The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
MALDI-MS imaging of features smaller than the size of the laser beam
Abstract
The feasibility of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging of features smaller than the laser beam size has been demonstrated. The method involves the complete ablation of the MALDI matrix coating the sample at each sample position and moving the sample target a distance less than the diameter of the laser beam before repeating the process. In the limit of complete sample ablation, acquiring signal from adjacent positions spaced by distances smaller than the sample probe enhances image resolution as the measured analyte signal only arises from the overlap of the laser beam size and the non-ablated sample surface. Image acquisition of features smaller than the laser beam size has been demonstrated with peptide standards deposited on electron microscopy calibration grids and with neuropeptides originating from single cells. The presented MS imaging technique enables approximately 25 microm imaging spatial resolution using commercial MALDI mass spectrometers having irregular laser beam sizes of several hundred micron diameters. With appropriate sampling, the size of the laser beam is not a strict barrier to the attainable MALDI-MS imaging resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Stoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
Schwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.505 · Cited by 646
Proteomic patterns of tumour subsets in non-small-cell lung cancer
Yanagisawa, K., Shyr, Y., Xu, B. J., Massion, P. P., Larsen, P. H., White, B. C., Roberts, J. R., Edgerton, M., Gonzalez, A., Nadaf, S., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14068-8 · Cited by 602
Reyzer, M. L., Hsieh, Y., Ng, K., Korfmacher, W. A., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.525 · Cited by 371
Integrating Histology and Imaging Mass Spectrometry
Chaurand, P., Schwartz, S. A., Billheimer, D., Xu, B. J., Crecelius, A., & Caprioli, R. M. (2004) · Analytical Chemistry · doi:10.1021/ac0351264 · Cited by 365
Dreisewerd, K., Schürenberg, M., Karas, M., & Hillenkamp, F. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04108-j · Cited by 302
Todd, P. J., Schaaff, T. G., Chaurand, P., & Caprioli, R. M. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.153 · Cited by 298
Spengler, B., & Hubert, M. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00376-8 · Cited by 292
High-Spatial Resolution Mass Spectrometric Imaging of Peptide and Protein Distributions on a Surface
Luxembourg, S. L., Mize, T. H., McDonnell, L. A., & Heeren, R. M. A. (2004) · Analytical Chemistry · doi:10.1021/ac049692q · Cited by 267
Molecular imaging of amyloid β peptides in mouse brain sections using mass spectrometry
Stoeckli, M., Staab, D., Staufenbiel, M., Wiederhold, K.-H., & Signor, L. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00386-x · Cited by 225
Chaurand, P., & Caprioli, R. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200209)23:18<3125::aid-elps3125>3.0.co;2-# · Cited by 203
Heterogeneity within MALDI Samples As Revealed by Mass Spectrometric Imaging
Garden, R. W., & Sweedler, J. V. (2000) · Analytical Chemistry · doi:10.1021/ac9908997 · Cited by 187
Self-citationSpatial Profiling with MALDI MS: Distribution of Neuropeptides within Single Neurons
Rubakhin, S. S., Greenough, W. T., & Sweedler, J. V. (2003) · Analytical Chemistry · doi:10.1021/ac034498+ · Cited by 152
Self-citationAssessing Protein Patterns in Disease Using Imaging Mass Spectrometry
Chaurand, P., Schwartz, S. A., & Caprioli, R. M. (2004) · Journal of Proteome Research · doi:10.1021/pr0341282 · Cited by 149
Spatial profiling invertebrate ganglia using MALDI MS
Kruse, R. A., & Sweedler, J. V. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00288-5 · Cited by 117
Self-citation
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Sublimation as a method of matrix application for mass spectrometric imaging
Hankin, J. A., Barkley, R. M., & Murphy, R. C. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.06.010 · Cited by 598
Nanotechnology, nanotoxicology, and neuroscience
Suh, W. H., Suslick, K. S., Stucky, G. D., & Suh, Y.-H. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2008.09.009 · Cited by 406
Advances in Mass Spectrometry for Lipidomics
Blanksby, S. J., & Mitchell, T. W. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073705 · Cited by 366
Mass spectrometry imaging with high resolution in mass and space
Römpp, A., & Spengler, B. (2013) · Histochemistry and Cell Biology · doi:10.1007/s00418-013-1097-6 · Cited by 358
Metadata
- Authors
- Jurchen, J. C., Rubakhin, S. S., & Sweedler, J. V.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-10-01
- Volume
- 16
- Issue
- 10
- Pages
- 1654-1659
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1975567207
- Cited by
- 285
- References
- 18
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.