Ó. (2023) · Journal of Experimental Biology · doi:10.1242/jeb.245783 · Cited by 1
(2023) · Advances in Machine Learning & Artificial Intelligence · doi:10.33140/amlai.04.02.05 · Cited by 1
Pulse rate during running 5 laps: comparative study before and after dehydration?
Apriandi, D., Salacup, V. L. D., Butali, R. A., Cadiente, D. S. A., Ardian, R., Septianto, I., & Azrina, J. (2023) · Tanjungpura Journal of Coaching Research · doi:10.26418/tajor.v1i3.73047 · Cited by 1
Predicting Heart Rate Variability from Heart Rate and Step Count for University Student Weekdays
Warren, J., Ni, L., Fry, B., Stowell, M., Gardiner, C., Whittaker, R., Tane, T., & Dobson, R. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781904 · Cited by 1
“Excluding ectopic beats and arrhythmia we have the duration between ‘normal’ beats (and thus may refer to the NN interval in lieu of the RR interval) [6].”
An HRV-fMRI-DTI Integrated Framework at Ultra-High Magnetic Field
Goffi, F., Scalbi, E., Tassi, E., Squarcina, L., Tosetti, M., Bianchi, A. M., Brambilla, P., & Maggioni, E. (2024) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine62247.2024.10795924 · Cited by 1
Toward Camera-PRV-Based Early Warning in Hospital ICU: A Pilot Study
Wang, H., Huang, J., Wang, G., Lou, J., Tancheng, Y., Huang, D., Lu, H., & Wang, W. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3566990 · Cited by 1
“The relationship between these diseases and the ANS may also impact the interpretation of HRV [23], [26], and the evaluation of PRV in patients with multiple comorbidities remains a challenge in clinical trial [25].”
Nagy, Á., Róka, Z. L., Jánoki, I. G., Siket, M., Földesy, P., Varga, J., Szabó, M., & Zarándy, Á. (2025) · Applied Sciences · doi:10.3390/app15126779 · Cited by 1
Analyzing heart rate variability using a photoplethysmographic signal measuring system
Chen, Y., Shieh, J.-S., Fan, S., Chiang, W.-T., Abbod, M., & Liu, Q. (2016) · IEEE/ASME International Conference on Mechatronic and Embedded Systems and Applications · doi:10.1109/mesa.2016.7587195 · Cited by 1
“On the other hand, the equipment based on photoplethysmography (PPG) using optical fibres to measure HR and HRV have been developed in place of measuring ECG signal [16, 17].”
BackgroundLoudon, G. H., & Zampelis, D. (2017) · Creativity and Cognition · doi:10.1145/3059454.3084340 · Cited by 1
“Heart rate variability (HRV) can be measured from the variation in consecutive pulse cycle intervals using techniques such as Photoplethysmography [4][5][6].”
MethodSnizhko, Y. M., Boiko, O. O., Botsva, N. P., Chernetchenko, D. V., & Milyh, M. M. (2018) · Regulatory Mechanisms in Biosystems · doi:10.15421/021849 · Cited by 1
“…of R-R intervals in the electrocardiogram, they are using time intervals between peak values in the photoplethysmography signal, which also reflects the heart rate, since the mechanical activity of the heart is related to its electrical activity (Schäfer & Vagedes, 2013; Kavsaoǧlu et al., 2016).”
BackgroundMethodPhotoplethysmographic Sensors in Automatized Diagnosis of the Cardiovascular System
Gospodinov, M. V., Georgieva-Tsaneva, G. N., Gospodinova, E. P., & Cheshmedzhiev, K. (2019) · Advances in systems analysis, software engineering, and high performance computing book series · doi:10.4018/978-1-5225-7879-6.ch011 · Cited by 1
An Exploration of Influence of Duration on Physiological Effects of Asanas
Subudhi, D., & Manivannan, M. (2020) · Advances in medical diagnosis, treatment, and care (AMDTC) book series · doi:10.4018/978-1-7998-3254-6.ch025 · Cited by 1
Smart Wireless Wearable ECG to Measure Heart Function
Mamunur, R. M., Bakar, S. A., Zhang, Z., Li, Z., & Li, Z. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1624/6/062012 · Cited by 1
Problem of power spectra estimation in application to the analysis of heart rate variability
Ishbulatov, Y. M., Gridnev, V. I., Пономаренко, В. И., Ezhov, D. M., Prokhorov, M. D., Kiselev, A. R., & Karavaev, A. S. (2023) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-022-00731-2 · Cited by 1
Polymeric Optical Fibres for Biomedical Sensing
Krehel, M. (2014) · Zurich Open Repository and Archive (University of Zurich) · doi:10.3929/ethz-a-010276893 · Cited by 1
van de Water, L. F. (2017) · Utrecht University Repository (Utrecht University) · Cited by 1
Wearable Blood Pressure Device For Detection of Orthostatic Hypotension
Hafez, M. (2020) · OpenCommons - UConn (University of Connecticut) · Cited by 1
Warth, M., Macián, A. M., Keßler, J., Hillecke, S. H. T. K., & Bardenheuer, H. J. (2016) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2016.0374b · Cited by 1
Methodological Shortcomings of Wrist-Worn Heart Rate Monitors Validations (Preprint)Preprint
Sartor, F., Papini, G. B., Cox, L. G. E., & Cleland, J. G. F. (2018) · doi:10.2196/preprints.10108 · Cited by 1
Duration of Photoplethysmographic Signals for the Extraction of Pulse Rate VariabilityPreprint
Mejía‐Mejía, E., & Kyriacou, P. A. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4136038 · Cited by 1
Role of nocturnal pulse rate variability in predicting clinical outcome for patients with OSA
Sankari, A. (2022) · Journal of the American Geriatrics Society · doi:10.1111/jgs.18041 · Cited by 1
Review and Content Analysis of Mobile Applications for Heart Rate Variability (Preprint)Preprint
de Jager, E., Caulfield, B., Angelidi, E., & Holden, S. (2025) · doi:10.2196/preprints.84764 · Cited by 1
Heart Rate Variability Analysis Based on Instantaneous Frequency Estimation
Feng, D. (2015) · Research Repository (Delft University of Technology)
Can Heart Rate Variability (HRV) be Determined Using Short-Term Photoplethysmograms?Preprint
Elgendi, M., Norton, I., Brearley, M. B., Dokos, S., Abbott, D., & Schuurmans, D. (2013) · viXra
Uuskoski, M. (2015) · Jyväskylä University Digital Archive (University of Jyväskylä)
An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability
Yang, Y. L., & Shin, H. (2016) · The Transactions of The Korean Institute of Electrical Engineers · doi:10.5370/kiee.2016.65.7.1247
Assessment and Mechanisms of Autonomic Function in Health and Disease
Pellegrino, P. R. (2016) · DigitalCommons@UNMC
Age-Related Alterations in the Sign Series Entropy of Short-Term Pulse Rate Variability
Chou, Y., & Zhang, A. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-22053-6_76
John, L. S. (2017) · UVic’s Research and Learning Repository (University of Victoria)
Clinical decision-making of anesthesiology residents in emergency medical care
Maceina, T., Valickas, G., Šipylaitė, J., Macas, A., Olševska, J., & Puidokas, P. (2016) · International Journal of Psychology a Biopsychosocial Approach · doi:10.7220/2345-024x.19.1
“However, more accurate information about the heart rhythm and HRV could be obtained using an electrocardiograph (Giardino, Lehrer & Edelberg, 2002; Schafer & Vagedes, 2013).”
MethodKatayama, P. L. (2018) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.17.2018.tde-20072018-091306
Kardiovaskuläre autonome Dysfunktion bei psychischen Erkrankungen
Hösl, K. M., Geiss, L., & Hillemacher, T. (2018) · NeuroTransmitter · doi:10.1007/s15016-018-6497-3
Historical Development of HRV Analysis
Voss, A. (2017) · CRC Press eBooks · doi:10.4324/9781315372921-2
“However, pulse rate variability as an estimate of HRV has proved to be sufficiently accurate only for healthy (and mostly younger) subjects at rest (Schafer and Vagedes 2013).”
BackgroundPulse Transition Time Method for Unobtrusive Blood Pressure Estimation
Ruano, M. G., Fazel, A. S., Jiménez-Martín, A., Ruano, A. E., & García-Domínguez, J. J. (2019) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-31635-8_183
Koskinen, R. (2019) · Jyväskylä University Digital Archive (University of Jyväskylä)
Commodity Sensors, Physiological Signals, Research Opportunities, and Practical Issues
Stanford, M. W., & Stanford, V. M. (2019) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb47826.2019.9037855
Dehghanojamahalleh, S., Balasubramanian, V., & Kaya, M. (2020) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2020.2983147
The Use of Photoplethysmography to Study Emergency Physicians During Shifts
Peters, G. A. (2020) · Digital Access to Scholarship at Harvard (DASH) (Harvard University)
Dynamics of peripheral blood flow across sleep stagesPreprint
Fan, Z., Suzuki, Y., Jiang, L., Okabe, S., Honda, S., Endo, J., Watanabe, T., & Abe, T. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.11.04.467081
“Studies have shown that PRV is consistent with HRV during resting states,[9,10] such as sleep.”
BackgroundGagnon, J., Khau, M., Lavoie-Hudon, L., Vachon, F., Drapeau, V., & Tremblay, S. (2022) · doi:10.2196/preprints.37885
Prediction of Menstrual Cycle Phase by Wearable Heart Rate Sensor
Hayano, J., & Yuda, E. (2022) · IGI Global eBooks · doi:10.4018/978-1-6684-6299-7.ch028
Düking, P., & Sperlich, B. (2022) · B&G Bewegungstherapie und Gesundheitssport · doi:10.1055/a-1871-0043
Sabil, A., Blanchard, M., Gervès‐Pinquié, C., Gagnadoux, F., & Cohort, B. O. T. P. D. L. L. S. (2022) · Journal of the American Geriatrics Society · doi:10.1111/jgs.18040
“Sankari,(2) certain studies have reported uncertainty about the accuracy of PRV compared to heart rate variability (HRV) in severe OSA patients and particularly for the frequency-domain indices.(3,4) However, more recent studies have shown that PRV is an accurate estimation of HRV in subjects at rest or in non-station…”
BackgroundBudinskaya, K., Pírek, O., Rafčíková, N., Nádeníčková, O., Bednaříková, K., Hrstková, H., Dobšák, P., & Nováková, Z. (2022) · Children · doi:10.3390/children9111610
“Generally, sympathovagal activity is analyzed by a heart rate variability examination, but it was also shown that PWVV could be used as a marker of autonomic nerve system activity [33].”
BackgroundIlie, A. C., Turcu, A.-M., Alexa‐Stratulat, T., Ștefăniu, R., Țăranu, S. M., Rotariu, C., Costin, H. N., & Alexa, I. D. (2022) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb55594.2022.9991453
“Another commonly used instrument to determine HRV is ECG Holter.”
MethodInfluentialInfluence of temperature on heart rate variability parameters
Murtazin, A. A., Maksjutov, N. F., Usenko, A. B., Izotov, A., Malsagova, K. A., Butkova, T. V., Stepanov, A. A., Petrov, A. A., & Balakin, E. I. (2023) · Russian Journal for Personalized Medicine · doi:10.18705/2782-3806-2022-2-6-42-53
Qi, Y., Zhang, A., Ma, Y., Chang, T., & Xu, J. (2023) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2023.2175061
“The paired T-test cannot thoroughly examine random errors, and the PCC is not sensitive to the relative error [23].”
BackgroundMethodInfluentialSahroni, A., Miladiyah, I., Widiasmara, N., & Setiawan, H. (2023) · Advances in Science Technology and Engineering Systems Journal · doi:10.25046/aj080309
Applications of Natural Time Analysis to Disaster Prediction in Other Disciplines indexNatural Time
Varotsos, P. A., Sarlis, N. V., & Skordas, E. S. (2023) · Springer eBooks · doi:10.1007/978-3-031-26006-3_13
Effect of Reperfusion on Time Domain Parameters of Heart Rate Variability
Mubarak, S., Riaz, B., Ashfaq, M., Hamid, S., Rasul, A., & Shafiq, M. (2023) · Journal of Rawalpindi Medical College · doi:10.37939/jrmc.v27i1.2246
Venezia, A., Jones, H., Hohenschurz‐Schmidt, D., Mancini, M., Howard, M. A., & Makovac, E. (2023) · medRxiv · doi:10.1101/2023.12.18.23299896
Kovaleva, A. V., & Николаевна, Л. Е. (2023) · Nauchno-prakticheskii zhurnal «Patogenez» · doi:10.25557/2310-0435.2023.03.54-57
Micro Monitor for Four Physiological Parameters from Fingertip
Zou, X., Li, R., Wu, Z., Zou, Y., & Chen, Q. (2023) · International Conference on Electronic Information Engineering and Computer Communication (EIECC) · doi:10.1109/eiecc60864.2023.10456719
Wang, S., Xing, H., & Liu, Y. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4791006
Guidotti, S., Torelli, P., Ambiveri, G., Fiduccia, A., Castaldo, M., & Pruneti, C. A. (2024) · Neurological Sciences · doi:10.1007/s10072-024-07739-7
Improved Hypertension Detection Models Utilizing Pulse Rate Variability and Asymmetry
Vraka, A., Fácila, L., Hornero, F., Gracia-Baena, J. M., Alcaraz, R., & Rieta, J. J. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-62520-6_19
Kriklenko, E. А., & Kovaleva, A. V. (2024) · Human Physiology · doi:10.31857/s0131164624040082
Hardon, H. J., Kerkhof, Y. N. V., Bartelds, B., Kammeraad, J. A. E., & van Deutekom, A. W. (2025) · doi:10.2196/preprints.70835
Kriklenko, E. А., & Kovaleva, A. V. (2024) · Human Physiology · doi:10.1134/s0362119724700841
Comfort, L. D., Müller, M., Seifritz, E., & Olbrich, S. (2026) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-026-02239-5
“When using PPG-derived pulse signals as a surrogate for HRV, it is important to consider the fundamental physiologi - cal differences between cardiac electrical activity and the peripheral pulse waveform [17, 18 ].”
Metadata
- Authors
- Schäfer, A., & Vagedes, J.
- Affiliations
- Academic Research in Complementary and Integrative Medicine (DE)
- University Children's Hospital Tübingen (DE)
- Corresponding author
- Vagedes, Jan
- ORCID
- Vagedes, Jan
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 166
- Issue
- 1
- Pages
- 15-29
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W188715143
- Cited by
- 661
- References
- 114
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 56 · 2023: 52 · 2022: 57 · 2021: 72 · 2020: 67 · 2019: 49 · 2018: 59 · 2017: 40 · 2016: 40 · 2015: 29 · 2014: 19 · 2013: 9
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- pulse rate variability, heart rate variability, photoplethysmography, pulse oximetry, RR interval, measurement accuracy, physical activity, psychological stress, sensor position, detection algorithm, ambulatory monitoring
- MeSH terms
- Electrocardiography, Heart Rate, Humans, Motor Activity, Pulse, Rest, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review