CoChat

Effects of Renal Sympathetic Denervation on Arterial Stiffness and Central Hemodynamics in Patients With Resistant Hypertension

Open access
Brandt, Mathias C., Reda, Sara, Mahfoud, Felix, Lenski, Matthias, Böhm, Michael, Hoppe, Uta C. · 2012 · Journal of the American College of Cardiology
Cited by 154

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

OBJECTIVES This study investigated the effect of catheter-based renal sympathetic denervation (RD) on central hemodynamics in patients with resistant hypertension. BACKGROUND High central blood pressure (BP) increases cardiovascular events and mortality independently of peripheral BP. The effect of RD on central BP is unclear. METHODS A total of 110 patients underwent bilateral RD. Radial artery applanation tonometry and pulse wave analysis were used to derive central aortic pressure and hemodynamic indices at baseline and 1, 3, and 6 months after ablation. Ten patients with resistant hypertension not undergoing RD served as controls. RESULTS RD significantly reduced mean central aortic BP from 167/92 mm Hg to 149/88 mm Hg, 147/85 mm Hg, and 141/85 mm Hg at 1, 3, and 6 months (p < 0.001), respectively. Aortic pulse pressure decreased from 76.2 ± 23.3 mm Hg to 61.5 ± 17.5 mm Hg, 62.7 ± 18.1 mm Hg, and 54.5 ± 15.7 mm Hg 1, 3, and 6 months after RD (p < 0.001), respectively. Six months after RD aortic augmentation and augmentation index were significantly reduced by -11 mm Hg (p < 0.001) and -5.3% (p < 0.001), respectively. Carotid to femoral pulse wave velocity showed a significant reduction from 11.6 ± 3.2 m/s to 9.6 ± 3.1 m/s at 6 months (p < 0.001). Consistently, ejection duration and aortic systolic pressure load were significantly diminished, indicating improvement of cardiac work load by RD. No significant changes were obtained in control patients. CONCLUSIONS Besides the known effect of RD on brachial blood pressure, the study showed for the first time that this novel approach significantly improves arterial stiffness and central hemodynamics, which might have important prognostic implications in patients with resistant hypertension at high cardiovascular risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2012.08.959

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 154

Metadata

Authors
Brandt, M. C., Reda, S., Mahfoud, F., Lenski, M., Böhm, M., & Hoppe, U. C.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2012-11
Volume
60
Issue
19
Pages
1956-1965
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2017767820
Cited by
154
References
17
FWCI
16.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.