Enhancement of protein sensitivity for MALDI imaging mass spectrometry after chemical treatment of tissue sections
Open accessAbstract
MALDI imaging mass spectrometry (IMS) has become a valuable tool for the investigation of the content and distribution of molecular species in tissue specimens. Numerous methodological improvements have been made to optimize tissue section preparation and matrix deposition protocols, as well as MS data acquisition and processing. In particular for proteomic analyses, washing the tissue sections before matrix deposition has proven useful to improve spectral qualities by increasing ion yields and the number of signals observed. We systematically explore here the effects of several solvent combinations for washing tissue sections. To minimize experimental variability, all of the measurements were performed on serial sections cut from a single mouse liver tissue block. Several other key steps of the process such as matrix deposition and MS data acquisition and processing have also been automated or standardized. To assess efficacy, after each washing procedure the total ion current and number of peaks were counted from the resulting protein profiles. These results were correlated to on-tissue measurements obtained for lipids. Using similar approaches, several selected washing procedures were also tested for their ability to extend the lifetime as well as revive previously cut tissue sections. The effects of these washes on automated matrix deposition and crystallization behavior as well as their ability to preserve tissue histology were also studied. Finally, in a full-scale IMS study, these washing procedures were tested on a human renal cell carcinoma biopsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A SIMPLE METHOD FOR THE ISOLATION AND PURIFICATION OF TOTAL LIPIDES FROM ANIMAL TISSUES
Folch, J., Lees, M., & Stanley, G. H. S. (1957) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)64849-5 · Cited by 65,189
A RAPID METHOD OF TOTAL LIPID EXTRACTION AND PURIFICATION
Bligh, E. G., & Dyer, W. J. (1959) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o59-099 · Cited by 54,751
Wessel, D., & Flügge, U. I. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90782-6 · Cited by 4,028
Emmert-Buck, M. R., Bonner, R. F., Smith, P. D., Chuaqui, R. F., Zhuang, Z., Goldstein, S. R., Weiss, R. A., & Liotta, L. A. (1996) · Science · doi:10.1126/science.274.5289.998 · Cited by 2,534
Stoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
Self-citationLaboratory methods in histotechnology
Prophet, E. B. (1992) · Medical Entomology and Zoology · Cited by 915
MALDI imaging mass spectrometry: molecular snapshots of biochemical systems
Cornett, D. S., Reyzer, M. L., Chaurand, P., & Caprioli, R. M. (2007) · Nature Methods · doi:10.1038/nmeth1094 · Cited by 886
Self-citationIverson, S. J., Lang, S. L. C., & Cooper, M. H. (2001) · Lipids · doi:10.1007/s11745-001-0843-0 · Cited by 719
Schwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.505 · Cited by 646
Self-citationDirect Molecular Analysis of Whole-Body Animal Tissue Sections by Imaging MALDI Mass Spectrometry
Khatib-Shahidi, S., Andersson, M., Herman, J. L., Gillespie, T. A., & Caprioli, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac060788p · Cited by 505
Self-citationComparison of protein precipitation methods for sample preparation prior to proteomic analysis
Jiang, L., He, L., & Fountoulakis, M. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.10.029 · Cited by 467
Groseclose, M. R., Andersson, M., Hardesty, W. M., & Caprioli, R. M. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1177 · Cited by 377
Self-citationReyzer, M. L., Hsieh, Y., Ng, K., Korfmacher, W. A., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.525 · Cited by 371
Self-citationIntegrating Histology and Imaging Mass Spectrometry
Chaurand, P., Schwartz, S. A., Billheimer, D., Xu, B. J., Crecelius, A., & Caprioli, R. M. (2004) · Analytical Chemistry · doi:10.1021/ac0351264 · Cited by 365
Self-citationAdvances in Lipid Methodology — Two
Kuksis, A. (1994) · Chemistry and Physics of Lipids · doi:10.1016/0009-3084(94)02308-5 · Cited by 349
Automated Acoustic Matrix Deposition for MALDI Sample Preparation
Aerni, H.-R., Cornett, D. S., & Caprioli, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac051534r · Cited by 344
Self-citationDirect Analysis and MALDI Imaging of Formalin-Fixed, Paraffin-Embedded Tissue Sections
Lemaire, R., Desmons, A., Tabet, J. C., Day, R., Salzet, M., & Fournier, I. (2007) · Journal of Proteome Research · doi:10.1021/pr060549i · Cited by 309
Stoeckli, M., Staab, D., & Schweitzer, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.10.007 · Cited by 295
Spengler, B., & Hubert, M. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00376-8 · Cited by 292
High-Spatial Resolution Mass Spectrometric Imaging of Peptide and Protein Distributions on a Surface
Luxembourg, S. L., Mize, T. H., McDonnell, L. A., & Heeren, R. M. A. (2004) · Analytical Chemistry · doi:10.1021/ac049692q · Cited by 267
Proteomics in Diagnostic Pathology
Chaurand, P., Sanders, M. E., Jensen, R. A., & Caprioli, R. M. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63367-6 · Cited by 253
Self-citationChaurand, P., Schwartz, S. A., & Caprioli, R. M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00370-8 · Cited by 241
Self-citationMolecular imaging of amyloid β peptides in mouse brain sections using mass spectrometry
Stoeckli, M., Staab, D., Staufenbiel, M., Wiederhold, K.-H., & Signor, L. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00386-x · Cited by 225
Processing MALDI mass spectra to improve mass spectral direct tissue analysis
Norris, J. L., Cornett, D. S., Mobley, J. A., Andersson, M., Seeley, E. H., Chaurand, P., & Caprioli, R. M. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.10.005 · Cited by 220
Self-citationDirect Profiling of Lipid Distribution in Brain Tissue Using MALDI-TOFMS
Jackson, S. N., Wang, H.-Y. J., & Woods, A. S. (2005) · Analytical Chemistry · doi:10.1021/ac050276v · Cited by 217
Chaurand, P., & Caprioli, R. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200209)23:18<3125::aid-elps3125>3.0.co;2-# · Cited by 203
Self-citationStoeckli, M., Farmer, T. B., & Caprioli, R. M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00126-3 · Cited by 201
Self-citationCornett, D. S., Mobley, J. A., Dias, E. C., Andersson, M., Arteaga, C. L., Sanders, M. E., & Caprioli, R. M. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600119-mcp200 · Cited by 191
Self-citationMALDI-MS Direct Tissue Analysis of Proteins: Improving Signal Sensitivity Using Organic Treatments
Lemaire, R., Wisztorski, M., Desmons, A., Tabet, J. C., Day, R., Salzet, M., & Fournier, I. (2006) · Analytical Chemistry · doi:10.1021/ac060565z · Cited by 189
McCombie, G., Staab, D., Stoeckli, M., & Knochenmuss, R. (2005) · Analytical Chemistry · doi:10.1021/ac051081q · Cited by 186
Imaging Mass Spectrometry: Principles and Potentials
Chaurand, P., Schwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2005) · Toxicologic Pathology · doi:10.1080/01926230590881862 · Cited by 172
Self-citationOptimizing UV laser focus profiles for improved MALDI performance
Holle, A., Haase, A., Kayser, M., & Höhndorf, J. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.1041 · Cited by 167
Imaging of peptides in the rat brain using MALDI-FTICR mass spectrometry
Taban, I. M., Altelaar, A. F. M., van der Burgt, Y. E. M., McDonnell, L. A., Heeren, R. M. A., Fuchser, J., & Baykut, G. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.09.017 · Cited by 164
Reyzer, M. L., Caldwell, R. L., Dugger, T. C., Forbes, J. T., Ritter, C. A., Guix, M., Arteaga, C. L., & Caprioli, R. M. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-2231 · Cited by 163
Self-citationGarrett, T. J., Prieto-Conaway, M. C., Kovtoun, V., Bui, H., Izgarian, N., Stafford, G., & Yost, R. A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.09.019 · Cited by 160
Assessing Protein Patterns in Disease Using Imaging Mass Spectrometry
Chaurand, P., Schwartz, S. A., & Caprioli, R. M. (2004) · Journal of Proteome Research · doi:10.1021/pr0341282 · Cited by 149
Self-citationSynthesis/Degradation Ratio Mass Spectrometry for Measuring Relative Dynamic Protein Turnover
Cargile, B. J., Bundy, J. L., Grunden, A. M., & Stephenson, J. L. (2003) · Analytical Chemistry · doi:10.1021/ac034841a · Cited by 143
Imaging Mass Spectrometry of Neuropeptides in Decapod Crustacean Neuronal Tissues
DeKeyser, S. S., Kutz‐Naber, K. K., Schmidt, J. J., Barrett‐Wilt, G. A., & Li, L. (2007) · Journal of Proteome Research · doi:10.1021/pr060603v · Cited by 120
Sugiura, Y., Shimma, S., & Setou, M. (2006) · Analytical Chemistry · doi:10.1021/ac060974v · Cited by 119
Spatial profiling invertebrate ganglia using MALDI MS
Kruse, R. A., & Sweedler, J. V. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00288-5 · Cited by 117
PREPARATION OF LIPID EXTRACTS FROM TISSUES
Christie, W. W. (1993) · Cited by 94
Sugiura, Y., Shimma, S., & Setou, M. (2006) · Journal of the Mass Spectrometry Society of Japan · doi:10.5702/massspec.54.45 · Cited by 89
Profiling and imaging proteins in tissue sections by MS.
Chaurand, P., Schwartz, S. A., & Capriolo, R. M. (2004) · PubMed · Cited by 75
Self-citationDirect analysis of neuropeptides by in situ MALDI-TOF mass spectrometry in the rat brain.
Fournier, I., Day, R. W., & Salzet, M. (2003) · PubMed · Cited by 51
Maneta-Peyret, L., Compère, P., Moreau, P., Goffinet, G., & Cassagne, C. (1999) · The Histochemical Journal · doi:10.1023/a:1003844107756 · Cited by 27
Cited by
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Self-citationA concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Yang, J., & Caprioli, R. M. (2011) · Analytical Chemistry · doi:10.1021/ac200998a · Cited by 382
Self-citationThomas, A., Charbonneau, J. L., Fournaise, E., & Chaurand, P. (2012) · Analytical Chemistry · doi:10.1021/ac2033547 · Cited by 333
Self-citationSample preparation for mass spectrometry imaging: Small mistakes can lead to big consequences
Goodwin, R. J. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.012 · Cited by 313
Metadata
- Authors
- Seeley, E. H., Oppenheimer, S. R., Mi, D., Chaurand, P., & Caprioli, R. M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-01
- Volume
- 19
- Issue
- 8
- Pages
- 1069-1077
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2007498119
- Cited by
- 300
- References
- 45
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.