How accurate is pulse rate variability as an estimate of heart rate variability?
Abstract
Background The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV.Methods We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography).Results/conclusions Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A comparative review of photoplethysmography against ECG stated that photoplethysmography can be used during rest but not during stress (Schafer and Vagedes, 2013).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Schafer and Vagedes, 2013
In the citing paper
“However, it cannot yet be considered to be a surrogate during exercise or stress [17], [129].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
In the citing paper
“Nonetheless, reviews have concluded that PRV is a good surrogate of HRV for certain applications at rest.”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [17]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Flagged first, then by citations
2 of the 114 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Herzman, 1937, Observations on the finger volume pulse recorded photoelectrically, Am J Physiol, 119, 334
- Janssen, 1994, Methods in heart rate variability analysis: may the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm?, High Blood Pressure, 3, 23
- Khandoker, 2011, Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea, Med Eng Phys, 33, 204, 10.1016/j.medengphy.2010.09.020 · DOI
Cited by
Sorted by citations
Items 601–660 of 660
Marques, C., Sayal, A., Palmeira, L., Goss, K., Correia, R., Castilho, P., Pereira, A. T., & Castelo-Branco, M. S. (2025) · International Journal of Eating Disorders · doi:10.1002/eat.24456 · Cited by 1
Kalaiyarasi, M., Rajaguru, H., R.Saravanan, & Karthikamani, R. (2025) · International Conference on Smart Technologies, Communication and Robotics (STCR) · doi:10.1109/stcr62650.2025.11019754
“Schafer and Vagedes demonstrated the feasibility of PPG with a correlation of 95% between the RR generated from PPG and the RR obtained from the ECG [5].”
Shanghavi, A. A., Jayasuriya, J., Cai, Y., & Mehta, R. K. (2025) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/10711813251357929
“Conversely, many other studies have found that PPG measurements are less reliable than ECG in measuring cardiac variability, especially in studies with physical activity due to its susceptibility to motion artifacts (Schäfer & Vagedes, 2013).”
Godkin, F. E., Ooteghem, K. V., Beyer, K. B., Weber, K. S., Cornish, B. F., Tang, A., Martens, K. A. E., & McIlroy, W. E. (2025) · Digital Health · doi:10.1177/20552076251367506
Real-Time Physiological Monitoring System for High-Risk Industrial Operations
Castañeira, M., Abuin, N., Rubio, D., Madrid, F., Roberti, M., Caggioli, M., & Ponce, S. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-06401-1_50
Pulse Rate Variability and All-Cause Mortality Risk in the General Japanese Population
Saito, I., Maruyama, K., Kato, T., Funakoshi, Y., Takata, Y., Tomooka, K., Kawamura, R., Osawa, H., & Tanigawa, T. (2025) · Circulation Reports · doi:10.1253/circrep.cr-25-0193
Chi, H.-M., & Hsiao, T. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01471-9
Premature infant monitoring in neonatal intensive care units
Liao, C., Zeng, Y., Wang, Q., Pan, L., Song, X., Yang, J., Brinker, A. C. D., Lu, H., Zhong, N., & Wang, W. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-26586-0.00009-0
Palacios, A., Martínez‐Gregorio, S., Andreu, C. I., Colombo, D., Cebolla, A., Baños, R., & Wrzesien, M. (2025) · International Journal of Clinical and Health Psychology · doi:10.1016/j.ijchp.2025.100657
Chen, H., Tse, M. M. Y., Chung, J. W. Y., Yau, S. Y., & Wong, T. K. S. (2024) · Figshare · doi:10.6084/m9.figshare.26655997
Ma, C., Hu, B., Chen, S., & Ma, X. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1633924
Toloraya, N., Kovaleva, A., Belousov, I., & Маратовна, А. А. (2026) · Sports · doi:10.3390/sports14020051 · Cited by 1
Li, L., Taha, S. N. S., Nishinaka, Y., Tan, Y., Ohtsu, H., Sinyoung, L. E. E., & Kiyono, K. (2026) · Sensors · doi:10.3390/s26041118
Das, S., Biswas, U., Dastidar, S. G., & Saha, A. (2026) · Engineering Research Express · doi:10.1088/2631-8695/ae4c17
Ali, N. F., Tariq, U., & Al-Nashash, H. A. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3673727
“Although several studies report high agreement between PRV and HRV under resting conditions [120], a recent study indicates that PRV derived from bicep PPG is a poor alternative as it underestimates time-domain metrics, warranting cautious interpretation and distinction from HRV [121].”
Benítez-Agudelo, J. C., Restrepo, D., & Clemente‐Suárez, V. J. (2026) · Trends in Neuroscience and Education · doi:10.1016/j.tine.2026.100283
Vanbuis, J. (2021) · theses.fr (ABES) · doi:10.70675/d1db2870zbd26z4ad6zb5dazcc96fe92cb76
Yumnam, K., Dixit, V., & Kumar, A. (2026) · IEEE International Conference on Interdisciplinary Approaches in Technology and Management for Social Innovation (IATMSI) · doi:10.1109/iatmsi68868.2026.11465214
“…validation research laid the foundation of the PPG-based HRV analysis in the form of a comparison between the parameters based on PPG to the gold standards of ECG. PPG is capable of providing good estimates of HRV in controlled conditions, but not in movement or in pathological conditions [23, 25].”
Computational and Memory Efficiency in Heartbeat Rate Detection: A Review of ECG and PPG Techniques
Merino-Monge, M., Lebrato-Vázquez, C., Castro-García, J. A., Sánchez-Antón, G., & Molina-Cantero, A. J. (2026) · Sensors · doi:10.3390/s26082409
“Nevertheless, it appears that certain stressful situations and physical activity (motion artifacts) often affect the concordance between the two to an unacceptable degree [93], overestimating short-term variability due to the coupling between respiration and the vascular system.”
Measures of fatigue and performance are related to user interface and task in a communication BCI
Klee, D., Memmott, T., & Oken, B. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae60d2
“Though PRV and HRV are not directly interchangeable autonomic biomarkers [58, 59], there is evidence that PRV can be an adequate substitute measure in cases where participants are at rest, such as the present study [60].”
Han, X., Li, E. X., Volodarskiy, A., Slotwiner, D. J., & Zhao, Y. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae66c7
“Pulse rate variability (PRV) refers to the beat-to-beat fluctuations in the time intervals between consecutive pulse waves, typically measured using photoplethysmography (PPG)-based pulse oximeters (Gil et al 2010, Khandoker et al 2011, Schafer and Vagedes 2013).”
Liu, S.-H., Lin, C.-K., Zhu, X., Wang, J.-J., Hsu, Y.-L., & Pan, K. (2026) · Sensors · doi:10.3390/s26103048
“Thus, pulse rate variability (PRV) has been replaced with HRV to describe ANS functions [9,10].”
Mobile Apps for Heart Rate Variability: App Store Search and Content Analysis
de Jager, E., Caulfield, B., Angelidi, E., & Holden, S. (2026) · JMIR Cardio · doi:10.2196/84764 · Cited by 1
“Advances in signal processing have enabled PPG to achieve reasonable accuracy under resting conditions [7-9].”
Challenges in non-invasive measurement of ice swimmers’ physiological parameters
Janowicz, J., & Starosolski, M. (2026) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea69746.2026.11537309
“Although it is not the standard method, it has been proved that time-domain metrics can be derived this way in favorable conditions [32]–[34].”
An IoT-Based Multisensor System for Real-Time Sleep Stage Monitoring
Anan, A., Akter, H., Tabassum, M., Khan, M., Binti, B. R., & Akhtaruzzaman, M. (2026) · IEEE International Conference on Quantum Photonics, Artificial Intelligence & Networking (QPAIN) · doi:10.1109/qpain69676.2026.11545574
“The Arduino Mega 2560 serves as the system’s core, continuously collecting sensor data, buffering it, and preparing it for analysis [19] [20].”
Landscape configuration and peripheral network decoupling during stress recoveryPreprint
Gao, T., Ma, K., Gao, M., Zhang, Y., Hu, L., Lv, C., & Qiu, L. (2026) · Research Square · doi:10.21203/rs.3.rs-9896572/v1
Ciampa, I., Perrone, B., Mosca, U., Fattori, E., Sinagra, S., Cicolin, A., Rechichi, I., & Olmo, G. (2026) · Algorithms · doi:10.3390/a19070531
Liu, S.-H., Houng, Y.-J., & Wang, J.-J. (2026) · Smart innovation, systems and technologies · doi:10.1007/978-3-032-22588-7_28
Low, A., & Lam, B. (2026) · Exploration of Musculoskeletal Diseases · doi:10.37349/emd.2026.1007128
Brunet, J., Hussien, J., Pitman, A., Wurz, A. J., Conte, E., Herry, C. L., Polskaia, N., SEELY, A. J. E., & Seely, D. (2026) · BioPsychoSocial Medicine · doi:10.1186/s13030-026-00367-x
Ríos-Flórez, J. A., Restrepo, L. P., & Vivares-Serna, D. S. (2026) · Frontiers in Psychology · doi:10.3389/fpsyg.2026.1899506
“…finger pulse oximeters (Home Life FS10D, Homelife, Colombia), non-invasive medical devices measuring HR and arterial oxygen saturation (SpO₂) via optical photoplethysmography, validated for experimental estimation of HR and its temporal variations in controlled settings (Schafer and Vagedes, 2013).”
Kriklenko, E., & Kovaleva, A. (2026) · Bioengineering · doi:10.3390/bioengineering13080898
Tang, C. (2026) · International Journal of Sports Science & Coaching · doi:10.1177/17479541261476175
Lin, R., Klop, M., Halfwerk, F. R., Wezel, R. J. A. V., Laverman, G. D., Donker, D. W., & Wang, Y. (2026) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2026.3724905
Chang, Y.-C., Chen, C.-M., Lay, I., Lee, Y.-C., & Tu, C. (2026) · Lasers in Medical Science · doi:10.1007/s10103-026-04992-4
Jiang, C., Wenqian, A., Zhu, T., Zhang, C., Zhu, W., Wang, Y., Luo, S., & Chen, H. (2026) · Aviation · doi:10.3846/aviation.2026.27518
“Previous studies have indicated that PRV can serve as a reliable surrogate for heart rate variability (HRV) obtained from electrocardiography (ECG), demonstrating good feasibility and accuracy (Schäfer & Vagedes, 2013).”
Feasibility of heart rate monitoring in hemodialysis patients using visible imaging: a pilot study
Debnath, U., Srestha, S. D., & Kim, S. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1909505
Vasylenko, D., Scheit, L., Reck, C., Dengler, D., Harth, V., & Oldenburg, M. (2026) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-026-00526-4
“A systematic review showed that PRV is only reliably comparable to HRV in young, healthy subjects under resting conditions [37].”
Saillart, E., Jacobs, K., Claes, S. J., & Vergaelen, E. (2026) · Brain Behavior & Immunity - Health · doi:10.1016/j.bbih.2026.101334
“…in HRV findings may also arise due to its high sensitivity to methodological differences, including variation in measurement modality (e.g., ECG vs. PPG) (Schafer and Vagedes, 2013), sampling rate (Burma et al., 2021), body posture (Fei et al., 1994), and recording duration (Billman, 2013).”
Laeng, B., Zambrana, I. M., Hou, J., Martinsen, Ø. G., & Hou, J. (2026) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2026.113455
Alzahab, N. A., Kaculi, R., SARTINI, G., Cosoli, G., Seferi, R., Moayedi, M., Christoforou, R., Ago, D., Arnesano, M., Schweiker, M., et al. (2026) · IEEE International Workshop on Metrology for Living Environment (MetroLivEnv) · doi:10.1109/metrolivenv70468.2026.11659897
Tsagkarakis, P., Williams, D. A. H., Barlow, C., & Davies, W. (2026) · Journal of the Acoustical Society of America · doi:10.1121/10.0044526
Emotion Analysis in Public Transport
Abaravicius, Z., Kaklauskas, A., & Achilli, E. (2026) · Applied Sciences · doi:10.3390/app16188911
Lee, H., Kim, C., & Lee, S. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.115246
Pre-competition anxiety and cardiac autonomic responses in beginners and skilled equestrian athletes
Amini, M. M., Ezzati, D., & Mansourjozan, Z. (2026) · Human-Animal Interactions · doi:10.1079/hai.2026.0045
Lin, J., & Wu, Z. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111435
Amadei, M., Reichenberger, D., Tung, D., Gannon, H., Gorovoy, S. B., Diaz-Pacheco, A., & Grandner, M. A. (2026) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.126.322875
Ang, J. W. A., Jabar, S. B., Chan, E., Lam, B., Ong, Z.-T., Boey, V., Lee, I., Lee, K. F. A., Gan, W., & Christopoulos, G. I. (2026) · npj Acoustics · doi:10.1038/s44384-026-00072-7
Park, S. H., Hye-kyung, S., & kim, K. W. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.115379
Estimating heart rate variability using facial video photoplethysmography: a pilot validation study
Pstras, L., Okupnik, T., Ponikowska, B., & Paleczny, B. (2026) · Scientific Reports · doi:10.1038/s41598-026-70292-0
“These systematic differences between the vPPG-based and ECG-based values can be explained by the fact that it is generally more difficult to accurately locate the actual peaks in blood pulsations based on the vPPG signal compared to the location of R peaks in ECG signals 51 .”
Radev, H., & Petrova, G. I. (2026) · Applied Sciences · doi:10.3390/app162010201
Casanova‐Lizón, A., Sarabia, J. M., Aracil‐Marco, A., Martínez-García, M., Moya‐Ramón, M., & Manresa‐Rocamora, A. (2026) · Sensors · doi:10.3390/s26206549
“In response to heightened parasympathetic tone, the pulse transit time becomes unstable due to fluctuations in arterial compliance [53].”
Temporal difference encoding for subject-independent mental workload assessment from fingertip PPG
Habibuzzaman, M., Ghoshe, D. K., Rowshon, R., Mansur, A. A., & Nahiyan, K. M. T. (2026) · Array · doi:10.1016/j.array.2026.101344
Obara, A., Seikavandi, M. J., Haddad, K., Overholt, D., Modica, A., Shaffi, S. A., & Narcizo, F. B. (2026) · International Workshop on Human-centric Multimedia Analysis (HCMA) · doi:10.1145/3841192.3841747
Qu, L., Liu, X., Zhang, L., Yu, H., & Ye, Y. (2026) · Cities · doi:10.1016/j.cities.2026.107737
Smartphone Accelerometer Assessment of HRV: Concurrent Agreement of the KubiosHRV App
Cervantes, A., Martínez-Cava, A., Pallarés, J. G., Conesa‐Ros, E., & Ruiz-Navarro, J. J. (2026) · Sensors · doi:10.3390/s26216837
Metadata
- Authors
- Schäfer, A., & Vagedes, J.
- Affiliations
- Academic Research in Complementary and Integrative Medicine (DE)
- University Children's Hospital Tübingen (DE)
- Corresponding author
- Vagedes, Jan
- ORCID
- Vagedes, Jan
- Venue
- International Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 166
- Issue
- 1
- Pages
- 15-29
- ISSN
- 0167-5273 (ISSN-L)
- OpenAlex
- W188715143
- Cited by
- 661
- References
- 114
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 56 · 2023: 52 · 2022: 57 · 2021: 72 · 2020: 67 · 2019: 49 · 2018: 59 · 2017: 40 · 2016: 40 · 2015: 29 · 2014: 19 · 2013: 9
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- pulse rate variability, heart rate variability, photoplethysmography, pulse oximetry, RR interval, measurement accuracy, physical activity, psychological stress, sensor position, detection algorithm, ambulatory monitoring
- MeSH terms
- Electrocardiography, Heart Rate, Humans, Motor Activity, Pulse, Rest, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review